Fender Systems - Trelleborg
Fender Systems - Trelleborg
Fender Systems - Trelleborg
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Unit Elements<br />
Dimensions<br />
Element H A B* C* D F J M W K E Anchors Weight<br />
UE250 250 109 114 71 20–27 152 33 25–35 218 50 300 M20 38<br />
UE300 300 130 138 84 23–32 184 38 30–40 260 50 300 M24 54<br />
UE400 400 165 187 102 25–35 248 41 30–40 330 250 500 M24 89<br />
UE500 500 195 229 119 28–37 306 42 40–52 390 250 500 M30 135<br />
UE550 550 210 252 126 32–38 336 42 40–52 420 250 500 M30 153<br />
UE600 600 225 275 133 35–45 366 42 40–52 450 250 500 M30 179<br />
UE700 700 270 321 163 35–45 428 56 50–65 540 250 500 M36 247<br />
UE750 750 285 344 170 38–45 458 56 50–65 570 250 500 M36 298<br />
UE800 800 300 366 178 38–45 488 56 50–65 600 250 500 M36 338<br />
UE900 900 335 412 198 42–50 550 60 57–80 670 250 500 M42 410<br />
UE1000 1000 365 458 212 46–58 610 60 57–80 730 250 500 M42 509<br />
UE1200 1200 435 557 252 46–60 748 61 65–90 870 250 500 M48 717<br />
UE1400 1400 495 642 281 50–65 856 67 65–90 990 250 500 M48 948<br />
UE1600 1600 565 733 321 50–65 978 76 75–100 1130 250 500 M56 1236<br />
* Asymmetrical bolting version only [Units: mm, kg/m]<br />
Unit Elements are high-performance modular rubber<br />
fenders. Elements are versatile and can be combined in<br />
unlimited combinations of length and direction.<br />
Asymmetrical bolting<br />
The simplest Unit Element system is the UE-V fender, with<br />
pairs of legs and a UHMW-PE non-marking shield. For<br />
heavy duty applications Unit Elements are combined with a<br />
steel panel (frame) which can cope with belting, bow flares,<br />
low hull pressures and high tides.<br />
Symmetrical bolting<br />
Element lengths<br />
600 750 900 1000 1200 1400 1500 1800 2000 Max<br />
UE250 2800<br />
UE300 2000<br />
UE400 2000<br />
UE 500–UE 550 1500<br />
UE 600–UE 800 2000<br />
UE 900–UE 1200 1500<br />
UE1400 2000<br />
UE1600 2000<br />
preferred lengths<br />
typical non-standard lengths<br />
[Units: mm]<br />
For elements with L/H < 1.0 or non-standard<br />
lengths, please ask for advice.<br />
RPD is reported at:<br />
– 1 mm/sec constant test speed<br />
– 23ºC ± 5ºC temperature<br />
– 0º compression angle<br />
Performance to meet local specified<br />
conditions is typically adjusted for<br />
velocity, angle and temperature.<br />
Please refer to Design Manual for more<br />
information on Velocity, Temperature<br />
and Angle Correction factors.<br />
Standard manufacturing and performance tolerances apply. Refer to Design and Testing Manual. M1100-S01-V1-3-EN © <strong>Trelleborg</strong> AB, 2013<br />
23