27.07.2014 Views

Sales Brochure - HDP150 Package - Corken

Sales Brochure - HDP150 Package - Corken

Sales Brochure - HDP150 Package - Corken

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>HDP150</strong> Autogas Pump<br />

Ideal for High Differential Pressure (HDP) Applications<br />

Such as Liquid Fuel Injection Vehicles<br />

Variable Frequency Drive<br />

Variable Frequency Drive<br />

Bypass Valve<br />

Meter<br />

Pump<br />

Dispenser & Meter<br />

Pump<br />

Suitable for Multiple Dispenser Applications…<br />

In our continuous effort to meet the demands of high pressure fueling<br />

systems, the model 150 is designed for high differential pressure<br />

applications requiring larger capacities. Whether it is two dual hose<br />

dispensers or up to four single hose dispensers, the model 150 is a great<br />

choice for multiple hose applications.<br />

Options Available For Single and Three Phase<br />

Electrical Sources...<br />

Whether you are using single or three phase electricity, <strong>Corken</strong> has an<br />

autogas package for your application. If you have single phase electricity,<br />

you will use our optional variable frequency drive (VFD) package.<br />

Designed for Aboveground and Underground<br />

Tank Applications...<br />

Unlike submersible designs, the model 150 is mounted aboveground so there is<br />

no need to disturb the piping. It has fewer wear parts than the competition and<br />

all parts are easily accessed by simply removing the pump head. These features<br />

allow you to quickly service the pump on site and minimize costly downtime<br />

thereby making the model 150 autogas pump a cost effective alternative.<br />

Available HDP <strong>Package</strong>s<br />

If your business uses three phase electricity, you will use our standard<br />

autogas package with a typical wiring configuration.<br />

Variable Frequency Drive (VFD) Has Many<br />

Features and Benefits...<br />

• Easily converts single phase source to three phase service.<br />

• Slow start-up feature eliminates flow surges.<br />

• Variable motor speed capability maximizes pump performance.<br />

• Includes motor overload protection to minimize potential damage.<br />

• Shipped pre-programmed at 60 Hz with 4 second ramp-up speed.<br />

• Magnetic starter is not required so your installation costs are minimized.<br />

• Standard remote switch available.<br />

Standard <strong>Package</strong><br />

Includes:<br />

• FF/DLF150 autogas pump<br />

• Electric motor (10 hp)<br />

• Bypass valve<br />

• Baseplate (FF150 only)<br />

Autogas Pump with<br />

Electric Motor<br />

Bypass<br />

Valve<br />

Variable<br />

Frequency<br />

Drive<br />

Optional Variable<br />

Frequency Drive (VFD)<br />

<strong>Package</strong> Includes:<br />

• Variable frequency drive (VFD)<br />

• FF/DLF150 autogas pump<br />

• Electric motor (10 hp)<br />

• Bypass valve<br />

• Baseplate (FF150 only)


Continuous Duty Design...<br />

Built for continuous duty service, the model 150 autogas pump<br />

incorporates heavy duty bearings, free floating impeller, a single<br />

mechanical seal, ANSI or DIN flange connections, metric fasteners, and<br />

a ductile iron case.<br />

Multiple Mounting Options...<br />

The model 150 autogas pump is available with two mounting options.<br />

You may select a frame mount (FF150) for direct or belt drive<br />

configurations or a direct mount (DLF150) that bolts to a standard<br />

C-Face 50 Hz (2880 RPM) or 60 Hz (3450 RPM) motor.<br />

Operating Specifications<br />

Inlet: 1-1/2" ANSI 300# RF<br />

(DIN opt.)<br />

Outlet: 1" ANSI 300# RF<br />

(DIN opt.)<br />

RPM: 3450 @ 60 Hz,<br />

2880 @ 50 Hz<br />

Max. working pressure:<br />

400 psig (27.6 bar)<br />

Maximum driver:<br />

20 hp (15 kW)<br />

Max. differential pressure:<br />

200 psig (13.6 bar) @ 50 Hz<br />

250 psig (17.2 bar) @ 60 Hz<br />

Temperature range:<br />

-25° to 225°F (-32° to 107°C)<br />

Flow range:<br />

12–58 gpm<br />

(45.4 to 219.6 L/min)<br />

Performance Curves<br />

Differential Pressure<br />

psi bar hp kW<br />

17.5<br />

17.5<br />

250<br />

200<br />

150<br />

100<br />

50<br />

15.0<br />

12.5<br />

10.0<br />

7.5<br />

5.0<br />

2.5<br />

2880<br />

2880<br />

3450<br />

3450<br />

0 0 0 0<br />

0 50 100 L/min<br />

150 200 250<br />

0 10 20 30 gpm 40 50 60<br />

Capacity<br />

20.0<br />

15.0<br />

10.0<br />

7.5<br />

5.0<br />

3.0<br />

15.0<br />

12.5<br />

10.0<br />

7.5<br />

5.0<br />

2.5<br />

Power Required<br />

3450 RPM @ 60 Hz<br />

Differential pressure:<br />

10.0 bar<br />

145.0 psi<br />

Flow:<br />

128 L/min<br />

33.8 gpm<br />

Power required:<br />

6.3 kW<br />

8.4 hp<br />

Curves based on LPG 1<br />

Capacity<br />

Power required<br />

1 The performance curves are<br />

based on aboveground LPG installations.<br />

Performance curves for<br />

underground LPG tanks will vary<br />

based on the specific installation.<br />

Consult factory.<br />

Outline Dimensions for HDPFF150-101 Mounting<br />

A<br />

Inlet<br />

INLET<br />

5-11/32<br />

(13.57)<br />

4-13/16<br />

(12.23)<br />

OUTLET<br />

B<br />

Inlet<br />

Coupling<br />

guard<br />

Electric<br />

motor driver<br />

CORKEN<br />

C<br />

3<br />

(7.62)<br />

Four 1/2" (1.27)<br />

anchor bolts<br />

6<br />

(15.24)<br />

15<br />

(38.10)<br />

6<br />

(15.24)<br />

1-1/2<br />

(3.81)<br />

1-1/4<br />

(3.17)<br />

1-9/16<br />

(3.97)<br />

All dimensions are in inches (centimeters).<br />

31-1/2<br />

(80.01)<br />

34<br />

(86.36)<br />

Flange Dimensions<br />

Model A (inlet) B (outlet)<br />

FF150 1-1/2" ANSI 300# 1" ANSI 300#<br />

FD150 DIN 2635, 40 PN, 40 mm DIN 2635, 40 PN, 25 mm<br />

C Dimensions All Models<br />

182T–215T Frame 12-3/4" (32.40)<br />

254T–256T Frame 13-3/4" (34.94)<br />

QUALITY<br />

ISO 9001<br />

SYSTEM<br />

ENVIRONMENTAL<br />

ISO 14001<br />

MANAGEMENT<br />

SYSTEM<br />

AG103A<br />

<strong>Corken</strong>, Inc. • A Unit of IDEX Corporation<br />

3805 N.W. 36th St., Oklahoma City, OK 73112 U.S.A.<br />

Phone (405) 946-5576 • FAX (405) 948-7343<br />

Visit our website at http://www.corken.com • E-mail us at info.corken@idexcorp.com<br />

PRINTED IN THE USA<br />

September 2010