ATyS M - Socomec
ATyS M - Socomec
ATyS M - Socomec
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>ATyS</strong> M<br />
Three-phase and single-phase<br />
modular automatic transfer switch<br />
from 40 to 160 A
SOCOMEC:<br />
intelligent changeover systems<br />
As a worldwide leading company in changeover power<br />
solutions, SOCOMEC is introducing an innovative new<br />
changeover concept based on switch technology dedicated<br />
to replacement power supplies and single-phase or threephase<br />
safety from 40 to 160 A.<br />
<strong>ATyS</strong> M:<br />
fully integrated control and<br />
automatic changeover functions<br />
SOCOMEC has developed a new concept combining the<br />
benefits of switching technology and fast operation with<br />
unique control flexibility.<br />
<strong>ATyS</strong> M:<br />
a specific response<br />
to IEC or EN 60947-6-1<br />
changeover switching standards<br />
The new range of <strong>ATyS</strong> M changeover switching has been<br />
designed, tested and proven according to the criteria defined<br />
in the international product standards IEC 60947-3 and<br />
60947-6-1. Its compliance with this standard guarantees<br />
a quality product which meets switching and changeover<br />
applications requirements.<br />
APPLI 184 A<br />
A<br />
A<br />
230 VAC<br />
40 A 1323 4004<br />
63 A 1323 4006<br />
80 A 1323 4008<br />
100 A 1323 4010<br />
125 A 1323 4012<br />
160 A 1323 4016<br />
<strong>ATyS</strong> M 6e<br />
230 / 400 VAC<br />
40 A 1354 4004<br />
63 A 1354 4006<br />
80 A 1354 4008<br />
100 A 1354 4010<br />
125 A 1354 4012<br />
160 A 1354 4016<br />
127 / 230 VAC<br />
40 A 1353 4004<br />
63 A 1353 4006<br />
80 A 1353 4008<br />
100 A 1353 4010<br />
125 A 1353 4012<br />
160 A 1353 4016<br />
Without communication<br />
230 / 400 VAC<br />
40 A 1364 4004<br />
63 A 1364 4006<br />
80 A 1364 4008<br />
100 A 1364 4010<br />
125 A 1364 4012<br />
160 A 1364 4016<br />
127 / 230 VAC<br />
40 A 1363 4004<br />
63 A 1363 4006<br />
80 A 1363 4008<br />
100 A 1363 4010<br />
125 A 1363 4012<br />
160 A 1363 4016<br />
ATYSM 022 A<br />
With communication<br />
230 / 400 VAC<br />
40 A 1384 4004<br />
63 A 1384 4006<br />
80 A 1384 4008<br />
100 A 1384 4010<br />
125 A 1384 4012<br />
160 A 1384 4016<br />
127 / 230 VAC<br />
40 A 1383 4004<br />
63 A 1383 4006<br />
80 A 1383 4008<br />
100 A 1383 4010<br />
125 A 1383 4012<br />
160 A 1383 4016
ully integrated Normal / Backup function<br />
he best in breaking and control technology, dedicated to source switching<br />
WITCHING<br />
OPERATION<br />
MONITORING<br />
INSTALLATION<br />
wo mechanically interlocked<br />
ower switches.<br />
A configurable automatic control<br />
associated with a backup<br />
manual operation.<br />
A built-in configuration and<br />
control interface, simple or<br />
advanced.<br />
A modular product adapted to<br />
any type of enclosure integration.<br />
<strong>ATyS</strong> M 3s <strong>ATyS</strong> M 6s <strong>ATyS</strong> M 6e<br />
160 A<br />
ATYSM 200 A<br />
ATYSM 023 A<br />
ATYSM 201 A<br />
ATYSM 024 A<br />
ATYSM 022 A<br />
40 A<br />
Motorised changeover switch<br />
Dual power supply<br />
built-in control relay<br />
Communication*<br />
tripping**<br />
Specific version. ** Return to zero without external energy source.<br />
ocomec switching also includes<br />
An ATS bypass range<br />
Mains<br />
Backup<br />
> An extended <strong>ATyS</strong> range of ratings up<br />
to 3200 A*<br />
> SIRCOVER manual changeover range<br />
G<br />
From 40 to 160 A<br />
From 125 to 3200 A<br />
ø<br />
….....................<br />
ø<br />
SIRCO M 8 P SIRCOVER 8 P*<br />
ø<br />
ø<br />
ø<br />
ø<br />
...............................<br />
GAMME 148 A<br />
<strong>ATyS</strong> M<br />
<strong>ATyS</strong> 6e<br />
ø<br />
ø<br />
ATYS 102 B<br />
.............................<br />
* Also available as an enclosed product.<br />
SIRCO M<br />
changeover switch<br />
(I-0-II)<br />
SIRCOVER<br />
ø<br />
ø<br />
> A BYPASS range<br />
.........................................<br />
UPS<br />
SIRCO M<br />
changeover switch<br />
(I-0-II)<br />
SIRCOVER*<br />
* SIRCOVER Bypass<br />
12 + 4 pole<br />
SVR 059 A<br />
COMUT 034 A
Innovation dedicated to source switching<br />
An optimised breaking system<br />
> Choice of switching technology<br />
• An on load switch disconnector providing<br />
safety isolation combined with high<br />
making and breaking characteristics.<br />
• Safety isolation.<br />
• Stable positions.<br />
ATYSM 029 B<br />
A dedicated control interface<br />
> <strong>ATyS</strong> M 3s: motorised changeover with external control<br />
ATYSM 202 A<br />
> A new switching module combining<br />
• High dynamic withstand.<br />
• Fast operation.<br />
• High number of operations.<br />
ATYSM 038 A<br />
ATYSM 031 B<br />
> <strong>ATyS</strong> M 6s: automatic, simple and ergonomic motorised<br />
changeover<br />
Configurable automatic transfer switch cycles, with stable positions.<br />
> Two power switches<br />
Mechanically and electrically<br />
interlocked.<br />
> <strong>ATyS</strong> M 6e: advanced, programmable automatic motorised<br />
changeover<br />
Fully programmable automatic transfer switch cycles ensuring<br />
position stability or return to 0 position feature upon loss of network.<br />
SI<br />
SII<br />
ATYSM 002 B<br />
Ultra fast electrical control<br />
Automatic control logic<br />
> Electromagnetic control<br />
Allows extremely fast switching<br />
< 180 ms.<br />
Automatic mode (AUT)<br />
> An available energy storage<br />
device<br />
Enables the switch to return to 0<br />
position without any power source<br />
available (<strong>ATyS</strong> M 6e).<br />
Backup manual operation<br />
ATYSM 037 A<br />
Source 1 failure<br />
End “t” source 1 failure<br />
Generator start<br />
Source 2 availability<br />
End “t” source 2 availability<br />
Switch to position 0<br />
End “t” stop to position 0<br />
Switch to position II<br />
Switch to position I<br />
End “t” stop to position 0<br />
Switch to position 0<br />
no<br />
Semi automatic mode<br />
End “t” source 1 availability<br />
Source 1 availability<br />
Generator stop<br />
End “t” cool down timer before generator<br />
yes<br />
Manual<br />
operation<br />
Example (generator application):<br />
Source 1 : priority power source<br />
Source 2 : backup power source<br />
“t” : timer<br />
Flexible integration<br />
> Enclosed products<br />
ATYSM 015 B<br />
ATYSM 014 B<br />
ATYSM 203 A<br />
ATYSM 030 B<br />
ATYS 028 E GB<br />
ATYSM 016 B<br />
> Selection of<br />
Automatic / Manual<br />
operating mode<br />
via the protective<br />
sealable cover.<br />
> Backup manual<br />
operation using a<br />
standard allen key.<br />
> Padlocking function<br />
configurable in<br />
position 0 or in all<br />
three positions (I,<br />
0, II).<br />
IP54.<br />
ATYSM 196 A<br />
IP3x.<br />
Single-phase<br />
Three-phase<br />
ATys M 3s ATys M 6s ATys M 3s ATys M 6s ATys M 6e<br />
40 A 1823 2004 1854 2004 1823 4004 1854 4004 1884 4004<br />
63 A 1823 2006 1854 2006 1823 4006 1854 4006 1884 4006<br />
80 A 1823 2008 1854 2008 1823 4008 1854 4008 1884 4008<br />
100 A 1823 2010 1854 2010 1823 4010 1854 4010 1884 4010<br />
125 A 1823 2012 1854 2012 1823 4012 1854 4012 1884 4012<br />
160 A 1823 2016 1854 2016 1823 4016 1854 4016 1884 4016<br />
COFF 366 A
Switching for industrial, service sector and residential applications<br />
Six ratings 40 / 63 / 80 / 100 / 125 / 160 A<br />
2 or 4 pole versions<br />
<strong>ATyS</strong> M 3s <strong>ATyS</strong> M 6s <strong>ATyS</strong> M 6e<br />
Electrical operation I - 0 - II Automatic product Automatic product<br />
Applications<br />
Normal / Backup without automatic controller<br />
•<br />
Normal / Backup with built-in automatic controller • •<br />
Stable positions • • •<br />
Load changeover<br />
•<br />
FUNCTIONS<br />
Power supply<br />
External<br />
•<br />
Integrated • •<br />
Operation<br />
Backup manual operation of the 3 positions,<br />
configurable<br />
• • •<br />
Electrical (dry contact) control of positions I, 0<br />
and II<br />
• •*<br />
Automatic control of positions I, 0 and II • •<br />
Return to 0 position feature upon loss of source<br />
•<br />
Monitoring<br />
3 voltages on networks I and II • •<br />
Frequency on networks I and II • •<br />
Phase rotation on networks I and II<br />
•<br />
Asymmetry of networks I and II<br />
•<br />
Automatic controller configuration<br />
By potentiometer and micro-switch<br />
•<br />
By screen + keyboard<br />
•<br />
V n<br />
, F n<br />
, V threshold, F threshold • •<br />
Driving with or without priority • •<br />
Adjustable operating timers • •<br />
Control type (impulse or switch / contactor)<br />
•<br />
Display<br />
Position, fully visualised breaking • • •<br />
LED: source status, automatic mode, fault LED • •<br />
LED: switch positions, supply, tests, control<br />
•<br />
V, F, timers, number of operations, last event •<br />
REMOTE CONTROL<br />
Outputs<br />
Generator start / stop order • •<br />
Product availability<br />
(not fault and not manual mode)<br />
• •*<br />
Programmable output (source, availability, fault)<br />
•*<br />
Inputs<br />
Test on load • •*<br />
Retransfer • •*<br />
Automatic mode inhibit • •*<br />
Other programmable inputs<br />
(test off-load, position control, etc.)<br />
•*<br />
Remote control<br />
Human / Machine Interface (<strong>ATyS</strong> D10 and D20)<br />
•<br />
RS485 communication (JBUS / MODBUS)<br />
•**<br />
* 3 inputs / 3 outputs (programmable).<br />
** Product reference is different: communication by RS485 connection (JBUS/ MODBUS) allows up to 31 <strong>ATyS</strong> M to be connected to a PC or a PLC over 1500 m.<br />
A product for all power changeover applications from 40 to 160 A<br />
> Network / Genset<br />
• Controlled via the generator<br />
• ATS solution<br />
> Network / Network<br />
• Building services<br />
<strong>ATyS</strong> M 3s<br />
GS<br />
<strong>ATyS</strong> M 6s<br />
<strong>ATyS</strong> M 6e<br />
GS<br />
<strong>ATyS</strong> M<br />
<strong>ATyS</strong> M 6e<br />
Non-critical<br />
loads<br />
Critical<br />
loads<br />
UPS<br />
ATYSM 003 C GB<br />
Non-critical<br />
loads<br />
Critical<br />
loads<br />
UPS<br />
ATYSM 004 C GB<br />
<strong>ATyS</strong> M<br />
ATYSM 005 D<br />
Non-critical<br />
loads<br />
Critical<br />
loads<br />
UPS<br />
ATYSM 006 D GB
A complete range of accessories<br />
<strong>Socomec</strong> worldwide<br />
In EUROPE<br />
> Bridging bars<br />
A dedicated, BELGIUM compact accessory<br />
B - 1190 Brussel<br />
providing changeover output common<br />
info.scp.be@socomec.com<br />
point keeping cable connec-<br />
Tel. +32 (0)2 340 02 30<br />
tion capacity complete (protection<br />
FRANCE<br />
index F - 94132 IP2X). Fontenay-sous-Bois Cedex<br />
Tel. +33 (0)1 45 14 63 30<br />
info.scp.fr@socomec.com<br />
GERMANY<br />
D - 76275 Ettlingen<br />
Tel. +49 (0)7243 65 29 2 0<br />
info.scp.de@socomec.com<br />
ITALY<br />
I - 20098 San Giuliano Milanese (MI)<br />
Tel. +39 02 9849821<br />
info.scp.it@socomec.com<br />
POLAND<br />
> Single 01-625 pole Warszawa voltage sensing<br />
Tel. +48 91 442 64 11<br />
tap<br />
info.scp.pl@socomec.com<br />
Provides two terminals per pole for<br />
SLOVENIA<br />
voltage SI - 1000 sensing Ljubljana or power supply<br />
requirements.<br />
Tel. +386 1 5807 860<br />
info.scp.si@socomec.com<br />
It can be fitted on any pole keeping<br />
SPAIN cable connection capacity<br />
complete. E - 08310 Argentona (Barcelona)<br />
Tel. +34 93 741 60 67<br />
info.scp.es@socomec.com<br />
ThE NEThERLANDS<br />
NL - 3991 CD Houten<br />
Tel. +31 (0)30 760 0901<br />
> Auxiliary info.scp.nl@socomec.com contact<br />
Each ThE product UNITED KINGDOM can take up to 2<br />
Hitchin Hertfordshire SG4 0TY<br />
auxiliary Tel. +44 contact (0)1462 440033 blocks. One unit<br />
comprises info.scp.uk@socomec.com 1 NO / NC contact for<br />
each<br />
TURKEY<br />
position (I, 0 and II).<br />
Specifications: 34775 Istanbul 250 VAC / 5A maximum.<br />
Tel. +90 (0) 216 540 71 20<br />
info.scp.tr@socomec.com<br />
hEAD OFFICE<br />
SOCOMEC GROUP<br />
S.A. SOCOMEC capital 10 951 300 €<br />
R.C.S. Strasbourg B 548 500 149<br />
B.P. 60010 - 1, rue de Westhouse<br />
F-67235 Benfeld Cedex - FRANCE<br />
VALID FOR FRANCE<br />
www.socomec.com<br />
In ASIA<br />
Single-phase<br />
NORTh EAST ASIA<br />
P.R.C 200052 Shanghai - China<br />
Tel. +86 (0)21 5298 9555<br />
info.scp.cn@socomec.com<br />
40 to 125 A: 1309 2006<br />
SOUTh EAST ASIA & PACIFIC<br />
160 A: 1309 2016<br />
Singapore 408723<br />
Tel. +65 6506 7600<br />
info.scp.sg@socomec.com<br />
Three-phase<br />
SOUTh ASIA<br />
122001 Gurgaon, Haryana - India<br />
Tel. +91 124 4562 700<br />
info.scp.in@socomec.com<br />
40 to 125 A: 1309 4006<br />
160 A: 1309 4016<br />
1399 4006<br />
1309 0001<br />
InTERnATIOnAL SALES<br />
DEPARTMEnT<br />
SOCOMEC<br />
1, rue de Westhouse - B.P. 60010<br />
F - 67235 Benfeld Cedex - FRANCE<br />
Tel. +33 (0)3 88 57 41 41<br />
Fax +33 (0)3 88 74 08 00<br />
info.scp.isd@socomec.com<br />
ATYSM 198 A<br />
ATYSM 025 A<br />
ATYSM 026 A<br />
ATYSM 028 A<br />
In MIDDLE EAST<br />
In nORTh AMERICA<br />
> Terminal shrouds (pair)<br />
UNITED Protection ARAB against EMIRATES direct contact USA, CANADA & MEXICO<br />
Dubai, U.A.E.<br />
Cambridge, MA 02142 USA<br />
with terminals or connecting parts.<br />
Tel. +971 (0) 4 29 98 441<br />
Tel. +1 617 245 0447<br />
info.scp.ae@socomec.com<br />
A specific front hole enables info.scp.us@socomec.com<br />
access to terminals’ tightening<br />
screws for thermographic<br />
measurement or voltage sensing.<br />
2294 4016<br />
> Sealable cover (for <strong>ATyS</strong> M 6s)<br />
Prevents access to the product’s<br />
configuration.<br />
> <strong>ATyS</strong> D10 or D20 remote<br />
interfaces (for <strong>ATyS</strong> M 6e)<br />
To display source availability and<br />
changeover state on the front of<br />
a panel.<br />
RJ45 cable connection.<br />
YOUR DISTRIBUTOR<br />
Single-phase<br />
Three-phase<br />
1359 2000<br />
1359 0000<br />
ATYS 564 D<br />
1599 2010 1599 2020<br />
non contractual document. © 2013, <strong>Socomec</strong> SA. All rights reserved.<br />
ATYSM 043 A<br />
ATYSM 199 A<br />
ATYSM 027 A<br />
ATYS 565 D<br />
DOC 67093 - 03 / 13 - Photo: Martin Bernhart - Réalisation: SOCOMEC - Gyss Imprimeur Obernai - To help protect the environment, this document has been printed on PEFC paper (Programme To for help the protect Endorsement the environment, of Forest Certification)<br />
this document has been printed on PEFC paper (Programme for the Endorsement of Forest Certification)