20.07.2014 Views

The Power of Reliability - Heinemann Electric Canada Ltd.

The Power of Reliability - Heinemann Electric Canada Ltd.

The Power of Reliability - Heinemann Electric Canada Ltd.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Construction Codes<br />

15<br />

Du-Con with shunt/tap voltage<br />

coil<br />

16<br />

Du-Con with relay trip voltage<br />

coil<br />

20<br />

Switch with double pole<br />

auxiliary switch<br />

B<br />

Controls two circuits, with voltage trip<br />

capability, from common voltage source<br />

21<br />

Shunt plate with double pole<br />

auxiliary switch<br />

C<br />

A<br />

B<br />

Controls two circuits, with voltage trip<br />

capability, from two separate voltage<br />

sources<br />

22<br />

D<br />

Shunt/tap — shunt plate coil<br />

C<br />

A<br />

B<br />

D.P.D.T.<br />

Remote indicating switch with two separate<br />

circuits<br />

23<br />

Relay trip — shunt plate coil<br />

A<br />

B<br />

D.P.D.T.<br />

A<br />

B C A<br />

D<br />

C<br />

B<br />

A<br />

High-inrush surge capability with remote<br />

indicating auxiliary switches<br />

25<br />

Du-Con with shunt/tap voltage<br />

coil<br />

Controls two circuits from common<br />

source with high-inrush capability<br />

26<br />

Du-Con with relay trip voltage<br />

coil<br />

Controls two circuits from separate<br />

sources with high-inrush capability on<br />

one circuit<br />

27<br />

Dual rating — shunt plate<br />

B<br />

Controls two circuits, with voltage trip<br />

capability, from common voltage source;<br />

high-inrush capability<br />

32<br />

Shunt/tap — double shunt<br />

plate<br />

C<br />

A<br />

B<br />

Controls two circuits, with voltage grip<br />

capability, from two separate voltage<br />

sources; high-inrush capability<br />

33<br />

D<br />

Relay trip — double shunt<br />

plate<br />

C<br />

A<br />

High<br />

Rating<br />

C<br />

Low<br />

Rating<br />

B<br />

Allows multiple ampere ratings in one<br />

breaker; high-inrush capability<br />

38<br />

Series trip — double shunt<br />

plate<br />

A<br />

B<br />

C<br />

A<br />

D<br />

C<br />

B<br />

A<br />

B<br />

A<br />

Controls two circuits from common<br />

source; provides extra (25x) high-inrush<br />

capability<br />

Controls two circuits from separate<br />

sources; provides extra (25x) high-inrush<br />

capability on one circuit<br />

Provides extra (25x) high-inrush capability;<br />

coil in series with contacts<br />

11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!