Conductivity measuring devices - Iberica de Automatismos
Conductivity measuring devices - Iberica de Automatismos
Conductivity measuring devices - Iberica de Automatismos
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Handheld instrument<br />
Display / Controller<br />
WK<br />
<strong>Conductivity</strong> <strong>measuring</strong> <strong><strong>de</strong>vices</strong><br />
• Wi<strong>de</strong> <strong>measuring</strong> range from 0,0 µS/cm to 200,0 mS/cm<br />
manually selectable or automatic range selection<br />
• Double display for conductivity and temperature<br />
• Display of resistance, salinity or TDS (dry residue of filtrate) (for GMH3430)<br />
• Conform to the regulations of the drinking water ordinance (TrinkwV 2001)<br />
and DIN EN 27888<br />
• Automatic temperature compensation, reference temp. (20°C/25°C) selectable<br />
• Setting of different temperature coefficients (for GMH3430)<br />
• Extremely small <strong>measuring</strong> probe (dimensions as for pH-probe)<br />
• Min./Max. value memory, Hold function,<br />
• Serial interface, <strong>de</strong>vice can be connected to bus system (up to 5 <strong><strong>de</strong>vices</strong><br />
can be connected to one PC interface)<br />
• Battery and d.c. operation<br />
Alarm / Protection Temperature probe<br />
Transmitter<br />
Logger / EASYBus<br />
GMH 3410<br />
GMH 3430<br />
Specification:<br />
Measuring range:<br />
<strong>Conductivity</strong>: 0,0 ... 200,0 µS/cm<br />
0 ... 2000 µS/cm<br />
0,00 ... 20,00 mS/cm<br />
0,0 ... 200,0 mS/cm<br />
manual setting or auto range<br />
Temperature: -5,0 ... +100,0°C<br />
Resistance: ( GMH3430) 0,005 ... 100,0 kOhm<br />
Salinity: ( GMH3430) 0,0 ... 70,0<br />
TDS: ( GMH3430)<br />
Resolution:<br />
0 ... 1999 mg/l<br />
0,1 µS/cm; 1 µS/cm; 10 µS/cm or 0,1mS/cm<br />
0,1 °C<br />
0,001 kOhm; 0,01 kOhm or 0,1 kOhm<br />
0,1 (salinity)<br />
1 mg/l<br />
Accuracy: ( ±1digit) (at nominal temperature = 25°C)<br />
<strong>Conductivity</strong>: ±0,5% of m.v. ±0,3% FS or ±2µS/cm<br />
Temperature: ±0,2% of m.v. ±0,3K<br />
Cell constant: adjustable from 0.800 ... 1.200 cm -1<br />
Temp. compensation: automatic or off (GMH3430).<br />
Compensation coefficient:<br />
- nLF: non-linear function of natural water according to<br />
EN27888 (DIN38404).<br />
- Lin: linear compensation from 0,3 ... 3,0 %/K. (GMH3430 only)<br />
- off: no compensation. (GMH3430 only)<br />
Display: 2 four digit LCDs (12.4mm and 7mm high) for conductivity<br />
(resistance, salinity, TDS) and temperature, min./ max values, hold<br />
function, etc. as well as additional functional arrows.<br />
Measuring cell: 2-pol conductivity <strong>measuring</strong> cell; temperature<br />
sensor integrated in shaft. Electro<strong>de</strong> material: graphite.<br />
The graphite electro<strong>de</strong>s are the optimum solution for sewage and<br />
can be cleaned easily.<br />
Working temperature:0 to +50°C (<strong>de</strong>vice)<br />
meas. cell: 0 to +80°C (permanent) 0 to +100° C (short time)<br />
Relative humidity: 0 to +95%RH (non-con<strong>de</strong>nsing)<br />
Storage temperature: -20 to +70°C<br />
Min/Max-value memory: max. and min. values as well as the corresponding<br />
temperature will be memorized.<br />
Hold function: by pressing a button the current meas. value and<br />
the corresponding temperature will be 'frozen'.<br />
Interface: serial interface, direct connection to RS232 or USB interface<br />
of a PC via electrically isolated interface converter GRS3100<br />
or GRS3105 resp. USB3100 (p.r.t. accessories).<br />
Difference between GMH 3430 and GMH 3410:<br />
Additional features of GMH 3430:<br />
• Determination of resistance, salinity and TDS.<br />
• The following temperature coefficients are freely selectable:<br />
natural waters, linear compensation or to be <strong>de</strong>activated.<br />
Pushbuttons: 6 membrane keys for ON/OFF-switch, selection of<br />
meas. range, min- and max-value memory, hold-function, etc.<br />
Power supply: 9V-battery, type IEC 6F22 (inclu<strong>de</strong>d) as well as<br />
additional d.c. connector (internal pin Ø 1.9mm) for external 10.5-12V<br />
direct voltage supply. (suitable power supply: GNG10/3000)<br />
Power-Off-function: Device will be automatically switched off if no<br />
key is pressed/no interface communication takes place for the time<br />
of the power-off <strong>de</strong>lay. The power-off <strong>de</strong>lay can be set to values<br />
between 1 and 120 min.; it can be completely <strong>de</strong>activated.<br />
Low battery warning: and ' bAt '<br />
Power consumption: approx. 3.5 mA (meas. power not incl.)<br />
Housing dimensions (<strong>de</strong>vice): 142 x 71 x 26 mm (H x W x D)<br />
Impact-resistant ABS plastic housing, membrane keyboard, transparent<br />
panel. Front si<strong>de</strong> IP65, integrated pop-up clip for table top<br />
or suspen<strong>de</strong>d use.<br />
Electro<strong>de</strong> dim.: approx. 120mm long, Ø approx. 12mm, 1m of<br />
fixed connection cable between electro<strong>de</strong> and <strong>de</strong>vice.<br />
Weight: approx. 255 g (incl. batteries and <strong>measuring</strong> cell)<br />
Automatic temperature compensation: The conductivity is<br />
highly <strong>de</strong>pendant on the temperature, i.e. it is only valid for one<br />
temperature. For better comparison the <strong>de</strong>vice offers the possibility<br />
to compensate the conductivity to a reference temperature (adjustable<br />
20°C or 25°C).<br />
Temperature measurement: The temperature of the agent can be<br />
displayed by means of the temperature probe integrated in the electro<strong>de</strong>.<br />
AutoRange: Automatic selection of to the optimum meas. range<br />
for conductivity measurements. AutoRange mo<strong>de</strong> can be <strong>de</strong>activated<br />
by pressing a button.<br />
Salinity <strong>de</strong>termination (GMH3430 only): Salinity is un<strong>de</strong>rstood to be the<br />
sum of concentrations of all salts dissolved in water. Reading in g/kg.<br />
TDS-<strong>de</strong>termination (dry residue of filtrate) (GMH3430 only): The dry residue<br />
of filtrate is un<strong>de</strong>rstood to be the concentration of substances<br />
dissolved in a liquid. Reading in mg/l.<br />
Accessories:<br />
GKL 100 100ml conductivity control solution<br />
(100ml bottles with 1413 µS/cm. (pursuant to DIN EN 27888))<br />
miscellaneous accessories (case, power supply, etc.)<br />
suitable for all GMH3xxx <strong><strong>de</strong>vices</strong> p.r.t. p. 39 -41<br />
32
N E W<br />
<strong>Conductivity</strong> <strong>measuring</strong> <strong><strong>de</strong>vices</strong><br />
WK<br />
Highlights:<br />
• 3 conductivity <strong>measuring</strong> ranges<br />
• Low power consumption<br />
• Automatic <strong>measuring</strong> range change-over<br />
• Min/max-value memory<br />
• Automatic temperature compensation<br />
via integrated temperature sensor<br />
• Hold function<br />
• Adjustable<br />
N E W<br />
Handheld instrument<br />
Display / Controller<br />
Area of application:<br />
• Fresh and sea water aquaristics<br />
• Fish farming / water monitoring<br />
• Drink water monitoring, etc.<br />
GLF 100<br />
GLF 100 RW<br />
Universal conductivity <strong>measuring</strong> <strong>de</strong>vice<br />
<strong>Conductivity</strong> meter for ultra-pure water<br />
Area of application:<br />
• Checking of pure and ultra-pure water<br />
• Checking of boiler water<br />
• Functional check of ion exchangers<br />
Logger / EASYBus<br />
Specification GLF 100 GLF 100 RW<br />
Measuring ranges:<br />
<strong>Conductivity</strong>: 0 ... 2000 µS/cm 0.000 ... 2.000 µS/cm<br />
0.00 ... 20.00 mS/cm 0.00 ... 20.00 µS/cm<br />
0.0 ... 100.0 mS/cm 0.0 ... 100.0 µS/cm<br />
Temperature: -5.0 ... +100.0 °C -5.0 ... +100.0 °C<br />
TDS: 0 ... 2000 mg/l --<br />
Salinity: 0.0 ... 50.0 g/kg --<br />
Resistivity: -- 0.0100 ... 0.2000 MΩ*cm<br />
-- 0.010 ... 2.000 MΩ*cm<br />
-- 0.01 ... 20.00 MΩ*cm<br />
Accuracy: (±1 digit, at nominal temperature = 25 °C)<br />
<strong>Conductivity</strong>: ±0.5 % of m.v. ±0,5 % FS typ. ±1% of m.v. ±0,5 % FS<br />
Temperature: ±0.3 °C ±0.3 °C<br />
Temp.-compensation: off: <strong>de</strong>activated off: <strong>de</strong>activated<br />
nLF: non-linear, acc. to EN 27888 nLF: non-linear, acc. to EN 27888<br />
-- LIN: linear, with adjustable<br />
coefficients<br />
-- NaCl: compensation for weak<br />
NaCl-solutions acc. to EN 60746-3<br />
Reference temperatures: 20 and 25 °C 20 and 25 °C<br />
Measuring cell: 2-pole <strong>measuring</strong> cell, 2-pole <strong>measuring</strong> cell, Ø 12 mm<br />
Ø 12 mm (graphite) (stainless steel: 1.4404, 1.4435)<br />
with integrated temperature sensor with integrated temperature sensor<br />
Display:<br />
approx. 11 mm high, 4½-digit LCD-display<br />
Working conditions<br />
Device:<br />
-25 ... +50 °C, 0 ... 95 % RH (non con<strong>de</strong>nsing)<br />
Measuring cell: -5 ... +80 °C (for short-time: 100 °C)<br />
Power supply: 9V-battery, type 6F22 (in scope of supply)<br />
Power consumption: < 1.5 mA<br />
Housing:<br />
impact resistant ABS, membrane keyboard, transparent panel, front si<strong>de</strong> IP65<br />
Dimensions (<strong>de</strong>vice): 110 x 67 x 30 mm (H x W x D)<br />
Weight:<br />
approx. 155 g<br />
Device functions:<br />
Hold function: by keypress the current <strong>measuring</strong> value will be “frozen”<br />
Min/max-value memory: the min. and max. measured value is stored<br />
Power-Off-function: <strong>de</strong>vice turns off after some time (adjustable: 1-120 min or <strong>de</strong>activated),<br />
if no operating has taken<br />
The <strong>measuring</strong> cell<br />
The <strong>measuring</strong> head is <strong>de</strong>signed without compromise. The<br />
holes ensure the well exchange of the <strong>measuring</strong> fluid, nonetheless<br />
the sensor is protected against mechanical loads.<br />
The integrated temperature sensor has very quick response<br />
time. Compared to simpler electro<strong>de</strong> <strong>de</strong>signs the measurements<br />
are much more accurate and faster.<br />
GLF 100:<br />
Graphite used as material for the<br />
electro<strong>de</strong>s makes the applicability up<br />
to 100 mS/cm possible – a must have<br />
in seawater analytic<br />
GLF 100 RW:<br />
Universal applicability at highest<br />
standards is ma<strong>de</strong> possible by the use<br />
of stainless steel electro<strong>de</strong>s (1.4404,<br />
1.4435).<br />
Accessories<br />
GKL 100 <strong>Conductivity</strong> control solution<br />
(100 ml bottles with 1413 µS/cm. (acc. to DIN EN 27888))<br />
GKL 101 <strong>Conductivity</strong> control solution<br />
(250 ml bottles with 84 µS/cm.)<br />
GEH 1 Swivel-arm electro<strong>de</strong>-retainer<br />
(for up to 4 electro<strong>de</strong>s / probes )<br />
GWZ-01 Flow-through chamber<br />
(for <strong>measuring</strong> cell with Ø 12 mm)<br />
ST-KR Protection bag (for <strong>de</strong>vice)<br />
GB 9 V Spare battery 9V / approx. 300 mAh, type 6F22<br />
GKK 252 Case (235 x 185 x 48 mm) with punched lining<br />
GKK 3100 Case (275 x 229 x 83 mm) with punched lining<br />
N E U<br />
N E U<br />
N E U<br />
N E U<br />
for additional accessories please refer to page 40, 41<br />
33<br />
Transmitter<br />
Temperature probe<br />
Alarm / Protection