APPENDIX 4 – SECONDARY TREATMENT SYSTEMS<br />
One option <strong>for</strong> a secondary treatment system that collects, treats and dis<strong>in</strong>fects greywater<br />
to a standard <strong>of</strong> 20 mg/L BOD5, 30 mg/L SS and 10 cfu <strong>the</strong>rmotolerant coli<strong>for</strong>ms / 100mL<br />
prior to irrigation via drip and/or surface irrigation methods is detailed below.<br />
Conversion <strong>of</strong> Aerobic Treatment Units (ATU) systems to greywater systems<br />
The conversion <strong>of</strong> disused ATU’s to greywater systems is permitted subject to <strong>the</strong><br />
follow<strong>in</strong>g:<br />
●<br />
●<br />
●<br />
The ATU is to be <strong>in</strong>stalled, operated and ma<strong>in</strong>ta<strong>in</strong>ed <strong>in</strong> accordance with <strong>the</strong> “Code <strong>of</strong><br />
Practice <strong>for</strong> <strong>the</strong> Design, Manufacture, Installation and Operation <strong>of</strong> Aerobic Treatment<br />
Units Serv<strong>in</strong>g S<strong>in</strong>gle Dwell<strong>in</strong>gs” November 2001.<br />
The effluent quality prescribed <strong>for</strong> ATU’s must cont<strong>in</strong>ue to be ma<strong>in</strong>ta<strong>in</strong>ed.<br />
Desludg<strong>in</strong>g <strong>of</strong> ATU’s to allow conversion is not necessary.<br />