02.09.2014 Views

Framo Engineering - Mads Hjelmeland - Subsea UK

Framo Engineering - Mads Hjelmeland - Subsea UK

Framo Engineering - Mads Hjelmeland - Subsea UK

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

High Boost Multiphase Pump Technology –<br />

A Step Change in Deepwater Enhanced Recovery<br />

Kuala Lumpur, 12. June 2009<br />

<strong>Mads</strong> <strong>Hjelmeland</strong><br />

Area Sales Manager<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Presentation Outline<br />

• Introduction and System Overview<br />

• Multiphase Boosting – AS State of fThe Art Update<br />

• High Boost Multiphase Pump<br />

• Test Results<br />

• Flexible Design for Changing Conditions<br />

• Reference Cases in Asia Pacific<br />

• Summary<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Pumps & <strong>Subsea</strong> Systems<br />

<strong>Framo</strong> <strong>Engineering</strong> offer a unique and versatile range of Pumps<br />

for onshore, ,platform and subsea applications.<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Multiphase Metering Systems<br />

<strong>Framo</strong> <strong>Engineering</strong> offer a unique and metrological very robust<br />

Metering System for Multiphase and Wet Gas Measurement.<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Swivels & Marine Systems<br />

<strong>Framo</strong> <strong>Engineering</strong> offer a range of Swivel Stacks and<br />

Fluid Transfer Systems for the oil and gas fleet<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


<strong>Subsea</strong> Pump System<br />

Development & Experience<br />

ELSMUBS<br />

8M<br />

DRAUGEN<br />

270 M LUFENG TROLL<br />

360M 350M<br />

TOPACIO<br />

550 M<br />

CEIBA<br />

900M<br />

FUTURE<br />

1500M<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Total System Supplier<br />

Power Control<br />

Modules<br />

Swivel<br />

Systems<br />

Running Tools<br />

Pump<br />

Modules<br />

Umbilicals<br />

Umbilical<br />

Termination<br />

Head<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Typical Scope Of Supply<br />

Dual Pump Module<br />

Topside Pump Power<br />

& Control Module<br />

Umbilical<br />

System<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Confidence Through Experience<br />

25 booster pump Systems<br />

delivered<br />

52 pump/motor units<br />

400 kW – 2.4 MW motor power<br />

Water depths 100 - 1800 m<br />

Tie-backs – 10 Km<br />

More than 850.000 operating hours<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


<strong>Subsea</strong> Boosting – Total Flexibility<br />

250<br />

SPP<br />

Differentia al Pressure [b bar]<br />

200<br />

150<br />

100<br />

HYBRID<br />

HIGH BOOST<br />

50<br />

MPP<br />

WGC<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100<br />

GVF [%]<br />

Rev.01<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Field Application Examples<br />

‣ Tie-in of wells with low production pressure<br />

‣ Extended d reach of satellite tie-backs<br />

‣ Replace local gas/oil separation plants<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Variation Of Field Operating Conditions<br />

FWHP will generally reduce with time due to :<br />

• Increased water cut<br />

• GOR changing<br />

• Reduced reservoir pressure<br />

WC<br />

PRESSURE<br />

FWHP<br />

WC<br />

FLOW FROM WELL<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Multiphase Pumps – State of The Art<br />

• Capacity: 130 - 2000 Am3/h<br />

• Max Diff. pressure: 60 bar<br />

• GVF: up to 95 % (0-100% mech.)<br />

• Pressure rating : 5000 psi<br />

• Shaft power rating : 300 - 2600 kW<br />

– Motor being qualified to<br />

4000kW<br />

• Helico-axial pump design<br />

• Oil submerged electric motor<br />

• Integrated flow homogenizer<br />

• Static seals to the environment<br />

• Light intervention ti vessel<br />

• Weight: 7-20 metric tonnes<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


<strong>Subsea</strong> Booster Pumps<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


<strong>Framo</strong> <strong>Subsea</strong> Booster Pumps<br />

Multiphase high boost pump<br />

FEATURES:<br />

DUTY • Medium to High range GVF<br />

applications for unprocessed well<br />

boosting<br />

• Low GVF applications, e.g. G/L<br />

Separation cases<br />

TYPE • Proven helico-axial multiphase pump<br />

• Thrust balance design<br />

• Sand tolerant design<br />

DATA • Efficient up to 60% GVF<br />

• Up to 50,000 bbl/d capacity<br />

• Up to 150 bar differential pressure<br />

• Up to 2,600 kW shaft power rating<br />

STATUS • Qualified for operation with GVF 0-<br />

100%<br />

• Differential pressure up to 200 bar<br />

with GVF 0- 60% and 100 to 130 bar<br />

with GVF 60–80%.<br />

• Ready for field application<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


High Boost – Further Testing<br />

1. Wear Test<br />

determine effect of increased clearance in Balance Piston:<br />

a. hydraulic loss due to backflow from outlet to inlet<br />

b. rotor dynamic behavior of pump shaft<br />

c. effects of wear of swirl breaks<br />

2. High Viscosity Test:<br />

a. establish hydraulic and mechanical performance at<br />

high viscosities (250 cP/ 0- 80% GVF)<br />

b. verify start- t up of pump at very high h viscosities<br />

iti<br />

(4000 cP)<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Same Mechanical Design – Same <strong>Subsea</strong> Interface<br />

Different Hydraulics<br />

Standardised Interfaces<br />

Centrifugal<br />

Pump<br />

Hybrid<br />

Pump<br />

Multiphase<br />

Pump<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


High Pressure Pump Design<br />

MAIN FEATURES<br />

‣ Higher Pressure (15000 psi)<br />

‣ Increased power (4 MW)<br />

‣ Deeper Water (3000 m)<br />

‣ Higher Diff. Press. (200 bar<br />

in Multiphase)<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Pumping System Installation – Deep Water<br />

– Guide line less installation<br />

– ROV actuated lock and release between<br />

RT and module<br />

– Override functions<br />

– Barrier fluid compensator system with<br />

accumulators for pump barrier system<br />

pressure control, flushing and sampling<br />

during intervention (with related ROV<br />

valves)<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Total System – Mutineer & Exeter<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Mutineer & Exeter – FSS Installation<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Vincent – FDS Installation<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


SUMMARY<br />

• High boost subsea pumps are qualified and<br />

available (200 bar dP)<br />

• Enables extended reach of remote fields<br />

• Handles heavy and viscous multiphase flow<br />

• Applicable for Greenfields as well as Retrofit to<br />

Brownfields<br />

• Can be maintained by ROV and Light<br />

Intervention Vessel<br />

• Enables Increased Recovery of<br />

Hydrocarbons<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009


Thanks For Listening!<br />

mh@framoeng.asia<br />

Copyright <strong>Framo</strong> <strong>Engineering</strong> AS 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!