<strong>Server</strong> <strong>Management</strong> <strong>Command</strong> <strong>Line</strong> <strong>Protocol</strong> (SM CLP) <strong>Specification</strong><br />
1399<br />
1400<br />
1401<br />
1402<br />
1403<br />
1404<br />
1405<br />
1406<br />
1407<br />
The Probable Cause and Probable Cause Description properties identify the probable cause of an<br />
execution error. Any errors generated by the Managed Element itself are characterized in the Probable<br />
Cause property, described in 219HTable 11. If an implementation includes the probcause keyword in a<br />
<strong>Command</strong> Response, the implementation shall assign the keyword one of the values from 220HTable 11. If an<br />
implementation includes the probcause_desc keyword in a <strong>Command</strong> Response, the implementation<br />
shall assign the probcause_desc keyword the value from 221HTable 11 that corresponds to the value<br />
assigned to the probcause keyword. The values for probcause and probcause_desc correspond to<br />
the ValueMap and Values for the ProbableCause property of CIM_Error.<br />
Table 11 – Probable Cause Values and Descriptions<br />
probcause probcause_desc<br />
0 Unknown<br />
1 Other<br />
2 Adapter/Card Error<br />
3 Application Subsystem Failure<br />
4 Bandwidth Reduced<br />
5 Connection Establishment Error<br />
6 Communications <strong>Protocol</strong> Error<br />
7 Communications Subsystem Failure<br />
8 Configuration/Customization Error<br />
9 Congestion<br />
10 Corrupt Data<br />
11 CPU Cycles Limit Exceeded<br />
12 Dataset/Modem Error<br />
13 Degraded Signal<br />
14 DTE-DCE Interface Error<br />
15 Enclosure Door Open<br />
16 Equipment Malfunction<br />
17 Excessive Vibration<br />
18 File Format Error<br />
19 Fire Detected<br />
20 Flood Detected<br />
21 Framing Error<br />
22 HVAC Problem<br />
23 Humidity Unacceptable<br />
24 I/O Device Error<br />
25 Input Device Error<br />
26 LAN Error<br />
27 Non-Toxic Leak Detected<br />
28 Local Node Transmission Error<br />
29 Loss of Frame<br />
30 Loss of Signal<br />
31 Material Supply Exhausted<br />
32 Multiplexer Problem<br />
33 Out of Memory<br />