SP-10.15 – NOV ‘10<br />
MV/MVH 306-426-456<br />
606-806-1006<br />
CHANGE ON PC BOARD<br />
SOFTWARE<br />
Starting from the following serial numbers:<br />
MV 306 S.N. 00277<br />
MV 426 00217<br />
MV 456 00808<br />
MV 606 00864<br />
MV 806 00071<br />
MV 1006 00229<br />
the software of the PC Board Part Nbr CM 33580250 has been changed in order to<br />
disable the operation of the Ice Thickness Sensor during the first 7 minutes of the<br />
freezing cycle or after 3 minutes from the start up of the water pump during the freezing<br />
cycle (the first reached one)<br />
The disable of the Ice Thickness Sensor during the first part of the freezing cycle is<br />
needed to avoid “wrong” signals transmitted to the PC Board at the beginning of the<br />
freezing cycle when ice is not yet made into the cells and splashed water can reach the<br />
metal plates of the Ice Thickness Sensor moving prematurely the machine in the defrost<br />
cycle.