6 <strong>VORTEX</strong><br />

As much comfort as you want...<br />

Meaning of the AUTOlearn comfort settings<br />

Intermediate settings are possible (knob is continuously variable)<br />

1 Max. energy<br />

saving, minimum<br />

pump<br />

run-times.<br />

2 Normal<br />

comfort, short<br />

pump runtimes.<br />

Displayed operating states<br />

Green continuous<br />

light<br />

Pump running.<br />

Circulation<br />

on request,<br />

„learning“, or<br />

disinfection<br />

run.<br />

Green flashing<br />

light<br />

Pump not<br />

running.<br />

<strong>Co</strong>oling down<br />

or learned<br />

period of absence.<br />

3 Basic setting<br />

– good comfort,<br />

average<br />

pump runtimes.<br />

Green-red<br />

flashing light<br />

Pump running.<br />

But: the nonreturn<br />

valve<br />

does not close.<br />

4 Very high<br />

comfort,<br />

normal pump<br />

run-times.<br />

Red flashing<br />

light<br />

Pump running.<br />

But: electrical<br />

connection of<br />

sensor cable is<br />

detached.<br />

5 Max. comfort,<br />

extended<br />

pump runtimes.<br />

Red continuous<br />

light<br />

Pump not running.<br />

Dry running<br />

or non-return<br />

valve is<br />

blocked or<br />

cable box has<br />

loosened or<br />

boiler is cold.