Determine the horizontal projected area needed<br />

1. Choose the specific loading rate. For example a standard<br />

loading rate is 0.3 gpm/ft 2 of effective plate area at 90%<br />

efficiency.<br />

Calculations for 10 MGD (6950 GPM) example:<br />

Divide the flow in gpm by the loading rate:<br />

Flow = 6,950 = 23,166 ft 2 = projected area<br />

the Loading rate .3 GPM/ft 2<br />

Apply the efficiency<br />

SIZING CALCULATION EXAMPLE<br />

2. Divide the projected area by the efficiency – 90%<br />

Projected area = 23,166 ft 2<br />

efficiency .9<br />

= 25,740 ft 2 effective area