Sound Level Meter - Maxtech
Sound Level Meter - Maxtech
Sound Level Meter - Maxtech
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Analog <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />
Check Noise <strong>Level</strong>s Economically<br />
NIST it<br />
•Tripod mount and 9V battery powered, ideal for field use<br />
• Analog output for connection to chart recorders, dataloggers, etc.<br />
• Selectable weighting (‘A’ or ‘C’) and response time (Fast or Slow)<br />
• MAX HOLD front-panel select switch<br />
locks highest reading on the display<br />
•Complete with 9V battery<br />
•Two-color, bright analog display with battery check<br />
• Measurement range from 54 to 126 dB in 7 ranges<br />
• Built-in 0.5" Electret Microphone<br />
Applications<br />
• Identify noise ordinance violations<br />
•Traffic noise measurements<br />
• Community noise measurements<br />
• Theater acoustic studies<br />
• Stereo balancing<br />
Catalog No. Model Description Price<br />
EH119703 407703A Analog <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> $99.00<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
Digital <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />
ANSI and IEC Type 2 with RS-232 PC Interface<br />
SPECIFICATIONS<br />
Range<br />
Accuracy<br />
Weighting<br />
Response time<br />
Microphone<br />
Analog output<br />
Power Supply<br />
Dimensions<br />
Weight<br />
54 to 126 dB<br />
± 2dB @ 94dB, 1000Hz<br />
‘A’ and ‘C’ (Selectable)<br />
FAST and SLOW (Selectable)<br />
0.5" Electret Condenser type<br />
AC: 0.707Vrms<br />
9V Battery<br />
2.7 x 7.1 x 1.4" (68 x 180 x 36mm)<br />
5.1 oz. (160g)<br />
NIST it<br />
•Auto/Manual ranging from 30 to 130dB in three 50dB ranges<br />
•Meets ANSI and IEC Type 2 standards<br />
•A and C selectable frequency weightings<br />
•Fast and Slow selectable response times<br />
• Large digital display with 0.1dB resolution<br />
• Condenser microphone provides precision and stability<br />
•Min/Max and Peak Hold<br />
•AC output for recorders<br />
•RS-232 interface for capturing data directly on a PC<br />
•Complete with batteries, Windows ® compatible software and case<br />
SPECIFICATIONS<br />
Digital Display<br />
5 digit Autorange LCD<br />
Measurement Range<br />
30 to 130dB<br />
Resolution<br />
0.1dB<br />
Accuracy<br />
± 1.5 dB @ 94dB for a 1kHz sine wave<br />
Microphone<br />
1/2" Electret Condensor<br />
Frequency Weighting<br />
“A” and “C” type<br />
Time Response<br />
Slow/Fast<br />
Measurement Frequency Range 31.5Hz to 8KHz<br />
Analog Output<br />
AC: 0.5V (full scale)<br />
Applicable Standards IEC 651 Type 2, ANSI S1.4 Type 2<br />
Power Supply<br />
9V battery<br />
Dimensions/Weight<br />
10.6 x 2.7 x 1.1" / 0.63lbs (285g)<br />
S<br />
<strong>Sound</strong> <strong>Level</strong><br />
Davis Inotek Instruments<br />
Catalog No. Model Description Price<br />
EH407768 407768 Digital <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> $349.00<br />
EH139849 407744 <strong>Sound</strong> <strong>Level</strong> Calibrator, 94dB 299.00<br />
EH407766 407766 <strong>Sound</strong> <strong>Level</strong> Calibrator, 94dB/114dB 399.00<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
www.davis.com<br />
1141
Digital <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />
NIST it<br />
• Auto/Manual ranging from 30 to<br />
130dB in 6 ranges<br />
• Meets ANSI and IEC Type 2 stds.<br />
• A and C frequency weightings<br />
• Background noise absorber mode<br />
for machine noise measurements<br />
filters ambient noise<br />
• Stores Max and Min levels<br />
• Max Hold latches maximum value<br />
on display<br />
• RS-232 interface for capturing data<br />
directly on a PC, optional Windows <br />
software<br />
• Complete with batteries and case<br />
SPECIFICATIONS<br />
Digital Display<br />
3- 1 ⁄2 digit (1999 count) Autorange LCD<br />
Bargraph Display<br />
50dB display range (1dB resolution)<br />
Measurement Range 30 to 130dB (35 to 130dB for “C” weighting)<br />
Resolution<br />
0.1dB<br />
Accuracy<br />
± 1.5 dB @ 94dB for a 1kHz sine wave<br />
Microphone<br />
Electret Condensor .24" (6 mm dia.) type<br />
Sampling time<br />
updates every 0.5 seconds<br />
Analog output<br />
AC: 0.707 Vrms (full scale); DC: 10mVDC/dB<br />
Power Supply<br />
9V battery, optional AC adapter<br />
Dimensions<br />
10 x 3.1 x 1.5" (256 x 80 x 38 mm)<br />
Weight 8.5 oz. (240 g)<br />
Catalog No. Model Description Price<br />
EH407750 407750 Digital <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> $249.00<br />
EH407752 407752 RS-232 Software and Cable 49.00<br />
EH139849 407745 94dB Calibrator 299.00<br />
EH156117 156117 117V AC Adapter 17.00<br />
EH156230 156230 220V AC Adapter 35.00<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
<strong>Sound</strong> <strong>Level</strong> Calibrators<br />
NIST it<br />
94dB or combination 94dB/114dB, 1kHz Professional Calibrator for 0.5” or 1.0” Microphones<br />
S<br />
•Calibrates and verifies <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> operation<br />
•For use on <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s with 0.5" or 1.0" microphones<br />
• Durable die-cast, aluminum housing<br />
• 1kHz sine wave at 94dB/114dB is generated to an accuracy of 5% (frequency)<br />
and ± 0.8dB<br />
•3 position switch (OFF/94dB/114dB)<br />
• Total Harmonic Distortion (THD)
<strong>Sound</strong> <strong>Level</strong> Datalogger<br />
Built-in Recorder Stores up to 16000 Readings with RS-232 interface and<br />
Software to Transfer Data to a PC<br />
• Accuracy to ± 1.5dB<br />
• Large LCD display with function indication, time/date stamp and fast 50<br />
segment bar graph display<br />
• Datalogging function with user selectable sampling time sequences from 0.5 to<br />
32767 secs.<br />
• Stored data can be easily transferred to a PC via RS-232 interface and<br />
analyzed using software & cable provided<br />
•A & C frequency weighting<br />
•Fast and Slow time weighting<br />
• 0.1 dB resolution<br />
• Max Hold function<br />
• Meets ANSI S1.4 Type 2 and IEC 651 standards<br />
• Detachable 0.52" (13.2mm) diameter condenser microphone<br />
• Analog AC/DC recorder output 10mVDC/decibel<br />
•Automatic built-in calibration check (94dB)<br />
• Complete with microphone wind cover, PC software on 3.5" diskette, Serial<br />
cable, 9V battery and carrying case<br />
NIST it<br />
Catalog No. Model Description Price<br />
EH407762 407764 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Datalogger $599.00<br />
EH407769 407766 94/114dB Calibrator for 0.5' or 1" microphones 399.00<br />
EH407051 407051 Insulated recorder cable 3' for AC/DC Outputs 15.00<br />
EH139401 — AC Adapter 19.00<br />
EH4077621 — 6' Microphone extension cord 79.00<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
Integrating <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />
Windows ® Based<br />
Data Acquisition Software<br />
NIST it<br />
• 4 Digit LCD with analog bargraph<br />
• Display modes: SPL, SEL, MAX-<br />
L/MIN-L, and Leq<br />
• A and C Frequency weighting<br />
• Impulse/Fast/Slow response<br />
settings<br />
• Datalogging function records up to<br />
32,000 records<br />
• Real time calendar/clock<br />
• Built-in RS-232 interface with included<br />
Windows logging software<br />
• Tripod mount<br />
• Complete with wind shield, adjustment<br />
screwdriver, interface cable<br />
and connector, Windows based<br />
software, battery, and case<br />
S<br />
Windows ® Based<br />
Data Acquisition Software<br />
SPECIFICATIONS<br />
Accuracy<br />
± 1.5dB (ref 94dB @ 1KHz)<br />
Resolution<br />
0.1dB<br />
Digital Display<br />
4 digital LCD<br />
Measurement Range<br />
30dB to 130dB<br />
Linearity Range<br />
100dB<br />
Measurement Frequency Range 31.5Hz to 8KHz<br />
Microphone<br />
1<br />
⁄2 " Electret condenser microphone<br />
Analog AC/DC Output<br />
2Vrms (at full scale), 10 mVDC/dB<br />
Dimensions<br />
10.4 x 2.8 x 0.8" (265 x 72 x 21 mm)<br />
Weight 10.9 oz (310 g)<br />
Catalog No. Model Description Price<br />
EH407780 407780 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> $1,499.00<br />
EH407769 407766 94/114 dB Calibrator for 0.5" or 1" microphones 399.00<br />
EH407051 407051 Insulated recorder cable 3' for AC/DC Outputs 15.00<br />
EH139401 — 115 VAC Adapter 19.00<br />
EH156230 — 220 VAC Adapter 35.00<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
<strong>Sound</strong> <strong>Level</strong><br />
Davis Inotek Instruments<br />
www.davis.com<br />
1143
Real Time Octave Band Analyzer<br />
Type 2 integrating sound level meter with Octave and 1/3 Octave Band Real Time display<br />
•Wide 100dB range of 30 to 130dB<br />
• 160 x160 dot matrix backlit LCD displays Leq, LE, Lmax, Lmin and Lp<br />
•Built-in memory stores up to 12,280 records in SLM mode and 1024<br />
data points in 1/1 or 1/3 octave mode<br />
• Stored data can be easily transferred to a PC via RS-232 interface and<br />
analyzed using software & cable provided<br />
•A, C and Flat weighting with Fast or Slow response<br />
• 25Hz to 10kHz frequency response<br />
•Meets ANSI and IEC Type 2 standards<br />
•Internal self test when powered ON<br />
• Detachable 0.52"(13.2mm) diameter condenser microphone and Tripod<br />
mount provided on rear<br />
• Analog AC/DC recorder output<br />
• Real time clock with Year, Month, Day, Hour, Minute and Second display<br />
• Optional microphone extension cable for measurements in enclosures<br />
and other remote locations (407764-EXT)<br />
•Complete with microphone wind cover, PC software on CD, Serial cable,<br />
four type C size batteries, adjustment screwdriver, 120VAC adaptor and<br />
carrying case<br />
Applications:<br />
• Real time analysis of noise from any source such as machinery or vehicles<br />
•Monitor office or plant noise and store data for later reference and analysis<br />
•Maintain noise level statistics for internal and external audits<br />
•Perform machinery noise monitoring or use for noise reduction programs<br />
NIST it<br />
S<br />
<strong>Sound</strong> <strong>Level</strong><br />
SPECIFICATIONS<br />
Applicable standards IEC 60651 Type 2, IEC 60804 Type 2, IEC 1260-1995, ANSI S1.4 Type 2<br />
Microphone<br />
1/2-inch Electret condenser microphone<br />
Accuracy<br />
± 1.5dB (ref 94dB @ 1kHz)<br />
Measurement range<br />
30dB to 130dB<br />
Measurement function<br />
Lp , Leq , LE , Lmax , Lmin<br />
Frequency range<br />
25Hz ~ 10kHz<br />
<strong>Sound</strong> level meter display<br />
Numerical : 4 digits, up data cycle 0.5s, resolution 0.1dB<br />
Bar graph : Scale range 100dB , update cycle 0.125s, resolution 0.1dB<br />
Real time clock : Year, Month, Day, Hour, Minute, Second<br />
1/1- 1/3 Analyzer level range 70dB<br />
1/1 Octave and 1/3 Octave 1/1 Octave band center frequencies : (9 bands): 31.5Hz, 63Hz, 125Hz, 250Hz,<br />
band filters<br />
500Hz, 1kHz, 2kHz, 4kHz, and 8kHz.<br />
1/3 Octave band center frequencies : (27 bands) : 25Hz, 31.5Hz, 40Hz, 50Hz,<br />
63Hz, 80Hz, 100Hz, 125Hz, 160Hz, 200Hz, 250Hz, 315Hz, 400Hz, 500Hz, 630Hz,<br />
800Hz, 1kHz, 1.25kHz, 1.6kHz, 2kHz, 2.5kHz, 3.15kHz, 4kHz, 5kHz, 6.3kHz, 8kHz 10kHz<br />
Signal output<br />
AC output : 2 Vrms (at full scale): DC output : 10mVDC / dB<br />
Power<br />
Four type C size 1.5V batteries, External DC power: 6V, 1A<br />
Battery life<br />
Approx. 2hrs<br />
Dimensions & Weight<br />
13.6x3.9x2.4" (34.5x10x6 cm); 33.5oz (950g)<br />
Catalog No. Model Description Price<br />
EH407790 407790 Octave Band <strong>Sound</strong> Analyzer $3499.00<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
1144<br />
Davis Inotek Instruments<br />
www.davis.com
Digital <strong>Sound</strong> <strong>Meter</strong><br />
NIST it<br />
• Small size<br />
• High performance at a low cost<br />
• Real time display with min/max recording<br />
• Meets IEC 651, type 2 class<br />
• <strong>Level</strong> range display<br />
• Includes windscreen, battery, manual and<br />
calibration screwdriver<br />
SPECIFICATIONS<br />
<strong>Level</strong> range Low=32 to 80 dB Med.=50 to 100 dB High=80 to 130dB<br />
Resolution<br />
0.1dB<br />
Accuracy<br />
± 1.5dB<br />
Frequency weighting A, C<br />
Dynamic range 50dB<br />
Frequency range 31.5 Hz to 8kHz<br />
Dimensions<br />
9.1" x 2.1" x 1.3" (232 x 54 x 34 mm)<br />
Auxiliary outputs AC signal output<br />
Power source<br />
1 9V battery<br />
Catalog No. Model Description Price<br />
IT8925 DSM325 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> $149.00<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
Digital <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> with Backlight<br />
NIST it<br />
Model RS232KIT<br />
Catalog No. Model Description Price<br />
IT8924 DSM8922 Digital <strong>Sound</strong> <strong>Meter</strong> with Backlight $249.00<br />
IT8911 RS232CBL RS-232 Transfer Cable 29.00<br />
IT8912 RS232SFT Windows ® RS232 Software 45.00<br />
IT8913 RS232KIT RS-232 Interface Kit 69.95<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
• Monitor the sound levels from traffic noise, alarm systems and<br />
workplace machinery<br />
• Quasi-analog bar indicator: 1 dB display steps, 50 dB display range,<br />
updated every 50 ms<br />
• Measurement level range features 6 ranges<br />
• Multi-frequency calibration to ensure stability<br />
• Fast (125 msec.) or slow (1 sec.) settings<br />
• Min/max record with maximum hold<br />
• Optional RS-232 kit includes Windows ® software & cable<br />
• Background noise absorber filters ambient sound<br />
• Jumbo LCD display with backlight<br />
• Digital display with analog bargraph<br />
• Background noise absorber<br />
• A & C weighting selectable<br />
• Low battery indicator<br />
• Meets IEC 651, type 2 class<br />
SPECIFICATIONS<br />
Measurement level ranges<br />
Auto range<br />
Accuracy<br />
Digital display<br />
Analog output<br />
Measurement frequency range<br />
Power source<br />
Dimensions<br />
30 to 80dB, 40 to 90 dB, 50 to 100 dB,<br />
60 to 110 dB, 70 to 120 dB, 80 to 130 dB<br />
30 to 130 dB (35 to 139 for C weighting)<br />
± 1.5dB<br />
3-1/2 digit LCD with backlight<br />
AC: 0.707 Vrms (full scale);<br />
DC: 10 mV/dB<br />
31.5Hz to 8kHz<br />
1 9V battery<br />
10" x 3.1" x 1.5" (256 x 80 x 38 mm)<br />
S<br />
<strong>Sound</strong> <strong>Level</strong><br />
Davis Inotek Instruments<br />
www.davis.com<br />
1145
<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />
NIST it<br />
The Chameleon is a single instrument that<br />
adapts to the needs of both novice and advanced<br />
users. Every Chameleon comes standard<br />
with Feature Pack 1, providing the most<br />
basic functions of a sound level meter.<br />
Additional Feature Packs may be purchased<br />
separately to change the Chameleon’s<br />
functionality.<br />
Operational in 5 easy steps<br />
in 5 minutes or less<br />
• Step 1<br />
• Step 2<br />
• Step 3<br />
• Step 4<br />
• Step 5<br />
Turn ON — Press the ON/OFF button<br />
Calibrate — Press the CALIB button, insert the microphone<br />
into the calibrator, turn the calibrator on, let the displayed<br />
reading stabilize and press the CALIB button a second<br />
time. Remove the calibrator.<br />
Collect Data — Press the RUN/PAUSE button to begin<br />
storing data. Press the RUN/PAUSE button a second time<br />
to stop storing data.<br />
View Readings — Press the VIEW DATA button repeatedly to<br />
scroll through measurement data.<br />
Clear Memory — Press the CLEAR button. CLR appears on<br />
the display. Press the CLEAR button a second time and<br />
the memory is cleared.<br />
Pack 2 Measurement Data<br />
• SPL<br />
• Lpeak<br />
• Lmin<br />
• Battery Voltage<br />
• Lmax<br />
• Lavg (Leq)<br />
• Elapsed Time<br />
S<br />
SPECIFICATIONS<br />
Standard Pack 1<br />
Operating Range 40 to 140 dB<br />
Amplitude Resolution 0.1 dB<br />
A or C weighted<br />
Response Rate Fast, Slow or Impulse<br />
Data Provided<br />
SPL (<strong>Sound</strong> Pressure <strong>Level</strong>)<br />
Battery Voltage<br />
The data can be imported into other programs, such as Excel®, for data<br />
analysis and generating graphs and reports<br />
UL Listed<br />
C-UL Listed<br />
CE<br />
Battery<br />
9V Alkaline 1604A<br />
Display<br />
2.3 x 1.4 inch display with 3 1/2 digits and<br />
test descriptors<br />
Case size 3.1 x 1.75 x 7.6"<br />
Pack 3<br />
• SPL<br />
• Lmin<br />
• Lmax<br />
Pack 4<br />
• SPL<br />
• Lmin<br />
• Lmax<br />
• Lpeak<br />
• Battery Voltage<br />
• Lavg (Leq)<br />
• Lpeak<br />
• Battery Voltage<br />
• Lavg (Leq)<br />
• Elapsed Time<br />
• Amplitude<br />
Distribution<br />
• Elapsed Time<br />
• Time History<br />
Setup Options — Packs 2 ,3 & 4<br />
• Fast, Slow or Impulse<br />
• Calibration <strong>Level</strong><br />
• A or C Weighting<br />
• 3, 4 or 5 dB doubling<br />
<strong>Sound</strong> <strong>Level</strong><br />
Catalog No. Model Description Price<br />
QS139340 SLM1-MK Chameleon SLM Kit Pack 1 includes <strong>Sound</strong> <strong>Level</strong> meter CI-305 calibrator, wind screen and storage case $969.00<br />
for all accessories<br />
Field Upgrade Packs<br />
QS139341 Pack 2 Software upgrade with interface cable Converts Chameleon to an integrating SLM 289.00<br />
QS139342 Pack 3 Software upgrade with interface cable Converts Chameleon to an integrating SLM with Amplitude 396.00<br />
Distribution Data logging<br />
QS1393421 Pack 4 Software upgrade with interface cable Converts Chameleon to an integrating SLM with Time History 396.00<br />
Data logging<br />
QS139343 2135-2030-04 Windows Software 117.00<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
1146<br />
Davis Inotek Instruments<br />
www.davis.com
<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />
NIST it<br />
Quest’s new easy-to-use model 210 sound<br />
level meter offers basic measurement features<br />
in Type 2 accuracies at a great value.<br />
It is the perfect choice for many laboratory,<br />
community, military, and industrial measurement<br />
applications.<br />
The large LCD display provides readings in<br />
0.1dB increments as well as indicating a low<br />
battery (LOBAT) condition. The slide switches<br />
make the meters extremely easy-to-operate<br />
- even while wearing gloves.<br />
The durable red “granite-look” molded<br />
polymer case is lightweight and compact,<br />
making the 210 as red, rugged and reliable as<br />
they come.<br />
• User-Friendly Features<br />
A large, easy-to-read LCD display and simple slide switches combine<br />
for easy operation and viewing of data<br />
• Simple one-button calibration<br />
It’s as easy as a press of a button. No tools or screwdrivers required<br />
• Portable design<br />
The “granite-look” molded polymer case is extremely lightweight and<br />
compact. Only 8.4 oz. (238 g) including the battery<br />
• RFI Shielding<br />
The 210 is housed in a rugged RF shielded case<br />
• Output Jack<br />
Connection to peripheral devices, such as recorders and oscilloscopes,<br />
is made possible with an output jack<br />
• Slide-in Battery Compartment<br />
To eliminate battery connection failure, the meter has a unique slide-in<br />
battery compartment<br />
SPECIFICATIONS<br />
Standards<br />
Model 210 Type 2<br />
ANSI S1.4-1983 (R1997), IEC 60651-1979 EN60651, CE Mark<br />
Measurement Range<br />
40 to 130 dBA<br />
Frequency Weighting Networks<br />
“A” weighting<br />
<strong>Meter</strong> Response<br />
Fast & Slow<br />
Microphone<br />
Non-removable prepolarized condenser (electret) microphone cartridge mounted in plastic 0.52” (13.5 mm)<br />
diameter nose cone<br />
Temperature Range Operation 14°F to 122°F (0°C to + 50°C)<br />
Storage -4°F to 140°F (-20°C to + 60°C) less batteries<br />
Effect of Electromagnetic Fields Negligible<br />
Operating Humidity<br />
0 to 95% relative humidity, non-condensing<br />
Batteries<br />
One 9-volt alkaline battery, approximately 25-30 hours<br />
Size<br />
2.81” w 7.6” x 1.3” (7.13 cm x 19.3 cm x 3.3 cm)<br />
Weight<br />
8.4 oz. (238 g ) including battery<br />
Pending Approvals<br />
UL, CSA, EEx<br />
Catalog No. Model Description Price<br />
QS139201 210 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> with soft pouch $390.00<br />
QS139202 59-536 Calibrator kit includes QC-10 calibrator with 56-990 calibration adapter 469.00<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
S<br />
<strong>Sound</strong> <strong>Level</strong><br />
Davis Inotek Instruments<br />
www.davis.com<br />
1147
Basic and Integrating <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s<br />
NIST it<br />
Quest’s 1200 and 2200 Impulse Integrating<br />
<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s offer superior noise measurements<br />
and analysis at a competitive price. The<br />
1200 provides precision Type 1 accuracy while the<br />
2200 offers Type 2 accuracy.<br />
Quest’s new easy-to-use 1100 and 2100 sound<br />
level meters offer basic measurement features in<br />
precision Type 1 and Type 2 accuracies.<br />
Model 1100/1200<br />
Model 2100/2200<br />
Models 1100 and 2100<br />
• Frequency Weighting Options<br />
• Wide, Selectable dB Range<br />
• Two Operating Modes<br />
Models 1200/2200<br />
• Weighting Options - Choose between “A”, “C”, or “Z” (Linear)<br />
weighting for all measurements<br />
• Selectable Exchange Rates<br />
• Wide Operating Range<br />
All Models<br />
• A large, easy-to-read LCD display and simple slide switches combine<br />
for easy operation and viewing of data<br />
• Simple One-Button Calibration<br />
• Portable Design<br />
• RFI Shielding - Housed in a rugged RF shielded case<br />
• Slide-in Battery Compartment<br />
• Output Jack<br />
S<br />
SPECIFICATIONS<br />
Models 1100/2100 Models 1200/2200<br />
Standards Type 1/Type 2 Type 1/Type 2<br />
Measurement Ranges 30 to 140 dBA 30 to 140 dBASPL<br />
40 to 140 dBC 43 to 143 dBA Peak<br />
Frequency Weighting “A” and “C” Weighting A, C, or Z<br />
<strong>Meter</strong> Response Fast and Slow Fast, Slow, Impulse or Peak<br />
Microphone<br />
Field replaceable .52 inch diameter prepolarized condenser (electret) microphone<br />
Temperature Operating Range<br />
14°F to 122°F (-10°C to + 50°C)<br />
Effect of Electrostatic/Electromagnetic Fields Negligible<br />
AC/DC Output<br />
Both AC/DC outputs are provided through a single 3.5 mm stereo jack. Output impedance is 1000 ohm.<br />
Each 0.167 V change equals 10 dB (1V/60dB)<br />
Operating Humidity<br />
0 to 95% relative humidity, non-condensing<br />
Batteries<br />
One 9-volt alkaline battery, approximately 25-30 hours<br />
<strong>Sound</strong> <strong>Level</strong><br />
Catalog No. Model Description Price<br />
QS139302 1100-20 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Kit includes QC-20 Calibrator, wind screen and storage case $1,680.00<br />
QS139303 1100R-20 Remote SLM Kit includes remote microphone, QC-20 calibrator and storage case 1,782.00<br />
QS139304 2100-10 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Kit includes QC-10 calibrator, wind screen and storage case 1,050.00<br />
QS139305 2100R-10 Remote SLM Kit includes remote microphone, QC-10 calibrator, wind screen and storage case 1,150.00<br />
QS139308 1200-20 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Kit includes WS-7 windscreen, calibrator adapter, storage case and QC-20 Calibrator 2,710.00<br />
QS139309 1200R-20 Remote <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Kit includes WS-7 windscreen, calibrator adapter, storage case, and QC-20 Calibrator 2,812.00<br />
QS139306 2200-10 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Kit includes WS-7 windscreen, calibrator adapter, storage case and QC-10 Calibrator 1,460.00<br />
QS139307 2200R-10 Remote <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Kit includes WS-7 windscreen, calibrator adapter, storage case and QC-10 Calibrator 1,562.00<br />
QS2015 59-733 Remote microphone cable with connectors 10 ft. 130.00<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
1148<br />
Davis Inotek Instruments<br />
www.davis.com
Integrating Datalogging <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s<br />
NIST it<br />
Enables the Use of One Instrument to<br />
Analyze “A”, “C” or Linear Weighted<br />
<strong>Sound</strong> <strong>Level</strong>s Using a Choice of<br />
Exchange Rates<br />
• User-Controlled Logging:<br />
The user is in ultimate control<br />
of what is logged, displayed<br />
and printed, selecting from<br />
SPL, Leq, LavQ, TWA,<br />
Lmax,Lmin,LDN, CNEL,<br />
Pa2Hrs, SEL, exceedance<br />
levels, and time information<br />
•Wide Selection of Studies:<br />
Manual-,automatic-, or<br />
threshold-triggered studies<br />
provide the user with versatile<br />
control<br />
• Response and Weighting<br />
Options:<br />
The 2900 provides fast, slow,<br />
peak and impulse response<br />
with “A”, “C”, or Linear<br />
weighting<br />
• Integration and Datalogging<br />
Capabilities<br />
• Battery-Protected Memory<br />
• Optional Octave Filter<br />
•Printer/Computer Interface<br />
• Optional Parallel Interface<br />
Model<br />
2900<br />
®<br />
MODEL 2900 SPECIFICATIONS<br />
Standards ANSI S1.4-1983, Type 2; IEC 651-1979, Type 2; IEC 804-1985, Type 2<br />
Measurement 20-140dB in seven 60dB ranges<br />
<strong>Meter</strong> only: 30 to 140 dBA. With Filter Sets: 0 to 140 dB (Other levels possible<br />
with optional microphones;noise floor varies depending on microphone type and<br />
filter selection)<br />
Exchange Rates Integrations may be performed with 3,4,5 or 6 dB exchange rate<br />
Microphones Removable precision 0.5" pre polarized condenser (electret) microphone is<br />
standard<br />
Preamplifier Directly accepts 0.50-inch microphone. Input impedance is greater than 1 Gohm<br />
in parallel with 47pF. Removable, the pre-amp will drive up to 100 feet of cable<br />
with no signal loss<br />
AC Output 3.16V RMS at full scale. (3.8V RMS maximum) 3.2 Kohm output impedance.<br />
1<br />
⁄8 " phone jack<br />
DC Output 0 to 1.00V DC; 60dB span. Each 0.167 change equals 10dB. 1 Kohm output<br />
impedance. 3.5mm phone jack<br />
COMM Output RS-232 serial output to printers or computers. Selectable data rates of 300<br />
through 19200 baud. ASCII character format. Optional parallel printer interface<br />
Temperature range<br />
Operating -10°C to +50°C<br />
Operating Humidity 0 to 95%, non-condensing DC Output<br />
0 to 1.00V DC; 60dB span. Each 0.167 change equals 10dB. 1 Kohm output<br />
impedance. 3.5mm phone jack<br />
Effect of Magnetic Fields A magnetic field of 1 Oersted (80A/m) at 60 Hz produces a maximum<br />
reading of 40dB on Linear weighting<br />
Effect of Electrostatic Fields Negligible<br />
Batteries<br />
Two 9V alkaline batteries will provide approximately 16 hours of continuous<br />
operation (9 hours with optional filter set).<br />
S<br />
Catalog No. Model Description Price<br />
QS2900 2900 Type 2 (General Purpose) Integrating/ $2,005.00<br />
Datalogging <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />
Accessories<br />
QS138644 QC-10 Calibrator for Model 2900 435.00<br />
QS2010 OB100 Optional Octave filter:1/1 865.00<br />
QS1389941 OB300 Optional Octave filter:1/1 or 1/3 1,780.00<br />
QS2012 QS-ONE 56-999 software with cable 545.00<br />
QS2013 56-999 Serial interface cable 95.00<br />
QS2014 56-875 Parallel cable 143.00<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
<strong>Sound</strong> <strong>Level</strong><br />
Davis Inotek Instruments<br />
www.davis.com<br />
1149
Precision Integrating <strong>Sound</strong> <strong>Meter</strong> & Calibrator<br />
NIST it<br />
Modern microprocessor technology and an efficient practical<br />
design make this instrument extremely versatile and easy to<br />
use, at a very reasonable price.<br />
Both manual and automatic octave band analysis are provided<br />
by the optional filter sets. The Model 1800 also can be interfaced<br />
with the analysis of occupational, environmental, and other<br />
noise measurements.<br />
Precision accuracy, outstanding features and versatility in a<br />
durable lightweight housing, coupled with the highest quality<br />
and support make the Model 1800 the first choice in sound level<br />
meters for virtually any application.<br />
• Type 1 accuracy for precision noise measurement and statistical analysis<br />
• For industrial, community, R & D, and audiometric applications<br />
• Easy to read LCD digital readout plus additional Quasi-Analogue display<br />
• AC and DC outputs for recording<br />
• RS-232 digital outputs to printers, computers, and NL-15 data logger<br />
• Modular design allows choice of 1/1 and combination 1/3-1/1 octave filter sets<br />
• Optional accessory allows vibration measurement and analysis<br />
• Direct readout of SPL, Leq, SEL, Peak, Impulse, Lmax, Lmin, <strong>Level</strong>s and Run Time<br />
• NIST Certification Included<br />
®<br />
S<br />
<strong>Sound</strong> <strong>Level</strong><br />
Catalog No. Model Description Price<br />
QS138180022 1800-20 Precision Integrated SLM with $3,535.00<br />
QC-20 calibrator<br />
Options<br />
QS1389941 OB300 Octave Band Filter, 1/3 - 1/1 1,780.00<br />
QS2010 OB100 Octave Band Filter, 1/1 865.00<br />
QS1389944 VA-508C Vibration assembly for vibration velocity 980.00<br />
displacement & acceleration<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
SPECIFICATIONS<br />
MODEL 1800 SOUND LEVEL METER<br />
Range<br />
<strong>Meter</strong> only: 20 to 140dB. With filter sets: 0 to 140dB. (Other levels possible with optional micro<br />
phones; noise floor varies depending on microphone type and filter selection)<br />
Standards Meets or exceeds ANSI S1.4 Type 1 and relevant section of IEC 651 Type 1 (1) and IEC 804<br />
Microphones<br />
Removable precision 1 ⁄2" prepolarized condenser (electret) microphone is standard. Optional<br />
1<br />
⁄2" and 1" condenser and other microphones available<br />
Preamp<br />
Removable; input impedance is greater that 1G ohm in parallel with 2 pf. Preamp will drive up<br />
to 100 feet of cable<br />
Polarization<br />
Regulated 200VDC ±2% when using ordinary condenser microphones, switched off when<br />
using prepolarized condenser (electret) microphones<br />
<strong>Meter</strong> Input<br />
Input impedance is 1 MΩ in series with 0.1 MFD. Maximum sinusoidal input voltage is 10V RMS<br />
AC Output<br />
3.16V RMS at full scale (60dB). (3.8V RMS maximum) Output impedance is 32K Ω<br />
DC Output<br />
0 to 1.00VDC; 60dB span. Each 0.167V change equals 10dB<br />
Print Output<br />
Serial output to printers or computers using RS-232 voltage levels. Selectable baud rates of<br />
300, 600, 1200, or 2400. ACSII character format<br />
Data Output<br />
Output transmission of real-time digital data st rate of 16 times per second using RS-232<br />
voltage levels to Quest data loggers<br />
Detector<br />
True RMS; 63dB pulse range<br />
Overload Indication Displays overload condition via annunciator on LCD and annotates them on printout<br />
Frequency Range 4Hz (-3dB) to 50kHz (-3dB) or linear weighting<br />
Frequency Weighting A, B, C, and Linear. When using OB-100 or OB-300 filter sets, any one of the weightings<br />
Networks<br />
may be selected<br />
Display<br />
3 1 ⁄2 Digit :Liquid Crystal Display with additional Quasi-Analogue 60dB indicator in 2dB incre<br />
ments. <strong>Level</strong> display to 0.1dB resolution. Time display of Min:Sec or Hr:Min. Annunciators for<br />
battery check, hold, run, and overload indications<br />
<strong>Meter</strong> Response<br />
Slow, fast, impulse, and peak (onset time constant less than 50µs.) (Peak measurements may<br />
be A, B, C or Linear)<br />
Modes of Operation As an integrated sound level meter, calculates sound pressure level (SPL), maximum level<br />
(MAX), minimum level (MIN), sound exposure level (SEL), and equivalent level (Leq). Also<br />
measures peak and impulse levels<br />
Temperature Range Operation: -10°C to +50°C. Storage (less batteries): -20°C to +60°C<br />
Effect of Magnetic Fields A magnetic field of 1 Oersted (80A/m) at 60Hz produces a maximum reading of 40dB on linear<br />
weighting<br />
Effect of Electrostatic Fields Negligible as long as protection grid is kept on microphone<br />
Batteries<br />
Two 9-volt batteries (NEDA 1604A-Alkaline) will provide approximately 20 hours of continuous<br />
operation (10 hours with optional filter sets) at 25°C<br />
Tripod Mount<br />
Threaded insert on back of meter accepts a standard 1 ⁄4-20 tripod mounting screw<br />
Size<br />
3.3" x 8.2" x 1.8" (84 x 208 x 47mm) not including preamp height<br />
Weight<br />
24 oz. (680 grams) including preamp, half-inch microphone, and batteries<br />
MODEL OB-300, 1/3 - 1/1 OCTAVE FILTER SET<br />
Standards<br />
ANSI S1.11, Order 3 AND IEC R225<br />
Center Frequencies 33 frequencies from 12.5Hz to 20kHz<br />
Frequency Selection Full manual control or automatic sequential stepping through each frequency band<br />
Power Source<br />
<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />
Size<br />
3.3" x 4.2" x 1.8" (84 x 107 x 47mm)<br />
Weight<br />
9 ounces (255 grams)<br />
MODEL OB-100, 1/1 OCTAVE FILTER SET<br />
Standards<br />
ANSI S1.11, Order 3 and IEC R225<br />
Center Frequencies 10 frequencies from 31.5Hz to 16kHz<br />
Frequency Selection Full manual control or automatic sequential stepping through each frequency band<br />
Power Source<br />
<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />
Size<br />
3.3" x 2.8" x 1.8" (84 x 71 x 47mm)<br />
Weight<br />
6 ounces (170 grams)<br />
1150<br />
Davis Inotek Instruments<br />
www.davis.com
<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />
NIST it<br />
The CEL-400 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s are an ergonomic,<br />
modular and effective interpretation of the classic integrating<br />
instrument. The instruments are available as<br />
either direct read out (CEL-440) or datalogging (CEL-<br />
480) versions, in either Type 1 or 2 configurations. Both<br />
instruments provide read out and data storage (CEL-<br />
480) of full 1/3 Ocatve Band Frequency levels, with an<br />
effective dynamic range of 20 to 140 dB(A). Instruments<br />
can display information as either numerical values or<br />
frequency graphs on screen, including specific information<br />
on derived acoustic values.<br />
Power comes from 4 "AA" size batteries, which give<br />
the user up to 25 hours of continuous operation. Each<br />
sound level meter kit includes the instrument, a calibrator,<br />
windscreen and manual in a hard case. The<br />
CEL-480 kit also includes software and a download cable.<br />
All instruments meet the relevant ANSI S1.4 and<br />
IEC standard requirements.<br />
• Advanced modular technology<br />
provides a choice of models<br />
and a clear upgrade path for<br />
future proof operation<br />
• A choice of broad band and frequency<br />
analysis modes offers a<br />
solution to a wide range of the<br />
most common noise measurement<br />
problems<br />
• Manual or automatic operation<br />
depending on model<br />
• Intuitive user control with icon<br />
based keypad and graphic<br />
screen<br />
• On board memory eliminates<br />
the need for hand written<br />
reports<br />
• Download capability to printers<br />
and computers<br />
• Multi-lingual operation<br />
SPECIFICATIONS<br />
Electro-Acoustic<br />
Applicable Standards<br />
IEC 1672 199X class 1 and 2, ANSI S1.4, DIN 45657, IEC<br />
1260 class 1<br />
Slow, Fast and Impulse<br />
Time Weightings<br />
Frequency weightings<br />
rms & peaks<br />
A, C and Z (unweighted)<br />
Amplitude weighting Q=3 plus one from Q=4 or 5 or none<br />
Dynamic span<br />
70 dB per range<br />
Measurement ranges 140, 130, 120, 110, 100, 90 dB for FSD<br />
Noise floor 20 dB (A) type 1, (25 dB (A) type 2)<br />
<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s<br />
NIST it <br />
Digital Impulse <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>, Model CEL 254<br />
The CEL-254 Digital Impulse <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> is specially designed<br />
to meet the sound survey needs of industrial hygienists and safety professionals.<br />
The CEL-254 uses a large digital display with full 0.1dB resolution to<br />
guarantee easy, precise reading.<br />
The sound level meter is equipped with both “A” and “C” frequency<br />
weightings to take advantage of the increasing use of hearing protection<br />
Noise Reduction Rating (NRR) which simplifies the selection of Hearing<br />
Protectors.<br />
Just two measurement ranges, both covering a 70dB span, are needed<br />
to achieve a 30dB-135dB(A) total measurement span so that a single<br />
range of 65dB-135dB is available for industrial surveys.<br />
The meter complies with both the IEC 651 and ANSI S1.4 1983 in the<br />
Type 2 categories by providing both Fast and Slow response times. In addition,<br />
an Impulse response is available for those territories with extra<br />
legislative control over impulsive noise. The Impulse response is normally<br />
used in conjunction with the Maximum Hold function and this combination<br />
is equipped with a rapid reset facility. To optimize measuring opportunities<br />
“maximum hold” is also operational on both Fast and Slow responses.<br />
Digital <strong>Sound</strong> Survey <strong>Meter</strong>, Model CEL 231<br />
The CEL-231 is a simplified version of the CEL-254 maintaining much<br />
of the specification. Fast and Slow time weightings are provided along<br />
with “A” frequency weighting and a measurement range of 30dB(A) to<br />
135dB(A). It will appeal to Safety Engineers and Occupational workers<br />
who require an easy-to-use survey instrument to check whether industrial<br />
noise exposure areas require more detailed investigation.<br />
S<br />
<strong>Sound</strong> <strong>Level</strong><br />
Catalog No. Model Description Price<br />
PR95013 CEL231 Digital <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> $345.00<br />
PR95020 CEL231K1 Digital <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Kit 670.00<br />
with Calibrator<br />
PR95014 CEL254 Digital Impulse <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> 535.00<br />
PR95021 CEL254K1 Digital Impulse <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> 860.00<br />
Kit with Calibrator<br />
Kits include: meter, calibrator, windscreen, case<br />
PR95016 CEL282 <strong>Sound</strong> <strong>Level</strong> Calibrator 225.00<br />
PR95017 CEL4672 Windscreen 10.00<br />
PR95018 CEL5894 Carrying Case 90.00<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
SPECIFICATIONS<br />
Standardization ANSI S1.4-1983 Type 2; IEC 651 Type 2<br />
Accuracy ± 1dB per ANSI S1.4-1983 3.2<br />
Measuring Range 30-135 dBA<br />
Upper Limit 125 dB RMS for signals with crest factor >3;<br />
121 dB RMS for signals with crest factor >5<br />
(CEL-254 only)<br />
Overload<br />
Pre-weighting detector with 2 second<br />
dwell time (CEL-254 only)<br />
Dynamic Range 70dBA<br />
Frequency Weightings A and C (CEL 254); A (CEL-231)<br />
Time Weightings Slow, Fast, and Impulse (CEL-254); Slow and<br />
Fast (CEL-231)<br />
Functions<br />
SPL (<strong>Sound</strong> Pressure <strong>Level</strong>),<br />
L MAX (Maximum <strong>Sound</strong> <strong>Level</strong>),<br />
Low Battery Indicator<br />
Battery Voltage X 10 (CEL-254 only),<br />
SPL (<strong>Sound</strong> Pressure <strong>Level</strong>) (CEL-123 only)<br />
Max. Hold Impulse Resp. Decay < 0.2 dB/min. (CEL-254)<br />
Microphone<br />
Electret Condenser<br />
Display<br />
3 1 ⁄2 digit, 12.7mm high character, LCD<br />
Auxiliary Outputs AC conditioned 7.25V RMS FSD.<br />
Minimum load impedance 39KΩ. DC log RMS<br />
output nominally 25mV/dB. Minimum load<br />
impedance 27KΩ<br />
Batteries<br />
4 X AAA Manganese Alkaline<br />
1152<br />
Davis Inotek Instruments<br />
www.davis.com
<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s<br />
NIST it<br />
<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> 886-2<br />
•Features fast or slow response<br />
•AC and DC outputs, tripod mount and analog meter<br />
• Detachable microphone<br />
• 40-140 dB<br />
• Meets ANSI S1.4-1983; ANSI S1.4-1992<br />
•Frequency = 1000 Hz at 94dB on 90dB range<br />
• “A”, “B”, “C” ext. filter for flat response<br />
• 2-1/2” dial dialog meter, pivot and jewel movement<br />
• 9V alkaline battery provides approximately 40 hours use<br />
897<br />
886-2<br />
884-2 899<br />
<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> 884-2<br />
• Identical to the 886-2 but only offers “A” weighting which closely<br />
corresponds to the human ear<br />
• 40-140 dB<br />
• Meets ANSI S1.4-1983; ANSI S1.4-1992<br />
• “A” ext. filter for flat response<br />
•Frequency = 1000 Hz at 94dB on 90dB range<br />
• 2-1/2”dial dialog meter, pivot and jewel movement<br />
• 9V alkaline battery provides approximately 40 hours use<br />
<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> 899<br />
• Offers choice of fast, slow, and impulse response<br />
•Provides maximum measurement versatility with A, B, and C weighing curves<br />
•AC and DC outputs to drive scopes, recorders and other external<br />
analysis equipment<br />
• 40 to 140 dB<br />
• Meets ANSI S1.4-1983; ANSI S1.4-1992<br />
•Frequency = 1000 Hz at 94dB on 90dB range<br />
• “A”, “B”, “C” ext. filter for flat response<br />
• 2-1/2”dial dialog meter, pivot and jewel movement<br />
• 9V alkaline battery provides approximately 40 hours use<br />
<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>/Dosimeter 897<br />
• Meets ANSI S1.4-1983, D1.25-1978 and IEC 651-1979<br />
specifications<br />
• Selectable ranges and threshold levels<br />
• Selectable exchange rates and criterion levels<br />
• Built-in datalogger and computer/printer output<br />
•Ideal for OSHA and IEC surveys<br />
897 Unit Includes:<br />
•Printer Cable<br />
•AC Adaptor<br />
• Microphone Clip<br />
• Nose Cone<br />
• Wind Screen<br />
• Screwdriver<br />
• Wrench<br />
•NICd Battery<br />
SPECIFICATIONS<br />
<strong>Sound</strong> <strong>Level</strong> Mode Ranges<br />
Accuracy<br />
Dynamic Range<br />
Frequency Response Weighting<br />
Frequency Range<br />
Dosimeter Mode Threshold <strong>Level</strong><br />
Criterion <strong>Level</strong><br />
Criterion Duration<br />
Exchange Rate<br />
Elapsed Time<br />
Recording Time<br />
Printer Interface<br />
Size/Weight:<br />
SMS-2 Kit Includes:<br />
• All accessories included in the 897 Unit<br />
• RS-232-C Serial Cable Calibrator<br />
• 9V Alkaline Battery (for Calibrator)<br />
• 887-2 Calibrator<br />
50 to 100dB, 80 to 30dB<br />
True RMS, type S2<br />
Selectable 50 to 100dB and 80 to 130dB<br />
“A” Weighting<br />
20 Hz to 8 Hz<br />
Selectable from 50 to 99dB in1dB<br />
increments<br />
Selectable 70, 80, 84, 85, or 90dB<br />
8 Hours<br />
Selectable 3, 4, or 5dB<br />
Displays either Hours:Minutes, or<br />
Minutes:Seconds,<br />
up 99 Hours, 59 Minutes, 59 Seconds<br />
31 Hours Maximum<br />
Centronics and RS-232<br />
6.8 x 3.1 x 1.1HWD/18 ozs;<br />
172 x 80 x 28mm HWD/500g<br />
S<br />
Catalog No. Model Description Price<br />
SE65755 40004 886-2 Multi-Weight <strong>Sound</strong> <strong>Level</strong> meter only $592.00<br />
SE65756 40007 886-2 Kit Multi-Weight <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> w/Calibrator 853.60<br />
SE65757 40003 884-2 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> 439.90<br />
SE65758 40006 884-2 Kit <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> w/Calibrator 678.90<br />
SE65759 40005 Impulse <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> 741.50<br />
SE65760 40008 Impulse <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> w/Calibrator 990.60<br />
SE659971 12645 897 Universal Noise Dosimeter Unit 892.00<br />
SE659973 12646 SMS-2 Universal Noise Dosimeter Kit 1,251.30<br />
NISTSD4 — NIST Traceable Certificate with Data for SLM `285.00<br />
<strong>Sound</strong> <strong>Level</strong><br />
Davis Inotek Instruments<br />
www.davis.com<br />
1153
Noise Dosimeters/Datalogging Dosimeters<br />
Q200 is a powerful dosimeter used for display-only applications<br />
Q300 is a highly versatile, multi-function datalogging dosimeter<br />
Q400 is a full featured, advanced datalogging dosimeter<br />
NIST it<br />
S<br />
<strong>Sound</strong> <strong>Level</strong><br />
1154<br />
Model Q200<br />
• Easy-to-Read Display<br />
• Simple Operation<br />
• Battery Changes are a snap<br />
•Instructions where you need them<br />
• Security to protect your work<br />
Two levels are provided to lock out set-up charges or all display functions.<br />
Accidental turn-off or reset are also prevented by five second function count<br />
down<br />
•Tough, Compact Case<br />
Cast aluminum housing provides durability, tested RF protection and intrinsic<br />
safety<br />
Model Q300<br />
•Instructions where you want them<br />
• Log all the information you need including sound levels and peaks<br />
• Meet all the requirements<br />
Three simultaneous dosimeter studies using independent threshold, criteria<br />
and exchange rate assures you will have what you need today and tomorrow<br />
• The power to do the right job<br />
• Long battery life<br />
• See it now, print it later<br />
• The LCD display lets you see what you want now, and parallel/serial output<br />
allows direct printing of all the details<br />
• Security<br />
•Run it even if you are not there<br />
•Auto on/off and auto run time<br />
•Paperless surveys<br />
• The unique event function makes surveying a variety of locations easy. Just<br />
keep track of where you went, and the Q-300 will do the rest, keeping<br />
information separated so you can analyze each location at your convenience<br />
Model Q400<br />
• Two true independent analog circuits<br />
• Simultaneous “A” and “C” measurements—allows for “C” minus “A” calculations<br />
• Field Selectable - Projected dose periods, Threshold levels, Upper limit levels,<br />
Exchange rates, Criterion levels<br />
• Real time clock with automatic start/stop<br />
• Up to 999 (or 100 hours) stored events<br />
• Pre and post calibrations on printout<br />
SPECIFICATIONS<br />
Models Q200 & Q300<br />
Standards ANSI S1.25-991, ANSI S1.4-1983: Type 2; IEC 651-1979,<br />
IEC 804-1985: Type 2; IEC 1252-1993<br />
Measuring Range<br />
Detector<br />
Data Output (Q300 only)<br />
Microphone<br />
Battery<br />
Temperature<br />
Humidity<br />
Electromagnetic<br />
Field Effects<br />
Model Q400<br />
Standards<br />
Operating Range<br />
Dynamic Range<br />
Exchange Rates<br />
Criterion <strong>Level</strong>s<br />
Display<br />
Output<br />
Size/Weight<br />
Davis Inotek Instruments<br />
40-110dB or 70-140dB<br />
True RMS, 63 dB Pulse Range<br />
Uses interface modules connected to the microphone<br />
connector. Parallel operation or selected baud<br />
8mm Shoulder-Mount, Type 2. One piece system: cable,<br />
connector, and microphone<br />
Single 9V alkaline provides approximately 48 hours of<br />
operation<br />
-10° to + 50°C operating<br />
-20° to + 60° storage (battery removed)<br />
0 to 95% non-condensing<br />
Negligible below 50 Oersteds at 50 to 60 Hz. Tested for RF<br />
the frequency range of 10 MHz to 500 MHz<br />
All applicable ANSI and IEC<br />
40-140dB<br />
100dB<br />
3, 4, 5, 6dB, user selectable<br />
Settable between 40-140dB<br />
Graphic LCD with 3 line capability<br />
RS-232/Parallel<br />
5.5” x 2.75” x 1.3” / 15.5 ounces<br />
®<br />
Model<br />
Q300<br />
Model<br />
Q400<br />
Catalog No. Model Description Price<br />
QS200 Q200 Display-only Noise Dosimeter $1,300.00<br />
QS300 Q300 Datalogging Noise Dosimeter 1,890.00<br />
QS3432081 Q400 Data Logging Noise Dosimeter<br />
with printer cable<br />
2,250.00<br />
QS138644 QC-10 Calibrator 435.00<br />
NISTSD4 — NIST Traceable Certificate 285.00<br />
with Data<br />
www.davis.com
Convertible Noise Dosimeter/<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />
NIST it<br />
The CEL-300 Series "Convertible" dosimeters<br />
and sound level meters offer the ability to make<br />
noise measurements in many different environments.<br />
The units are called "Convertible" because<br />
the user can turn a dosimeter into a sound level<br />
meter and back again, simply by inserting a different<br />
microphone. This provides the most flexibility<br />
in a single unit and reduces the cost for the<br />
user.<br />
In dosimeter mode, instruments are delivered<br />
pre-programmed with the operating parameters<br />
to measure noise dose to the relevant standards<br />
(ie OSHA), and measure from 30 to 140 dB in<br />
three 70 dB ranges. Whilst the CEL-320 provides<br />
summary statistics for download, the CEL-360<br />
stores individual readings to provide a full time<br />
history.<br />
In sound level meter mode, instruments possess<br />
up to 20 configurable operating modes, which can<br />
be user programmed to suit any specific task.<br />
Simply selecting the mode and pressing "run"<br />
starts the measurement and displays current information.<br />
Download all the data to the PC for<br />
subsequent analysis.<br />
Both models are suitable for workplace noise<br />
monitoring, simple hand-held noise surveys and<br />
long term boundary monitoring. They are rugged,<br />
lightweight, easy to use and conform to both ANSI<br />
and IEC standards.<br />
SPECIFICATIONS<br />
Standards IEC 1252, 651, 804<br />
ANSI S1.4, S1.25<br />
EN 50081-1, 50081-2, 50082-1, 50082-2<br />
Measurement Range 30 - 140 (in 70 dB ranges)<br />
Microphone<br />
Electret, on 0.8m cable, Type 2 (dosimeter)<br />
Electret, 75mm stalk, Type 2 (SLM)<br />
Battery<br />
9 volt, Alkaline<br />
Operating life<br />
Approx. 40 hours<br />
Measurement runs 50<br />
Threshold levels 2 (70 - 90 dB in 1 dB steps)<br />
Frequency weightings A, C, linear 20 Hz - 20 kHz<br />
Time weightings Fast, Slow, Impulse, Peak<br />
Amplitude weightings 3, 4, 5, 6 dB exchange rates<br />
Displayed information Lp, LAeq, LAE, Leql, Lav, Lmx, Lmn, Lpeak,<br />
%Dose1 & 2 (actual & projected), TWA, LEPd, TWAv, LEPv, Duration,<br />
Date, Time, Run #, Wait, Pause, Battery state<br />
Dimensions (excl mic) 4.8 x 2.6 x 1.2 in<br />
Weight<br />
11 oz.<br />
Data Storage (CEL-360 only)<br />
Memory size<br />
>200,000 data points<br />
Profiles per period 10 (max)<br />
Profile intervals 1 sec to 60 min<br />
Fixed duration timers 5 min to 24 hours<br />
Catalog No. Model Description Price<br />
CEL1001 CEL-320/K1 Dosimeter with calibrator, wind $1,315.00<br />
screen & carrying case<br />
CEL1002 CEL-320D1/K1 Same as above with software 1,585.00<br />
and download cable<br />
CEL1004 CEL-360/K1 Logging dosimeter with calibrator, 1,995.00<br />
wind screen, carrying case,<br />
software and download cable<br />
CEL1006 CEL-425 Microphone to convert to 175.00<br />
sound level meter<br />
NISTSD4 — NIST Traceable Certificate 285.00<br />
with Data<br />
S<br />
<strong>Sound</strong> <strong>Level</strong><br />
Davis Inotek Instruments<br />
www.davis.com<br />
1155
Audio Dosimeters<br />
AMETEK MARK Series audio dosimeters are designed for accuracy,<br />
reliability and ease-of-use. Available in three models, these<br />
extremely portable and lightweight instruments are convenient and<br />
easy to wear. They can also be used as <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s.<br />
The MARK Series feature simple pushbutton operation. Press a<br />
pushbutton and you sequentially display sampled data without disrupting<br />
the sampling process. Status indicators allow the user to<br />
see at a glance that the unit is operating or if the battery is needing<br />
to be charged. The instruments also include a large, easy-to-read<br />
display. A microphone boom is included allowing the instrument to<br />
be used in the sound meter mode.<br />
MARK Series dosimeters can be used with the AMETEK CPI PLUS<br />
computer interface and Data Logger allowing data to be downloaded<br />
to your personal computer.<br />
The MARK Series are extremely lightweight and comfortable to<br />
wear. Units weigh on 9 ounces (250 grams). They feature an<br />
impact resistant housing with tamper-resistant, lockable cover.<br />
There are no exposed keypads. The MARK Series feature field<br />
replaceable microphones that eliminate the need for time-consuming<br />
factory returns. And their commonality of components allow<br />
users to upgrade their MARK Series dosimeter with added features<br />
as their needs expand.<br />
• Meets MSHA 2G safely approval UL listed<br />
- Class 1: C, D<br />
- Class II: E, F, G<br />
- Class III: Hazardous locations<br />
- FM<br />
- CSA<br />
• Simple pushbutton operation<br />
• Data export capability to personal computer<br />
• Lightweight, convenient to use<br />
• Dosimeters may be upgraded with new functions<br />
• Complete noise monitoring kits<br />
S<br />
<strong>Sound</strong> <strong>Level</strong><br />
SPECIFICATIONS<br />
Features Mark 1 Mark 2 Mark 3<br />
Time Standard Standard Standard<br />
Stand By Standard Standard Standard<br />
Dose % Standard Standard Standard<br />
Lavg Standard Standard Standard<br />
SLM Standard Standard Standard<br />
Lmax Standard Standard Standard<br />
DOSE % 90 dB Threshold Optional Standard Standard<br />
Lavg 90 dB Threshold Optional Standard Standard<br />
Time Lmax Optional Standard Standard<br />
Fast Lmax Optional Standard Standard<br />
Projected 8-hour DOSE Optional Standard Standard<br />
Time of > 115 dB Optional Standard Standard<br />
Lavg 1-minute Data Optional Optional Standard<br />
Lavg Time History Optional Optional Standard<br />
Lavg Histogram Optional Optional Standard<br />
TO ORDER, SEE NEXT PAGE ➡<br />
1156<br />
Davis Inotek Instruments<br />
www.davis.com
NIST it<br />
SPECIFICATIONS<br />
MK1 MK2 MK3 AC94 AC1<br />
Operating Range 80-148 dB 94.0 dB<br />
Operating Range 80-140 dB 940.0 dB<br />
Selectable 60-120 dB 114.0 dB<br />
50-100 dB 124.0 dB<br />
SLM<br />
50-140 dB<br />
Maximum <strong>Level</strong> (L max )<br />
50-140 dB<br />
Fast (L max )<br />
1/16 second average<br />
Response (selectable)<br />
Slow or Fast<br />
Criterion Duration<br />
8 hours<br />
Exchange Rate (selectable)<br />
3, 4, 5 dB<br />
Threshold <strong>Level</strong> (selectable)<br />
None, 80, 85, 90 dB<br />
Criterion <strong>Level</strong><br />
80, 84, 85, 90 dB<br />
Weighting<br />
A or C<br />
Communications √ √<br />
(through CPI+)<br />
Software<br />
MKWin Windows-Based Software<br />
(with communications unit)<br />
Approvals MSHA 2G, UL Class I C, D / Class II E, F, G /<br />
Class III Hazardous Locations, FM, CSA<br />
Weight 9 oz. (250 grams) 10 oz. (285 grams)<br />
Dimensions ( L x W x H) 10 x 2.5 x 1.1 in (25.4 x 6.4 x 2.8 cm) 2.0 x 1.75 x 5.5 in (5.1 x 4.4 x 14.0 cm)<br />
Operating Temperature 0° to 122°F (-18 - 50°C) 32 - 122°F (0-50°C)<br />
Battery 9 VDC NEDA 1604 9 VDC NEDA 1604<br />
Catalog No. Model Description Price<br />
AM5320 MK1 Audio Dosimeter with standard Accessories $1,425.00<br />
AM5325 MK2 Audio Dosimeter with standard Accessories 1,755.00<br />
AM5335 MK3 Audio Dosimeter with standard Accessories 2,085.00<br />
AM5351 MK1-Kit Audio Dosimeter with standard Accessories and ACI calibrator 1,925.00<br />
AM5352 MK2-Kit Audio Dosimeter with standard Accessories and ACI calibrator 2,189.00<br />
AM5353 MK3-Kit Audio Dosimeter with standard Accessories and ACl calibrator 2,475.00<br />
Standard Accessories include; Dosimeter, belt-clip, microphone, Micboom, Mic Wind Screen, battery, carrying case, access tools and manual<br />
Windows-based software available for models MK2 and MK3 - see accessories below<br />
AM5310 ACI Acoustical Calibrator (only) with manual and battery 655.00<br />
AM5458 H5458 CPI+ with interface cables, manual and battery 963.00<br />
(required for printing or downloading from MK2 and MK3)<br />
AM5590 H5590 CPI+ with interface cables, MK WIN Software, manual and battery 1,073.00<br />
(required for printing or downloading from MK2 and MK3)<br />
Accessories<br />
AM92011 E92-011 MK WIN Software 375.00<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
S<br />
<strong>Sound</strong> <strong>Level</strong><br />
Davis Inotek Instruments<br />
www.davis.com<br />
1157
Noise Dosimeter/Profiler<br />
NIST it<br />
S<br />
<strong>Sound</strong> <strong>Level</strong><br />
1158<br />
DB-3060<br />
The DB-3060 delivers an economical solution to<br />
those users seeking a basic compliance tool.<br />
Attach a pendant microphone and you have a<br />
noise dosimeter. Substitute a boom microphone<br />
and you’ve converted your noise dosimeter to a<br />
power integrating sound level meter.<br />
Simple and Accurate — The Data You Need At<br />
Your Fingertips<br />
With the press of a button, the DB-3060 provides<br />
all of the basic measurements you need to<br />
comply:<br />
• Displays real-time sound level (SPL)<br />
• Captures and displays the maximum sound<br />
level detected (Lmax)<br />
• Captures and displays the peak sound level<br />
detected (Lpk)<br />
• Calculates and displays average sound level<br />
(Lavg or Leq)<br />
• Calculates and displays average sound level<br />
projected over 8 hours (TWA)<br />
• Calculates and displays % of allowable dose<br />
incurred (Dose)<br />
• Calculates and displays % of allowable dose<br />
expected over 8 hours (Projected Dose)<br />
• Tracks and displays total time over 115 db<br />
Easy Auto-Calibration<br />
Like all DB-3000 series monitors, the DB-3060<br />
field calibration is fast and easy. These monitors<br />
already know what sound level the acoustical calibrator<br />
outputs. Instantly initiate calibration from<br />
the DB-3060 keypad with the calibrator attached<br />
and let the noise monitor do the rest. Any adjustments<br />
that are necessary are automatically determined<br />
and made by the monitor.<br />
Davis Inotek Instruments<br />
DB Series Features<br />
• Noise Dosimeter<br />
• Integrating <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />
• Peak <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />
• Recorded Statistics For Entire Test: Lav, Leq, Lmax, Lpeak, TWA, Dose,<br />
Projected Dose, Total Time Above Ceiling, User Selectable Criteria, Weighting<br />
(A or C), Response Rate (Fast or Slow), Exchange Rate (3, 4, 5 or 6 db)<br />
• Time History Profiler<br />
• Amplitude Distribution Profiler<br />
• Real Time Clock<br />
• For Each Time History Interval<br />
• Lav, Lmax<br />
• Lpeak<br />
• Time History Interval Length<br />
• Time History Ln’s<br />
• Amplitude Distribution Ln’s<br />
• Automatic Start/Stop Recording<br />
• Outputs Reports Directly to Printer<br />
• Transfers Data to PC<br />
DB-3080<br />
•Comprehensive Time History & Amplitude<br />
• Distribution Profiles<br />
• Print Multiple Reports<br />
• Automatically Starts & Stops Recording<br />
• Survey Mode With Auto-Stop<br />
• Advanced Software For Greater Productivity<br />
In today’s business climate, the value of effective<br />
and efficient tools to complete your work cannot<br />
be underrated. Metrosonics takes DB-3080<br />
users to another level of productivity with MS-<br />
3080W Metrosoft ® for Windows ® . This comprehensive<br />
data management and reporting system offers<br />
the benefits of electronically capturing, storing,<br />
analyzing, manipulating, and reporting noise<br />
survey results. MS-3080W takes the integrity, defensibility<br />
and value of your noise studies to unparalleled<br />
levels.<br />
Windows ® Compatibility<br />
MS-3080W works seamlessly with your current<br />
Windows ® printer drivers to provide you with high<br />
quality charts and reports. You will produce professional<br />
looking reports never before possible by<br />
copying and pasting information directly from<br />
Metrosoft ® to other Windows ® programs such as<br />
Word, Excel and Powerpoint.<br />
Powerful Charting Functions<br />
Time History and Amplitude Distribution reports<br />
available from the DB-3080 directly to a<br />
printer may also be generated by MS-3080W in report<br />
or chart format to ease the analysis and comparison<br />
of test results. Metrosoft’s ® tiling function<br />
enables you to perform on-screen, side-by-side<br />
comparisons of data. Zoom features allow enlarging<br />
plotted time history periods for more detailed<br />
examination of survey results at specific points in<br />
time. A scan line may be moved across time history<br />
charts to view the numeric data values<br />
represented by the chart graphics.<br />
Catalog No. Model Description Price<br />
QS139350 DB-3060-MK Noise Dosimeter Kit includes $1,390.00<br />
Dosimeter, wind screen, clip,<br />
CL-304 calibrator and storage case<br />
QS139351 DB-3080-MK Profiling Noise Dosimeter Kit 2,130.00<br />
includes dosimeter, wind screen,<br />
clip, CL-304 calibrator, printer cable,<br />
programming kit, software and<br />
storage case<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
www.davis.com
Personal Noise Dosimeters<br />
NIST it<br />
Measure Total <strong>Sound</strong> Exposure Over an 8-hour Period<br />
Basic Model 407354<br />
Records and displays % dose, dB<br />
sound level, exposure time, and peak<br />
events.<br />
Model 407355<br />
Has same functions as above but<br />
with advanced features: Storage of 5<br />
separate surveys, bi-directional RS-<br />
232 with Windows software, and a<br />
real time clock. Software permits user<br />
to customize setup and retrieve stored<br />
events (% dose, 8 hour % dose, Peak &<br />
RMS flags, exposure time, Peak time<br />
and Peak event duration) or analyze<br />
real time measurements. Includes data<br />
acquisition software, 9 pin to 25 pin<br />
adapter, and RS-232 cable.<br />
• Two low cost, lightweight, easy to use, personal<br />
noise dosimeters<br />
• Perform OSHA and IEC Noise accumulation<br />
surveys<br />
• Adjustable Criterion <strong>Level</strong>, Exchange Rate, and<br />
Threshold<br />
• Applications include Personal accumulated noise<br />
exposure measurement, Workplace noise<br />
assessment, OSHA and other regulatory agency<br />
compliances<br />
• Optional 94/114dB calibrator to perform “before”<br />
and “after” calibration checks per ANSI standards<br />
• Both dosimeters include belt clip and clip-on<br />
microphone, 4 x AAA batteries, mini screwdriver<br />
and carrying case. Model 407355 also includes<br />
software and cables<br />
SPECIFICATIONS<br />
(407354 & 407355)<br />
Standards<br />
Meets ANSI S1.25(1991) Type 2, ISO<br />
1999, BS 402 (1983)<br />
Range/Resolution<br />
70 - 140 dBA / 0.1dB<br />
Digital Display LCD 0.01-9999%<br />
Criterion <strong>Level</strong><br />
80, 84, 85, or 90dB<br />
Exchange Rate<br />
3, 4, 5 or 6 dB<br />
Threshold <strong>Level</strong><br />
70-90 (1db steps)<br />
Frequency weighting A<br />
Response Rate<br />
Fast or Slow<br />
High <strong>Level</strong> Detector/Peak Flag 115dB / 140dB<br />
Dimensions / Weight 4.2 x 2.5 x 1.3" (106 x 64 x 34mm) 8oz.<br />
(227g) incl.batteries<br />
Microphone<br />
1<br />
⁄2 inch electret condenser with 31" cable<br />
407354 407355<br />
Battery Life 38 hrs 34 hrs<br />
Event Storage 1 survey 5 surveys<br />
RS232 Interface no yes<br />
Real time clock no yes<br />
407355 Includes PC Windows software to maintain<br />
records and statistically analyze acquired data<br />
Catalog No. Model Description Price<br />
EH407354 407354 Noise Dosimeter $459.00<br />
EH407355 407355 Noise Dosimeter with RS-232 599.00<br />
Interface<br />
EH407769 407766 94/114dB <strong>Sound</strong> <strong>Level</strong> Calibrator 399.00<br />
EH407764 407764-EXT 15' Microphone extension cable 99.00<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
S<br />
<strong>Sound</strong> <strong>Level</strong><br />
Davis Inotek Instruments<br />
www.davis.com<br />
1159
<strong>Sound</strong>/Light/Voltage/ Event Recorder<br />
NIST it<br />
The CR87E Event Recorder with remote<br />
sensor employs advanced microcontroller design<br />
that enables this versatile instrument to<br />
accurately measure and record voltage, light<br />
and sound. LED display can read length of<br />
event, time between events or total number of<br />
events. Selector switches located on the face<br />
panel allow for the recording of 3 different<br />
event modes at 4 different recording speeds.<br />
S<br />
<strong>Sound</strong> <strong>Level</strong><br />
1160<br />
SPECIFICATIONS<br />
KEV Range<br />
24 VAC to 270 VAC (50/60Hz.)<br />
24 VDC to 180 VDC<br />
KEL Range<br />
Illumination threshold range<br />
18 Lux to 1900 Lux +/- 20%<br />
KES Range<br />
<strong>Sound</strong> threshold range<br />
40 dB to 114 dB @ 1Khz +/- 20%<br />
Ambient Operating Temperature +32°F to + 140°F (0°C to + 60°C)<br />
Ambient Operating Relative Humidity 96% maximum<br />
Chart Speed Selectable<br />
6 hours, 24 hours, 7 days, 31 days<br />
Chart Rotation Mode<br />
Selectable — single turn or<br />
continuous<br />
Chart Speed Accuracy +/- 1%<br />
Chart Diameter<br />
6 inches<br />
Display<br />
3 digit 0.5" LED to display event<br />
interval in minutes, length of the<br />
event in minutes, and/or total<br />
number of events<br />
Display Range<br />
0 - 999 minutes or event counts<br />
Event Probes<br />
KEV — AC/DC Voltage detecting<br />
with two wire clip leads<br />
KEL — A sensitive photocell<br />
KES — A sensitive audio transducer<br />
Primary Power Supply<br />
120 VAC, 50/60 Hz. (220-240 VAC,<br />
50/60 Hz. optional - CR87E220)<br />
Alternative Power<br />
12 Volt vehicle operation with<br />
optional adapter<br />
Battery Backup<br />
8 AA Alkaline batteries (not included)<br />
Battery Life<br />
48 hours continuous use<br />
Recording Pen<br />
Ink Type<br />
Case Size 9 1 ⁄4" x 7 1 ⁄4" x 2 3 ⁄4"<br />
Weight<br />
4 lbs., 7 oz.<br />
Davis Inotek Instruments<br />
• Advanced microcontroller design<br />
• Large LED digital display shows event interval in minutes and/or total<br />
number of events<br />
• Front panel selectable — All controls are located on front panel for<br />
fast and easy setup<br />
• 3 recording modes — 4 recording speeds<br />
• Complete with probes for voltage, light and sound<br />
• Single or continuous chart rotation<br />
• Standard adapter for 120 VAC operation (220 VAC optional)<br />
• Battery backup assures normal operation during power interruptions<br />
• 12 Volt operation — Allows use in vehicular or marine operations<br />
• Furnished complete with 2 cartridge pens & 60 (6” diameter) assorted<br />
charts<br />
• Convenient fold down carrying handle<br />
• Snap-on extra support legs<br />
• Free standing or wall mounted<br />
• Durable polycarbonate case<br />
• Weather proof NEMA type 4X (CSA type 4) case optional<br />
Catalog No. Model Description Price<br />
CR870 CR87E Event Recorder, 110-120 VAC, 50/60 Hz $289.00<br />
NISTSD4 — NIST Traceable Certificate with Data 285.00<br />
www.davis.com