29.10.2014 Views

Variable displacement pumps - Total Hydraulics BV

Variable displacement pumps - Total Hydraulics BV

Variable displacement pumps - Total Hydraulics BV

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TXV series <strong>pumps</strong><br />

main characteristics<br />

Pump<br />

■■standard pump range<br />

TXV 40<br />

TXV 60<br />

TXV 75<br />

TXV 92<br />

TXV 120<br />

TXV 130<br />

TXV 150<br />

0512950<br />

0512955<br />

0512500<br />

0512505<br />

0512510<br />

0512515<br />

0512520<br />

0512525<br />

0515700<br />

0515705<br />

0515300<br />

0515515<br />

0518600<br />

0518605<br />

■■with through shaft<br />

0518700<br />

TXV 130<br />

0518705<br />

Direction<br />

of rotation<br />

SH<br />

SIH<br />

SH<br />

SIH<br />

SH<br />

SIH<br />

SH<br />

SIH<br />

SH<br />

SIH<br />

SH<br />

SIH<br />

SH<br />

SIH<br />

SH<br />

SIH<br />

Displacement (1)<br />

maxi<br />

(cc)<br />

Maximum<br />

operating<br />

pressure<br />

(bar)<br />

Maximum<br />

peak pressure<br />

(intermittent : 5%)<br />

(bar)<br />

Maximum<br />

operating<br />

pressure at<br />

flow-cancellation<br />

(bar)<br />

Max torque<br />

at 300 bar<br />

(Nm)<br />

Max<br />

speed (2)<br />

(rpm)<br />

Weight<br />

(kg)<br />

Overhang<br />

torque<br />

(N.m)<br />

40 400 420 440 220 3000 26.8 35<br />

60 400 420 440 295 2600 26.8 35<br />

75 400 420 440 410 2000 26.8 35<br />

92 380 400 420 483 1900 26.8 35<br />

120 360 380 400 680 2100 26.8 35<br />

130 360 380 400 730 2100 27.2 35<br />

150 310 330 350 840 2000 27.2 35<br />

130 360 380 400 730 1900 31.1 47.4 (3)<br />

(1) TXV <strong>pumps</strong> can be set for smaller maximum <strong>displacement</strong>s: please contact us.<br />

(2) Higher speed possible depending on flow required : please contact us<br />

(3) Overhang torque of the pump only.<br />

Viscosity affects maximum possible rotating speed. If viscosity > 150 cSt, please contact us to obtain corresponding speed possibilities.<br />

4<br />

■■Setting pump maximum <strong>displacement</strong><br />

The TXV <strong>pumps</strong> from 40cc to 120cc are made as standard to be able to use<br />

the setting screw reference 0518386.<br />

The pump <strong>displacement</strong> can thus be adjusted to exactly what is needed.<br />

■■How to use the setting screw<br />

Unscrew 1 completely, loosen 3 and screw 2 to the required <strong>displacement</strong>.<br />

See figure above.<br />

For TXV: 1 turn of the screw changes the <strong>displacement</strong> by 9 cc.<br />

For TXV92 to TXV40: 1 turn of the screw changes the <strong>displacement</strong> by 8 cc.<br />

Back of the pump<br />

1 2 3<br />

X<br />

Displacement of the pump in cc<br />

120<br />

110<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

16 18 20 22 24 26 28 30 32 34 36 38<br />

Dimension X - mm<br />

TXV 120<br />

TXV 92