Transition Plan


Report #UCR P5496 <strong>PE</strong> Utilities Building<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim<br />

Solution<br />

Action<br />

Completion<br />

Date<br />

UCR P5496<br />

<strong>PE</strong> Utilities<br />

Building<br />

1-Doors: Men's<br />

Restroom at <strong>PE</strong> Utilities<br />

Building.<br />

5 lb. maximum pressure to operate exterior<br />

doors. Door hardware is operable with a single<br />

effort (lever type, panic bar or push pull type).<br />

Adjust door opening pressure /<br />

closing time unless accepted<br />

by DSA Fire / Life Safety.<br />

Consider issues connected<br />

with building pressure / climate<br />

control.Replace door hardware<br />

with compliant hardware.<br />

1 $784.01<br />

UCR P5496<br />

<strong>PE</strong> Utilities<br />

Building<br />

UCR P5496<br />

<strong>PE</strong> Utilities<br />

Building<br />

2-Clear Space at Doors:<br />

Men's Restroom at <strong>PE</strong><br />

Utilities Building.<br />

3-Identification Symbols,<br />

Restrooms: Men's<br />

Restroom at <strong>PE</strong> Utilities<br />

Building.<br />

Floor or landing is level and clear (2% max.<br />

slope). Minimum strike side clearance on PUSH<br />

side of door: 12" front approach with latch and<br />

closer.<br />

Signs are centered on door 60" from floor. Wall<br />

mounted signage: Symbol of accessibility is<br />

mounted on wall sign adjacent to latch side of<br />

door [ADAAG 703.6.1 & CBC 1117B.5.5 Item 4<br />

Pictograms shall have a field height of 6"<br />

ADAAG 703.6.1 Characters and Braille shall not<br />

be located in the pictogram field].<br />

Install level exterior door<br />

landing.<br />

Install wall-mounted sign at<br />

single entrance. Lower door<br />

signage.<br />

1 $980.25<br />

3 $428.77<br />

UCR P5496<br />

<strong>PE</strong> Utilities<br />

Building<br />

4-Multiple<br />

Accommodation Toilets:<br />

Men's Restroom at <strong>PE</strong><br />

Utilities Building.<br />

44" min. clear path provided throughout facility.<br />

The accessible stall door shall have an<br />

automatic closing device. 18" betwen centerline<br />

of water closet and side wall or partition<br />

[ADAAG 604.2 16" - 18" to centerline of water<br />

closet].. The toilet paper dispenser is located on<br />

the side wall below the grab bar and within 7" -<br />

9" of the front of the toilet seat as measured to<br />

the centerline of the dispenser.<br />

Requires<br />

engineering/architectural<br />

evaluation. Relocate water<br />

closet. Provide a closer at the<br />

stall door. Relocate the toilet<br />

paper dispenser away from the<br />

top of the grab bar.<br />

3 $9,798.43<br />

UCR P5496<br />

<strong>PE</strong> Utilities<br />

Building<br />

UCR P5496<br />

<strong>PE</strong> Utilities<br />

Building<br />

5-Toilet Grab Bars:<br />

Men's Restroom at <strong>PE</strong><br />

Utilities Building. [One<br />

continuous bar. See<br />

Sequence #4 for<br />

additional<br />

recommendations.]<br />

6-Lavatories: Men's<br />

Restroom at <strong>PE</strong> Utilities<br />

Building.<br />

The front of the side grab bar extends 52" from<br />

back wall in multiple accommodation restroom.<br />

Area directly above grab bars or proposed grab<br />

bars is free of protruding obstructions to a<br />

height of 18" (recessed items are allowed).<br />

30" x 48" min. clear space provided in front of<br />

lavatory that allows forward approach (doors<br />

may not encroach into this space). 27" high x 8"<br />

deep knee clearance under front lip.<br />

Relocate side grab bar.<br />

Relocate the seat cover<br />

dispenser away from the top of<br />

the grab bar.<br />

3 $612.51<br />

Raise existing lavatory. 3 $2,205.04<br />

6/1/2012 Page 1 of 3


Report #UCR P5496 <strong>PE</strong> Utilities Building<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim<br />

Solution<br />

Action<br />

Completion<br />

Date<br />

UCR P5496<br />

<strong>PE</strong> Utilities<br />

Building<br />

7-Urinals: Men's<br />

Restroom at <strong>PE</strong> Utilities<br />

Building.<br />

17" maximum urinal rim height above the<br />

finished floor. 14" minimum projection and 17"<br />

maximum projection from the wall.<br />

Replace with accessible urinal. 3 $3,185.07<br />

UCR P5496<br />

<strong>PE</strong> Utilities<br />

Building<br />

UCR P5496<br />

<strong>PE</strong> Utilities<br />

Building<br />

UCR P5496<br />

<strong>PE</strong> Utilities<br />

Building<br />

8-Accessories: Men's<br />

Restroom at <strong>PE</strong> Utilities<br />

Building.<br />

10-Water Fountains<br />

(Drinking): At <strong>PE</strong><br />

Utilities Building.<br />

11-Doors: Women's<br />

Restroom at <strong>PE</strong> Utilities<br />

Building.<br />

40" max. height to all other fixtures (i.e., soap<br />

dispensers, towels, toilet seat covers, auto<br />

dryers, sanitary napkins, waste recepatacles,<br />

etc.).<br />

32" minimum wide and 18" minimum deep<br />

alcove provided. 18" - 19" depth of fountain.<br />

Bubbler outlet is 36" maximum from floor.<br />

1/4" maximum vertical threshold or 1/2" beveled<br />

at 1:2. 5 lb. maximum pressure to operate<br />

exterior doors.<br />

Lower the paper towel<br />

dispenser. Lower the soap<br />

dispenser.<br />

Install new HI-LO drinking<br />

fountain. Install canedetectable<br />

barrier around<br />

fountain.<br />

Install level exterior door<br />

landing.Adjust door opening<br />

pressure / closing time unless<br />

accepted by DSA Fire / Life<br />

Safety. Consider issues<br />

connected with building<br />

pressure / climate control.<br />

3 $245.01<br />

2 $8,149.34 Defer.<br />

3 $1,286.50<br />

UCR P5496<br />

<strong>PE</strong> Utilities<br />

Building<br />

13-Identification<br />

Symbols, Restrooms:<br />

Women's Restroom at<br />

<strong>PE</strong> Utilities Building.<br />

Signs are centered on door 60" from floor. Wall<br />

mounted signage: Symbol of accessibility is<br />

mounted on wall sign adjacent to latch side of<br />

door [ADAAG 703.6.1 & CBC 1117B.5.5 Item 4<br />

Pictograms shall have a field height of 6"<br />

ADAAG 703.6.1 Characters and Braille shall not<br />

be located in the pictogram field].<br />

Install wall-mounted sign at<br />

single entrance. Lower door<br />

sign.<br />

3 $428.77<br />

6/1/2012 Page 2 of 3


Report #UCR P5496 <strong>PE</strong> Utilities Building<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim<br />

Solution<br />

Action<br />

Completion<br />

Date<br />

UCR P5496<br />

<strong>PE</strong> Utilities<br />

Building<br />

14-Multiple<br />

Accommodation Toilets:<br />

Women's Restroom at<br />

<strong>PE</strong> Utilities Building.<br />

44" min. clear path provided throughout facility.<br />

The accessible stall door shall have an<br />

automatic closing device. Door has loop or U-<br />

shaped handle immediately below latch on both<br />

inside and outside of door. The clear floor area<br />

on the push side of the door within the stall is<br />

the width of the door and a minimum 48" deep.<br />

If the compartment has an end opening outwardswinging<br />

door (facing the water closet), a<br />

minimum 60" wide x 48"deep clear floor space<br />

is provided in front of the water closet. 18"<br />

betwen centerline of water closet and side wall<br />

or partition [ADAAG 604.2 16" - 18" to centerline<br />

of water closet].. The toilet paper dispenser is<br />

located on the side wall below the grab bar and<br />

within 7" - 9" of the front of the toilet seat as<br />

measured to the centerline of the dispenser.<br />

Requires<br />

engineering/architectural<br />

evaluation. Install stall door<br />

hardware. Relocate water<br />

closet. Provide a closer at the<br />

stall door. Relocate the toilet<br />

paper dispenser away from the<br />

top of the grab bar.<br />

3 $10,165.94<br />

UCR P5496<br />

<strong>PE</strong> Utilities<br />

Building<br />

UCR P5496<br />

<strong>PE</strong> Utilities<br />

Building<br />

15-Toilet Grab Bars:<br />

Women's Restroom at<br />

<strong>PE</strong> Utilities Building.<br />

[Continuous grab bar.<br />

See Sequence #14 for<br />

additional<br />

recommendations.]<br />

17-Accessories:<br />

Women's Restroom at<br />

<strong>PE</strong> Utilities Building.<br />

The front of the side grab bar extends 52" from<br />

back wall in multiple accommodation restroom.<br />

Area directly above grab bars or proposed grab<br />

bars is free of protruding obstructions to a<br />

height of 18" (recessed items are allowed).<br />

40" max. height to all other fixtures (i.e., soap<br />

dispensers, towels, toilet seat covers, auto<br />

dryers, sanitary napkins, waste recepatacles,<br />

etc.). Coat hooks and shelving are located<br />

within appropriate reach ranges (48" max.<br />

height above floor surface is recommended).<br />

Install two grab bars. Relocate<br />

the seat cover dispenser away<br />

from the top of the grab bar.<br />

Relocate the toilet paper<br />

dispenser away from the top of<br />

the grab bar.<br />

Lower the soap dispenser.<br />

Lower the paper towel<br />

dispenser. Install accessible<br />

coat hook.<br />

3 $980.02<br />

3 $367.51<br />

Grand Total $39,617.17<br />

6/1/2012 Page 3 of 3


Cost Report


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

1. Doors - Men’s Restroom at <strong>PE</strong> Utilities Building.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Adjust door for opening pressure/closing times unless accepted 1 ea. $215.20 $215.20 $236.72 $266.31 $306.26 $306.26<br />

by DSA / Fire Life Safety.<br />

Replace door hardware with compliant hardware. 1 ea. $335.71 $335.71 $369.28 $415.44 $477.76 $477.76<br />

TOTAL EST: $784.02<br />

2. Clear Space at Doors - Men’s Restroom at <strong>PE</strong> Utilities Building.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install level exterior door landing. 40 s.f. $17.22 $688.80 $757.68 $852.39 $980.25 $980.25<br />

TOTAL EST: $980.25<br />

3. Identification Symbols, Restrooms - Men’s Restroom at <strong>PE</strong> Utilities Building.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install wall-mounted sign at single entrance. 1 ea. $129.12 $129.12 $142.03 $159.78 $183.75 $183.75<br />

Relocate existing signage. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $428.76<br />

4. Multiple Accommodation Toilets - Men’s Restroom at <strong>PE</strong> Utilities Building.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $5,000.00 $5,000.00 $5,500.00 $6,187.50 $7,115.62 $7,115.62<br />

Relocate water closet. 1 ea. $1,463.36 $1,463.36 $1,609.70 $1,810.91 $2,082.55 $2,082.55<br />

Provide a closer at the stall door. 1 ea. $335.71 $335.71 $369.28 $415.44 $477.76 $477.76<br />

Relocate the toilet paper dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

bars or proposed grab bars.<br />

TOTAL EST: $9,798.44<br />

Page 1 of 4


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

5. Toilet Grab Bars - Men’s Restroom at <strong>PE</strong> Utilities Building.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate grab bar. 2 ea. $172.16 $344.32 $378.75 $426.09 $490.00 $490.00<br />

Relocate the seat cover dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

bars or proposed grab bars.<br />

TOTAL EST: $612.51<br />

6. Lavatories - Men’s Restroom at <strong>PE</strong> Utilities Building.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Raise/Lower existing lavatory. 1 ea. $1,549.44 $1,549.44 $1,704.38 $1,917.43 $2,205.04 $2,205.04<br />

TOTAL EST: $2,205.04<br />

7. Urinals - Men’s Restroom at <strong>PE</strong> Utilities Building.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace/Install urinal. 1 ea. $2,238.08 $2,238.08 $2,461.89 $2,769.63 $3,185.07 $3,185.07<br />

TOTAL EST: $3,185.07<br />

8. Accessories - Men’s Restroom at <strong>PE</strong> Utilities Building.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate the paper towel dispenser / hand dryer. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

Relocate the soap dispenser. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

TOTAL EST: $245.02<br />

10. Water Fountains (Drinking) - At <strong>PE</strong> Utilities Building.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install new HI-LO drinking fountain. 1 ea. $4,900.00 $4,900.00 $5,390.00 $6,063.75 $6,973.31 $6,973.31<br />

Install cane-detectable barrier around fountain. 2 ea. $413.18 $826.36 $909.00 $1,022.62 $1,176.01 $1,176.01<br />

TOTAL EST: $8,149.32<br />

Page 2 of 4


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

11. Doors - Women’s Restroom at <strong>PE</strong> Utilities Building.<br />

Priority: 2<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install level exterior door landing. 40 s.f. $17.22 $688.80 $757.68 $852.39 $980.25 $980.25<br />

Adjust door for opening pressure/closing times unless accepted 1 ea. $215.20 $215.20 $236.72 $266.31 $306.26 $306.26<br />

by DSA / Fire Life Safety.<br />

TOTAL EST: $1,286.51<br />

13. Identification Symbols, Restrooms - Women’s Restroom at <strong>PE</strong> Utilities Building.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Install wall-mounted sign at single entrance. 1 ea. $129.12 $129.12 $142.03 $159.78 $183.75 $183.75<br />

Relocate existing signage. 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01<br />

TOTAL EST: $428.76<br />

14. Multiple Accommodation Toilets - Women’s Restroom at <strong>PE</strong> Utilities Building.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Requires engineering/architectural evaluation. 1 ea. $5,000.00 $5,000.00 $5,500.00 $6,187.50 $7,115.62 $7,115.62<br />

Replace/Install stall door hardware. 1 ea. $258.24 $258.24 $284.06 $319.57 $367.51 $367.51<br />

Relocate water closet. 1 ea. $1,463.36 $1,463.36 $1,609.70 $1,810.91 $2,082.55 $2,082.55<br />

Provide a closer at the stall door. 1 ea. $335.71 $335.71 $369.28 $415.44 $477.76 $477.76<br />

Relocate the toilet paper dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

bars or proposed grab bars.<br />

TOTAL EST: $10,165.95<br />

15. Toilet Grab Bars - Women’s Restroom at <strong>PE</strong> Utilities Building.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Replace/Install grab bar. 2 ea. $258.24 $516.48 $568.13 $639.15 $735.02 $735.02<br />

Relocate the seat cover dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

bars or proposed grab bars.<br />

Relocate the toilet paper dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

bars or proposed grab bars.<br />

TOTAL EST: $980.04<br />

Page 3 of 4


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue Qty Unit<br />

Sub<br />

Contractor<br />

Sub<br />

Total<br />

(10%)<br />

Concealed<br />

Conditions<br />

(12.5%)<br />

Security<br />

Conditions<br />

(15%)<br />

General<br />

Conditions<br />

Total<br />

17. Accessories - Women’s Restroom at <strong>PE</strong> Utilities Building.<br />

Priority: 3<br />

RECOMMENDATIONS AND RETROFIT COSTS:<br />

Relocate the soap dispenser. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

Relocate the paper towel dispenser / hand dryer. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

Install accessible coat hook. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51<br />

TOTAL EST: $367.53<br />

REPORT TOTALS: $27,838.13 $30,621.94 $34,449.68 $39,617.13 $39,617.13<br />

Page 4 of 4


Survey


Americans with Disabilities Act of 1990<br />

Site Assessment Report<br />

Report: UCR P5496 <strong>PE</strong><br />

Utilities Building<br />

900 University Avenue<br />

Riverside, CA 92521<br />

Inspection Date: 08/18/2009<br />

Prepared for:<br />

University of California at Riverside<br />

Prepared by:<br />

National Access Consultants, LLC<br />

2321 Abbot Kinney Blvd. Suite 200<br />

Venice, California 90291<br />

(805)497-6116


Contents<br />

1. Doors - Men’s Restroom at <strong>PE</strong> Utilities Building. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1<br />

2. Clear Space at Doors - Men’s Restroom at <strong>PE</strong> Utilities Building. . . . . . . . . . . . . . . . . . . . . 3<br />

3. Identification Symbols, Restrooms - Men’s Restroom at <strong>PE</strong> Utilities Building. . . . . . . . . . . . . 5<br />

4. Multiple Accommodation Toilets - Men’s Restroom at <strong>PE</strong> Utilities Building. . . . . . . . . . . . . . 6<br />

5. Toilet Grab Bars - Men’s Restroom at <strong>PE</strong> Utilities Building. . . . . . . . . . . . . . . . . . . . . . . 9<br />

6. Lavatories - Men’s Restroom at <strong>PE</strong> Utilities Building. . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

7. Urinals - Men’s Restroom at <strong>PE</strong> Utilities Building. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />

8. Accessories - Men’s Restroom at <strong>PE</strong> Utilities Building. . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />

9. Electrical Controls & Receptacles/Fire Alarm Boxes - Men’s Restroom at <strong>PE</strong> Utilities Building. . . 15<br />

10. Water Fountains (Drinking) - At <strong>PE</strong> Utilities Building. . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

11. Doors - Women’s Restroom at <strong>PE</strong> Utilities Building. . . . . . . . . . . . . . . . . . . . . . . . . . . . 19<br />

12. Clear Space at Doors - Women’s Restroom at <strong>PE</strong> Utilities Building. . . . . . . . . . . . . . . . . . . 21<br />

13. Identification Symbols, Restrooms - Women’s Restroom at <strong>PE</strong> Utilities Building. . . . . . . . . . . . 23<br />

14. Multiple Accommodation Toilets - Women’s Restroom at <strong>PE</strong> Utilities Building. . . . . . . . . . . . 24<br />

15. Toilet Grab Bars - Women’s Restroom at <strong>PE</strong> Utilities Building. . . . . . . . . . . . . . . . . . . . . . 27<br />

16. Lavatories - Women’s Restroom at <strong>PE</strong> Utilities Building. . . . . . . . . . . . . . . . . . . . . . . . . 29<br />

17. Accessories - Women’s Restroom at <strong>PE</strong> Utilities Building. . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

18. Electrical Controls & Receptacles/Fire Alarm Boxes - Women’s Restroom at <strong>PE</strong> Utilities Building. 32


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

1. Doors - Men’s Restroom at <strong>PE</strong> Utilities Building.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

32” minimum clear width of doorway.<br />

Hardware is 30” to 44” above floor.<br />

3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

5 lb. maximum pressure to operate exterior doors. (20 lbs.)<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Recommendation:<br />

Adjust door for opening pressure/closing times unless accepted by DSA / Fire Life Safety.<br />

Replace door hardware with compliant hardware.<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-1-1 (originally 1)<br />

1


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-1-2 (originally 2)<br />

2


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

2. Clear Space at Doors - Men’s Restroom at <strong>PE</strong> Utilities Building.<br />

Memo:<br />

Areas noted in compliance:<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PULL side of door: 24” exterior doors.<br />

Areas not meeting new construction standards:<br />

Floor or landing is level and clear (2% max. slope). (5.6%.)<br />

Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer. (9” (shrub).)<br />

Recommendation:<br />

Install level exterior door landing.<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-2-1 (originally 3)<br />

3


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-2-2 (originally 4)<br />

4


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

3. Identification Symbols, Restrooms - Men’s Restroom at <strong>PE</strong> Utilities<br />

Building.<br />

Memo:<br />

Areas noted in compliance:<br />

Door mounted signage: Men’s - Equilateral triangle with 12” sides, 1/4” thick with the vertex pointing up. The triangle<br />

symbol contrasts with the door, light on dark background or dark on light background.<br />

Areas not meeting new construction standards:<br />

Signs are centered on door 60” from floor. (67”.)<br />

Wall mounted signage: Symbol of accessibility is mounted on wall sign adjacent to latch side of door. (No wall sign.)<br />

Recommendation:<br />

Install wall-mounted sign at single entrance.<br />

Relocate existing signage.<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-3-1 (originally 5)<br />

5


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

4. Multiple Accommodation Toilets - Men’s Restroom at <strong>PE</strong> Utilities<br />

Building.<br />

Memo:<br />

Areas noted in compliance:<br />

60” min. diameter turning circle clear of objects from floor height to 27” in room.<br />

Door latch is a flip-over style, sliding or other hardware not requiring tight grasping or twisting.<br />

Door has loop or U-shaped handle immediately below latch on both inside and outside of door.<br />

32” minimum opening at end.<br />

The clear floor area on the pull side of the door is the width of the door and a minimum 60” deep.<br />

The clear floor area on the strike side of the door is a minimum 18” wide and a minimum 60” deep.<br />

The clear floor area on the push side of the door within the stall is the width of the door and a minimum 48” deep.<br />

If the compartment has an end opening door (facing the water closet), a minimum 60” wide x 48”deep clear floor<br />

space is provided in front of the water closet.<br />

60” minimum width of stall.<br />

32” minimum from side of water closet to opposite wall or partition.<br />

42” minimum from centerline of water closet to opposite wall or partition.<br />

The top of the toilet seat is 17” - 19” from the floor surface as measured to the top of a maximum 2” high toilet<br />

seat (a 3” high seat shall be permitted only in alterations where the existing fixture is less than 15” high).<br />

Flush valve is on wide side of the water closet.<br />

44” maximum height to flush valve and 5 lb maximum force to operate the flush valve.<br />

Front of toilet paper dispenser is within 36” of back wall.<br />

19” minimum height to toilet paper dispenser.<br />

Toilet paper dispenser provides continuous flow.<br />

Areas not meeting new construction standards:<br />

44” min. clear path provided throughout facility. (35-1/2”.)<br />

3 second min. automatic closing door. (No closing hinge.)<br />

18” betwen centerline of water closet and side wall or partition. (15-1/4”.)<br />

The toilet paper dispenser is located on the side wall below the grab bar and within 12” of the front of the toilet<br />

seat.<br />

6


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

Relocate water closet.<br />

Provide a closer at the stall door.<br />

Relocate the toilet paper dispenser away from the top of the grab bars or proposed grab bars.<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-4-1 (originally 6)<br />

7


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-4-2 (originally 7)<br />

8


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

5. Toilet Grab Bars - Men’s Restroom at <strong>PE</strong> Utilities Building.<br />

Memo:<br />

One continuous bar. See Sequence #4 for additional recommendations.<br />

Areas noted in compliance:<br />

1-1/4” to 1-1/2” diameter of bars.<br />

1-1/2” clearance between bars and each wall or partition.<br />

The side grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor.<br />

The rear grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor (for<br />

tank type toilets, 36” may be allowed if tank obstructs placement of bar).<br />

Side bar has 42” min. length.<br />

Side bar begins a max. of 12” from back wall.<br />

Back bar has 36” min. length.<br />

Back bar begins a max. of 6” from side wall.<br />

Bars are smooth with a min. edge radius of 1/8”.<br />

Grab bars do not rotate within their fittings.<br />

Min. structural strength to support 250 lb. point load.<br />

Surface of wall adjacent to grab bars are free of sharp or abrasive elements.<br />

Areas not meeting new construction standards:<br />

The front of the side grab bar extends 52” from back wall in multiple accommodation restroom. (50”.)<br />

Area directly above grab bars or proposed grab bars is free of protruding obstructions to a height of 18” (recessed<br />

items are allowed). (Toilet paper and seat cover dispensers.)<br />

Recommendation:<br />

Relocate grab bar.<br />

Relocate the seat cover dispenser away from the top of the grab bars or proposed grab bars.<br />

9


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-5-1 (originally 8)<br />

10


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

6. Lavatories - Men’s Restroom at <strong>PE</strong> Utilities Building.<br />

Memo:<br />

Areas noted in compliance:<br />

Required clear space extends 19” max. underneath the lavatory and adjoins or over laps an accessible route.<br />

18” minimum from center of fixture to side wall or partition.<br />

34” max. height to rim or counter above floor surface.<br />

29” min. clearance from bottom of apron to floor surface.<br />

30” wide x 9” high x 17” deep clearance from front of lavatory.<br />

Drain and piping is insulated or configured to prevent contact.<br />

There are no sharp or abrasive elements under lavatory.<br />

Faucets are lever type, electronically activated or approved self closing valves (10 second open flow).<br />

Faucets are operable with one hand and do not require tight grasping, pinching or twisting of wrist.<br />

5 lb. max. force required to operate controls.<br />

Areas not meeting new construction standards:<br />

30” x 48” min. clear space provided in front of lavatory that allows forward approach (doors may not encroach into this<br />

space).<br />

27” high x 8” deep knee clearance under front lip. (26-3/4” high.)<br />

Recommendation:<br />

Raise/Lower existing lavatory.<br />

11


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-6-1 (originally 9)<br />

12


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

7. Urinals - Men’s Restroom at <strong>PE</strong> Utilities Building.<br />

Memo:<br />

Areas noted in compliance:<br />

A clear floor space that is a minimum 30” wide by 48” deep is provided in front of the urinal to allow forward approach.<br />

44” maximum height to flush valve above finished floor.<br />

5 lb max. pressure to operate valve.<br />

Walls within 24” of front and sides of urinals are smooth, hard and non-absorbent to 48” height, and are not adversely<br />

affected by moisture.<br />

Areas not meeting new construction standards:<br />

17” maximum urinal rim height above the finished floor. (21”.)<br />

14” minimum projection and 17” maximum projection from the wall. (20-1/2”.)<br />

Recommendation:<br />

Replace/Install urinal.<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-7-1 (originally 10)<br />

13


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

8. Accessories - Men’s Restroom at <strong>PE</strong> Utilities Building.<br />

Memo:<br />

Areas noted in compliance:<br />

Coat hooks and shelving are located within appropriate reach ranges (48” max. height above floor surface is recommended).<br />

Accessories do not require tight grasping, pinching or twisting of the wrist to operate.<br />

A minimum 30” x 48” minimum clear floor or ground space is provided to allow forward or parallel approach to accessories.<br />

A maximum of 5 lbs. force is required to operate mechanisms.<br />

Areas not meeting new construction standards:<br />

40” max. height to all other fixtures (i.e., soap dispensers, towels, toilet seat covers, auto dryers, sanitary napkins, waste<br />

recepatacles, etc.). (Paper towel dispenser - 40-1/2” - 52” / soap dispenser - 41”.)<br />

Recommendation:<br />

Relocate the paper towel dispenser / hand dryer.<br />

Relocate the soap dispenser.<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-8-1 (originally 11)<br />

14


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

9. Electrical Controls & Receptacles/Fire Alarm Boxes - Men’s Restroom<br />

at <strong>PE</strong> Utilities Building.<br />

Memo:<br />

Areas noted in compliance:<br />

The center of electrical receptacles or controls, and switches to control lighting, heating, cooling & appliances are 48”<br />

max. above the floor or working platform.<br />

The center of electrical outlets intended to be used by the room occupant are located a min. of 15” above the floor<br />

or working platform.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-9-1 (originally 14)<br />

15


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-9-2 (originally 15)<br />

16


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

10. Water Fountains (Drinking) - At <strong>PE</strong> Utilities Building.<br />

Memo:<br />

Areas noted in compliance:<br />

27” high x 8” deep clear knee space under fountain.<br />

9” high x 17” deep toe clearance.<br />

Lever or push bar control is located 6” max. from front edge.<br />

Bubbler outlet is 6” maximum from front.<br />

Stream of bubbler is parallel to front edge.<br />

4” minimum height of stream.<br />

The force required to activate controls does not exceed 5lbf.<br />

Two fountains are provided, one that is wheelchair accessible and one at normal height for those persons having difficulty<br />

bending or stooping.<br />

Areas not meeting new construction standards:<br />

32” minimum wide and 18” minimum deep alcove provided.<br />

18” minimum depth of fountain. (13”.)<br />

Bubbler outlet is 36” maximum from floor. (39”.)<br />

Recommendation:<br />

Install new HI-LO drinking fountain.<br />

Install cane-detectable barrier around fountain.<br />

17


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-10-1 (originally 16)<br />

18


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

11. Doors - Women’s Restroom at <strong>PE</strong> Utilities Building.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

32” minimum clear width of doorway.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch.<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2. (1-1/2”.)<br />

5 lb. maximum pressure to operate exterior doors. (19 lbs.)<br />

Recommendation:<br />

Install level exterior door landing.<br />

Adjust door for opening pressure/closing times unless accepted by DSA / Fire Life Safety.<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-11-1 (originally 17)<br />

19


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-11-2 (originally 18)<br />

20


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

12. Clear Space at Doors - Women’s Restroom at <strong>PE</strong> Utilities Building.<br />

Memo:<br />

See Sequence #11 for recommendations.<br />

Areas noted in compliance:<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PULL side of door: 24” exterior doors.<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

Floor or landing is level and clear (2% max. slope). (3.1%.)<br />

Recommendation:<br />

None.<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-12-1 (originally 19)<br />

21


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-12-2 (originally 20)<br />

22


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

13. Identification Symbols, Restrooms - Women’s Restroom at <strong>PE</strong><br />

Utilities Building.<br />

Memo:<br />

Areas noted in compliance:<br />

Women’s - 12” diameter circle 1/4” thick. The circle symbol contrasts with the door, light on dark background or dark<br />

on light background.<br />

Areas not meeting new construction standards:<br />

Signs are centered on door 60” from floor. (67”.)<br />

Wall mounted signage: Symbol of accessibility is mounted on wall sign adjacent to latch side of door. (No wall sign.)<br />

Recommendation:<br />

Install wall-mounted sign at single entrance.<br />

Relocate existing signage.<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-13-1 (originally 21)<br />

23


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

14. Multiple Accommodation Toilets - Women’s Restroom at <strong>PE</strong> Utilities<br />

Building.<br />

Memo:<br />

Areas noted in compliance:<br />

60” min. diameter turning circle clear of objects from floor height to 27” in room.<br />

Door latch is a flip-over style, sliding or other hardware not requiring tight grasping or twisting.<br />

32” minimum opening at end.<br />

The clear floor area on the pull side of the door is the width of the door and a minimum 60” deep.<br />

The clear floor area on the strike side of the door is a minimum 18” wide and a minimum 60” deep.<br />

60” minimum width of stall.<br />

32” minimum from side of water closet to opposite wall or partition.<br />

42” minimum from centerline of water closet to opposite wall or partition.<br />

The top of the toilet seat is 17” - 19” from the floor surface as measured to the top of a maximum 2” high toilet<br />

seat (a 3” high seat shall be permitted only in alterations where the existing fixture is less than 15” high).<br />

Flush valve is on wide side of the water closet.<br />

44” maximum height to flush valve and 5 lb maximum force to operate the flush valve.<br />

Front of toilet paper dispenser is within 36” of back wall.<br />

19” minimum height to toilet paper dispenser.<br />

Toilet paper dispenser provides continuous flow.<br />

Areas not meeting new construction standards:<br />

44” min. clear path provided throughout facility.<br />

3 second min. automatic closing door. (No closing hinge.)<br />

Door has loop or U-shaped handle immediately below latch on both inside and outside of door. (None.)<br />

The clear floor area on the push side of the door within the stall is the width of the door and a minimum 48” deep.<br />

(44”.)<br />

If the compartment has an end opening door (facing the water closet), a minimum 60” wide x 48”deep clear floor<br />

space is provided in front of the water closet. (44” deep.)<br />

18” betwen centerline of water closet and side wall or partition. (15-1/2”.)<br />

The toilet paper dispenser is located on the side wall below the grab bar and within 12” of the front of the toilet<br />

seat.<br />

24


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />

Replace/Install stall door hardware.<br />

Relocate water closet.<br />

Provide a closer at the stall door.<br />

Relocate the toilet paper dispenser away from the top of the grab bars or proposed grab bars.<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-14-1 (originally 22)<br />

25


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-14-2 (originally 23)<br />

26


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

15. Toilet Grab Bars - Women’s Restroom at <strong>PE</strong> Utilities Building.<br />

Memo:<br />

Continuous grab bar. See Sequence #14 for additional recommendations.<br />

Areas noted in compliance:<br />

1-1/4” to 1-1/2” diameter of bars.<br />

1-1/2” clearance between bars and each wall or partition.<br />

The side grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor.<br />

The rear grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor (for<br />

tank type toilets, 36” may be allowed if tank obstructs placement of bar).<br />

Side bar has 42” min. length.<br />

Side bar begins a max. of 12” from back wall.<br />

Back bar has 36” min. length.<br />

Back bar begins a max. of 6” from side wall.<br />

Bars are smooth with a min. edge radius of 1/8”.<br />

Grab bars do not rotate within their fittings.<br />

Min. structural strength to support 250 lb. point load.<br />

Surface of wall adjacent to grab bars are free of sharp or abrasive elements.<br />

Areas not meeting new construction standards:<br />

The front of the side grab bar extends 52” from back wall in multiple accommodation restroom. (50”.)<br />

Area directly above grab bars or proposed grab bars is free of protruding obstructions to a height of 18” (recessed<br />

items are allowed). (Toilet paper and seat cover dispensers.)<br />

Recommendation:<br />

Replace/Install grab bar.<br />

Relocate the seat cover dispenser away from the top of the grab bars or proposed grab bars.<br />

Relocate the toilet paper dispenser away from the top of the grab bars or proposed grab bars.<br />

27


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-15-1 (originally 24)<br />

28


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

16. Lavatories - Women’s Restroom at <strong>PE</strong> Utilities Building.<br />

Memo:<br />

Areas noted in compliance:<br />

30” x 48” min. clear space provided in front of lavatory that allows forward approach (doors may not encroach into this<br />

space).<br />

Required clear space extends 19” max. underneath the lavatory and adjoins or over laps an accessible route.<br />

18” minimum from center of fixture to side wall or partition.<br />

34” max. height to rim or counter above floor surface.<br />

29” min. clearance from bottom of apron to floor surface.<br />

27” high x 8” deep knee clearance under front lip.<br />

30” wide x 9” high x 17” deep clearance from front of lavatory.<br />

Drain and piping is insulated or configured to prevent contact.<br />

There are no sharp or abrasive elements under lavatory.<br />

Faucets are lever type, electronically activated or approved self closing valves (10 second open flow).<br />

Faucets are operable with one hand and do not require tight grasping, pinching or twisting of wrist.<br />

5 lb. max. force required to operate controls.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

29


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-16-1 (originally 25)<br />

30


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

17. Accessories - Women’s Restroom at <strong>PE</strong> Utilities Building.<br />

Memo:<br />

Areas noted in compliance:<br />

40” maximum height to bottom of reflective surface of mirror.<br />

Accessories do not require tight grasping, pinching or twisting of the wrist to operate.<br />

A minimum 30” x 48” minimum clear floor or ground space is provided to allow forward or parallel approach to accessories.<br />

A maximum of 5 lbs. force is required to operate mechanisms.<br />

Areas not meeting new construction standards:<br />

40” max. height to all other fixtures (i.e., soap dispensers, towels, toilet seat covers, auto dryers, sanitary napkins, waste<br />

recepatacles, etc.). (Soap dispenser - 41” / paper towel dispenser - 42”.)<br />

height above floor surface is recom-<br />

Coat hooks and shelving are located within appropriate reach ranges (48” max.<br />

mended). (58-1/2”.)<br />

Recommendation:<br />

Relocate the soap dispenser.<br />

Relocate the paper towel dispenser / hand dryer.<br />

Install accessible coat hook.<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-17-1 (originally 26)<br />

31


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

18. Electrical Controls & Receptacles/Fire Alarm Boxes - Women’s<br />

Restroom at <strong>PE</strong> Utilities Building.<br />

Memo:<br />

Areas noted in compliance:<br />

The center of electrical receptacles or controls, and switches to control lighting, heating, cooling & appliances are 48”<br />

max. above the floor or working platform.<br />

The center of electrical outlets intended to be used by the room occupant are located a min. of 15” above the floor<br />

or working platform.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-18-1 (originally 27)<br />

32


University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />

900 University Avenue<br />

Photo #UCR P5496 <strong>PE</strong> Utilities Building-18-2 (originally 28)<br />

33