6 <strong>VORTEX</strong><br />
As much comfort as you want...<br />
Meaning of the AUTOlearn comfort settings<br />
Intermediate settings are possible (knob is continuously variable)<br />
1 Max. energy<br />
saving, minimum<br />
pump<br />
run-times.<br />
2 Normal<br />
comfort, short<br />
pump runtimes.<br />
Displayed operating states<br />
Green continuous<br />
light<br />
Pump running.<br />
Circulation<br />
on request,<br />
„learning“, or<br />
disinfection<br />
run.<br />
Green flashing<br />
light<br />
Pump not<br />
running.<br />
<strong>Co</strong>oling down<br />
or learned<br />
period of absence.<br />
3 Basic setting<br />
– good comfort,<br />
average<br />
pump runtimes.<br />
Green-red<br />
flashing light<br />
Pump running.<br />
But: the nonreturn<br />
valve<br />
does not close.<br />
4 Very high<br />
comfort,<br />
normal pump<br />
run-times.<br />
Red flashing<br />
light<br />
Pump running.<br />
But: electrical<br />
connection of<br />
sensor cable is<br />
detached.<br />
5 Max. comfort,<br />
extended<br />
pump runtimes.<br />
Red continuous<br />
light<br />
Pump not running.<br />
Dry running<br />
or non-return<br />
valve is<br />
blocked or<br />
cable box has<br />
loosened or<br />
boiler is cold.