The <strong>Dolomite</strong> Centre Ltd<br />

Mitos P-Pump Accessories<br />

product <strong>datasheet</strong><br />

page<br />

Flow Resistors 3<br />

Flow Resistor Selection 6<br />

Flow Resistor Kit 7<br />

Mitos P Pump Vessel Holder Kit 9<br />

Standard Vessel Compatibility Chart 11<br />

Mitos P Pump Starter Kit 13<br />

Pneumatic Connector Kit 14<br />

Mitos P Pump 3-way Chamber Kit 15<br />

Mitos P Pump 3-way Vessel Holder Kit 16<br />

Mitos P Pump Remote Chamber 400 17<br />

Mitos P-Pump Remote Chamber 30 18<br />

Mitos P-Pump Remote Chamber with<br />

3-way Accessories<br />

19<br />

Fluid Tube (1/16”) to Pneumatic Tube (6mm)<br />

Adaptor<br />

20<br />

Dip Tube Fitting 20<br />

USB to RS232 Adaptor Cable<br />

21<br />

MAR-000029 1.5 Page 1 of 22<br />

(Part No. 3200197)


The <strong>Dolomite</strong> Centre Ltd<br />

Part name<br />

Part number<br />

Flow Resistors 3200265-3200271<br />

Flow Resistor Kit 3200272<br />

Mitos P-Pump Vessel Holder Kit 3200017<br />

Mitos P-Pump Starter Kit 3200033<br />

Pneumatic Connector Kit 3200034<br />

Mitos P-Pump 3-way Chamber Lid 3200044<br />

Mitos P-Pump 3-way Vessel Holder Kit 3200045<br />

Mitos P-Pump Remote Chamber 400 3200043<br />

Mitos P-Pump Remote Chamber 30 3200178<br />

Mitos P-Pump Remote Chamber with 3-way Accessories 3200206<br />

Dip Tube Fitting 3200143<br />

Fluid Tube (1/16”) to Pneumatic Tube (6mm) Adaptor 3200301<br />

RS232 Serial Extension Cable 3200239<br />

RS232 to USB Adaptor Module 3200197<br />

MAR-000029 1.5 Page 2 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Flow Resistors (Part No. 3200265-3200271)<br />

Flow Resistors are high tolerance lengths of PEEK covered fused silica tubing that<br />

provide a known flow rate at a selected pressure. They can be used to insert additional<br />

flow resistance into a system and are designed for use with the Mitos P-Pump range.<br />

A Flow Resistor enables very low flow rates to be achieved when connecting to a Mitos<br />

P-Pump to systems of low fluidic resistance. For applications such as droplet generation,<br />

a Flow Resistor can be used to prevent flow rate instability due to the varying back<br />

pressure generated by using immiscible fluids of different viscosities. <strong>Dolomite</strong> offers a<br />

range of Flow Resistors to optimise your microfluidic system.<br />

3200267 - Flow Resistor F1<br />

system<br />

Flow resistor connected between a Mitos P-Pump and system<br />

MAR-000029 1.5 Page 3 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Benefits<br />

Allows the flow rate range of the Mitos P-Pump to be maximized<br />

Enables the user to operate at very low flow rates with the Mitos P-Pump<br />

Enables the use of very low viscosity liquids (e.g. gases) with the Mitos P-Pump<br />

Prevents flow rate instability when using fluids of different viscosities<br />

Two Flow Resistors can be used to provide equal flow splitting into two channels<br />

Quick and easy to connect using included fittings<br />

Excellent chemical compatibility<br />

Specifications<br />

Specification 3200265<br />

F0.1<br />

Approx. flow<br />

rate generated<br />

by water<br />

pumped at<br />

1bar pressure<br />

3200266<br />

F0.3<br />

3200267<br />

F1<br />

3200268<br />

F3<br />

3200269<br />

F10<br />

3200270<br />

F30<br />

3200271<br />

F100<br />

0.1µl/min 0.3µl/min 1µl/min 3µl/min 10µl/min 30µl/min 100µl/<br />

min<br />

Max flow rate 1 1µl/min 3µl/min 10µl/min 30µl/min 100µl/<br />

min<br />

300µl/<br />

min<br />

1000µl/<br />

min<br />

Min flow rate 2<br />

Internal<br />

diameter<br />

Internal<br />

diameter<br />

tolerance<br />

Outer diameter<br />

Wetted<br />

materials<br />

Sheath<br />

materials<br />

0.002µl/<br />

min<br />

0.006µl/<br />

min<br />

0.02µl/mi<br />

n<br />

0.06µl/mi<br />

n<br />

0.2µl/min 0.6µl/min 2µl/min<br />

25µm 50µm 75µm 100µm<br />

± 1µm ± 2µm ± 3µm ± 3µm<br />

1/16” (1.59mm)<br />

Fused silica<br />

Polyimide (inner sheath)<br />

PEEK (outer sheath)<br />

1) Maximum flow rate is the approximate flow rate produced with water when the Mitos P-<br />

Pump is set to 10bar and there is little or no fluidic resistance downstream of the flow<br />

restrictor.<br />

2) Minimum flow rate is the approximate flow rate produced with water when the Mitos P-<br />

Pump is set to 20mbar and there is little or no fluidic resistance downstream of the flow<br />

restrictor.<br />

MAR-000029 1.5 Page 4 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Flow accessories<br />

The Flow Resistors are supplied with the following flow accessories:<br />

2 x Compact Head Fittings (ETFE) with 1/4 - 28” thread for connection to 1/16”<br />

OD pipe, can be used with the Flangeless Ferules.<br />

2 x Flangeless Ferules (ETFE) for connection to 1/16” OD pipe. To be used with<br />

the Compact Head Fittings.<br />

2 x Straight Female Couplings (Polypropylene) with female to female 1/4 - 28”<br />

threads. The couplings are used for making connection between Compact Head<br />

Fittings.<br />

1 x Ferule (PCTFE) with Integrated Filter (stainless steel, 2 µm pore size). To be<br />

used with 1/16” OD pipe.<br />

Each Flow Resistor is supplied with these flow accessories to enable the Flow Resistor to<br />

be connected in-line. The included filter can be used to prevent blockage of the small<br />

internal diameter of the flow resistor.<br />

Flow resistors can also be directly connected to a microfluidic chip using the Multiflux®<br />

Linear Connectors.<br />

Each Flow Resistor is supplied with the above flow accessories<br />

to enable the Flow Resistor to be connected in-line.<br />

MAR-000029 1.5 Page 5 of 22


Dynamic viscosity of selected fluid (cP)<br />

The <strong>Dolomite</strong> Centre Ltd<br />

Flow Resistor Selection<br />

The Flow Resistor should be selected based on the desired flow rate and the viscosity of<br />

the selected fluid using the table below. This assumes that the flow resistance of the<br />

system is low in comparison with the Flow Resistor.<br />

0.1<br />

e.g. propane<br />

gas<br />

at 20ºC<br />

0.3<br />

e.g. acetone<br />

at 20 ºC<br />

0.1<br />

Flow rate<br />

range<br />

0.002 – 1<br />

Desired flow rate at 1bar pressure (µl/min)<br />

0.3<br />

Flow rate<br />

range<br />

0.006 – 3<br />

1<br />

Flow rate<br />

range<br />

0.02 – 10<br />

3<br />

Flow rate<br />

range<br />

0.06 – 30<br />

10<br />

Flow rate<br />

range<br />

0.2 – 100<br />

30<br />

Flow rate<br />

range<br />

0.6 – 300<br />

100<br />

Flow rate<br />

range<br />

2 – 1000<br />

- - F0.1 F0.3 F1 F3 F10<br />

- F0.1 F0.3 F1 F3 F10 F30<br />

1<br />

e.g. water<br />

at 20ºC<br />

3<br />

blood<br />

at 37ºC<br />

10<br />

25% wt CaCl<br />

sol.<br />

at 20ºC<br />

30<br />

vegetable oil<br />

at 40ºC<br />

100<br />

light machine<br />

oil<br />

at 20ºC<br />

F0.1 F0.3 F1 F3 F10 F30 F100<br />

F0.3 F1 F3 F10 F30 F100<br />

F1 F3 F10 F30 F100<br />

F3 F10 F30 F100<br />

F10 F30 F100<br />

Operate without<br />

flow resistors<br />

MAR-000029 1.5 Page 6 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Flow Resistor Kit (Part No. 3200272)<br />

Designed for the Mitos P-Pump range the Flow Resistor Kit can be used to insert<br />

additional flow resistance into a system. The Flow Resistors enable very low flow rates to<br />

be achieved when connecting to a Mitos P-Pump to systems of low fluidic resistance.<br />

For applications such as droplet generation, a Flow Resistor can be used to prevent flow<br />

rate instability due to the varying back pressure generated by using immiscible fluids of<br />

different viscosities.<br />

Flow Resistor Kit (Part No. 3200272)<br />

Benefits<br />

Allows the flow rate range of the Mitos P-Pump to be maximised<br />

Enables the user to operate at very low flow rates with the Mitos P-Pump<br />

Enables the use of very low viscosity liquids (e.g. gases) with the Mitos P-Pump<br />

Prevents flow rate instability when using fluids of different viscosities<br />

Quick and easy to connect using included fittings<br />

Excellent chemical compatibility<br />

MAR-000029 1.5 Page 7 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

The Flow Resistor Kit contains the following flow resistors:<br />

Item Description Qty<br />

1 Flow Resistor F1 Min flow rate: 0.02µl/min, Max flow rate: 10µl/min 1<br />

2 Flow Resistor F3 Min flow rate: 0.06µl/min, Max flow rate: 30µl/min 1<br />

3 Flow Resistor F10 Min flow rate: 0.2µl/min, Max flow rate: 100µl/min 1<br />

4 Flow Resistor F30 Min flow rate: 0.6µl/min, Max flow rate: 300µl/min 1<br />

5 Flow Resistor F100 Min flow rate: 2µl/min, Max flow rate: 1000µl/min 1<br />

Each flow resistor kit also contains 5 sets of flow accessories to enable the flow resistors<br />

to be connected in-line and the fluids to be filtered before entry into the flow resistor.<br />

Each Flow Resistor is supplied with the above flow accessories<br />

to enable the Flow Resistor to be connected in-line.<br />

MAR-000029 1.5 Page 8 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Mitos P-Pump Vessel Holder Kit (Part No. 3200017)<br />

The Mitos P-Pump Vessel Holders Kit contains 4 vessel holders to enable the Mitos<br />

P-Pump range to be used with a wide range of standard and non-standard fluid vessels.<br />

These include centrifuge tubes, auto sampler vials, scintillation vials, microreaction vials<br />

and other general purpose vials. The Vessel Holders can be easily positioned inside the<br />

pressure chamber and are quick to change.<br />

Left: Mitos P-Pump<br />

with vessel holder 2<br />

Right: Mitos P-Pump<br />

with vessel holder 4<br />

Vessel Holder 1 Vessel Holder 2 Vessel Holder 3 Vessel Holder 4<br />

MAR-000029 1.5 Page 9 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Benefits<br />

Accommodate a wide range of standard and non-standard fluid vessels<br />

Ensures the Mitos P-Pump can be used with preferred vessel<br />

Minimize sample waste by pumping directly from your container<br />

Enable use of micro vials for low sample volumes<br />

Specification<br />

Vessel<br />

Holder 1<br />

Vessel<br />

Holder 2<br />

Vessel<br />

Holder 3<br />

Vessel<br />

Holder 4<br />

1 Hole diameter D1 (mm) 8 11 16.5 11<br />

2 Height H1 (mm) 25 35 40 15<br />

3 Base diameter D2 (mm) 15 20 27 27<br />

4 Height H2 (mm) 5 5 N/A N/A<br />

5 Material Stainless Steel<br />

MAR-000029 1.5 Page 10 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Standard Vessel Compatibility Chart<br />

The compatibility chart contains some examples of commonly used vessels, which require<br />

a vessel holder for use with the Mitos P-Pump range.<br />

Standard Vessel Type<br />

Vessel Holder Required<br />

Abgene deep well cluster tube 0.3 ml 1<br />

Abgene deep well cluster tube 0.65 ml 1<br />

Abgene deep well cluster tube 1.2 ml 1<br />

Abgene flat cap tube 0.2 ml 1<br />

Autosampler vial 12 x 32 mm 1<br />

Autosampler vial 4 ml 1<br />

Chase culture tube 10 x 75 mm 4<br />

Chase culture tube 15 x 85 mm 3<br />

Chase scintillation vial 7 ml 2<br />

Chase scintillation vial 20 ml 3<br />

Chase scintillation vial 30 ml 3<br />

Chromacol universal storage vial 8ml 2<br />

MAR-000029 1.5 Page 11 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Eppendorf micro centrifuge tube 0.5 ml 1<br />

Eppendorf micro centrifuge tube 1.5 ml 4<br />

Eppendorf micro centrifuge tube 2.0 ml 4<br />

Micro reaction vessel 0.1 ml 2<br />

Micro reaction vessel 0.3 ml 2<br />

Micro reaction vessel 1 ml 2<br />

Micro reaction vessel 2 ml 2<br />

Micro reaction vessel 3 ml 3<br />

Micro reaction vessel 5 ml 3<br />

Nalgene cryogenic vial 1.2 ml 1<br />

Nalgene cryogenic vial 2 ml 1<br />

Nalgene cryogenic vial 5 ml 1<br />

Nalgene oak ridge centrifuge tube 10 ml 3<br />

Nalgene sample vial 5 ml 3<br />

Nalgene sample vial 12 ml 3<br />

Nalgene sample vial 18 ml 3<br />

Wheaton sample glass vial 2 ml 1<br />

Wheaton sample glass vial 4 ml 1<br />

Wheaton sample glass vial 6 ml 2<br />

Wheaton v vial 0.3 ml 1<br />

Wheaton v vial 1 ml 1<br />

Wheaton v vial 2 ml 2<br />

Wheaton v vial 3 ml 2<br />

MAR-000029 1.5 Page 12 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Mitos P-Pump Starter Kit (Part No. 3200033)<br />

The Mitos P-Pump Starter Kit contains a selection of vessels to enable sample liquids to<br />

be introduced into the range of Mitos P-Pumps. It also contains a selection of tubing and<br />

fittings to enable fluidic connection to be made between the P-Pump and your microfluidic<br />

system.<br />

Mitos P-Pump Starter Kit<br />

Benefits<br />

Enables the user to begin test work with the Mitos P-Pump immediately<br />

Contains a selection of vessels<br />

Contains a selection of tubing and fittings<br />

The Mitos P-Pump Starter Kit contains:<br />

Item Description Qty<br />

1 30ml glass vessel 30ml, Ø28 x H83mm, R3 screw neck with cap, class 1<br />

5<br />

hydrolytic extraction neutral borosilicate glass<br />

2 20ml high recovery 20ml, Ø28 x H67mm, 24-400 screw thread with cap, class 1 2<br />

glass vessel hydrolytic extraction neutral borosilicate glass, tapered<br />

reservoir for high sample recovery<br />

3 FEP tubing 0.25mm ID, 1/16” (1.6 mm) OD, 10m length 1<br />

4 FEP tubing with 0.25mm ID, 1/16” (1.6 mm) OD, 1m length, ¼”-28 threaded 1<br />

attached fitting fitting with PTFE gripper attached to one end<br />

5 ¼”-28 fitting ¼”-28 threaded nut and ferule for 1/16” (1.6mm) OD tubing 5<br />

6 ¼”-28 union ¼”-28 female to female threaded union 1<br />

7 Tube cutter Double bevelled cutting blade produces clean 90º cut on<br />

polymer tubing up to 2mm OD<br />

1<br />

MAR-000029 1.5 Page 13 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Pneumatic Connector Kit (Part No. 3200034)<br />

The Pneumatic Connector Kit contains a selection of fittings and tubing to enable<br />

connection of your compressed air or gas supply to the Mitos P-Pumps.<br />

Pneumatic Connector Kit<br />

Benefits<br />

Enables connection of most compressed air or gas supplies to the Mitos P-Pump<br />

Contains a selection of fittings and tubing<br />

The Pneumatic Connector Kit contains:<br />

Item Description Qty<br />

1 Pneumatic tubing 6mm OD, 4mm ID, 5m length, polyurethane 1<br />

2 Straight connector 6mm Push-in tube – tube connector for 6mm OD tube 1<br />

3 Reducer 6 – 4mm 6mm male to 4mm female push-in tube connector 1<br />

4 Reducer 8 – 6mm 8mm male to 6mm female push-in tube connector 1<br />

5 T connector 6mm 6mm push-in 3-way tube connector 3<br />

6 Adaptor 6mm to 1/4” 6mm push-in tube connector to 1/4” BSPT male thread 1<br />

BSPT<br />

7 Adaptor 6mm to 1/8” 6mm push-in tube connector to 1/8” BSPP female thread 1<br />

BSPP<br />

8 Adaptor 1/4” NPT to 1/4” 1/4” NPT male thread to 1/4” BSPP female thread 1<br />

BSPP<br />

9 Adaptor 1/4” to 1/8” BSPT 1/4" push-in tube connector to 1/8” BSPT male thread 1<br />

MAR-000029 1.5 Page 14 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Mitos P-Pump 3-way Chamber Lid (Part No. 3200044)<br />

The Mitos P-Pump 3-way Chamber Lid can be used to pump 3 liquids simultaneously<br />

from the Mitos P-Pump (Part No. 3200016). This provides a low cost method of delivering<br />

3 reagents to a microfluidic system with pulseless pressure pump technology. Also<br />

available, is a Mitos P-Pump 3-way Vessel Holder Kit (Part No. 3200045) to enable 3<br />

reagent vessels to be inserted into the chamber with ease.<br />

Mitos P-Pump 3-way Chamber Lid<br />

Mitos P-Pump with 3-way Chamber Lid and 3-way Vessel Holder<br />

Benefits<br />

Provides a low cost solution for 3-channel pumping with the Mitos P-Pump<br />

Push-and-rotate mechanism that is quick to open and close<br />

Safety features to ensure chamber is locked when pressurized<br />

Contains plugs to enable ports to be blocked when not required<br />

Specification<br />

Value<br />

1 Number of ports 3<br />

2 Chamber dimensions Ø30 x H 88mm<br />

3 Dip tube size 1/16” OD; 250µm ID<br />

4 Wetted materials User selected vessel and dip tube (e.g. glass<br />

and PTFE)<br />

5 Number of plugs included 10<br />

MAR-000029 1.5 Page 15 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Mitos P-Pump 3-way Vessel Holder Kit (Part No. 3200045)<br />

The Mitos P-Pump 3-way Vessel Holder Kit is designed to accommodate 3 micro tubes<br />

in the Mitos P-Pump (Part No. 3200016). Included in the kit are compatible micro tubes<br />

with 1.5 ml volume. When used in conjunction with the 3-way Chamber Lid (Part No.<br />

3200044), it provides a low cost method of delivering 3 reagents to a microfluidic system<br />

with pulseless pressure pump technology.<br />

Mitos P-Pump 3-way Vessel Holder<br />

1.5 ml micro tube<br />

Mitos P-Pump with 3-way Chamber<br />

Lid and 3-way Vessel Holder<br />

Benefits<br />

Improves ease of use when using the Mitos P-Pump for 3-channel pumping<br />

Enables P-Pump to be used with 3 micro tubes<br />

Quick to install and remove<br />

Locating feature to align micro tubes with outlet ports in chamber lid<br />

Specification<br />

Value<br />

1 Vessel holder hole diameter D1 (mm) 11<br />

2 Vessel holder height H1 (mm) 15<br />

3 Vessel holder base diameter D2 (mm) 29<br />

4 Vessel holder material Stainless Steel<br />

5 Number of micro tubes 20<br />

6 Micro tube volume (ml) 1.5<br />

7 Micro tube material Polypropylene<br />

MAR-000029 1.5 Page 16 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Mitos P-Pump Remote Chamber 400 (Part No. 3200043)<br />

The Mitos P-Pump Remote Chamber 400 is a 10bar stainless steel pressure chamber for<br />

use with the Mitos P-Pump (Part No. 3200016). It enables greater sample volumes up to<br />

400ml to be used, so that continuous pumping for longer periods of time is possible. With<br />

the precise pressure-driven pumping mechanism of the Mitos P-Pump, the flow from the<br />

chamber is highly stable and pulsefree. The remote chamber 400 is simple to connect<br />

and provides clear viewing of the sample liquid. For applications requiring temperature<br />

control and stirring, the remote chamber can be placed onto a hotplate/magnetic stirrer.<br />

3200043 - Mitos P-Pump<br />

Remote Chamber 400<br />

Mitos P-Pump (Part No. 3200016) with<br />

Remote Chamber 400<br />

Benefits<br />

Expands P-Pump capacity to liquid vessels up to 400ml<br />

Continuous pumping for long periods of time<br />

Option for heating and magnetic stirring<br />

Easy to view sample liquid levels<br />

Simple to connect to the P-Pump for precise pressure control<br />

250 ml DURAN vessel included<br />

Excellent chemical compatibility<br />

Specification<br />

Value<br />

1 Pressure range 0 – 10bar (0 – 145psi) gauge<br />

2 Temperature limit 50ºC<br />

2 Chamber dimensions Ø82 x H 140mm<br />

3 Sample volume up to 400ml (with 400ml tall form beaker)<br />

4 Dip tube size 1/16” OD; 250µm ID<br />

5 Product size Ø148 x H 200mm<br />

6 Product weight 5.5kg<br />

7 Chamber materials Stainless Steel, Glass, Viton, PEEK<br />

8 Wetted materials User selected vessel and dip tube (e.g. glass and PTFE)<br />

Note: Pressure control performance will be as indicated in the P-Pump specification except response and settling times will<br />

be slower due to the increased volume<br />

MAR-000029 1.5 Page 17 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Mitos P-Pump Remote Chamber 30 (Part No. 3200178)<br />

The Mitos P-Pump Remote Chamber 30 is a 0 – 10bar lockable glass pressure chamber<br />

for use with the Mitos P-Pump Remote (Part No. 3200176) and Mitos P-Pump Remote<br />

Basic (Part No. 3200177). It is easy to access and can accommodate samples from 100µl<br />

to 30ml.<br />

The Mitos P-Pump Remote Chamber 30 connects to a Mitos P-Pump Remote via a<br />

simple push-and-click action. For applications requiring temperature control and stirring,<br />

the remote chamber can be placed onto a hotplate, magnetic stirrer or placed in an<br />

incubator.<br />

Left: Mitos P-Pump Remote Chamber 30<br />

(Part No. 3200178)<br />

Below: Mitos P-Pump Remote Chamber<br />

30 (Part No. 3200178) connected to Mitos<br />

P-Pump Remote (Part No. 3200176)<br />

Benefits<br />

Sample volumes from 100µl to 30ml<br />

Option for heating and magnetic stirring<br />

Easy to view sample liquid levels<br />

Quick and easy fitting to connect to Mitos P-Pump Remote<br />

Excellent chemical compatibility<br />

MAR-000029 1.5 Page 18 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Mitos P-Pump Remote Chamber with 3-way Accessories (Part No. 3200206)<br />

The Mitos Remote Chamber with 3-way Accessories is the Mitos P-Pump Remote<br />

Chamber 30 (Part No. 3200178) with Mitos P-Pump 3-way Chamber Lid (Part No.<br />

3200044) and Mitos P-Pump 3-way Vessel Holder Kit (Part No. 3200045), it provides a<br />

low cost method of delivering 3 reagents to a microfluidic system with pulseless pressure<br />

pump technology.<br />

3200178 - Mitos P-Pump Remote<br />

Chamber 30<br />

3200044 - Mitos P-Pump Basic<br />

with 3-way Chamber Lid<br />

3200045 - 3-way Vessel Holder Kit<br />

Benefits<br />

Sample volumes from 100µl to 30ml<br />

Option for heating and magnetic stirring<br />

Easy to view sample liquid levels<br />

Quick and easy fitting to connect to Mitos P-Pump Remote<br />

Excellent chemical compatibility<br />

MAR-000029 1.5 Page 19 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

Dip Tube Fitting (Part No. 3200143)<br />

Designed for use with the Mitos P-Pump (Part No. 3200016), the Dip Tube Fitting allows<br />

users to easily connect a dip tube into a fluid vessel on the Mitos P-Pump. The fitting<br />

features an in-built strain relief and is compatible with 1/16 OD tubing and 1/4- 28 flat<br />

bottom ports.<br />

Dip Tube Fitting (Part No. 3200143)<br />

Fluid Tube (1/16”) to Pneumatic Tube (6mm) Adaptor (Part No. 3200301)<br />

The Fluid Tube (1/16”) to Pneumatic Tube (6mm) Adaptor is used to convert 6mm air<br />

lines to 1/16” fluid tube, which is the tubing size required for connection to all Mitos P-<br />

Pumps.<br />

Fluid Tube (1/16”) to Pneumatic Tube (6mm) Adaptor (Part No. 3200301)<br />

MAR-000029 1.5 Page 20 of 22


The <strong>Dolomite</strong> Centre Ltd<br />

USB to RS232 Adaptor Cable<br />

For PCs that do not support an RS232 serial interface, <strong>Dolomite</strong> offers a RS232 Serial<br />

Extension Cable (Part No. 3200239) and a RS232 to USB Adaptor Module (Part No.<br />

3200197) allowing users to connect their Mitos P-Pump Basic (Part No. 3200175) or<br />

Mitos P-Pump Remote Basic (Part No. 3200177) to a PC.<br />

Right: RS232 Serial Extension Cable (Part No. 3200239)<br />

Left: RS232 to USB Adaptor Module (Part No. 3200197)<br />

MAR-000029 1.5 Page 21 of 22