Get the Focus<br />

Biometra Imaging <strong>Systems</strong><br />

Perfect for Every Lab<br />

Innovation · Advancement · Development


www.biometra.com<br />

<strong>Gel</strong> Imaging <strong>Systems</strong><br />

Biometra offers a wide range of high performance systems for documentation and<br />

analysis of electrophoresis gels and blots. The systems are focussed on the needs of<br />

everyday imaging applications in teaching and routine laboratories as well as demanding<br />

tasks in science and research. The latest software release even more demonstrates that<br />

a highly versatile software can also be applied without any detailed training. The wellthought-out<br />

software interface allows a quick and easy professional gel analysis.<br />

Choose the perfect solution for your lab.<br />

<strong>Documentation</strong> and analysis of<br />

Fluorescence and white light application<br />

electrophoresis gels (agarose, polyacrylamide) blots radiographs<br />

Applicable for<br />

UV-fluorescent dyes, e.g. ethidium bromide, SYBR ® Green<br />

colorimetric detection, e.g. silver stain, Coomassie Blue<br />

<strong>Documentation</strong><br />

<strong>Documentation</strong> + analysis<br />

UVsolo TS<br />

Scientific grade monochrome<br />

CCD camera<br />

Stand-alone system without PC<br />

BDAdigital<br />

Up-to-date digital SLR colour camera<br />

with great performance lens<br />

Outstanding high image resolution<br />

BDA live<br />

Digital scientific grade<br />

monochrome CCD camera<br />

High image resolution with<br />

extended dynamic range<br />

Real-time image<br />

Real-time image preview<br />

Real-time image<br />

Touch Screen operation<br />

<strong>Gel</strong> viewing window and side doors<br />

for cutting gels<br />

Saving images on USB stick, internal<br />

system memory or via network<br />

Perfect for multi-user environments<br />

Advanced software control<br />

of camera<br />

Independend use of the<br />

camera possible<br />

Modular system for cost-effective<br />

digital imaging<br />

Powerful gel analysis software<br />

included<br />

Extra light sensitive<br />

manual zoom<br />

Fast and easy image acquisition<br />

Modular system with cost-effective<br />

hood or with advanced darkhood<br />

Powerful gel analysis software<br />

included (2x)<br />

Innovation · Advancement · Development


BioDocAnalyze Software<br />

NEW! BDA-Software-Upgrade 2011<br />

BioDocAnalyze (BDA)<br />

The BioDocAnalyze (BDA) software is<br />

powerful in imaging and analysing<br />

1D electrophoresis gels and blots. The<br />

latest software upgrade introduced even<br />

some more benefits. For an easy use of the<br />

full functional range of different camera<br />

types it provides specific image capture<br />

windows for BDAdigital and BDA live.<br />

The gel analysis software is already included<br />

in BDAdigital and BDA live systems. But it<br />

can also be used on separate computers<br />

for images taken with the documentation<br />

system UVsolo TS or with other devices.<br />

The BDA software is developed for an<br />

intuitive and reliable analysis of gels and<br />

blots. Files with compatible formats jpg,<br />

tif and bmp can be imported into the BDA<br />

analysis software.<br />

Defining of lanes and bands is a matter<br />

of seconds. Clearly defined buttons for all<br />

important functions allow a complete gel<br />

analysis with a few mouse-clicks.<br />

Detected bands are not only marked with<br />

a line but are encircled in their whole area.<br />

For maximum flexibility it is also possible<br />

to encircle bands free-hand. The automatic<br />

background deduction ensures accurate<br />

scientific quantification. Normalization of<br />

bands allows a fast comparison of samples.<br />

Analysis results are displayed on the gel or<br />

in a result table which can be exported to<br />

Microsoft ® Excel. Comments, annotations<br />

and arrows can be freely added to the<br />

image in a wide range of formats.<br />

The new merging function is especially of<br />

help for analysis of chemiluminescence<br />

blots: Different images or frames and an<br />

image can be overlayed, aligned and<br />

merged. This way it is possible to add<br />

marker lanes acquired with visible light to<br />

imported images with chemiluminescence<br />

signals.<br />

Features<br />

Automatic lane and band recognition<br />

Add, delete and separate lanes and bands<br />

Optimisation of detection parameters<br />

Automatic background adjustment<br />

Automatic calculation for size/MW, mass, Rf<br />

Compensation of smiling and distorted gels<br />

Zoom and invert function<br />

Import of TIF, JPG, and BMP files,<br />

export of TIF files<br />

Data export to MS Excel<br />

Printing of images and data tables<br />

Add annotations to lanes, bands and gel image<br />

Saving of comment formats and<br />

comment samples<br />

Creating of frames<br />

Overlay and merging of gel images<br />

Simultaneous display of intensity profiles<br />

of lanes<br />

Similarity Analysis –<br />

upgrade module<br />

The standard BioDocAnalyze software can<br />

be upgraded with the Similarity Analysis<br />

Module for comparison and matching of<br />

fragment patterns.<br />

This extremely fast and easy to use<br />

software analyses fingerprint gels, e.g.<br />

RFLP patterns, with one mouse click.<br />

Features<br />

Similarity analysis according to Rf or molecular<br />

weight of bands<br />

Cluster analysis (UPGMA, Neighbour Joining)<br />

Similarity and distance matrix<br />

0/1 matrix<br />

Reference lanes, lane list<br />

Correlation coefficients<br />

Pearson, Dice, Jaccard, Cosine, Overlap<br />

Export and printing of tables and dendrograms<br />

Innovation · Advancement · Development


Technical Specification<br />

High-resolution digital thermal printer for<br />

prints in photo-quality<br />

Converter plate for documentation of gels<br />

with non-fluorescent stains.<br />

Wide choice of UVstar transilluminators<br />

Scope of application<br />

Sample dye UVsolo TS BDAdigital BDA live<br />

Fluorescent + + +<br />

Coloured + + +<br />

Scope of delivery<br />

Item<br />

UVsolo TS<br />

BDAdigital<br />

core set<br />

Camera<br />

Digital scientific<br />

grade CCD<br />

camera<br />

Image<br />

Acquisition<br />

Software<br />

<strong>Gel</strong><br />

Analysis<br />

Computer,<br />

TFT monitor<br />

Darkhood<br />

Transilluminator<br />

Thermal<br />

printer<br />

UV converter<br />

plate<br />

Yes Optional n.a. Incl. controller Yes Optional Optional<br />

Yes Yes Optional Optional Optional Optional Optional<br />

BDAdigital<br />

compact<br />

BDAdigital<br />

systems<br />

Digital<br />

single lens<br />

reflex camera<br />

Yes Yes Optional<br />

Small<br />

BDA Hood<br />

Optional Optional Optional<br />

Yes Yes Yes BDA Box 2 Yes Yes Yes<br />

BDA live<br />

core sets<br />

BDA live<br />

compact<br />

BDA live<br />

systems<br />

Digital scientific<br />

grade CCD<br />

camera<br />

Yes Yes (2x) Optional Optional Optional Optional Optional<br />

Yes Yes (2x) Optional<br />

Small<br />

BDA Hood<br />

Optional Optional Optional<br />

Yes Yes (2x) Yes BDA Box 2 Yes Yes Yes<br />

n.a.: not applicable<br />

For detailed information please refer to the Biometra catalogue or to the specific product flyers.<br />

Biometra GmbH<br />

Rudolf-Wissell-Str. 30 · D-37079 Göttingen · Germany<br />

Tel. +49 551- 50686-0 · Fax +49 551- 50686-66<br />

info@biometra.com · www.biometra.com<br />

Innovation · Advancement · Development<br />

P.O.S. kresin DESIGN GmbH · P1104-042