Download - Watz Hydraulik GmbH
Download - Watz Hydraulik GmbH
Download - Watz Hydraulik GmbH
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Sollte hier auch was stehen?<br />
FAUDI for Andasol<br />
Protected solar power<br />
in Spain<br />
Andasol 1 to 3 are located in the Spanish province<br />
of Granada, with Andasol 3 still under construction.<br />
They are state-of-the-art solar-thermal power stations that,<br />
following completion, will consist of 510,000 square meters<br />
of collector surface - Europe‘s largest solar power station.<br />
The technically usable potential of solar-thermal electricity<br />
generation exceeds the worldwide demand for electricity<br />
many times over. Solar radiation heats up oil as a heat<br />
carrier to approximately 300 °C, which is then pumped to<br />
circulate through the system and transfer the energy. In this<br />
process, very fine particles develop, which are deposited<br />
on the insides of the piping and which can cause damage.<br />
To prevent this, candle filters with special stainless-steel<br />
backflush filter elements from FAUDI are used in Andasol 1<br />
and 2. The special design of these HTF filter elements means<br />
that, when the backflush valve in the lowest part of the filter<br />
is briefly opened, dirt is washed out of the filter elements<br />
and discharged from the system. This serves to protect the<br />
sensitive machinery from dirt and suspended particles in the<br />
optimum way. The filters achieve a filtration grade of up to 3<br />
μm. The newly developed gas-assisted backflushing process<br />
and the newly developed filter elements in the FAUDI candle<br />
filters also reduce flushing loss considerably. This protects<br />
the environment through less waste and also allows financial<br />
savings to be made due to lower amounts of expensive oils<br />
being lost. Besides Andasol, FAUDI candle filters are also<br />
used in Spain in the Extresol power stations 1 and 2.<br />
Technical Data<br />
Medium:<br />
heat carrier oil<br />
Design pressure: 18.5 bar<br />
Design temperature: 400 °C<br />
Flow volume: 150 m 3 /h<br />
Filtration grade: 20 μm<br />
10 | 11