64<br />
Table 5.2: Guidel<strong>in</strong>e limits for properties and criteri<strong>on</strong> for reclaimed greywater to be<br />
reused for restricted irrigati<strong>on</strong> i<br />
Parameters Abbreviati<strong>on</strong> Unit Allowable Limit<br />
Biological Oxygen Demand BOD5 mg/l 300<br />
Chemical Oxygen Demand COD mg/l 500<br />
Dissolved Oxygen DO mg/l >2<br />
Total suspended solids TSS mg/l 200<br />
pH pH mg/l 6-9<br />
Nitrate NO3 mg/l 50<br />
Total Nitrogen T-N mg/l 45<br />
Turbidity NTU 25<br />
Table 5.3: Guidel<strong>in</strong>e limits for properties and criteri<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> biological and microbiological<br />
for reclaimed greywater to be reused for restricted irrigati<strong>on</strong><br />
Parameters Abbreviati<strong>on</strong> unit Allowable limit<br />
Escherishia Coli E. coli Most probable --------------*<br />
number or col<strong>on</strong>y<br />
form<strong>in</strong>g unit/100 ml<br />
Intest<strong>in</strong>al Helm<strong>in</strong>thes<br />
Eggs<br />
Intest<strong>in</strong>al Helm<strong>in</strong>thes<br />
Eggs<br />
egg/l < or =1<br />
* Not applicable for restricted irrigati<strong>on</strong><br />
Table 5.4-A: Guidel<strong>in</strong>e limits for properties and criteri<strong>on</strong> for reuse <strong>in</strong> restricted <strong>in</strong><br />
irrigati<strong>on</strong><br />
Parameters Abbreviati<strong>on</strong> Unit Allowable Limit<br />
Phenol Phenol mg/l 0.05<br />
Detergent MBAS mg/l 25<br />
Total Dissolved Solids TDS mg/l 1500<br />
Total Phosphate T-PO4 mg/l 15<br />
i<br />
These guidel<strong>in</strong>es are based <strong>on</strong> results <str<strong>on</strong>g>of</str<strong>on</strong>g> m<strong>on</strong>itor<strong>in</strong>g <str<strong>on</strong>g>of</str<strong>on</strong>g> greywater systems <strong>in</strong>stalled by INWRDAM <strong>in</strong> the Karak<br />
Governorate c<strong>on</strong>ducted by the Water Authority <str<strong>on</strong>g>of</str<strong>on</strong>g> Jordan over the past three years. Recommended biological<br />
parameters are based <strong>on</strong> average treated greywater quality <str<strong>on</strong>g>of</str<strong>on</strong>g> more than 64 analyzed greywater samples.