Analog <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />

Check Noise <strong>Level</strong>s Economically<br />

NIST it<br />

•Tripod mount and 9V battery powered, ideal for field use<br />

• Analog output for connection to chart recorders, dataloggers, etc.<br />

• Selectable weighting (‘A’ or ‘C’) and response time (Fast or Slow)<br />

• MAX HOLD front-panel select switch<br />

locks highest reading on the display<br />

•Complete with 9V battery<br />

•Two-color, bright analog display with battery check<br />

• Measurement range from 54 to 126 dB in 7 ranges<br />

• Built-in 0.5" Electret Microphone<br />

Applications<br />

• Identify noise ordinance violations<br />

•Traffic noise measurements<br />

• Community noise measurements<br />

• Theater acoustic studies<br />

• Stereo balancing<br />

Catalog No. Model Description Price<br />

EH119703 407703A Analog <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> $99.00<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

Digital <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />

ANSI and IEC Type 2 with RS-232 PC Interface<br />

SPECIFICATIONS<br />

Range<br />

Accuracy<br />

Weighting<br />

Response time<br />

Microphone<br />

Analog output<br />

Power Supply<br />

Dimensions<br />

Weight<br />

54 to 126 dB<br />

± 2dB @ 94dB, 1000Hz<br />

‘A’ and ‘C’ (Selectable)<br />

FAST and SLOW (Selectable)<br />

0.5" Electret Condenser type<br />

AC: 0.707Vrms<br />

9V Battery<br />

2.7 x 7.1 x 1.4" (68 x 180 x 36mm)<br />

5.1 oz. (160g)<br />

NIST it<br />

•Auto/Manual ranging from 30 to 130dB in three 50dB ranges<br />

•Meets ANSI and IEC Type 2 standards<br />

•A and C selectable frequency weightings<br />

•Fast and Slow selectable response times<br />

• Large digital display with 0.1dB resolution<br />

• Condenser microphone provides precision and stability<br />

•Min/Max and Peak Hold<br />

•AC output for recorders<br />

•RS-232 interface for capturing data directly on a PC<br />

•Complete with batteries, Windows ® compatible software and case<br />

SPECIFICATIONS<br />

Digital Display<br />

5 digit Autorange LCD<br />

Measurement Range<br />

30 to 130dB<br />

Resolution<br />

0.1dB<br />

Accuracy<br />

± 1.5 dB @ 94dB for a 1kHz sine wave<br />

Microphone<br />

1/2" Electret Condensor<br />

Frequency Weighting<br />

“A” and “C” type<br />

Time Response<br />

Slow/Fast<br />

Measurement Frequency Range 31.5Hz to 8KHz<br />

Analog Output<br />

AC: 0.5V (full scale)<br />

Applicable Standards IEC 651 Type 2, ANSI S1.4 Type 2<br />

Power Supply<br />

9V battery<br />

Dimensions/Weight<br />

10.6 x 2.7 x 1.1" / 0.63lbs (285g)<br />

S<br />

<strong>Sound</strong> <strong>Level</strong><br />

Davis Inotek Instruments<br />

Catalog No. Model Description Price<br />

EH407768 407768 Digital <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> $349.00<br />

EH139849 407744 <strong>Sound</strong> <strong>Level</strong> Calibrator, 94dB 299.00<br />

EH407766 407766 <strong>Sound</strong> <strong>Level</strong> Calibrator, 94dB/114dB 399.00<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

www.davis.com<br />

1141


Digital <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />

NIST it<br />

• Auto/Manual ranging from 30 to<br />

130dB in 6 ranges<br />

• Meets ANSI and IEC Type 2 stds.<br />

• A and C frequency weightings<br />

• Background noise absorber mode<br />

for machine noise measurements<br />

filters ambient noise<br />

• Stores Max and Min levels<br />

• Max Hold latches maximum value<br />

on display<br />

• RS-232 interface for capturing data<br />

directly on a PC, optional Windows <br />

software<br />

• Complete with batteries and case<br />

SPECIFICATIONS<br />

Digital Display<br />

3- 1 ⁄2 digit (1999 count) Autorange LCD<br />

Bargraph Display<br />

50dB display range (1dB resolution)<br />

Measurement Range 30 to 130dB (35 to 130dB for “C” weighting)<br />

Resolution<br />

0.1dB<br />

Accuracy<br />

± 1.5 dB @ 94dB for a 1kHz sine wave<br />

Microphone<br />

Electret Condensor .24" (6 mm dia.) type<br />

Sampling time<br />

updates every 0.5 seconds<br />

Analog output<br />

AC: 0.707 Vrms (full scale); DC: 10mVDC/dB<br />

Power Supply<br />

9V battery, optional AC adapter<br />

Dimensions<br />

10 x 3.1 x 1.5" (256 x 80 x 38 mm)<br />

Weight 8.5 oz. (240 g)<br />

Catalog No. Model Description Price<br />

EH407750 407750 Digital <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> $249.00<br />

EH407752 407752 RS-232 Software and Cable 49.00<br />

EH139849 407745 94dB Calibrator 299.00<br />

EH156117 156117 117V AC Adapter 17.00<br />

EH156230 156230 220V AC Adapter 35.00<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

<strong>Sound</strong> <strong>Level</strong> Calibrators<br />

NIST it<br />

94dB or combination 94dB/114dB, 1kHz Professional Calibrator for 0.5” or 1.0” Microphones<br />

S<br />

•Calibrates and verifies <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> operation<br />

•For use on <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s with 0.5" or 1.0" microphones<br />

• Durable die-cast, aluminum housing<br />

• 1kHz sine wave at 94dB/114dB is generated to an accuracy of 5% (frequency)<br />

and ± 0.8dB<br />

•3 position switch (OFF/94dB/114dB)<br />

• Total Harmonic Distortion (THD)


<strong>Sound</strong> <strong>Level</strong> Datalogger<br />

Built-in Recorder Stores up to 16000 Readings with RS-232 interface and<br />

Software to Transfer Data to a PC<br />

• Accuracy to ± 1.5dB<br />

• Large LCD display with function indication, time/date stamp and fast 50<br />

segment bar graph display<br />

• Datalogging function with user selectable sampling time sequences from 0.5 to<br />

32767 secs.<br />

• Stored data can be easily transferred to a PC via RS-232 interface and<br />

analyzed using software & cable provided<br />

•A & C frequency weighting<br />

•Fast and Slow time weighting<br />

• 0.1 dB resolution<br />

• Max Hold function<br />

• Meets ANSI S1.4 Type 2 and IEC 651 standards<br />

• Detachable 0.52" (13.2mm) diameter condenser microphone<br />

• Analog AC/DC recorder output 10mVDC/decibel<br />

•Automatic built-in calibration check (94dB)<br />

• Complete with microphone wind cover, PC software on 3.5" diskette, Serial<br />

cable, 9V battery and carrying case<br />

NIST it<br />

Catalog No. Model Description Price<br />

EH407762 407764 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Datalogger $599.00<br />

EH407769 407766 94/114dB Calibrator for 0.5' or 1" microphones 399.00<br />

EH407051 407051 Insulated recorder cable 3' for AC/DC Outputs 15.00<br />

EH139401 — AC Adapter 19.00<br />

EH4077621 — 6' Microphone extension cord 79.00<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

Integrating <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />

Windows ® Based<br />

Data Acquisition Software<br />

NIST it<br />

• 4 Digit LCD with analog bargraph<br />

• Display modes: SPL, SEL, MAX-<br />

L/MIN-L, and Leq<br />

• A and C Frequency weighting<br />

• Impulse/Fast/Slow response<br />

settings<br />

• Datalogging function records up to<br />

32,000 records<br />

• Real time calendar/clock<br />

• Built-in RS-232 interface with included<br />

Windows logging software<br />

• Tripod mount<br />

• Complete with wind shield, adjustment<br />

screwdriver, interface cable<br />

and connector, Windows based<br />

software, battery, and case<br />

S<br />

Windows ® Based<br />

Data Acquisition Software<br />

SPECIFICATIONS<br />

Accuracy<br />

± 1.5dB (ref 94dB @ 1KHz)<br />

Resolution<br />

0.1dB<br />

Digital Display<br />

4 digital LCD<br />

Measurement Range<br />

30dB to 130dB<br />

Linearity Range<br />

100dB<br />

Measurement Frequency Range 31.5Hz to 8KHz<br />

Microphone<br />

1<br />

⁄2 " Electret condenser microphone<br />

Analog AC/DC Output<br />

2Vrms (at full scale), 10 mVDC/dB<br />

Dimensions<br />

10.4 x 2.8 x 0.8" (265 x 72 x 21 mm)<br />

Weight 10.9 oz (310 g)<br />

Catalog No. Model Description Price<br />

EH407780 407780 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> $1,499.00<br />

EH407769 407766 94/114 dB Calibrator for 0.5" or 1" microphones 399.00<br />

EH407051 407051 Insulated recorder cable 3' for AC/DC Outputs 15.00<br />

EH139401 — 115 VAC Adapter 19.00<br />

EH156230 — 220 VAC Adapter 35.00<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

<strong>Sound</strong> <strong>Level</strong><br />

Davis Inotek Instruments<br />

www.davis.com<br />

1143


Real Time Octave Band Analyzer<br />

Type 2 integrating sound level meter with Octave and 1/3 Octave Band Real Time display<br />

•Wide 100dB range of 30 to 130dB<br />

• 160 x160 dot matrix backlit LCD displays Leq, LE, Lmax, Lmin and Lp<br />

•Built-in memory stores up to 12,280 records in SLM mode and 1024<br />

data points in 1/1 or 1/3 octave mode<br />

• Stored data can be easily transferred to a PC via RS-232 interface and<br />

analyzed using software & cable provided<br />

•A, C and Flat weighting with Fast or Slow response<br />

• 25Hz to 10kHz frequency response<br />

•Meets ANSI and IEC Type 2 standards<br />

•Internal self test when powered ON<br />

• Detachable 0.52"(13.2mm) diameter condenser microphone and Tripod<br />

mount provided on rear<br />

• Analog AC/DC recorder output<br />

• Real time clock with Year, Month, Day, Hour, Minute and Second display<br />

• Optional microphone extension cable for measurements in enclosures<br />

and other remote locations (407764-EXT)<br />

•Complete with microphone wind cover, PC software on CD, Serial cable,<br />

four type C size batteries, adjustment screwdriver, 120VAC adaptor and<br />

carrying case<br />

Applications:<br />

• Real time analysis of noise from any source such as machinery or vehicles<br />

•Monitor office or plant noise and store data for later reference and analysis<br />

•Maintain noise level statistics for internal and external audits<br />

•Perform machinery noise monitoring or use for noise reduction programs<br />

NIST it<br />

S<br />

<strong>Sound</strong> <strong>Level</strong><br />

SPECIFICATIONS<br />

Applicable standards IEC 60651 Type 2, IEC 60804 Type 2, IEC 1260-1995, ANSI S1.4 Type 2<br />

Microphone<br />

1/2-inch Electret condenser microphone<br />

Accuracy<br />

± 1.5dB (ref 94dB @ 1kHz)<br />

Measurement range<br />

30dB to 130dB<br />

Measurement function<br />

Lp , Leq , LE , Lmax , Lmin<br />

Frequency range<br />

25Hz ~ 10kHz<br />

<strong>Sound</strong> level meter display<br />

Numerical : 4 digits, up data cycle 0.5s, resolution 0.1dB<br />

Bar graph : Scale range 100dB , update cycle 0.125s, resolution 0.1dB<br />

Real time clock : Year, Month, Day, Hour, Minute, Second<br />

1/1- 1/3 Analyzer level range 70dB<br />

1/1 Octave and 1/3 Octave 1/1 Octave band center frequencies : (9 bands): 31.5Hz, 63Hz, 125Hz, 250Hz,<br />

band filters<br />

500Hz, 1kHz, 2kHz, 4kHz, and 8kHz.<br />

1/3 Octave band center frequencies : (27 bands) : 25Hz, 31.5Hz, 40Hz, 50Hz,<br />

63Hz, 80Hz, 100Hz, 125Hz, 160Hz, 200Hz, 250Hz, 315Hz, 400Hz, 500Hz, 630Hz,<br />

800Hz, 1kHz, 1.25kHz, 1.6kHz, 2kHz, 2.5kHz, 3.15kHz, 4kHz, 5kHz, 6.3kHz, 8kHz 10kHz<br />

Signal output<br />

AC output : 2 Vrms (at full scale): DC output : 10mVDC / dB<br />

Power<br />

Four type C size 1.5V batteries, External DC power: 6V, 1A<br />

Battery life<br />

Approx. 2hrs<br />

Dimensions & Weight<br />

13.6x3.9x2.4" (34.5x10x6 cm); 33.5oz (950g)<br />

Catalog No. Model Description Price<br />

EH407790 407790 Octave Band <strong>Sound</strong> Analyzer $3499.00<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

1144<br />

Davis Inotek Instruments<br />

www.davis.com


Digital <strong>Sound</strong> <strong>Meter</strong><br />

NIST it<br />

• Small size<br />

• High performance at a low cost<br />

• Real time display with min/max recording<br />

• Meets IEC 651, type 2 class<br />

• <strong>Level</strong> range display<br />

• Includes windscreen, battery, manual and<br />

calibration screwdriver<br />

SPECIFICATIONS<br />

<strong>Level</strong> range Low=32 to 80 dB Med.=50 to 100 dB High=80 to 130dB<br />

Resolution<br />

0.1dB<br />

Accuracy<br />

± 1.5dB<br />

Frequency weighting A, C<br />

Dynamic range 50dB<br />

Frequency range 31.5 Hz to 8kHz<br />

Dimensions<br />

9.1" x 2.1" x 1.3" (232 x 54 x 34 mm)<br />

Auxiliary outputs AC signal output<br />

Power source<br />

1 9V battery<br />

Catalog No. Model Description Price<br />

IT8925 DSM325 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> $149.00<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

Digital <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> with Backlight<br />

NIST it<br />

Model RS232KIT<br />

Catalog No. Model Description Price<br />

IT8924 DSM8922 Digital <strong>Sound</strong> <strong>Meter</strong> with Backlight $249.00<br />

IT8911 RS232CBL RS-232 Transfer Cable 29.00<br />

IT8912 RS232SFT Windows ® RS232 Software 45.00<br />

IT8913 RS232KIT RS-232 Interface Kit 69.95<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

• Monitor the sound levels from traffic noise, alarm systems and<br />

workplace machinery<br />

• Quasi-analog bar indicator: 1 dB display steps, 50 dB display range,<br />

updated every 50 ms<br />

• Measurement level range features 6 ranges<br />

• Multi-frequency calibration to ensure stability<br />

• Fast (125 msec.) or slow (1 sec.) settings<br />

• Min/max record with maximum hold<br />

• Optional RS-232 kit includes Windows ® software & cable<br />

• Background noise absorber filters ambient sound<br />

• Jumbo LCD display with backlight<br />

• Digital display with analog bargraph<br />

• Background noise absorber<br />

• A & C weighting selectable<br />

• Low battery indicator<br />

• Meets IEC 651, type 2 class<br />

SPECIFICATIONS<br />

Measurement level ranges<br />

Auto range<br />

Accuracy<br />

Digital display<br />

Analog output<br />

Measurement frequency range<br />

Power source<br />

Dimensions<br />

30 to 80dB, 40 to 90 dB, 50 to 100 dB,<br />

60 to 110 dB, 70 to 120 dB, 80 to 130 dB<br />

30 to 130 dB (35 to 139 for C weighting)<br />

± 1.5dB<br />

3-1/2 digit LCD with backlight<br />

AC: 0.707 Vrms (full scale);<br />

DC: 10 mV/dB<br />

31.5Hz to 8kHz<br />

1 9V battery<br />

10" x 3.1" x 1.5" (256 x 80 x 38 mm)<br />

S<br />

<strong>Sound</strong> <strong>Level</strong><br />

Davis Inotek Instruments<br />

www.davis.com<br />

1145


<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />

NIST it<br />

The Chameleon is a single instrument that<br />

adapts to the needs of both novice and advanced<br />

users. Every Chameleon comes standard<br />

with Feature Pack 1, providing the most<br />

basic functions of a sound level meter.<br />

Additional Feature Packs may be purchased<br />

separately to change the Chameleon’s<br />

functionality.<br />

Operational in 5 easy steps<br />

in 5 minutes or less<br />

• Step 1<br />

• Step 2<br />

• Step 3<br />

• Step 4<br />

• Step 5<br />

Turn ON — Press the ON/OFF button<br />

Calibrate — Press the CALIB button, insert the microphone<br />

into the calibrator, turn the calibrator on, let the displayed<br />

reading stabilize and press the CALIB button a second<br />

time. Remove the calibrator.<br />

Collect Data — Press the RUN/PAUSE button to begin<br />

storing data. Press the RUN/PAUSE button a second time<br />

to stop storing data.<br />

View Readings — Press the VIEW DATA button repeatedly to<br />

scroll through measurement data.<br />

Clear Memory — Press the CLEAR button. CLR appears on<br />

the display. Press the CLEAR button a second time and<br />

the memory is cleared.<br />

Pack 2 Measurement Data<br />

• SPL<br />

• Lpeak<br />

• Lmin<br />

• Battery Voltage<br />

• Lmax<br />

• Lavg (Leq)<br />

• Elapsed Time<br />

S<br />

SPECIFICATIONS<br />

Standard Pack 1<br />

Operating Range 40 to 140 dB<br />

Amplitude Resolution 0.1 dB<br />

A or C weighted<br />

Response Rate Fast, Slow or Impulse<br />

Data Provided<br />

SPL (<strong>Sound</strong> Pressure <strong>Level</strong>)<br />

Battery Voltage<br />

The data can be imported into other programs, such as Excel®, for data<br />

analysis and generating graphs and reports<br />

UL Listed<br />

C-UL Listed<br />

CE<br />

Battery<br />

9V Alkaline 1604A<br />

Display<br />

2.3 x 1.4 inch display with 3 1/2 digits and<br />

test descriptors<br />

Case size 3.1 x 1.75 x 7.6"<br />

Pack 3<br />

• SPL<br />

• Lmin<br />

• Lmax<br />

Pack 4<br />

• SPL<br />

• Lmin<br />

• Lmax<br />

• Lpeak<br />

• Battery Voltage<br />

• Lavg (Leq)<br />

• Lpeak<br />

• Battery Voltage<br />

• Lavg (Leq)<br />

• Elapsed Time<br />

• Amplitude<br />

Distribution<br />

• Elapsed Time<br />

• Time History<br />

Setup Options — Packs 2 ,3 & 4<br />

• Fast, Slow or Impulse<br />

• Calibration <strong>Level</strong><br />

• A or C Weighting<br />

• 3, 4 or 5 dB doubling<br />

<strong>Sound</strong> <strong>Level</strong><br />

Catalog No. Model Description Price<br />

QS139340 SLM1-MK Chameleon SLM Kit Pack 1 includes <strong>Sound</strong> <strong>Level</strong> meter CI-305 calibrator, wind screen and storage case $969.00<br />

for all accessories<br />

Field Upgrade Packs<br />

QS139341 Pack 2 Software upgrade with interface cable Converts Chameleon to an integrating SLM 289.00<br />

QS139342 Pack 3 Software upgrade with interface cable Converts Chameleon to an integrating SLM with Amplitude 396.00<br />

Distribution Data logging<br />

QS1393421 Pack 4 Software upgrade with interface cable Converts Chameleon to an integrating SLM with Time History 396.00<br />

Data logging<br />

QS139343 2135-2030-04 Windows Software 117.00<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

1146<br />

Davis Inotek Instruments<br />

www.davis.com


<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />

NIST it<br />

Quest’s new easy-to-use model 210 sound<br />

level meter offers basic measurement features<br />

in Type 2 accuracies at a great value.<br />

It is the perfect choice for many laboratory,<br />

community, military, and industrial measurement<br />

applications.<br />

The large LCD display provides readings in<br />

0.1dB increments as well as indicating a low<br />

battery (LOBAT) condition. The slide switches<br />

make the meters extremely easy-to-operate<br />

- even while wearing gloves.<br />

The durable red “granite-look” molded<br />

polymer case is lightweight and compact,<br />

making the 210 as red, rugged and reliable as<br />

they come.<br />

• User-Friendly Features<br />

A large, easy-to-read LCD display and simple slide switches combine<br />

for easy operation and viewing of data<br />

• Simple one-button calibration<br />

It’s as easy as a press of a button. No tools or screwdrivers required<br />

• Portable design<br />

The “granite-look” molded polymer case is extremely lightweight and<br />

compact. Only 8.4 oz. (238 g) including the battery<br />

• RFI Shielding<br />

The 210 is housed in a rugged RF shielded case<br />

• Output Jack<br />

Connection to peripheral devices, such as recorders and oscilloscopes,<br />

is made possible with an output jack<br />

• Slide-in Battery Compartment<br />

To eliminate battery connection failure, the meter has a unique slide-in<br />

battery compartment<br />

SPECIFICATIONS<br />

Standards<br />

Model 210 Type 2<br />

ANSI S1.4-1983 (R1997), IEC 60651-1979 EN60651, CE Mark<br />

Measurement Range<br />

40 to 130 dBA<br />

Frequency Weighting Networks<br />

“A” weighting<br />

<strong>Meter</strong> Response<br />

Fast & Slow<br />

Microphone<br />

Non-removable prepolarized condenser (electret) microphone cartridge mounted in plastic 0.52” (13.5 mm)<br />

diameter nose cone<br />

Temperature Range Operation 14°F to 122°F (0°C to + 50°C)<br />

Storage -4°F to 140°F (-20°C to + 60°C) less batteries<br />

Effect of Electromagnetic Fields Negligible<br />

Operating Humidity<br />

0 to 95% relative humidity, non-condensing<br />

Batteries<br />

One 9-volt alkaline battery, approximately 25-30 hours<br />

Size<br />

2.81” w 7.6” x 1.3” (7.13 cm x 19.3 cm x 3.3 cm)<br />

Weight<br />

8.4 oz. (238 g ) including battery<br />

Pending Approvals<br />

UL, CSA, EEx<br />

Catalog No. Model Description Price<br />

QS139201 210 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> with soft pouch $390.00<br />

QS139202 59-536 Calibrator kit includes QC-10 calibrator with 56-990 calibration adapter 469.00<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

S<br />

<strong>Sound</strong> <strong>Level</strong><br />

Davis Inotek Instruments<br />

www.davis.com<br />

1147


Basic and Integrating <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s<br />

NIST it<br />

Quest’s 1200 and 2200 Impulse Integrating<br />

<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s offer superior noise measurements<br />

and analysis at a competitive price. The<br />

1200 provides precision Type 1 accuracy while the<br />

2200 offers Type 2 accuracy.<br />

Quest’s new easy-to-use 1100 and 2100 sound<br />

level meters offer basic measurement features in<br />

precision Type 1 and Type 2 accuracies.<br />

Model 1100/1200<br />

Model 2100/2200<br />

Models 1100 and 2100<br />

• Frequency Weighting Options<br />

• Wide, Selectable dB Range<br />

• Two Operating Modes<br />

Models 1200/2200<br />

• Weighting Options - Choose between “A”, “C”, or “Z” (Linear)<br />

weighting for all measurements<br />

• Selectable Exchange Rates<br />

• Wide Operating Range<br />

All Models<br />

• A large, easy-to-read LCD display and simple slide switches combine<br />

for easy operation and viewing of data<br />

• Simple One-Button Calibration<br />

• Portable Design<br />

• RFI Shielding - Housed in a rugged RF shielded case<br />

• Slide-in Battery Compartment<br />

• Output Jack<br />

S<br />

SPECIFICATIONS<br />

Models 1100/2100 Models 1200/2200<br />

Standards Type 1/Type 2 Type 1/Type 2<br />

Measurement Ranges 30 to 140 dBA 30 to 140 dBASPL<br />

40 to 140 dBC 43 to 143 dBA Peak<br />

Frequency Weighting “A” and “C” Weighting A, C, or Z<br />

<strong>Meter</strong> Response Fast and Slow Fast, Slow, Impulse or Peak<br />

Microphone<br />

Field replaceable .52 inch diameter prepolarized condenser (electret) microphone<br />

Temperature Operating Range<br />

14°F to 122°F (-10°C to + 50°C)<br />

Effect of Electrostatic/Electromagnetic Fields Negligible<br />

AC/DC Output<br />

Both AC/DC outputs are provided through a single 3.5 mm stereo jack. Output impedance is 1000 ohm.<br />

Each 0.167 V change equals 10 dB (1V/60dB)<br />

Operating Humidity<br />

0 to 95% relative humidity, non-condensing<br />

Batteries<br />

One 9-volt alkaline battery, approximately 25-30 hours<br />

<strong>Sound</strong> <strong>Level</strong><br />

Catalog No. Model Description Price<br />

QS139302 1100-20 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Kit includes QC-20 Calibrator, wind screen and storage case $1,680.00<br />

QS139303 1100R-20 Remote SLM Kit includes remote microphone, QC-20 calibrator and storage case 1,782.00<br />

QS139304 2100-10 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Kit includes QC-10 calibrator, wind screen and storage case 1,050.00<br />

QS139305 2100R-10 Remote SLM Kit includes remote microphone, QC-10 calibrator, wind screen and storage case 1,150.00<br />

QS139308 1200-20 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Kit includes WS-7 windscreen, calibrator adapter, storage case and QC-20 Calibrator 2,710.00<br />

QS139309 1200R-20 Remote <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Kit includes WS-7 windscreen, calibrator adapter, storage case, and QC-20 Calibrator 2,812.00<br />

QS139306 2200-10 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Kit includes WS-7 windscreen, calibrator adapter, storage case and QC-10 Calibrator 1,460.00<br />

QS139307 2200R-10 Remote <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Kit includes WS-7 windscreen, calibrator adapter, storage case and QC-10 Calibrator 1,562.00<br />

QS2015 59-733 Remote microphone cable with connectors 10 ft. 130.00<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

1148<br />

Davis Inotek Instruments<br />

www.davis.com


Integrating Datalogging <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s<br />

NIST it<br />

Enables the Use of One Instrument to<br />

Analyze “A”, “C” or Linear Weighted<br />

<strong>Sound</strong> <strong>Level</strong>s Using a Choice of<br />

Exchange Rates<br />

• User-Controlled Logging:<br />

The user is in ultimate control<br />

of what is logged, displayed<br />

and printed, selecting from<br />

SPL, Leq, LavQ, TWA,<br />

Lmax,Lmin,LDN, CNEL,<br />

Pa2Hrs, SEL, exceedance<br />

levels, and time information<br />

•Wide Selection of Studies:<br />

Manual-,automatic-, or<br />

threshold-triggered studies<br />

provide the user with versatile<br />

control<br />

• Response and Weighting<br />

Options:<br />

The 2900 provides fast, slow,<br />

peak and impulse response<br />

with “A”, “C”, or Linear<br />

weighting<br />

• Integration and Datalogging<br />

Capabilities<br />

• Battery-Protected Memory<br />

• Optional Octave Filter<br />

•Printer/Computer Interface<br />

• Optional Parallel Interface<br />

Model<br />

2900<br />

®<br />

MODEL 2900 SPECIFICATIONS<br />

Standards ANSI S1.4-1983, Type 2; IEC 651-1979, Type 2; IEC 804-1985, Type 2<br />

Measurement 20-140dB in seven 60dB ranges<br />

<strong>Meter</strong> only: 30 to 140 dBA. With Filter Sets: 0 to 140 dB (Other levels possible<br />

with optional microphones;noise floor varies depending on microphone type and<br />

filter selection)<br />

Exchange Rates Integrations may be performed with 3,4,5 or 6 dB exchange rate<br />

Microphones Removable precision 0.5" pre polarized condenser (electret) microphone is<br />

standard<br />

Preamplifier Directly accepts 0.50-inch microphone. Input impedance is greater than 1 Gohm<br />

in parallel with 47pF. Removable, the pre-amp will drive up to 100 feet of cable<br />

with no signal loss<br />

AC Output 3.16V RMS at full scale. (3.8V RMS maximum) 3.2 Kohm output impedance.<br />

1<br />

⁄8 " phone jack<br />

DC Output 0 to 1.00V DC; 60dB span. Each 0.167 change equals 10dB. 1 Kohm output<br />

impedance. 3.5mm phone jack<br />

COMM Output RS-232 serial output to printers or computers. Selectable data rates of 300<br />

through 19200 baud. ASCII character format. Optional parallel printer interface<br />

Temperature range<br />

Operating -10°C to +50°C<br />

Operating Humidity 0 to 95%, non-condensing DC Output<br />

0 to 1.00V DC; 60dB span. Each 0.167 change equals 10dB. 1 Kohm output<br />

impedance. 3.5mm phone jack<br />

Effect of Magnetic Fields A magnetic field of 1 Oersted (80A/m) at 60 Hz produces a maximum<br />

reading of 40dB on Linear weighting<br />

Effect of Electrostatic Fields Negligible<br />

Batteries<br />

Two 9V alkaline batteries will provide approximately 16 hours of continuous<br />

operation (9 hours with optional filter set).<br />

S<br />

Catalog No. Model Description Price<br />

QS2900 2900 Type 2 (General Purpose) Integrating/ $2,005.00<br />

Datalogging <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />

Accessories<br />

QS138644 QC-10 Calibrator for Model 2900 435.00<br />

QS2010 OB100 Optional Octave filter:1/1 865.00<br />

QS1389941 OB300 Optional Octave filter:1/1 or 1/3 1,780.00<br />

QS2012 QS-ONE 56-999 software with cable 545.00<br />

QS2013 56-999 Serial interface cable 95.00<br />

QS2014 56-875 Parallel cable 143.00<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

<strong>Sound</strong> <strong>Level</strong><br />

Davis Inotek Instruments<br />

www.davis.com<br />

1149


Precision Integrating <strong>Sound</strong> <strong>Meter</strong> & Calibrator<br />

NIST it<br />

Modern microprocessor technology and an efficient practical<br />

design make this instrument extremely versatile and easy to<br />

use, at a very reasonable price.<br />

Both manual and automatic octave band analysis are provided<br />

by the optional filter sets. The Model 1800 also can be interfaced<br />

with the analysis of occupational, environmental, and other<br />

noise measurements.<br />

Precision accuracy, outstanding features and versatility in a<br />

durable lightweight housing, coupled with the highest quality<br />

and support make the Model 1800 the first choice in sound level<br />

meters for virtually any application.<br />

• Type 1 accuracy for precision noise measurement and statistical analysis<br />

• For industrial, community, R & D, and audiometric applications<br />

• Easy to read LCD digital readout plus additional Quasi-Analogue display<br />

• AC and DC outputs for recording<br />

• RS-232 digital outputs to printers, computers, and NL-15 data logger<br />

• Modular design allows choice of 1/1 and combination 1/3-1/1 octave filter sets<br />

• Optional accessory allows vibration measurement and analysis<br />

• Direct readout of SPL, Leq, SEL, Peak, Impulse, Lmax, Lmin, <strong>Level</strong>s and Run Time<br />

• NIST Certification Included<br />

®<br />

S<br />

<strong>Sound</strong> <strong>Level</strong><br />

Catalog No. Model Description Price<br />

QS138180022 1800-20 Precision Integrated SLM with $3,535.00<br />

QC-20 calibrator<br />

Options<br />

QS1389941 OB300 Octave Band Filter, 1/3 - 1/1 1,780.00<br />

QS2010 OB100 Octave Band Filter, 1/1 865.00<br />

QS1389944 VA-508C Vibration assembly for vibration velocity 980.00<br />

displacement & acceleration<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

SPECIFICATIONS<br />

MODEL 1800 SOUND LEVEL METER<br />

Range<br />

<strong>Meter</strong> only: 20 to 140dB. With filter sets: 0 to 140dB. (Other levels possible with optional micro<br />

phones; noise floor varies depending on microphone type and filter selection)<br />

Standards Meets or exceeds ANSI S1.4 Type 1 and relevant section of IEC 651 Type 1 (1) and IEC 804<br />

Microphones<br />

Removable precision 1 ⁄2" prepolarized condenser (electret) microphone is standard. Optional<br />

1<br />

⁄2" and 1" condenser and other microphones available<br />

Preamp<br />

Removable; input impedance is greater that 1G ohm in parallel with 2 pf. Preamp will drive up<br />

to 100 feet of cable<br />

Polarization<br />

Regulated 200VDC ±2% when using ordinary condenser microphones, switched off when<br />

using prepolarized condenser (electret) microphones<br />

<strong>Meter</strong> Input<br />

Input impedance is 1 MΩ in series with 0.1 MFD. Maximum sinusoidal input voltage is 10V RMS<br />

AC Output<br />

3.16V RMS at full scale (60dB). (3.8V RMS maximum) Output impedance is 32K Ω<br />

DC Output<br />

0 to 1.00VDC; 60dB span. Each 0.167V change equals 10dB<br />

Print Output<br />

Serial output to printers or computers using RS-232 voltage levels. Selectable baud rates of<br />

300, 600, 1200, or 2400. ACSII character format<br />

Data Output<br />

Output transmission of real-time digital data st rate of 16 times per second using RS-232<br />

voltage levels to Quest data loggers<br />

Detector<br />

True RMS; 63dB pulse range<br />

Overload Indication Displays overload condition via annunciator on LCD and annotates them on printout<br />

Frequency Range 4Hz (-3dB) to 50kHz (-3dB) or linear weighting<br />

Frequency Weighting A, B, C, and Linear. When using OB-100 or OB-300 filter sets, any one of the weightings<br />

Networks<br />

may be selected<br />

Display<br />

3 1 ⁄2 Digit :Liquid Crystal Display with additional Quasi-Analogue 60dB indicator in 2dB incre<br />

ments. <strong>Level</strong> display to 0.1dB resolution. Time display of Min:Sec or Hr:Min. Annunciators for<br />

battery check, hold, run, and overload indications<br />

<strong>Meter</strong> Response<br />

Slow, fast, impulse, and peak (onset time constant less than 50µs.) (Peak measurements may<br />

be A, B, C or Linear)<br />

Modes of Operation As an integrated sound level meter, calculates sound pressure level (SPL), maximum level<br />

(MAX), minimum level (MIN), sound exposure level (SEL), and equivalent level (Leq). Also<br />

measures peak and impulse levels<br />

Temperature Range Operation: -10°C to +50°C. Storage (less batteries): -20°C to +60°C<br />

Effect of Magnetic Fields A magnetic field of 1 Oersted (80A/m) at 60Hz produces a maximum reading of 40dB on linear<br />

weighting<br />

Effect of Electrostatic Fields Negligible as long as protection grid is kept on microphone<br />

Batteries<br />

Two 9-volt batteries (NEDA 1604A-Alkaline) will provide approximately 20 hours of continuous<br />

operation (10 hours with optional filter sets) at 25°C<br />

Tripod Mount<br />

Threaded insert on back of meter accepts a standard 1 ⁄4-20 tripod mounting screw<br />

Size<br />

3.3" x 8.2" x 1.8" (84 x 208 x 47mm) not including preamp height<br />

Weight<br />

24 oz. (680 grams) including preamp, half-inch microphone, and batteries<br />

MODEL OB-300, 1/3 - 1/1 OCTAVE FILTER SET<br />

Standards<br />

ANSI S1.11, Order 3 AND IEC R225<br />

Center Frequencies 33 frequencies from 12.5Hz to 20kHz<br />

Frequency Selection Full manual control or automatic sequential stepping through each frequency band<br />

Power Source<br />

<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />

Size<br />

3.3" x 4.2" x 1.8" (84 x 107 x 47mm)<br />

Weight<br />

9 ounces (255 grams)<br />

MODEL OB-100, 1/1 OCTAVE FILTER SET<br />

Standards<br />

ANSI S1.11, Order 3 and IEC R225<br />

Center Frequencies 10 frequencies from 31.5Hz to 16kHz<br />

Frequency Selection Full manual control or automatic sequential stepping through each frequency band<br />

Power Source<br />

<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />

Size<br />

3.3" x 2.8" x 1.8" (84 x 71 x 47mm)<br />

Weight<br />

6 ounces (170 grams)<br />

1150<br />

Davis Inotek Instruments<br />

www.davis.com


<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />

NIST it<br />

The CEL-400 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s are an ergonomic,<br />

modular and effective interpretation of the classic integrating<br />

instrument. The instruments are available as<br />

either direct read out (CEL-440) or datalogging (CEL-<br />

480) versions, in either Type 1 or 2 configurations. Both<br />

instruments provide read out and data storage (CEL-<br />

480) of full 1/3 Ocatve Band Frequency levels, with an<br />

effective dynamic range of 20 to 140 dB(A). Instruments<br />

can display information as either numerical values or<br />

frequency graphs on screen, including specific information<br />

on derived acoustic values.<br />

Power comes from 4 "AA" size batteries, which give<br />

the user up to 25 hours of continuous operation. Each<br />

sound level meter kit includes the instrument, a calibrator,<br />

windscreen and manual in a hard case. The<br />

CEL-480 kit also includes software and a download cable.<br />

All instruments meet the relevant ANSI S1.4 and<br />

IEC standard requirements.<br />

• Advanced modular technology<br />

provides a choice of models<br />

and a clear upgrade path for<br />

future proof operation<br />

• A choice of broad band and frequency<br />

analysis modes offers a<br />

solution to a wide range of the<br />

most common noise measurement<br />

problems<br />

• Manual or automatic operation<br />

depending on model<br />

• Intuitive user control with icon<br />

based keypad and graphic<br />

screen<br />

• On board memory eliminates<br />

the need for hand written<br />

reports<br />

• Download capability to printers<br />

and computers<br />

• Multi-lingual operation<br />

SPECIFICATIONS<br />

Electro-Acoustic<br />

Applicable Standards<br />

IEC 1672 199X class 1 and 2, ANSI S1.4, DIN 45657, IEC<br />

1260 class 1<br />

Slow, Fast and Impulse<br />

Time Weightings<br />

Frequency weightings<br />

rms & peaks<br />

A, C and Z (unweighted)<br />

Amplitude weighting Q=3 plus one from Q=4 or 5 or none<br />

Dynamic span<br />

70 dB per range<br />

Measurement ranges 140, 130, 120, 110, 100, 90 dB for FSD<br />

Noise floor 20 dB (A) type 1, (25 dB (A) type 2)<br />


<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s<br />

NIST it <br />

Digital Impulse <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>, Model CEL 254<br />

The CEL-254 Digital Impulse <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> is specially designed<br />

to meet the sound survey needs of industrial hygienists and safety professionals.<br />

The CEL-254 uses a large digital display with full 0.1dB resolution to<br />

guarantee easy, precise reading.<br />

The sound level meter is equipped with both “A” and “C” frequency<br />

weightings to take advantage of the increasing use of hearing protection<br />

Noise Reduction Rating (NRR) which simplifies the selection of Hearing<br />

Protectors.<br />

Just two measurement ranges, both covering a 70dB span, are needed<br />

to achieve a 30dB-135dB(A) total measurement span so that a single<br />

range of 65dB-135dB is available for industrial surveys.<br />

The meter complies with both the IEC 651 and ANSI S1.4 1983 in the<br />

Type 2 categories by providing both Fast and Slow response times. In addition,<br />

an Impulse response is available for those territories with extra<br />

legislative control over impulsive noise. The Impulse response is normally<br />

used in conjunction with the Maximum Hold function and this combination<br />

is equipped with a rapid reset facility. To optimize measuring opportunities<br />

“maximum hold” is also operational on both Fast and Slow responses.<br />

Digital <strong>Sound</strong> Survey <strong>Meter</strong>, Model CEL 231<br />

The CEL-231 is a simplified version of the CEL-254 maintaining much<br />

of the specification. Fast and Slow time weightings are provided along<br />

with “A” frequency weighting and a measurement range of 30dB(A) to<br />

135dB(A). It will appeal to Safety Engineers and Occupational workers<br />

who require an easy-to-use survey instrument to check whether industrial<br />

noise exposure areas require more detailed investigation.<br />

S<br />

<strong>Sound</strong> <strong>Level</strong><br />

Catalog No. Model Description Price<br />

PR95013 CEL231 Digital <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> $345.00<br />

PR95020 CEL231K1 Digital <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> Kit 670.00<br />

with Calibrator<br />

PR95014 CEL254 Digital Impulse <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> 535.00<br />

PR95021 CEL254K1 Digital Impulse <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> 860.00<br />

Kit with Calibrator<br />

Kits include: meter, calibrator, windscreen, case<br />

PR95016 CEL282 <strong>Sound</strong> <strong>Level</strong> Calibrator 225.00<br />

PR95017 CEL4672 Windscreen 10.00<br />

PR95018 CEL5894 Carrying Case 90.00<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

SPECIFICATIONS<br />

Standardization ANSI S1.4-1983 Type 2; IEC 651 Type 2<br />

Accuracy ± 1dB per ANSI S1.4-1983 3.2<br />

Measuring Range 30-135 dBA<br />

Upper Limit 125 dB RMS for signals with crest factor >3;<br />

121 dB RMS for signals with crest factor >5<br />

(CEL-254 only)<br />

Overload<br />

Pre-weighting detector with 2 second<br />

dwell time (CEL-254 only)<br />

Dynamic Range 70dBA<br />

Frequency Weightings A and C (CEL 254); A (CEL-231)<br />

Time Weightings Slow, Fast, and Impulse (CEL-254); Slow and<br />

Fast (CEL-231)<br />

Functions<br />

SPL (<strong>Sound</strong> Pressure <strong>Level</strong>),<br />

L MAX (Maximum <strong>Sound</strong> <strong>Level</strong>),<br />

Low Battery Indicator<br />

Battery Voltage X 10 (CEL-254 only),<br />

SPL (<strong>Sound</strong> Pressure <strong>Level</strong>) (CEL-123 only)<br />

Max. Hold Impulse Resp. Decay < 0.2 dB/min. (CEL-254)<br />

Microphone<br />

Electret Condenser<br />

Display<br />

3 1 ⁄2 digit, 12.7mm high character, LCD<br />

Auxiliary Outputs AC conditioned 7.25V RMS FSD.<br />

Minimum load impedance 39KΩ. DC log RMS<br />

output nominally 25mV/dB. Minimum load<br />

impedance 27KΩ<br />

Batteries<br />

4 X AAA Manganese Alkaline<br />

1152<br />

Davis Inotek Instruments<br />

www.davis.com


<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s<br />

NIST it<br />

<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> 886-2<br />

•Features fast or slow response<br />

•AC and DC outputs, tripod mount and analog meter<br />

• Detachable microphone<br />

• 40-140 dB<br />

• Meets ANSI S1.4-1983; ANSI S1.4-1992<br />

•Frequency = 1000 Hz at 94dB on 90dB range<br />

• “A”, “B”, “C” ext. filter for flat response<br />

• 2-1/2” dial dialog meter, pivot and jewel movement<br />

• 9V alkaline battery provides approximately 40 hours use<br />

897<br />

886-2<br />

884-2 899<br />

<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> 884-2<br />

• Identical to the 886-2 but only offers “A” weighting which closely<br />

corresponds to the human ear<br />

• 40-140 dB<br />

• Meets ANSI S1.4-1983; ANSI S1.4-1992<br />

• “A” ext. filter for flat response<br />

•Frequency = 1000 Hz at 94dB on 90dB range<br />

• 2-1/2”dial dialog meter, pivot and jewel movement<br />

• 9V alkaline battery provides approximately 40 hours use<br />

<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> 899<br />

• Offers choice of fast, slow, and impulse response<br />

•Provides maximum measurement versatility with A, B, and C weighing curves<br />

•AC and DC outputs to drive scopes, recorders and other external<br />

analysis equipment<br />

• 40 to 140 dB<br />

• Meets ANSI S1.4-1983; ANSI S1.4-1992<br />

•Frequency = 1000 Hz at 94dB on 90dB range<br />

• “A”, “B”, “C” ext. filter for flat response<br />

• 2-1/2”dial dialog meter, pivot and jewel movement<br />

• 9V alkaline battery provides approximately 40 hours use<br />

<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>/Dosimeter 897<br />

• Meets ANSI S1.4-1983, D1.25-1978 and IEC 651-1979<br />

specifications<br />

• Selectable ranges and threshold levels<br />

• Selectable exchange rates and criterion levels<br />

• Built-in datalogger and computer/printer output<br />

•Ideal for OSHA and IEC surveys<br />

897 Unit Includes:<br />

•Printer Cable<br />

•AC Adaptor<br />

• Microphone Clip<br />

• Nose Cone<br />

• Wind Screen<br />

• Screwdriver<br />

• Wrench<br />

•NICd Battery<br />

SPECIFICATIONS<br />

<strong>Sound</strong> <strong>Level</strong> Mode Ranges<br />

Accuracy<br />

Dynamic Range<br />

Frequency Response Weighting<br />

Frequency Range<br />

Dosimeter Mode Threshold <strong>Level</strong><br />

Criterion <strong>Level</strong><br />

Criterion Duration<br />

Exchange Rate<br />

Elapsed Time<br />

Recording Time<br />

Printer Interface<br />

Size/Weight:<br />

SMS-2 Kit Includes:<br />

• All accessories included in the 897 Unit<br />

• RS-232-C Serial Cable Calibrator<br />

• 9V Alkaline Battery (for Calibrator)<br />

• 887-2 Calibrator<br />

50 to 100dB, 80 to 30dB<br />

True RMS, type S2<br />

Selectable 50 to 100dB and 80 to 130dB<br />

“A” Weighting<br />

20 Hz to 8 Hz<br />

Selectable from 50 to 99dB in1dB<br />

increments<br />

Selectable 70, 80, 84, 85, or 90dB<br />

8 Hours<br />

Selectable 3, 4, or 5dB<br />

Displays either Hours:Minutes, or<br />

Minutes:Seconds,<br />

up 99 Hours, 59 Minutes, 59 Seconds<br />

31 Hours Maximum<br />

Centronics and RS-232<br />

6.8 x 3.1 x 1.1HWD/18 ozs;<br />

172 x 80 x 28mm HWD/500g<br />

S<br />

Catalog No. Model Description Price<br />

SE65755 40004 886-2 Multi-Weight <strong>Sound</strong> <strong>Level</strong> meter only $592.00<br />

SE65756 40007 886-2 Kit Multi-Weight <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> w/Calibrator 853.60<br />

SE65757 40003 884-2 <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> 439.90<br />

SE65758 40006 884-2 Kit <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> w/Calibrator 678.90<br />

SE65759 40005 Impulse <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> 741.50<br />

SE65760 40008 Impulse <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong> w/Calibrator 990.60<br />

SE659971 12645 897 Universal Noise Dosimeter Unit 892.00<br />

SE659973 12646 SMS-2 Universal Noise Dosimeter Kit 1,251.30<br />

NISTSD4 — NIST Traceable Certificate with Data for SLM `285.00<br />

<strong>Sound</strong> <strong>Level</strong><br />

Davis Inotek Instruments<br />

www.davis.com<br />

1153


Noise Dosimeters/Datalogging Dosimeters<br />

Q200 is a powerful dosimeter used for display-only applications<br />

Q300 is a highly versatile, multi-function datalogging dosimeter<br />

Q400 is a full featured, advanced datalogging dosimeter<br />

NIST it<br />

S<br />

<strong>Sound</strong> <strong>Level</strong><br />

1154<br />

Model Q200<br />

• Easy-to-Read Display<br />

• Simple Operation<br />

• Battery Changes are a snap<br />

•Instructions where you need them<br />

• Security to protect your work<br />

Two levels are provided to lock out set-up charges or all display functions.<br />

Accidental turn-off or reset are also prevented by five second function count<br />

down<br />

•Tough, Compact Case<br />

Cast aluminum housing provides durability, tested RF protection and intrinsic<br />

safety<br />

Model Q300<br />

•Instructions where you want them<br />

• Log all the information you need including sound levels and peaks<br />

• Meet all the requirements<br />

Three simultaneous dosimeter studies using independent threshold, criteria<br />

and exchange rate assures you will have what you need today and tomorrow<br />

• The power to do the right job<br />

• Long battery life<br />

• See it now, print it later<br />

• The LCD display lets you see what you want now, and parallel/serial output<br />

allows direct printing of all the details<br />

• Security<br />

•Run it even if you are not there<br />

•Auto on/off and auto run time<br />

•Paperless surveys<br />

• The unique event function makes surveying a variety of locations easy. Just<br />

keep track of where you went, and the Q-300 will do the rest, keeping<br />

information separated so you can analyze each location at your convenience<br />

Model Q400<br />

• Two true independent analog circuits<br />

• Simultaneous “A” and “C” measurements—allows for “C” minus “A” calculations<br />

• Field Selectable - Projected dose periods, Threshold levels, Upper limit levels,<br />

Exchange rates, Criterion levels<br />

• Real time clock with automatic start/stop<br />

• Up to 999 (or 100 hours) stored events<br />

• Pre and post calibrations on printout<br />

SPECIFICATIONS<br />

Models Q200 & Q300<br />

Standards ANSI S1.25-991, ANSI S1.4-1983: Type 2; IEC 651-1979,<br />

IEC 804-1985: Type 2; IEC 1252-1993<br />

Measuring Range<br />

Detector<br />

Data Output (Q300 only)<br />

Microphone<br />

Battery<br />

Temperature<br />

Humidity<br />

Electromagnetic<br />

Field Effects<br />

Model Q400<br />

Standards<br />

Operating Range<br />

Dynamic Range<br />

Exchange Rates<br />

Criterion <strong>Level</strong>s<br />

Display<br />

Output<br />

Size/Weight<br />

Davis Inotek Instruments<br />

40-110dB or 70-140dB<br />

True RMS, 63 dB Pulse Range<br />

Uses interface modules connected to the microphone<br />

connector. Parallel operation or selected baud<br />

8mm Shoulder-Mount, Type 2. One piece system: cable,<br />

connector, and microphone<br />

Single 9V alkaline provides approximately 48 hours of<br />

operation<br />

-10° to + 50°C operating<br />

-20° to + 60° storage (battery removed)<br />

0 to 95% non-condensing<br />

Negligible below 50 Oersteds at 50 to 60 Hz. Tested for RF<br />

the frequency range of 10 MHz to 500 MHz<br />

All applicable ANSI and IEC<br />

40-140dB<br />

100dB<br />

3, 4, 5, 6dB, user selectable<br />

Settable between 40-140dB<br />

Graphic LCD with 3 line capability<br />

RS-232/Parallel<br />

5.5” x 2.75” x 1.3” / 15.5 ounces<br />

®<br />

Model<br />

Q300<br />

Model<br />

Q400<br />

Catalog No. Model Description Price<br />

QS200 Q200 Display-only Noise Dosimeter $1,300.00<br />

QS300 Q300 Datalogging Noise Dosimeter 1,890.00<br />

QS3432081 Q400 Data Logging Noise Dosimeter<br />

with printer cable<br />

2,250.00<br />

QS138644 QC-10 Calibrator 435.00<br />

NISTSD4 — NIST Traceable Certificate 285.00<br />

with Data<br />

www.davis.com


Convertible Noise Dosimeter/<strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />

NIST it<br />

The CEL-300 Series "Convertible" dosimeters<br />

and sound level meters offer the ability to make<br />

noise measurements in many different environments.<br />

The units are called "Convertible" because<br />

the user can turn a dosimeter into a sound level<br />

meter and back again, simply by inserting a different<br />

microphone. This provides the most flexibility<br />

in a single unit and reduces the cost for the<br />

user.<br />

In dosimeter mode, instruments are delivered<br />

pre-programmed with the operating parameters<br />

to measure noise dose to the relevant standards<br />

(ie OSHA), and measure from 30 to 140 dB in<br />

three 70 dB ranges. Whilst the CEL-320 provides<br />

summary statistics for download, the CEL-360<br />

stores individual readings to provide a full time<br />

history.<br />

In sound level meter mode, instruments possess<br />

up to 20 configurable operating modes, which can<br />

be user programmed to suit any specific task.<br />

Simply selecting the mode and pressing "run"<br />

starts the measurement and displays current information.<br />

Download all the data to the PC for<br />

subsequent analysis.<br />

Both models are suitable for workplace noise<br />

monitoring, simple hand-held noise surveys and<br />

long term boundary monitoring. They are rugged,<br />

lightweight, easy to use and conform to both ANSI<br />

and IEC standards.<br />

SPECIFICATIONS<br />

Standards IEC 1252, 651, 804<br />

ANSI S1.4, S1.25<br />

EN 50081-1, 50081-2, 50082-1, 50082-2<br />

Measurement Range 30 - 140 (in 70 dB ranges)<br />

Microphone<br />

Electret, on 0.8m cable, Type 2 (dosimeter)<br />

Electret, 75mm stalk, Type 2 (SLM)<br />

Battery<br />

9 volt, Alkaline<br />

Operating life<br />

Approx. 40 hours<br />

Measurement runs 50<br />

Threshold levels 2 (70 - 90 dB in 1 dB steps)<br />

Frequency weightings A, C, linear 20 Hz - 20 kHz<br />

Time weightings Fast, Slow, Impulse, Peak<br />

Amplitude weightings 3, 4, 5, 6 dB exchange rates<br />

Displayed information Lp, LAeq, LAE, Leql, Lav, Lmx, Lmn, Lpeak,<br />

%Dose1 & 2 (actual & projected), TWA, LEPd, TWAv, LEPv, Duration,<br />

Date, Time, Run #, Wait, Pause, Battery state<br />

Dimensions (excl mic) 4.8 x 2.6 x 1.2 in<br />

Weight<br />

11 oz.<br />

Data Storage (CEL-360 only)<br />

Memory size<br />

>200,000 data points<br />

Profiles per period 10 (max)<br />

Profile intervals 1 sec to 60 min<br />

Fixed duration timers 5 min to 24 hours<br />

Catalog No. Model Description Price<br />

CEL1001 CEL-320/K1 Dosimeter with calibrator, wind $1,315.00<br />

screen & carrying case<br />

CEL1002 CEL-320D1/K1 Same as above with software 1,585.00<br />

and download cable<br />

CEL1004 CEL-360/K1 Logging dosimeter with calibrator, 1,995.00<br />

wind screen, carrying case,<br />

software and download cable<br />

CEL1006 CEL-425 Microphone to convert to 175.00<br />

sound level meter<br />

NISTSD4 — NIST Traceable Certificate 285.00<br />

with Data<br />

S<br />

<strong>Sound</strong> <strong>Level</strong><br />

Davis Inotek Instruments<br />

www.davis.com<br />

1155


Audio Dosimeters<br />

AMETEK MARK Series audio dosimeters are designed for accuracy,<br />

reliability and ease-of-use. Available in three models, these<br />

extremely portable and lightweight instruments are convenient and<br />

easy to wear. They can also be used as <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong>s.<br />

The MARK Series feature simple pushbutton operation. Press a<br />

pushbutton and you sequentially display sampled data without disrupting<br />

the sampling process. Status indicators allow the user to<br />

see at a glance that the unit is operating or if the battery is needing<br />

to be charged. The instruments also include a large, easy-to-read<br />

display. A microphone boom is included allowing the instrument to<br />

be used in the sound meter mode.<br />

MARK Series dosimeters can be used with the AMETEK CPI PLUS<br />

computer interface and Data Logger allowing data to be downloaded<br />

to your personal computer.<br />

The MARK Series are extremely lightweight and comfortable to<br />

wear. Units weigh on 9 ounces (250 grams). They feature an<br />

impact resistant housing with tamper-resistant, lockable cover.<br />

There are no exposed keypads. The MARK Series feature field<br />

replaceable microphones that eliminate the need for time-consuming<br />

factory returns. And their commonality of components allow<br />

users to upgrade their MARK Series dosimeter with added features<br />

as their needs expand.<br />

• Meets MSHA 2G safely approval UL listed<br />

- Class 1: C, D<br />

- Class II: E, F, G<br />

- Class III: Hazardous locations<br />

- FM<br />

- CSA<br />

• Simple pushbutton operation<br />

• Data export capability to personal computer<br />

• Lightweight, convenient to use<br />

• Dosimeters may be upgraded with new functions<br />

• Complete noise monitoring kits<br />

S<br />

<strong>Sound</strong> <strong>Level</strong><br />

SPECIFICATIONS<br />

Features Mark 1 Mark 2 Mark 3<br />

Time Standard Standard Standard<br />

Stand By Standard Standard Standard<br />

Dose % Standard Standard Standard<br />

Lavg Standard Standard Standard<br />

SLM Standard Standard Standard<br />

Lmax Standard Standard Standard<br />

DOSE % 90 dB Threshold Optional Standard Standard<br />

Lavg 90 dB Threshold Optional Standard Standard<br />

Time Lmax Optional Standard Standard<br />

Fast Lmax Optional Standard Standard<br />

Projected 8-hour DOSE Optional Standard Standard<br />

Time of > 115 dB Optional Standard Standard<br />

Lavg 1-minute Data Optional Optional Standard<br />

Lavg Time History Optional Optional Standard<br />

Lavg Histogram Optional Optional Standard<br />

TO ORDER, SEE NEXT PAGE ➡<br />

1156<br />

Davis Inotek Instruments<br />

www.davis.com


NIST it<br />

SPECIFICATIONS<br />

MK1 MK2 MK3 AC94 AC1<br />

Operating Range 80-148 dB 94.0 dB<br />

Operating Range 80-140 dB 940.0 dB<br />

Selectable 60-120 dB 114.0 dB<br />

50-100 dB 124.0 dB<br />

SLM<br />

50-140 dB<br />

Maximum <strong>Level</strong> (L max )<br />

50-140 dB<br />

Fast (L max )<br />

1/16 second average<br />

Response (selectable)<br />

Slow or Fast<br />

Criterion Duration<br />

8 hours<br />

Exchange Rate (selectable)<br />

3, 4, 5 dB<br />

Threshold <strong>Level</strong> (selectable)<br />

None, 80, 85, 90 dB<br />

Criterion <strong>Level</strong><br />

80, 84, 85, 90 dB<br />

Weighting<br />

A or C<br />

Communications √ √<br />

(through CPI+)<br />

Software<br />

MKWin Windows-Based Software<br />

(with communications unit)<br />

Approvals MSHA 2G, UL Class I C, D / Class II E, F, G /<br />

Class III Hazardous Locations, FM, CSA<br />

Weight 9 oz. (250 grams) 10 oz. (285 grams)<br />

Dimensions ( L x W x H) 10 x 2.5 x 1.1 in (25.4 x 6.4 x 2.8 cm) 2.0 x 1.75 x 5.5 in (5.1 x 4.4 x 14.0 cm)<br />

Operating Temperature 0° to 122°F (-18 - 50°C) 32 - 122°F (0-50°C)<br />

Battery 9 VDC NEDA 1604 9 VDC NEDA 1604<br />

Catalog No. Model Description Price<br />

AM5320 MK1 Audio Dosimeter with standard Accessories $1,425.00<br />

AM5325 MK2 Audio Dosimeter with standard Accessories 1,755.00<br />

AM5335 MK3 Audio Dosimeter with standard Accessories 2,085.00<br />

AM5351 MK1-Kit Audio Dosimeter with standard Accessories and ACI calibrator 1,925.00<br />

AM5352 MK2-Kit Audio Dosimeter with standard Accessories and ACI calibrator 2,189.00<br />

AM5353 MK3-Kit Audio Dosimeter with standard Accessories and ACl calibrator 2,475.00<br />

Standard Accessories include; Dosimeter, belt-clip, microphone, Micboom, Mic Wind Screen, battery, carrying case, access tools and manual<br />

Windows-based software available for models MK2 and MK3 - see accessories below<br />

AM5310 ACI Acoustical Calibrator (only) with manual and battery 655.00<br />

AM5458 H5458 CPI+ with interface cables, manual and battery 963.00<br />

(required for printing or downloading from MK2 and MK3)<br />

AM5590 H5590 CPI+ with interface cables, MK WIN Software, manual and battery 1,073.00<br />

(required for printing or downloading from MK2 and MK3)<br />

Accessories<br />

AM92011 E92-011 MK WIN Software 375.00<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

S<br />

<strong>Sound</strong> <strong>Level</strong><br />

Davis Inotek Instruments<br />

www.davis.com<br />

1157


Noise Dosimeter/Profiler<br />

NIST it<br />

S<br />

<strong>Sound</strong> <strong>Level</strong><br />

1158<br />

DB-3060<br />

The DB-3060 delivers an economical solution to<br />

those users seeking a basic compliance tool.<br />

Attach a pendant microphone and you have a<br />

noise dosimeter. Substitute a boom microphone<br />

and you’ve converted your noise dosimeter to a<br />

power integrating sound level meter.<br />

Simple and Accurate — The Data You Need At<br />

Your Fingertips<br />

With the press of a button, the DB-3060 provides<br />

all of the basic measurements you need to<br />

comply:<br />

• Displays real-time sound level (SPL)<br />

• Captures and displays the maximum sound<br />

level detected (Lmax)<br />

• Captures and displays the peak sound level<br />

detected (Lpk)<br />

• Calculates and displays average sound level<br />

(Lavg or Leq)<br />

• Calculates and displays average sound level<br />

projected over 8 hours (TWA)<br />

• Calculates and displays % of allowable dose<br />

incurred (Dose)<br />

• Calculates and displays % of allowable dose<br />

expected over 8 hours (Projected Dose)<br />

• Tracks and displays total time over 115 db<br />

Easy Auto-Calibration<br />

Like all DB-3000 series monitors, the DB-3060<br />

field calibration is fast and easy. These monitors<br />

already know what sound level the acoustical calibrator<br />

outputs. Instantly initiate calibration from<br />

the DB-3060 keypad with the calibrator attached<br />

and let the noise monitor do the rest. Any adjustments<br />

that are necessary are automatically determined<br />

and made by the monitor.<br />

Davis Inotek Instruments<br />

DB Series Features<br />

• Noise Dosimeter<br />

• Integrating <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />

• Peak <strong>Sound</strong> <strong>Level</strong> <strong>Meter</strong><br />

• Recorded Statistics For Entire Test: Lav, Leq, Lmax, Lpeak, TWA, Dose,<br />

Projected Dose, Total Time Above Ceiling, User Selectable Criteria, Weighting<br />

(A or C), Response Rate (Fast or Slow), Exchange Rate (3, 4, 5 or 6 db)<br />

• Time History Profiler<br />

• Amplitude Distribution Profiler<br />

• Real Time Clock<br />

• For Each Time History Interval<br />

• Lav, Lmax<br />

• Lpeak<br />

• Time History Interval Length<br />

• Time History Ln’s<br />

• Amplitude Distribution Ln’s<br />

• Automatic Start/Stop Recording<br />

• Outputs Reports Directly to Printer<br />

• Transfers Data to PC<br />

DB-3080<br />

•Comprehensive Time History & Amplitude<br />

• Distribution Profiles<br />

• Print Multiple Reports<br />

• Automatically Starts & Stops Recording<br />

• Survey Mode With Auto-Stop<br />

• Advanced Software For Greater Productivity<br />

In today’s business climate, the value of effective<br />

and efficient tools to complete your work cannot<br />

be underrated. Metrosonics takes DB-3080<br />

users to another level of productivity with MS-<br />

3080W Metrosoft ® for Windows ® . This comprehensive<br />

data management and reporting system offers<br />

the benefits of electronically capturing, storing,<br />

analyzing, manipulating, and reporting noise<br />

survey results. MS-3080W takes the integrity, defensibility<br />

and value of your noise studies to unparalleled<br />

levels.<br />

Windows ® Compatibility<br />

MS-3080W works seamlessly with your current<br />

Windows ® printer drivers to provide you with high<br />

quality charts and reports. You will produce professional<br />

looking reports never before possible by<br />

copying and pasting information directly from<br />

Metrosoft ® to other Windows ® programs such as<br />

Word, Excel and Powerpoint.<br />

Powerful Charting Functions<br />

Time History and Amplitude Distribution reports<br />

available from the DB-3080 directly to a<br />

printer may also be generated by MS-3080W in report<br />

or chart format to ease the analysis and comparison<br />

of test results. Metrosoft’s ® tiling function<br />

enables you to perform on-screen, side-by-side<br />

comparisons of data. Zoom features allow enlarging<br />

plotted time history periods for more detailed<br />

examination of survey results at specific points in<br />

time. A scan line may be moved across time history<br />

charts to view the numeric data values<br />

represented by the chart graphics.<br />

Catalog No. Model Description Price<br />

QS139350 DB-3060-MK Noise Dosimeter Kit includes $1,390.00<br />

Dosimeter, wind screen, clip,<br />

CL-304 calibrator and storage case<br />

QS139351 DB-3080-MK Profiling Noise Dosimeter Kit 2,130.00<br />

includes dosimeter, wind screen,<br />

clip, CL-304 calibrator, printer cable,<br />

programming kit, software and<br />

storage case<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

www.davis.com


Personal Noise Dosimeters<br />

NIST it<br />

Measure Total <strong>Sound</strong> Exposure Over an 8-hour Period<br />

Basic Model 407354<br />

Records and displays % dose, dB<br />

sound level, exposure time, and peak<br />

events.<br />

Model 407355<br />

Has same functions as above but<br />

with advanced features: Storage of 5<br />

separate surveys, bi-directional RS-<br />

232 with Windows software, and a<br />

real time clock. Software permits user<br />

to customize setup and retrieve stored<br />

events (% dose, 8 hour % dose, Peak &<br />

RMS flags, exposure time, Peak time<br />

and Peak event duration) or analyze<br />

real time measurements. Includes data<br />

acquisition software, 9 pin to 25 pin<br />

adapter, and RS-232 cable.<br />

• Two low cost, lightweight, easy to use, personal<br />

noise dosimeters<br />

• Perform OSHA and IEC Noise accumulation<br />

surveys<br />

• Adjustable Criterion <strong>Level</strong>, Exchange Rate, and<br />

Threshold<br />

• Applications include Personal accumulated noise<br />

exposure measurement, Workplace noise<br />

assessment, OSHA and other regulatory agency<br />

compliances<br />

• Optional 94/114dB calibrator to perform “before”<br />

and “after” calibration checks per ANSI standards<br />

• Both dosimeters include belt clip and clip-on<br />

microphone, 4 x AAA batteries, mini screwdriver<br />

and carrying case. Model 407355 also includes<br />

software and cables<br />

SPECIFICATIONS<br />

(407354 & 407355)<br />

Standards<br />

Meets ANSI S1.25(1991) Type 2, ISO<br />

1999, BS 402 (1983)<br />

Range/Resolution<br />

70 - 140 dBA / 0.1dB<br />

Digital Display LCD 0.01-9999%<br />

Criterion <strong>Level</strong><br />

80, 84, 85, or 90dB<br />

Exchange Rate<br />

3, 4, 5 or 6 dB<br />

Threshold <strong>Level</strong><br />

70-90 (1db steps)<br />

Frequency weighting A<br />

Response Rate<br />

Fast or Slow<br />

High <strong>Level</strong> Detector/Peak Flag 115dB / 140dB<br />

Dimensions / Weight 4.2 x 2.5 x 1.3" (106 x 64 x 34mm) 8oz.<br />

(227g) incl.batteries<br />

Microphone<br />

1<br />

⁄2 inch electret condenser with 31" cable<br />

407354 407355<br />

Battery Life 38 hrs 34 hrs<br />

Event Storage 1 survey 5 surveys<br />

RS232 Interface no yes<br />

Real time clock no yes<br />

407355 Includes PC Windows software to maintain<br />

records and statistically analyze acquired data<br />

Catalog No. Model Description Price<br />

EH407354 407354 Noise Dosimeter $459.00<br />

EH407355 407355 Noise Dosimeter with RS-232 599.00<br />

Interface<br />

EH407769 407766 94/114dB <strong>Sound</strong> <strong>Level</strong> Calibrator 399.00<br />

EH407764 407764-EXT 15' Microphone extension cable 99.00<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

S<br />

<strong>Sound</strong> <strong>Level</strong><br />

Davis Inotek Instruments<br />

www.davis.com<br />

1159


<strong>Sound</strong>/Light/Voltage/ Event Recorder<br />

NIST it<br />

The CR87E Event Recorder with remote<br />

sensor employs advanced microcontroller design<br />

that enables this versatile instrument to<br />

accurately measure and record voltage, light<br />

and sound. LED display can read length of<br />

event, time between events or total number of<br />

events. Selector switches located on the face<br />

panel allow for the recording of 3 different<br />

event modes at 4 different recording speeds.<br />

S<br />

<strong>Sound</strong> <strong>Level</strong><br />

1160<br />

SPECIFICATIONS<br />

KEV Range<br />

24 VAC to 270 VAC (50/60Hz.)<br />

24 VDC to 180 VDC<br />

KEL Range<br />

Illumination threshold range<br />

18 Lux to 1900 Lux +/- 20%<br />

KES Range<br />

<strong>Sound</strong> threshold range<br />

40 dB to 114 dB @ 1Khz +/- 20%<br />

Ambient Operating Temperature +32°F to + 140°F (0°C to + 60°C)<br />

Ambient Operating Relative Humidity 96% maximum<br />

Chart Speed Selectable<br />

6 hours, 24 hours, 7 days, 31 days<br />

Chart Rotation Mode<br />

Selectable — single turn or<br />

continuous<br />

Chart Speed Accuracy +/- 1%<br />

Chart Diameter<br />

6 inches<br />

Display<br />

3 digit 0.5" LED to display event<br />

interval in minutes, length of the<br />

event in minutes, and/or total<br />

number of events<br />

Display Range<br />

0 - 999 minutes or event counts<br />

Event Probes<br />

KEV — AC/DC Voltage detecting<br />

with two wire clip leads<br />

KEL — A sensitive photocell<br />

KES — A sensitive audio transducer<br />

Primary Power Supply<br />

120 VAC, 50/60 Hz. (220-240 VAC,<br />

50/60 Hz. optional - CR87E220)<br />

Alternative Power<br />

12 Volt vehicle operation with<br />

optional adapter<br />

Battery Backup<br />

8 AA Alkaline batteries (not included)<br />

Battery Life<br />

48 hours continuous use<br />

Recording Pen<br />

Ink Type<br />

Case Size 9 1 ⁄4" x 7 1 ⁄4" x 2 3 ⁄4"<br />

Weight<br />

4 lbs., 7 oz.<br />

Davis Inotek Instruments<br />

• Advanced microcontroller design<br />

• Large LED digital display shows event interval in minutes and/or total<br />

number of events<br />

• Front panel selectable — All controls are located on front panel for<br />

fast and easy setup<br />

• 3 recording modes — 4 recording speeds<br />

• Complete with probes for voltage, light and sound<br />

• Single or continuous chart rotation<br />

• Standard adapter for 120 VAC operation (220 VAC optional)<br />

• Battery backup assures normal operation during power interruptions<br />

• 12 Volt operation — Allows use in vehicular or marine operations<br />

• Furnished complete with 2 cartridge pens & 60 (6” diameter) assorted<br />

charts<br />

• Convenient fold down carrying handle<br />

• Snap-on extra support legs<br />

• Free standing or wall mounted<br />

• Durable polycarbonate case<br />

• Weather proof NEMA type 4X (CSA type 4) case optional<br />

Catalog No. Model Description Price<br />

CR870 CR87E Event Recorder, 110-120 VAC, 50/60 Hz $289.00<br />

NISTSD4 — NIST Traceable Certificate with Data 285.00<br />

www.davis.com