(2) Individual PV system with modem for remote inquiry<br />

PV<br />

INVERTER<br />

(1)<br />

RS 232 MODEM MODEM<br />

RS 232<br />

PC<br />

Connection to modem via RS 232<br />

SUB-D connector<br />

When connecting an individual <strong>solar</strong> inverter,<br />

the remote modem is connected directly to an<br />

external interface converter (IC) RS 232 at the<br />

bottom of the <strong>solar</strong> inverter.<br />

Jumper JP400: open<br />

(2) For installation of the remote inquiry<br />

of an individual <strong>solar</strong> inverter, the RS 232<br />

signal can be conducted directly from the<br />

<strong>solar</strong> inverter to the remote modem via<br />

the SUB-D connector. Cable type 2 is used<br />

for this purpose. A cable length of 25 m<br />

should not be exceeded for the RS 232<br />

connection between <strong>solar</strong> inverter and<br />

modem. Jumper JP400 must be in open<br />

position.<br />