8 Chapter 2: WFC3 <strong>Instrument</strong> Description<br />

Teledyne (<strong>for</strong>merly Rockwell Scientific) HgCdTe detector array, with the central<br />

1014×1014 pixels useful <strong>for</strong> imaging, and covering the near-infrared between 800 and<br />

1700 nm.<br />

The primary characteristics of the two channels are summarized in Table 2.1.<br />

Table 2.1: Characteristics of the two WFC3 channels.<br />

Channel<br />

f-ratio<br />

Detector<br />

type<br />

Spectral<br />

range (nm)<br />

Detector<br />

pixel <strong>for</strong>mat<br />

Pixel scale<br />

(arcsec)<br />

<strong>Field</strong> of view<br />

(arcsec)<br />

UVIS 31 CCD 200-1000 2×2051×4096 0.0395×0.0395 162×162<br />

IR 11 HgCdTe 800-1700 1014×1014 0.135×0.121 136×123