download - EUROmodul international
download - EUROmodul international
download - EUROmodul international
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
CONTENT<br />
HEADQUARTERS<br />
4<br />
18<br />
24<br />
26<br />
28<br />
modular building system / technical data<br />
<br />
container system / technical data<br />
<br />
flat pack <br />
office / living / stirage<br />
<br />
sanitary / toilet <br />
Note<br />
<strong>EUROmodul</strong> Ltd<br />
Blazici 25<br />
51216 Viskovo<br />
Rijeka - Croatia<br />
tel: +385 51 257 275<br />
fax: +385 51 258 472<br />
info@euromodul.hr<br />
www.euromodul.hr<br />
Products<br />
38<br />
40<br />
42<br />
telecommunication<br />
technical<br />
complex<br />
<strong>EUROmodul</strong> is the leading manufacturer of street furniture,<br />
advertising equipment and containers in South East<br />
Europe and Russian Federation market.<br />
We received recognition for our dynamic development<br />
and success in business, as well as for advanced innovations.<br />
When concidering street furniture products, <strong>EUROmodul</strong> is one<br />
of the biggest production companies in Europe.<br />
Most of the products are mutually combined, therefore our<br />
catalogue is not divided in such matter.<br />
We produce standard products out of our product lines, but we<br />
are also capable of producing customised products according to<br />
individual requests<br />
(custom made).<br />
WHY ARE <strong>EUROmodul</strong> CONTAINERS BEST CHOICE FOR YOU<br />
FACTORYS / OFFICES<br />
<strong>EUROmodul</strong> is the leading street furniture, advertising equipment and containers manufacturer in South East Europe and<br />
the wide range of products put us among the world leaders. Our products can be found in the streets and city squares of<br />
many cities. We received recognition for our dynamic development and business success, as well as for advanced innovations<br />
from the World famous jury, REDDOT and iF product design awards!<br />
<strong>EUROmodul</strong> Ltd<br />
Industrijska zona bb<br />
22330 Nova Pazova<br />
Serbia<br />
tel: +381 22 328 003<br />
fax: +381 22 328 004<br />
info@euromodul.rs<br />
www.euromodul.rs<br />
Factory in Serbia<br />
u<br />
u<br />
Our knowledge and experience gained by annual production of up to 3.500<br />
containers and export to the EU, Russia, the Middle East countries and Africa.<br />
In production of containers we use the most advanced zinced steel and<br />
thermal-insulating material (polyurethane foam, mineral wool, IPN, etc.)<br />
and materials of the façade by specific requirements of investors.<br />
<strong>EUROmodul</strong> Schweiz AG<br />
Bergfeldstrasse 29<br />
3032 Hinterkappelen - Bern<br />
Switzerland<br />
tel: +41 31 901 05 80<br />
fax: +41 31 901 05 85<br />
www.euromodul.ch<br />
info@euromodul.ch<br />
Office / warehouse<br />
Switzerland<br />
u<br />
u<br />
u<br />
Our containers have broad range of usage, mostly in construction and housing.<br />
Office containers for construction sites or multi-year temporary facility/<br />
office container; housing single container or container housing settlements;<br />
kindergartens, schools, etc.; FLAT PACK containers for installation in remote<br />
locations; storage and warehouse containers; sanitary containers or public<br />
toilet facilities; ambulatory containers or permanent facilities clinics, health<br />
centers, etc.; kitchen containers for construction sites; specific containers for<br />
mobile or fixed telephony, radio links, transmitters, etc.; mobile containers for<br />
restaurants, fast food, bars, etc.<br />
<strong>EUROmodul</strong> container factory in Rijeka / Croatia is situated near sea port -<br />
harbour which is good logistic point for sea transport of different container<br />
types for World- wide destinations. Road transport in Rijeka is connecting<br />
West and South East Europe.<br />
<strong>EUROmodul</strong> Ltd<br />
Prva proleterska s-54<br />
33 000 Budva<br />
Montenegro<br />
RUSSMODULSTROY<br />
Vokzalnaja 1 „V“, 625530<br />
p.g.t. Vinzili, Tyumen region<br />
Russian Federation<br />
tel: +382 33 452 019<br />
fax: +382 67 238 768<br />
info@euromodul.me<br />
www.euromodul.me<br />
tel: +7 3452 727 500<br />
fax: +7 3452 761 934<br />
www.russmodulstroy.ru<br />
info@russmodulstroy.ru<br />
Office in Montenegro<br />
Factory in Russian Federation<br />
u<br />
<strong>EUROmodul</strong> container factory in Belgrade / Serbia have export advantages<br />
of containers to Russia and South East Europe.<br />
2<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 3
<strong>EUROmodul</strong> system from prefabricated objects<br />
<strong>EUROmodul</strong> at factories in Viškovo - Rijeka, Croatia and Nova Pazova, Serbia<br />
manufactures prefabricated buildings for residential or office uses.<br />
modular<br />
building<br />
system<br />
<strong>EUROmodul</strong> EUROSTANDARD<br />
container type<br />
systems from<br />
prefabricated<br />
objects<br />
container systems<br />
for modular constructions<br />
<strong>EUROmodul</strong><br />
STANDARD container type<br />
system of<br />
prefabricated<br />
facilities<br />
4<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 5
<strong>EUROmodul</strong><br />
MODULAR BUILDING SYSTEM<br />
modular buildings for offices, hollyday and permanent<br />
houses ( estates ), ambulatory facilities, kindergartens,<br />
schools, hospitals, industry, etc...<br />
What energy systems are built in <strong>EUROmodul</strong> modules or objects?<br />
Modular constructions are steel frame constructions, 3D factory produced module which is easily assembled on site based on<br />
module next to module, or module on top of the module principle. By simple connecting and binding, an object or a series of<br />
objects are created, which are standardly up to three floors in height. At special request of the customer objects of more than<br />
three floors can be designed.<br />
What are the advantages of <strong>EUROmodul</strong>’s modular designs?<br />
Modular constructions are generally accepted as a great solution in construction for its flexibility, low prices and especially<br />
great saving of time when planning and building the objects. Euromodul’s system of building with modular constructions<br />
is as good as the constructions developed in technologically developed countries. They are easily adjustable to almost<br />
every architectural issue that today many companies, industry and other institutions such as pre-schools, schools or health<br />
institutions are facing.<br />
<strong>EUROmodul</strong> creates blueprints of montage of modular object and building the foundations in collaboration with its clients.<br />
<strong>EUROmodul</strong> has a team of experts for sales and design which, together with clients finds perfect solutions for all their<br />
requests and needs.<br />
Which markets usually use modular systems?<br />
Modular systems are mostly used in industry, health care, school system, banks, transport, different types of institutions,<br />
sports centers, etc…<br />
Does <strong>EUROmodul</strong> deliver its object on “turn key”<br />
<strong>EUROmodul</strong> can ensure that all services in delivery and building and therefore “turnkey”<br />
Usually energy systems are built in into the modules in the factory. Those are electrical installations, plumbing, heating<br />
systems, including floor heating, smoke detectors, fire extinguishers as well as other functional and safety devices. There are<br />
also optional possibilities of building in solar systems for the production of electrical energy and heating of technical water.<br />
What are the dimensions of <strong>EUROmodul</strong> modular constructions and what are the dimensions of<br />
object that can be assembled from them?<br />
In standard production, 3D modules are of following dimensions:<br />
Lenght: – 3 m (smallest) Width: – 2,44 m (smallest)<br />
– 6,5 m (standard) – 3 m (standard)<br />
– 9 m (biggest) – 3,5 m (biggest)<br />
Exterior height: – 3 m (standard) Interior height: – 2,5 m (standard)<br />
– 3,5 m (biggest) – 3 m (biggest)<br />
The object created from <strong>EUROmodul</strong> modules can virtually have unlimited length and width dimensions.<br />
The standard height of 3 floor objects is approximately 9m without the additional (secondary) roof.<br />
Do <strong>EUROmodul</strong> objects fit the regulation requirements?<br />
<strong>EUROmodul</strong> constructions are designed and assembled in such way that they meet local and state regulations which are in<br />
force at the time of construction and assemblage.<br />
What are the posibilities when it comes to the exterior desing-facade?<br />
Almost all types of modern materials and facades that are today available on the market can be built in every Euromodul<br />
modular unit or object, either in factory production or during assemblage on site. There is an option of building in<br />
prefabricated elements such as HPL, steel sheets or traditional materials such as brick, stone or plaster. It is possible to create<br />
different styles of roof. An object can be of standard design and partly or completely designed by a client.<br />
Are there any limitations on modular construction?<br />
There are some limitations in designing objects. The main limit is in the limited height of<br />
the module, which is being transported to the site as a 3D module, so the height of the<br />
module has to be 2,5m or 3m if it is transported with special vehicles. This limitation can<br />
be solved by transporting modules in a pack, the so-called flat pack, which creates some<br />
added assemblage costs but also lowers the transport costs. In any case we calculate cost<br />
effectiveness.<br />
What Is The Utilizeable Width Of <strong>EUROmodul</strong> Modular Constructions?<br />
The standard widths are of 6,5m and 9m when using steel constructions. Bigger widths can<br />
be creates using additional steel beams which connect the roof and floor of the modules.<br />
Bigger widths can be created also by using braced girder, which depends on the number of<br />
floors the object has.<br />
How are the interior of <strong>EUROmodul</strong> modular objects designed?<br />
There is a possibility of creativity in the process of designing the interior when it comes to<br />
the dimensional shape, as well as choosing any kind of built-in covering materials available<br />
on the market. Standardly, as a finishing cover on walls and pillars, we use plaster board<br />
panels in any color the client desires. As a finishing floor cover we standardly use PVC<br />
covers of standard design.<br />
6<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 7
<strong>EUROmodul</strong> PREMIUM - Energy efficient estates<br />
specification of modular building system -<br />
FACADE TYPE A assembly in factory<br />
Structure - elements Standard Optional<br />
Foundation<br />
Concrete: plate, strip foundation, single foundation, combinations of types<br />
Floors OSB plates, PVC dressing cement board, cheramic for ‚wet‘ spaces<br />
Walls - from exteriour<br />
zinced and plastificated plate, low corrugation<br />
or casetts<br />
precious plasters, facade bricks,<br />
cement boards, HPL<br />
Walls - from interiour<br />
and internal walls<br />
gypsum boards, painted<br />
cheramic tiles, zinced plasticated plate<br />
Roof zinced plastificated plate tile, imitarion of tiles (hip roof)<br />
Ceiling gypsum boards, painted enriched chipboard, lowered ceiling, various fillings<br />
Windows PVC with triple glass, U=0,86 aluminium, wood<br />
Exteriour door aluminium with termical insulation U=0,86 PVC with termical insulation U=0,86<br />
Inner door aluminium wood<br />
Electric installations according EU norms on request<br />
Sanitary installations masched instalaltions, plastic tubes on request<br />
Lenght 3.0, 6.5 and 9.0 m<br />
on request<br />
Dimensions<br />
in 3D modules<br />
Thermic insulation<br />
(schematic)<br />
width: 2.44 and 3.0 m<br />
inner height 2.5 m<br />
exterior height 3.0 m<br />
gypsum board + plate<br />
up to 3.5 m<br />
up to 3.0 m<br />
up to 3.5 m<br />
FACADE TYPE B assembly on location<br />
connections between moudles<br />
dressing - facade assembled in factory<br />
dressing can be standardly profiled plate, optionally<br />
casetts, HPL laminate, putz facade, noble plasters<br />
plasterboard dressed modules in factory<br />
as base for final facade dressing<br />
mineral wool width 200 mm U=0,167 W/m2K<br />
mineral wool width 230 mm U=0,146 W/m2K<br />
dressing - facade assembled on location<br />
Fire Protection Class:<br />
gypsum board<br />
dressing can be standardly profiled plate,<br />
optionally casetts, HPL laminate, putz facade<br />
Mineral wool: Class A2 - s1, d0<br />
PIR pannel: Class B - s2, d0<br />
triple glass U=0,86 W/m2K<br />
With this kind of specifications<br />
on thermal insulation,<br />
we call our structures as<br />
<strong>EUROmodul</strong><br />
efficient isolation<br />
gypsum board<br />
gypsum board + plate<br />
mineral wool width 200 mm U=0,167 W/m2K<br />
mineral wool width 230 mm U=0,146 W/m2K<br />
FACADE TYPE C assembly in factory<br />
construction that can be seen<br />
connections between moudles<br />
OPTIONALLY:<br />
PUR or PIR pannel width 120 mm U=0,18 W/m2K<br />
PUR or PIR pannel width 150 mm U=0,15 W/m2K<br />
dressing - facade assembled in factory<br />
mineral wool panels + PVC 40 mm<br />
mineral wool width 150 mm U=0,205 W/m2K<br />
dressing standardly profiled plate,<br />
optionally casetts, HPL laminate<br />
8<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 9
first floor<br />
Are objects assembled according to the standards of a certain country which regulates<br />
the consumption of heating energy?<br />
Considering that the modules are primarily designed for Swiss market, Euromodul optionally uses standard SIA 38011-2009,<br />
which prescribes energy consumption for heating during a year to be up to 48 Kwh/m of the space.<br />
This standard is achieved by using certain isolations whereat the heat coefficient U
modular buildings for offices, hollyday and permanent houses ( estates ), ambulatory facilities, kindergartens, schools, hospitals, industry, etc...<br />
Foundations<br />
The foundations are created according to the designs and are built as a<br />
concrete board or strip foundations depending on whether the object is<br />
temporary.<br />
Module flooring<br />
It consists of steel bearer frame with alternating steel and wood ribs,<br />
below which there is coated zinced steel, and in between the steel ribs<br />
there is mineral wool. Above the steel ribs there is added isolation and<br />
OSB panel 30mm thick with PVC coating in a standard design. In wet<br />
areas there is a cement water-proof chipboard and ceramics in standard<br />
design.<br />
ground floor<br />
p<br />
Business offices<br />
first floor<br />
second floor<br />
Exterior walls<br />
Exterior walls consist of two parts:<br />
The outer part of the walls is mostly decorative-façade that is set onto the module in the factory more often on site of a<br />
previously built object (created from modules). So for example if the object has 3 floors around 9m in height, the façade<br />
elements are 9m panels and cover the whole height of object with one panel. Standardly Euromodul delivers or builds in<br />
decorative ‘sandwich panels’ of 50mm thickness consisting of tin-mineral wool-tin or tin-polyurethane-tin, which are more<br />
humidity-proof and are far better isolators (thermal conductivity for a panel 50 of mineral wool is 0,75 and for polyurethane<br />
panel is 0,41). Optionally, Euromodul builds in or coats objects with aluminum profiles, steel zinc cassettes, façade isolation<br />
systems, brick, wooden sheeting, and glass. As decoration-functional elements of facade there can be, according to the wish of<br />
the client, added canopy, porch…<br />
12<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 13
Matching the modules, or object to<br />
the different climates.<br />
The design of the modules is of the ‘open<br />
type ‘which provides building in different<br />
types of insolation materials in accordance<br />
with the physical characteristics of the object.<br />
To the standard constructions there can be<br />
added steel elements which provide better<br />
stability of the objects.<br />
Modules and objects can be adapted so<br />
they can be used even in extremely cold<br />
conditions and high latitude, and also for<br />
mild and tropical climates. The standard<br />
construction of Euromodul modules is<br />
designed for mild climate but the quality of<br />
insolation is in accordance to the energy<br />
efficient objects.<br />
Doors and windows<br />
Standardly Euromodul build in PVC or<br />
aluminum doors and windows. Optionally<br />
there can be windows and balcony doors<br />
built in with two chamber glass filled with gas.<br />
Thermal resistance is W/m/C.<br />
p<br />
EFH 3<br />
9,0 x 6,0 m<br />
Initerior walls and interior party walls<br />
The structure and thickness of the walls can be<br />
changed according to climate of the place where<br />
the object is going to be and depends on the<br />
regulations in certain countries and according to<br />
the wish of the client.<br />
As inner part of exterior walls and inner part walls<br />
Euromodul builds in polyurethane panels or mineral<br />
wool panels, standardly panels are coated with<br />
plaster boards and colored according to the wish<br />
of the client. If needed, inside the walls there can<br />
be steel structures or wooden structures built in as<br />
a bearer element. Angular pillars of modules are<br />
included in isolation of walls so the heat bridges<br />
are terminated.<br />
p<br />
EFH 1<br />
9,0 x 3,0 m<br />
p<br />
EFH 2<br />
9,0 x 3,0 m<br />
Roof<br />
It consist of steel bearer frame with built in<br />
small wooden beams with replace steel profiles<br />
so they cancel heat bridges. The frame with ribs<br />
is filled out with mineral foam, from the bottom<br />
the frame is closed standardly with panels<br />
made of plaster-cardboard board which is the<br />
ceiling, and from the top bended galvanized<br />
steel sheet.<br />
At the edge of the roof there is a cut from<br />
which the water is distributed to all sides of the<br />
module. Accordingly to the wished of the client<br />
as an addition to these flat roofs there can be<br />
secondary tilted roofs added, they can also be<br />
two-sloped or four-sloped accordingly to the<br />
shape of the object. As a covering of the roof<br />
we use roof tile or imitation of it and profilsied<br />
and powdercoated steel sheets.<br />
14<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 15
p<br />
Kindergarden ‚Magic Forrest‘ in Belgrade<br />
Installations<br />
All installations are mostly built in the modules during the manufacturing process in the factory. On the site, during the<br />
assemblage the previously prepared installations are just connected. Sometimes, the installations are partially prepared on<br />
the site. Electrical installations are created in accordance with the regulations. Plumbing (pipes and elements) is made of<br />
PVC. For each model it is necessary to create a technical design.<br />
Transportation<br />
<strong>EUROmodul</strong> system of the standard modules (length up to 9m, width 2,438m and height 2,950m) provides transportation<br />
without additional escort, by trucks and train. Modules of the above dimensions can be transported in covered trucks<br />
and also in opened trucks in which case the modules are’ packed’. If the modules exceed stated dimensions, for their<br />
transportation special vehicles are needed. For long<br />
distances (over 1000km) it is recommended for modules to<br />
be packed in the ‘flat-packs’ which provides the transport of<br />
3-4 modules instead of just one.<br />
Assemblage on site<br />
<strong>EUROmodul</strong> prepares designs for the foundations and<br />
insolation, plumbing and sewage installations. In most cases<br />
the foundations are prepared by the local construction<br />
company. Assemblage is done based on the montage project.<br />
If the assemblage is handled by a local construction company,<br />
Euromodul provides help and technical assistant.<br />
p<br />
Kindergarden - school<br />
1. classroom - playroom<br />
2. multipurpose hall<br />
3. toilets<br />
4. hall<br />
5. offices<br />
6. dressroom<br />
16<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 17
CONTAINER SYSTEMS<br />
FOR MODULAR CONSTRUCTIONS<br />
Elements of the system<br />
Elements of modular building structures are an expression of the serial factory production systems of mainly STANDARD<br />
components - elements that are combined - by composing solutions or a combination of compiling the individual container<br />
modules as a higher degree of modular construction units, or complete products for the market.<br />
roof<br />
wall<br />
elements<br />
EUROSTANDARD<br />
STANDARD<br />
pillars<br />
floor<br />
door<br />
sanitar window<br />
double window<br />
for air condition<br />
door with window<br />
ISO standard dimensions 20‘‘ optionally 10‘‘ up to 30‘‘<br />
lenght = 6.058 mm (optionally 3.048 - 9.100 mm)<br />
width = 2.438 mm (optionally 3.000 mm)<br />
exterior height = 2.591 mm (optionally 2.791 mm or 3100 mm)<br />
inner height = 2.300 mm (optionally 2.500 mm or 2800 mm)<br />
ELEMENTS<br />
OF THE<br />
SYSTEM<br />
full<br />
window<br />
Construction<br />
ZINCED metal profyles 3 mm welded<br />
Container construction<br />
colour RAL 3002 (red)<br />
option: on customer wish in RAL colour<br />
ZINCED metal profyles 3 mm connected<br />
with screws<br />
non painted<br />
option: painted on customer wish in RAL colour<br />
Floor<br />
FLAT PACK<br />
INDEPENDED<br />
INDIVIDUAL MODUL<br />
option:<br />
1.5 mm VINYL DRESSING<br />
19 mm OSB board<br />
PU PANEL 50 mm<br />
RIB<br />
LAMINATE OR CHERAMIC TILES<br />
PU PANEL 50 mm<br />
RIB<br />
Floor openings for forklift<br />
With forklift pockets<br />
(for containers up to 7.335 mm,<br />
holes distance1.506 mm)<br />
Without forklift pockets<br />
option: With forklift pockets<br />
(for containers up to 7.335 mm,<br />
holes distance1.506 mm)<br />
Roof<br />
Group system<br />
of modular<br />
construction<br />
container facility<br />
on location<br />
option:<br />
0.63 mm ZINCED STEEL PLATE<br />
100 mm MINERAL WOOL<br />
STEEL 40 x 80 mm<br />
PVC foil vapour barrier<br />
Enriched white chipboard10 mm<br />
ZINCED STEEL PLATE COVER 0,6 mm<br />
100 mm MINERAL WOOL<br />
STEEL 40 x 80 mm<br />
PVC foil vapour barrier<br />
Enriched white chipboard 10 mm<br />
50 + 40 mm PU PANEL<br />
18<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 19
EUROSTANDARD<br />
STANDARD<br />
EUROSTANDARD<br />
STANDARD<br />
Exteriour wall and side panels<br />
60 mm poliurethane panel, 50 mm poliurethane panel,<br />
externally microcorrugated RAL 9002 externally microcorrugated RAL 9002<br />
internally smooth RAL 9010 (white)<br />
internally smooth RAL 9010 (white)<br />
option: 60 mm mineral wool, bothside plasticated in RAL 9002<br />
option : 60 mm mineral wool, exteriour side plasticated in RAL 9002,<br />
internally enriched chipboard 100 WHITE010 (white)<br />
Windows and doors<br />
PVC, windows with shutters<br />
optionally: windows without shutters<br />
PVC without shutters<br />
optionally: windows with shutters<br />
Exteriour and inner doors<br />
PVC with polyurethane filling 40 mm, clear opening 79/202 cm<br />
Isolation, coefficient of thermal resistance<br />
Floor = U = 0,32 W / m 2 K Floor = U = 0,37 W / m 2 K<br />
Roof = U = 0,37 W / m 2 K Roof = U = 0,39 W / m 2 K<br />
Wall panels = U = 0,41 W / m 2 K Wall panels = U = 0,41 W / m 2 K<br />
Window = U = 2,40 W / m 2 K Window = U = 2,40 W / m 2 K<br />
EUROSTANDARD<br />
container type<br />
with zinced and painted construction<br />
(blue coloured pannels as option)<br />
exteriour power connections inside roof construction,<br />
one door two windows with shutters<br />
forklift openings<br />
STANDARD<br />
container type<br />
with zinced construction<br />
one door two windows<br />
p<br />
p<br />
20<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 21
Tehnical features of container modules<br />
Location preparation<br />
EUROSTANDARD<br />
STANDARD<br />
for one container:<br />
for 2, 4 and more containers<br />
Dimensions (mm) and weights (kg)<br />
external internal (starting) weight<br />
type lenght width height** lenght width height assembled FLAT PACK<br />
assembled<br />
FLAT PACK<br />
10‘ 2,990 2,438 2,600 650 - 700 2,760 2,200 2,300 1,315 1,377<br />
16‘ 4,885 2,438 2,600 650 - 700 4,650 2,200 2,300 1,725 1,785<br />
6.060 mm<br />
2.440 mm<br />
6.060 mm 6.060 mm<br />
2.440 mm 2.440 mm<br />
20‘ 6,058 2,438 2,600 650 - 700 5,830 2,200 2,300 1,970 2,030<br />
*24‘ 7,355 2,438 2,600 650 - 700 7,125 2,200 2,300 2,295 2,357<br />
*30‘ 9,120 2,438 2,600 650 - 700 8,890 2,200 2,300 2,765 2,825<br />
Handling and lifting<br />
By fork: angle between roof and cable must be at last 60 o<br />
* as option<br />
**optionally also available with an external height of 2,800 mm / internal height 2,500 mm / FLAT PACK height 900 mm<br />
option:<br />
Forklift for lifting containers up to 7.3 m in lenght if container has forklift holes<br />
Group system<br />
of modular<br />
construction<br />
container facility<br />
on location<br />
Electric installations<br />
Volt 230/400V, 50 Hz, 3/5 pole, 32A,<br />
FID socket 40/0.03A, fuses 16 A i 10 A<br />
Two sockets, two fluo tubes 2 x 58W<br />
Grounding on location is made by customer, with zinced cable<br />
on container and adequate holders - plates<br />
Installation inspection and grounding must be done by authorised people<br />
Electrical heater 2 kW<br />
CEE sockets in roof construction with cable connection<br />
On-wall sockets<br />
SOCKET<br />
SOCKET<br />
SOCKET<br />
option: sockets in construction<br />
electric installations are inside panels<br />
electric installations are inside plastic covers<br />
option: Ventilation to ensure relative humidity up to 60% on 20 o C<br />
in order to avoid condensation<br />
option: Air condition / heating or only air condition<br />
Load<br />
Floor = 250 kg / m 2<br />
Roof = 200 kg / m 2<br />
Side (wind) = 90 kg / m 2 in case of side wind object fixcation on the ground<br />
22<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 23
FLAT PACK<br />
CONTAINERS<br />
Flat Pack containers are used as:<br />
OFFICE, LIVING, STORAGE<br />
FLAT PACK<br />
Lifting by crane one by one, possible also with forklift with adequate construction<br />
if container doesn‘t have forklift holes<br />
Truck can handle up to 4 (or 8) containers in FLAT PACK.<br />
FLAT PACK<br />
container<br />
p<br />
p<br />
roof lifting<br />
Each unit is 650 mm in height if wall panels are up to 100 mm<br />
Each unit is 700 mm in height if container has also inner walls and doors<br />
(another room)<br />
FLAT PACK containers<br />
Containers that are intended for use<br />
in distant locations are FLAT PACK<br />
containers in reduced transport<br />
dimensions.<br />
STANDARD<br />
= 2 CONTAINERS<br />
When compared to standard containers,<br />
FLAT PACK offer up to 4 times<br />
less transport space.<br />
The time for mountage on location<br />
(two persons ) is pproximately<br />
45 minutes.<br />
FLAT PACK<br />
= 8 CONTAINERS<br />
video:<br />
p<br />
pillar tightening<br />
wall<br />
mounting<br />
p<br />
p<br />
containers as<br />
FLAT PACK<br />
CONTAINERS<br />
prepaired for shipping<br />
in reduced size<br />
<strong>EUROmodul</strong><br />
FLAT PACK container<br />
fully assembled<br />
p<br />
Individual modules as<br />
FLAT - PACK (packed container)<br />
come on the market where<br />
they are used as independent,<br />
individual or they are part of<br />
a system of modular building<br />
structures.<br />
24<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 25
OFFICE<br />
CONTAINERS<br />
containers can be used other than just for<br />
OFFICE, LIVING, STORAGE<br />
also as mobile sale points, sail offices, they can be<br />
combined with toilets, etc.<br />
All the layouts can be individually modified.<br />
p 1147<br />
storage, 3,0 x 2,4 m<br />
thermoisolated, door, finished el.<br />
cables, fuses, socket, ceiling light,<br />
PVC floor<br />
p<br />
1148 office- storage container 6,0 x 2,4 m<br />
thermoisolated, door, finished el. cables,<br />
fuses, sockets, 2 ceiling lights,<br />
PVC floor<br />
p 1141<br />
office,<br />
6,0 x 2,4 m,<br />
in two spaces and lobby,<br />
3 doors, 2 windows, thermoisolated,<br />
PVC floor, finished el. cables, fuses,<br />
5 sockets, 3 ceiling lights<br />
p 1157<br />
office,<br />
6,0 x 2,4 m,<br />
in two spaces and lobby with toilet<br />
and shower, 4 doors, 3 windows, thermoisolated,<br />
PVC floor, finished el. cables, fuses, 5 socket,<br />
3 ceiling lights<br />
container as sale<br />
fashion shop<br />
p p<br />
12,0 x 2,4 m<br />
p<br />
1103 office / living container<br />
with lobby, two doors, two windows,<br />
thermoisolated, finished el. cables, fuses,<br />
three ceiling lights, two sockets, PVC floor,<br />
without inner equipment<br />
p<br />
1106 office container 6,0 x 2,4 m<br />
with lobby and equipped toilet and shower,<br />
two doors, three windows, thermoisolated,<br />
finished el. cables, fuses, two ceiling lights,<br />
two sockets, PVC floor<br />
26<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 27
SANITARY<br />
CONTAINERS<br />
Sanitary containers are made and delivered with<br />
functional equipment. Frequently, sanitary containers<br />
can be combined with offices or made as separate<br />
objects.<br />
Sanitary objects are usually not delviered as<br />
FLAT PACKS as they have equipment and installations<br />
inside which can hardly be reduced and therefore it‘s<br />
delivered as finished objects<br />
p<br />
hand washbasin in kerok<br />
with mirrors, soap<br />
dispensers, hand dryers<br />
etc.<br />
p<br />
1196<br />
sanitary,<br />
1,2 x 1,4 m<br />
thermoisolated,<br />
WC cabin, wash<br />
basin, PVC floor<br />
p<br />
1171<br />
sanitary<br />
container<br />
1,2 x 2,4 m<br />
p<br />
1171<br />
sanitary,<br />
1,2 x 2,4 m<br />
thermoisolated,<br />
WC cabin, wash<br />
basin, pissoir,<br />
2 doors,<br />
PVC floor<br />
p<br />
1197<br />
sanitary,<br />
2,4 x 1,4 m<br />
thermoisolated, toilet<br />
bowl, wash basin,<br />
boiler, shower,<br />
PVC floor<br />
p<br />
1195 sanitary container<br />
dimensions 6,0 x 2,4 m,<br />
thermoisolated, two doors,<br />
4 shower cabins, boiler,<br />
2 washing basins, ceiling lights,<br />
PVC floor<br />
interior toilet container<br />
with urinals and<br />
washbasins<br />
p<br />
28<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 29
p<br />
1108 sanitary container<br />
equipped with 2 WC cabins, 5 wash<br />
basins, 2 pissoirs, boiler, 2 showers,<br />
4 windows, thermoisolated<br />
p<br />
1107<br />
sanitary container 6,0 x 2,4 m<br />
in two spaces: all together 5 WC cabins,<br />
4 wash basins, 2 pissoirs one boiler, tiles<br />
floor, thermoisolated<br />
p<br />
1191 sanitary container 6,0 x 2,4 m,<br />
thermoisolated, 2 toilet cabins, 3 wash<br />
basins, 2 pissoirs, 2 WC cabins,<br />
PVC floor<br />
p<br />
1192 sanitary<br />
container 6,0 x 2,4 m,<br />
thermoisolated, 2 wash<br />
basins, 3 pissoirs, 4 WC<br />
cabins, PVC floor<br />
p<br />
p<br />
1194 sanitary container 6,0 x 2,4 m<br />
thermoisolated, in two (M / F), each space<br />
with one wash basins, 2 pissoirs, 2 WC<br />
cabins, ceiling lights, PVC floor<br />
1193 sanitary<br />
container 3,0 x 2,4 m,<br />
thermoisolated, two<br />
wash basins, pissoir,<br />
WC cabin, shower cabin<br />
ceiling lights,<br />
PVC floor<br />
p<br />
toilet bowl with stainless steel<br />
handrails for disabled persons<br />
p<br />
1173<br />
sanitary, 1,8 x 2,4 m<br />
thermoisolated,<br />
WC cabin for<br />
disabled, wash<br />
basin, PVC floor<br />
<strong>EUROmodul</strong> is suppling sewage tanks<br />
for the case where there are no sewage<br />
city mesh connection and tank-water<br />
where is no possible connection city<br />
water mesh.<br />
These tanks are placed outside the<br />
building sanitary facilities or integrated<br />
into the facility foundation.<br />
p<br />
30<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 31
p<br />
Classic public toilet with wood<br />
facade and roof appropriate<br />
for areas such as mountains or<br />
areas with lots of snow<br />
p<br />
Public toilet with ventilated<br />
facade (30 years manufacture<br />
warrenty) with elements<br />
of natural stone in various<br />
colours.<br />
Toilet has large transparent<br />
sliding surfaces for daylight<br />
and ventilation.<br />
32<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 33
CONTAINER toilets can be in use of<br />
public or proprietary, but almost used<br />
especially in labor camps, construction<br />
sites, sometimes in tourist camps on the<br />
beaches, the sports events ..<br />
The shape and dimensions are similar to<br />
the shipping containers and when they<br />
are intended as a public toilet facilities<br />
<strong>EUROmodul</strong> enrich the colors, structural<br />
elements such as ATTIC to container<br />
moduls.<br />
p<br />
Sanitary container toilet<br />
with a roof attic<br />
p<br />
Container toilet with three user-space covered with<br />
wooden laths and overhangs wooden beams<br />
Park Bundek, Zagreb, Croatia<br />
p<br />
inner user space of toilet container.<br />
On walls installation of water and electricity<br />
p<br />
Container toilet with shower<br />
(as part of a larger object)<br />
34<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 35
Design and engineering<br />
In the design of container <strong>EUROmodul</strong><br />
sanitation / toilet regulations are<br />
applicable in the field of construction,<br />
provided the proper strength, thermal<br />
and sound insulation, construction is<br />
galvanised.It is possible to change the<br />
dimensions, arrangement of space,<br />
quantity and location of openings in walls<br />
and transport in packs for large transport<br />
distances.<br />
Production of housing containers and<br />
sanitary containers <strong>EUROmodul</strong> has<br />
developed a modular system.<br />
CONTAINER sanitary<br />
shall be fitted with conventional ceramic<br />
accessories: toilet bowls, wash basins,<br />
urinals ..<br />
At the request of the customer<br />
<strong>EUROmodul</strong> uses stainless steel<br />
equipment, including some automated<br />
module. A detailed overview of<br />
equipment is given in the table on page<br />
211 and 212.<br />
p Container toilet / showers<br />
in red color<br />
p<br />
pisoirs and toilets cabins<br />
containers with rubber floor<br />
p<br />
showers in container with rubber floor<br />
p<br />
Container toilet additionally equiped<br />
with stainless steel walls, ceramic tiles,<br />
disabled persons hand rails, ceramic tiles,<br />
Water and electricity installations are<br />
hidden behind walls<br />
p<br />
Basic container toilet with zinced powder<br />
coated walls in RAL 9010 basic ceramic<br />
tiles option with visible on wall installation<br />
of water and electricity<br />
36<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 37
TELECOMUNICATION<br />
CONTAINERS<br />
p<br />
3D view container<br />
inner equipment<br />
Containers for GSM equipment with secontary roof,<br />
zinced construction, painted, or in stainless steel on<br />
request<br />
Previously described technical description of<br />
container systems is also applicable to special<br />
containers - telephone, television and radio signal<br />
operating units.<br />
GSM container<br />
with antenna<br />
p<br />
Differencies can be found in waterproof isolation<br />
materials, better floor load capability, different<br />
installations etc.<br />
p<br />
stainless steel<br />
container with<br />
shelter<br />
weatherproof<br />
cable inlets<br />
p<br />
container 4603 02<br />
dimensions 2,4 x 2,4 m<br />
stainless steel<br />
construction with<br />
secundary roof<br />
p<br />
38<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 39
| container systems<br />
TECHNICAL<br />
CONTAINERS<br />
Technical containers are produced for special<br />
purposes as for compressors, pumps, or any<br />
other type of equipment that needs adequate<br />
protection etc.<br />
They are designed for the necessary statics, for<br />
the weight needed to carry, isolation, ventilation,<br />
power supply etc.<br />
p<br />
compressor<br />
inside container<br />
p<br />
container 4604 10<br />
truck transport<br />
p<br />
container 4604 20<br />
12,4 x 3,0 height 3,0 m<br />
for Caterpillar aggregate<br />
container manipulation<br />
and handling detail<br />
40<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 41
CONTAINERS<br />
COMPLEX<br />
FACILITIES assembled on location of individual container modules<br />
and related wiring and decorative elements are the highest level<br />
of <strong>EUROmodul</strong> system of modular construction.<br />
REFERENCE objects build with modular container system<br />
Office container complex<br />
in Switzerland, red painted<br />
containers<br />
p<br />
<strong>EUROmodul</strong> is specialized in manufacturing individual complex of<br />
containers / modular buildings. Containers / modules are assembled<br />
in SERIAL factory production from SERIAL manufactured elements.<br />
They come to the market as finished product as residential or office,<br />
sanitary / toilet, storage space equipped with or without equipment.<br />
Complex of containers / modular buildings its system usually used<br />
for building as kindergartens, schools, clinics, offices, sports, tourism<br />
and work camps with all necessary facilities: accommodation spaces,<br />
bathrooms, playrooms, kitchens and restaurants up to churches.<br />
The facilities built with <strong>EUROmodul</strong> construction system provide a<br />
very high standard of work or living. <strong>EUROmodul</strong> in cooperation with<br />
the investors, designs buildings, products, installation of container<br />
modules, builds facilities and provides a complete service to investors<br />
up to finish. <strong>EUROmodul</strong> supply facilities and coordinates with<br />
other projects, deliver modules or elements, regardless of who delivers<br />
or mounts them. <strong>EUROmodul</strong> has designed, manufactured and<br />
delivered some 25,000 prefabricated buildings for various purposes.<br />
<strong>EUROmodul</strong> has designed,<br />
manufactured and delivered some<br />
16,000 prefabricated buildings for<br />
various purposes.<br />
connection of 33 containers in<br />
unique complex 570 m2<br />
on border crossing<br />
42<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 43
This system is usually used for building kindergartens,<br />
schools, clinics, offices, sports, tourism and labor<br />
camps with all necessary facilities: accommodation<br />
spaces, bathrooms, playrooms, kitchens and<br />
restaurants up to churches.<br />
The facilities built with <strong>EUROmodul</strong> construction<br />
system provide a very high standard of work or living.<br />
44<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 45
containers in factory<br />
as offices p<br />
p<br />
containers dressed<br />
with wood facade<br />
in ski resort<br />
46<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 47
p<br />
container buildings<br />
as one complex<br />
in Austria<br />
p<br />
container<br />
manufacture<br />
container complex<br />
p<br />
three mutually gathered<br />
containers in Germany<br />
48<br />
unique prefabricated interior „Holcim“<br />
700 m2 made from 6 and 9 m containers, p<br />
standard width 2,4 m without columns<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 49
p<br />
container interior<br />
STANDARD<br />
<strong>EUROmodul</strong> MODULES<br />
is possible to mount up to<br />
three storeys.<br />
Optionally, we can buildt<br />
up to 5 storeys in height.<br />
p<br />
office space for logistic made<br />
from 4 containers (2 + 2 floors)<br />
in distribution centre<br />
50<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 51
p<br />
unique prefabricated interior „Holcim“<br />
700 m2 made from 6 and 9 m containers,<br />
standard width 2,4 m without columns<br />
52<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 53
Living - office containers<br />
We produce and install ofices,<br />
workshops, doorsrnice, toll,<br />
bedrooms, toilets, dressing rooms,<br />
dining rooms, shops, clinics, premises<br />
for the entertainment<br />
and pleasure<br />
54<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 55
containers as<br />
FLAT PACK CONTAINER<br />
(reduced transport dimensions)<br />
for Lybia<br />
p<br />
p<br />
container interior<br />
urinals and<br />
wash basins<br />
part of border crossing<br />
facility ‚Presevo‘ during<br />
manufacture<br />
56<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 57
order crossing<br />
Mali Zvornik between Srbija<br />
and Bosna and Hercegovina<br />
p<br />
p<br />
border crossing<br />
„Presevo“ between<br />
Serbia and<br />
Montenegro<br />
p<br />
FLAT PACK containers<br />
ready for shipping<br />
in ship containers<br />
(flat rack) for distant<br />
locations<br />
containers assembly on<br />
location in Russian Syberia<br />
p<br />
custom made container<br />
for water purification in<br />
Podgorica, Montenegro<br />
p<br />
58<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 59
<strong>EUROmodul</strong> system of<br />
PREFABRICATED FACILITIES<br />
60<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 61
Dormitory<br />
3,6 m 1,5 m 3,6 m<br />
8,7 m<br />
2,5m 2,5m 2,5m 2,5m 2,5m 2,5m 2,5m 2,5m 2,5m<br />
22,5 m<br />
7,33 m<br />
14,4 m<br />
House<br />
1,8 m 2,7 m<br />
4,5 m<br />
9,0 m<br />
2,4 m<br />
9,150 m<br />
7,2 m 5,4 m<br />
12,6 m<br />
62<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472<br />
info@euromodul.org | www.euromodul.org | 63
Folding object 1<br />
Transport is made in folded state with<br />
the size of a 20‘container. Two workers<br />
on location folds one side for an extra<br />
room or a total of 27m2 or both sides<br />
as two additional rooms in total approx.<br />
40 m2. In the middle space it‘s possible<br />
to transport furniture or restroom cabin.<br />
2<br />
3<br />
Folding is made in one hour time<br />
whith use of two workers.<br />
4<br />
5<br />
Materials and insatallations as<br />
standard <strong>EUROmodul</strong><br />
container module.<br />
64<br />
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472