General<br />
With the increasing demand for power systems in<br />
the telecommunication sector, and the need for<br />
more efficient use of operating and maintenance<br />
staff, Benning have produced a range of system<br />
monitoring. The Benning MCU 500, MCU 1000 and<br />
MCU 2000+ offer the user a solution depending<br />
on the customer requirements.<br />
BLT 150 and BLT 400 power systems are fitted<br />
with MCU 500 (Optional MCU 1000) monitoring<br />
system.<br />
By means of local indication (13 off LED´s) and<br />
numerical display, the system status can be<br />
quickly assessed.<br />
The MCU 1000 additionally offers direct communication,<br />
via a RS 485 interface, with the rectifier<br />
modules.<br />
As an optional extra the MCU 1000 may be fitted<br />
with a relay box having 8 volt free contact.<br />
Remote Monitoring System MCU 500, 1000 und 2000+<br />
Float<br />
Boost<br />
Battery test<br />
Battery test negative<br />
Rectifier failure<br />
Mains failure<br />
Fault U < 2,1 V/C<br />
Battery disch. U < 1,9 V/C<br />
LVD tripped<br />
Battery fuse tripped<br />
Load fuse tripped<br />
Battery fault<br />
(reserve)<br />
LED test/reset<br />
MCU 500<br />
DC-Power-Supply<br />
Contacts<br />
(1)<br />
The BLT 2500/5000 has the MCU 2000+ monitoring<br />
fitted as standard.<br />
Both MCU 1000 and MCU 2000+ monitoring<br />
systems have the facility to control and monitor<br />
the power system via the public telephone<br />
network.<br />
As an option, the MCU 1000 and MCU 2000+ signals<br />
can be transmitted via modem to a central<br />
control station.<br />
Float<br />
Boost<br />
Battery test<br />
Battery test negative<br />
Rectifier failure<br />
Mains failure<br />
Fault U < 2,1 V/C<br />
Battery disch. U < 1,9 V/C<br />
LVD tripped<br />
Battery fuse tripped<br />
Load fuse tripped<br />
Battery fault<br />
(reserve)<br />
LED test/reset<br />
DC-Power-Supply<br />
Contacts<br />
(1)<br />
RS 485<br />
(2)<br />
Using a PC and dedicated monitoring software,<br />
information can be sent and received by the<br />
customer based in the control station.<br />
MCU 1000<br />
Rectifier with (2)<br />
or without (1)<br />
interface<br />
The MCU 2000+ provides a large range of supervisory<br />
functions, and enables easy monitoring<br />
and controlling of the power supply system.<br />
Airport München, Benning - Power to Communikation<br />
Communication with the rectifiers is via an RS<br />
485 interface. Options include 8 additional volt<br />
free alarm contacts, 24 external digital inputs and<br />
15 measurement channels.<br />
Float<br />
Boost<br />
Battery test<br />
Battery test negative<br />
Rectifier failure<br />
Mains failure<br />
Fault U < 2,1 V/C<br />
Battery disch. U < 1,9 V/C<br />
LVD tripped<br />
Battery fuse tripped<br />
Load fuse tripped<br />
Battery fault<br />
(reserve)<br />
LED test/reset<br />
DC-Power-Supply<br />
RS 485<br />
(2)<br />
MCU 2000 +