Off Grid Systeme EFOY Pro Serie â 2. Generation EFOY ... - udomi
Off Grid Systeme EFOY Pro Serie â 2. Generation EFOY ... - udomi
Off Grid Systeme EFOY Pro Serie â 2. Generation EFOY ... - udomi
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>udomi</strong> GmbH Hochfeldstraße 8 D-74632 Neuenstein Deutschland<br />
Telefon: +49-7942-9420891 Telefax: +49-7942-9420898 email: sales@<strong>udomi</strong>.de www.<strong>udomi</strong>.de<br />
<strong>Off</strong> <strong>Grid</strong> Systems<br />
Duocartswitch for <strong>EFOY</strong> <strong>Pro</strong><br />
<strong>Off</strong>ers increased autonomy and completely<br />
emptied Methanol cartridges<br />
Functional description:<br />
With the Duocartswitch 2 Methanol cartridges can<br />
be connected to a single <strong>EFOY</strong> <strong>Pro</strong> fuel cell<br />
system.<br />
Advantages:<br />
• Increased autonomy (longer service interval<br />
before Methanol cartridges have to be<br />
replaced)<br />
• Cartridges get completely emptied<br />
• When used with the GSM-2 modem the user<br />
will be informed via SMS or Email when DCS1<br />
switches from a new Methanol cartridge.<br />
• The Duocartswitch measures how many liters<br />
of Methanol has been pumped out of the<br />
Methanol cartridge. This information is also<br />
available via the GSM-2 webportal or the<br />
RS232 interface of <strong>EFOY</strong> <strong>Pro</strong>.<br />
Duocartswitch<br />
DUOCARTSWITCH Command:<br />
SFC<br />
battery voltage 1<strong>2.</strong>73V<br />
output current 4.55A<br />
operation time (charge mode) 1541.0h<br />
operating state: auto on<br />
operating mode: auto<br />
cumulative output energy 128179.7Wh<br />
no error<br />
cartridge level above sensor or no sensor<br />
(cartridge 1 consumed 1.79l)<br />
SFC><br />
Technical specifications<br />
Dimensions<br />
Weight<br />
Ambient temperature<br />
Supply voltage<br />
<strong>EFOY</strong> <strong>Pro</strong> Firmware<br />
Methanol cartridges<br />
Trigger signal<br />
<strong>Pro</strong>duct<br />
Duocartswitch<br />
Application example<br />
174x119x96mm<br />
0,7kg<br />
-20°C bis +45°C<br />
12/24VDC<br />
Version 9.17 or higher<br />
M5, M10, M28 (with M28<br />
adapter)<br />
GPO Pin 1 EFOR-PRO<br />
Part#<br />
DCS1