<strong>Australian</strong> <strong>Building</strong> <strong>Codes</strong> <strong>Board</strong> Page 5<br />

PART F1<br />

ON-SITE WASTEWATER MANAGEMENT<br />

SYSTEMS<br />

Deemed-to-Satisfy Provisions<br />

F1.1 Deemed-to-Satisfy Provisions<br />

Performance Requirement FP1.1 – FP1.5 is satisfied by complying with F1.2 as<br />

appropriate.<br />

F1.2 Deemed-to-Satisfy ProvisionsGeneral requirements<br />

(a)<br />

(b)<br />

(c)<br />

The size determination, design and installation of septic tanks must be in<br />

accordance with AS/NZS 1546.1.<br />

The size determination, design and installation of waterless composting toilets must<br />

be in accordance with AS/NZS 1546.2.<br />

The size determination, design and installation of aerated wastewater treatment<br />

systems must be in accordance with AS/NZS 1546.3.<br />

(d) The design, construction, installation, replacement, repair, alteration and<br />

maintenance of all sanitary plumbing and drainage systems must be in accordance<br />

with AS/NZS 3500.2 or Section 4 of AS/NZS 3500.5 as appropriate.<br />

(e)<br />

(f)<br />

The size determination, design, construction, installation, replacement, repair,<br />

alteration and maintenance of domestic land application systems must be in<br />

accordance with AS/NZS 1547.<br />

The management of domestic on-site wastewater management systems and<br />

domestic land application systems must be in accordance with AS/NZS 1547.<br />

PUBLIC COMMENT DRAFT<br />

NCC2014 Volume Three F1.2