Table 1. Operat<strong>in</strong>g Conditions for Trial Tests <strong>of</strong> Technos Clean<strong>in</strong>g Balls<br />

Test location<br />

M<strong>in</strong>imum<br />

Duration<br />

TBT<br />

Conc. Ratio<br />

(BR)<br />

Type <strong>of</strong><br />

Antiscalant<br />

Dose Rate <strong>of</strong><br />

Antiscalant<br />

Sponge Balls Ball<br />

Clean<strong>in</strong>g<br />

Frequency<br />

No. <strong>of</strong><br />

Balls/Charge<br />

Test #1 :<br />

3 Weeks<br />

110 o C 1.4 DSB (M) 2 ppm Technos 6 cycles/<br />

5<br />

RDC MSF Pilot<br />

Plant<br />

(Nov. 2 to<br />

Nov. 23, 1998)<br />

8 hours<br />

Test #2 :<br />

4 Weeks<br />

107 ∼1.4 DSB (M) 3 ppm Technos 6 cycles/<br />

1600<br />

Jeddah III plant,<br />

(Unit 9)<br />

(Feb.22 to<br />

Mar. 23, 1999)<br />

8 hours<br />

Test #3:<br />

6 Weeks<br />

98 1.4 Belgard<br />

1 ppm Technos 8 cycles/<br />

500<br />

Al-Jubail II Plant,<br />

(Unit 16)<br />

(Sept.1 to<br />

Oct.14, 2001)<br />

EV 2030<br />

8 hours<br />

13