08.11.2014 Views

Product Range VKF-i - LK Systems AB

Product Range VKF-i - LK Systems AB

Product Range VKF-i - LK Systems AB

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Produktsortiment |<br />

Manifold <strong>VKF</strong>-i<br />

<strong>LK</strong> Manifold <strong>VKF</strong>-i<br />

Manifold of brass with integrated balancing lock shield valves and flow indicators<br />

0,5-5 l/min.<br />

The manifold can be delivered in sizes from 2 - 12 heating loops.<br />

Connection to the main circuit is possible from either left- or right hand side. Installation<br />

depth incl. bracket - 105 mm, c/c manifold 210 mm, c/c connection pipes<br />

50 mm.<br />

The manifold must be completed with:<br />

• <strong>LK</strong> Connection Coupling for pipe dim: PE-X/ PAL dim 16 x 2 (art. no. 241 74 61)<br />

/ PE-X dim 12 x 2 (art. no. 241 74 62) / PE-X dim 20 x 2 (art. no. 241 79 06) and<br />

2 ball valves 1” (art. no. 241 75 50).<br />

<strong>LK</strong> Connection Coupling for PE-X pipe 20 x 2,8 and copper pipe 12 x 1,0 and<br />

15 x 1,0 are available as accessories.<br />

Delivered in a box containing:<br />

• 2 manifolds assembled with fixing bracket.<br />

• 2 x end caps with manual vent, filler and drain plug, balancing key, assembly<br />

instruction, marking plates and protective bag.<br />

The measurments of the manifold are given incl. the end cap. When mounting<br />

<strong>LK</strong> Ball Valve 1” add approx. 55 mm.<br />

Article no. Loops Length Weight Package<br />

241 94 72 2 150 mm 1,8 kg 1<br />

241 94 73 3 200 mm 2,7 kg 1<br />

241 94 74 4 250 mm 3,5 kg 1<br />

241 94 75 5 300 mm 4,3 kg 1<br />

241 94 76 6 350 mm 5,1 kg 1<br />

241 94 77 7 400 mm 5,9 kg 1<br />

241 94 78 8 450 mm 6,7 kg 1<br />

241 94 79 9 500 mm 7,5 kg 1<br />

241 94 80 10 550 mm 8,2 kg 1<br />

241 94 81 11 600 mm 9,0 kg 1<br />

241 94 82 12 650 mm 9,8 kg 1<br />

1


Produktsortiment |<br />

<strong>LK</strong> 1-Circuit Valve<br />

Valve kit for one under floor heating loop. Consists of a control valve and a adjustment<br />

valve (return) ½” male thread. Must be completed with connection couplings<br />

for current pipe dim: PE-X/PAL pipe in dim 16 (Art. no. 241 74 61) / PE-X pipe in<br />

dim 12x2 (Art. no. 241 74 62) / PE-X pipe in dim 20x2 (Art. no. 241 79 06). Alternatively<br />

<strong>LK</strong> Press Connection <strong>VKF</strong>-i can be used for current pipe dim: PE-X / PAL pipe<br />

in dim 16 (Art. no. 241 91 14) / PE-X pipes in dim 20x2 (Art.no 241 91 15).<br />

1-Circuit Valve can be completed with <strong>LK</strong> Room Control to have electronic temperature<br />

control.<br />

Article no. Dim Package<br />

241 78 49 ½” male 1<br />

<strong>LK</strong> By-Pass <strong>VKF</strong>-i<br />

Complete set with capacity of 0,05 Kvs for mounting on the end of <strong>LK</strong> Manifold<br />

<strong>VKF</strong>-i.<br />

Article no. Length Package<br />

241 78 43 85 mm 1/50<br />

<strong>LK</strong> By-Pass Delta p<br />

Pressure controlled by-pass valve to be mounted on <strong>LK</strong> Manifold <strong>VKF</strong>-i. The product<br />

is delivered complete with new end caps, by-pass valve and by-pass tube.<br />

The opening pressure can be set from 10 - 60 kPa. Maximum capacity 800 l/h.<br />

Article no. Length Package<br />

241 81 87 120 mm 1/50<br />

<strong>LK</strong> Automatic Air Vent<br />

Accessory for <strong>LK</strong> Manifold <strong>VKF</strong>-i.<br />

Article no. Connection Package<br />

241 75 47 ⅜” 1/12<br />

2


Produktsortiment |<br />

<strong>LK</strong> Pressure Gauge <strong>VKF</strong>-i<br />

Pressure Test Gauge for <strong>LK</strong> Manifold <strong>VKF</strong>i. Assemble in place of Manual Air Vent<br />

on End Cap Assembly.<br />

Article no. Dim Measuring area Package<br />

241 94 83 ⅜” 0-6 bar 1/30<br />

<strong>LK</strong> Connection <strong>VKF</strong>-i / 1-Circuit Valve Set<br />

<strong>LK</strong> Connection <strong>VKF</strong>-i / 1-Circuit Valve Set is a complete kit of four adaptors for<br />

connecting <strong>LK</strong> 1-Circuit Valve (Art. no. 241 78 49) to <strong>LK</strong> Manifold <strong>VKF</strong>-i.<br />

Article no.<br />

Package<br />

241 90 90 1<br />

<strong>LK</strong> Balancing Key <strong>VKF</strong>/<strong>VKF</strong>-i<br />

Balancing key to <strong>LK</strong> Manifold <strong>VKF</strong> and <strong>VKF</strong>-i. (Included when purchasing Manifold<br />

<strong>VKF</strong>/<strong>VKF</strong>-i.)<br />

Article no.<br />

Package<br />

241 84 30 1/100<br />

<strong>LK</strong> Return Valve <strong>VKF</strong>/<strong>VKF</strong>-i<br />

Return Valve as spare part to <strong>LK</strong> Manifold <strong>VKF</strong> and <strong>VKF</strong>-i. The return valve is<br />

mounted to the lower manifold, normally provided with actuator.<br />

Article no.<br />

Package<br />

241 84 31 1/10<br />

3


Produktsortiment |<br />

<strong>LK</strong> Mini Manifold<br />

Manifold of brass with integrated balancing lockshield valves for connection of<br />

2-4 under floor heating loops to <strong>LK</strong> Minishunt. Delivered incl. angle couplings<br />

and connection couplers for <strong>LK</strong> PE-X pipe dim 12 mm, PE-X and PAL dim 16 mm<br />

alternatively PE-X dim 20 mm. Mounted on <strong>LK</strong> Minishunt M60 the build height<br />

will increase by approx 90 mm.<br />

Article no. Loops-Pipe dim Length Weight Package<br />

241 74 75 2-12 195 mm 1.2 kg 1/10<br />

241 74 76 3-12 230 mm 1,6 kg 1/10<br />

241 74 77 4-12 265 mm 2,0 kg 1/10<br />

241 74 78 2-16 195 mm 1,2 kg 1/10<br />

241 74 79 3-16 230 mm 1,6 kg 1/10<br />

241 74 80 4-16 265 mm 2,0 kg 1/10<br />

241 77 27 2-20 195 mm 1,2 kg 1/10<br />

241 77 28 3-20 230 mm 1,6 kg 1/10<br />

241 77 29 4-20 265 mm 2,0 kg 1/10<br />

Ancillaries <strong>VKF</strong>-i<br />

<strong>LK</strong> Ball Valve 1”<br />

Isolation valve for <strong>LK</strong> Manifold <strong>VKF</strong>-i.<br />

Article no. Dim Package<br />

241 75 50 1” m/f 1/4/48<br />

<strong>LK</strong> Ball Valve Angle<br />

Isolation valve for <strong>LK</strong> Manifold <strong>VKF</strong>/ <strong>VKF</strong>-i.<br />

Article no. Dim Package<br />

241 79 58 1” m/f 1/6/24<br />

<strong>LK</strong> Ball Valve with Thermometer<br />

Isolation valve with thermometer for <strong>LK</strong> Manifold <strong>VKF</strong>/ <strong>VKF</strong>-i.<br />

Article no. Dim Length Package<br />

241 89 00 1” m/f 110 mm 1/2<br />

4


Produktsortiment |<br />

<strong>LK</strong> Ball Valve Angle with Thermometer<br />

Isolation valve in angle with thermometer for <strong>LK</strong> Manifold <strong>VKF</strong>/ <strong>VKF</strong>-i.<br />

Article no. Dim Length Package<br />

241 89 01 1” m/f 120 mm 1/2<br />

<strong>LK</strong> Connection Set Straight<br />

For connection of feed pipe PE-X to <strong>LK</strong> Manifold <strong>VKF</strong>-i.<br />

Article no. Dim Package<br />

241 81 10 1” male/25x2,3 1/50<br />

241 81 11 1” male/32x2,9 1/40<br />

<strong>LK</strong> Connection Set Angle<br />

For connection of feed pipe PE-X to <strong>LK</strong> Manifold <strong>VKF</strong>-i.<br />

Article no. Dim. Package<br />

241 81 12 1” male/25x2,3 1/40<br />

241 81 13 1” male/32x2,9 1/30<br />

<strong>LK</strong> Joint Nipple PE-X /PAL, straigth<br />

Straigth nipple for PE-X /PAL pipes. Completed with <strong>LK</strong> Connection Coupling<br />

<strong>VKF</strong>-i or <strong>LK</strong> Press Connection Coupling <strong>VKF</strong>-i.<br />

Article no. Nipple connection Package<br />

241 74 67 12/16/20 1/25/250<br />

<strong>LK</strong> Connection Coupling <strong>VKF</strong>/<strong>VKF</strong>-i<br />

For connection of <strong>LK</strong> Under Floor Heating Pipe dim. 12 and 20 and <strong>LK</strong> PE-X Universal<br />

Pipe dim. 16, to <strong>LK</strong> Manifold <strong>VKF</strong>-i.<br />

Article no. Dim Nipple connection Package<br />

241 74 62 12 12/16/20 1/25/250<br />

241 74 61 16 12/16/20 1/25/250<br />

241 79 06 20 12/16/20 1/25/250<br />

5


Produktsortiment |<br />

<strong>LK</strong> Press Connection <strong>VKF</strong>-i<br />

For connection of <strong>LK</strong> PE-X and <strong>LK</strong> PAL Universal pipe dim. 16 mm and <strong>LK</strong> Under<br />

Floor Heating pipe PE-X dim.20 to <strong>LK</strong> Manifold <strong>VKF</strong>-i<br />

Article no. Dim Nipple connection Package<br />

241 91 14 16 12/16/20 1/10/200<br />

241 91 15 20 12/16/20 1/10/200<br />

<strong>LK</strong> Connection Coupling ¾”<br />

For connection of pex pipe to Mini Loop Valve M5 or coupling with ¾” thread.<br />

Article no. Dim Package<br />

187 09 13 3/4” x X12 1/10<br />

187 06 83 3/4” x AX16 1/10<br />

<strong>LK</strong> Coupling Male thread<br />

For <strong>LK</strong> PE-X Universal Pipe PE-X dim. 16 and <strong>LK</strong> Heating Pipe PE-X dim. 12, 20,<br />

25 and 32.<br />

Article no. Dim Package<br />

241 74 66 12 x ½” 1/25/250<br />

241 74 64 16 x ½” 1/25/250<br />

241 79 08 20 x ½” 1/25/250<br />

241 78 99 20 x ¾” 1/25<br />

241 79 09 25 x ¾” 1/25/250<br />

241 81 10 25 x 1” 1/50<br />

241 81 11 32 x 1” 1/40<br />

<strong>LK</strong> Coupling Female thread<br />

For <strong>LK</strong> PE-X Universal Pipe PE-X dim. 16 and <strong>LK</strong> Heating Pipe PE-X dim. 12, 20<br />

and 25.<br />

Article no. Dim Package<br />

241 74 65 12x½” 1/25/250<br />

241 74 63 16x½” 1/25/250<br />

241 79 10 20x½” 1/25/250<br />

241 78 98 20x¾” 1/25<br />

241 79 11 25x¾” 1/25/250<br />

6


Produktsortiment |<br />

<strong>LK</strong> Manifold Screw Plug <strong>VKF</strong>-i<br />

Manifold screw plug with gasket to plug up unused connections on <strong>LK</strong> Manifold<br />

<strong>VKF</strong>-i.<br />

Article no. Dim. Package<br />

241 74 69 12/16/20 1/50/1000<br />

<strong>LK</strong> Manifold Screw Plug Mini<br />

Manifold screw plug with gasket to plug up unused connections on <strong>LK</strong> Mini Manifold.<br />

Article no. Dim Package<br />

241 74 83 12-16 1/50/1000<br />

241 77 37 20 1/50/1000<br />

<strong>LK</strong> Six Edges Nipple<br />

For contraction of <strong>LK</strong> Manifold <strong>VKF</strong>-i / <strong>LK</strong> Mini Manifold.<br />

Article no. Dim Manifold type Package<br />

241 91 10 ¾” <strong>LK</strong> Mini Manifold 1/50<br />

241 74 68 1” male <strong>LK</strong> <strong>VKF</strong>-i 1/25/250<br />

<strong>LK</strong> Pipe Bending Support<br />

Pipe bending support dim 16. Usable with <strong>LK</strong> Fixing plate.<br />

Article no. Pipe dim Radius outer Package<br />

241 75 60 16 mm 120 mm 1/50/1600<br />

7


Produktsortiment |<br />

<strong>LK</strong> Pipe Bending Support PL<br />

Pipe bending support for <strong>LK</strong> PE-X Universal Pipe and <strong>LK</strong> Under Floor Heating<br />

Pipe.<br />

Article no. Pipe dim Radius outer Package<br />

241 80 75 12 mm 85 mm 1/10/50<br />

241 76 87 20 mm 140 mm 1/10/50<br />

241 79 79 25 mm 165 mm 1/10/50<br />

241 79 53 34 mm 210 mm 1/10/50<br />

241 91 38 40 mm 260 mm 1/5/25/600<br />

<strong>LK</strong> Pipe Bending Support Open<br />

Pipe bending support for <strong>LK</strong> Universal Pipe/<strong>LK</strong> Heating Pipe.<br />

Article no. Pipe dim Radius outer Package<br />

241 94 21 8 mm 75 mm 1/10/100/9200<br />

241 79 38 16 mm 120 mm 1/50<br />

<strong>LK</strong> Fixing Plate<br />

Fixes <strong>LK</strong> Pipe Bend Support (art. no. 241 75 60) during installation to <strong>LK</strong> Manifold.<br />

8 loops can be fixed with one plate. The plates can be joined together for increased<br />

number of loops. Material: polythene.<br />

Article no.<br />

Package<br />

241 79 02 1/10<br />

8


Produktsortiment |<br />

Cabinets<br />

<strong>LK</strong> Manifold Cabinet, built in type (INB)<br />

<strong>LK</strong> Manifold Cabinet (INB) is designed for built-into the wall mounting with <strong>LK</strong><br />

Manifold <strong>VKF</strong>-i. In the cabinets that are built into the stud walls with a minimum<br />

stud-frame thickness of 120 mm and a plaster-board wall thickness of 13 mm can<br />

<strong>LK</strong> Manifold <strong>VKF</strong>-i be mounted together with <strong>LK</strong> Manifold Shunt VS or CS. See<br />

range table below.<br />

The cabinets are made of 1 mm thick powder-lacquered metal plating and have<br />

adjustable feets 0-100 mm. The back of the cabinet has adjustable (height and side<br />

ways) ”rails” for manifold. The front of the cabinet is adjustable in depth and removable.<br />

The hatch is delivered with a coin lock and as accessory, a key lock is<br />

available.<br />

Equipped with ”knock out holes” on the sides to enable that the supply and return<br />

pipe can be installed from the side. If the supply- and return pipe are installed<br />

through the knock out holes on the cabinet´s side , then <strong>VKF</strong> 7-8 can be installed<br />

in cabinet INB 2-6. Minimum joist depth is 95 mm if the cabinet shall be built in a<br />

wall.<br />

Article no. W x H x D Size<br />

<strong>VKF</strong>/<br />

<strong>VKF</strong>-i<br />

Manifold<br />

shunt +<br />

<strong>VKF</strong>-i<br />

Colour<br />

code<br />

Weight<br />

Package<br />

241 78 89 540 x 780 x 106 mm 2-6 - RAL 9010 13.0 kg 1/19<br />

241 78 90 800 x 780 x 106 mm 2-12 VS/CS RAL 9010 15.0 kg 1/12<br />

+<strong>VKF</strong>-i 2-5<br />

241 80 78 1150 x 780 x 106 mm 2-12 VS/CS<br />

+<strong>VKF</strong>-i 2-12<br />

RAL 9010 25.0 kg 1/10<br />

9


Produktsortiment |<br />

<strong>LK</strong> Manifold Cabinet, on the wall type (UTV)<br />

<strong>LK</strong> Manifold Cabinet UTV is designed for mounting outside of the existing walls<br />

with <strong>LK</strong> Manifold <strong>VKF</strong>-i. In the cabinets with a minimum stud-frame thickness<br />

of 120 mm can <strong>LK</strong> Manifold (<strong>VKF</strong>-i) also be mounted together with <strong>LK</strong> Manifold<br />

Shunt VS. In the cabinets with a minimum stud-frame thickness of 180 mm can <strong>LK</strong><br />

Manifold (<strong>VKF</strong>-i) be mounted together with <strong>LK</strong> Manifold Shunt CS or <strong>LK</strong> Heat<br />

Exchanger Pack -10. See range table below.<br />

The cabinets are made of 1 mm thick powder-lacquered metal plating and the<br />

base of the cabinet is removable for convenient installtion. The back has adjustable<br />

(height and side ways) ”rails” for the manifold. The hatch is delivered with a coin<br />

lock and as accessory, a key lock is available.<br />

Equipped with ”knock out holes” on the sides to enable that the supply and return<br />

pipe can be installed from the side. If the supply- and return pipe are installed<br />

through the knock out holes on the cabinet´s side, then <strong>VKF</strong> 7-8 can be installed in<br />

cabinet INB 2-6.<br />

Article no. W x H x D Size<br />

<strong>VKF</strong>-i<br />

Mnifol Shunt or H<br />

Exchg.p. + <strong>VKF</strong>-i<br />

Colour<br />

code<br />

241 78 91 595x780x120 mm 2-6 - RAL<br />

9010<br />

241 78 92 800x780x120 mm 2-12 VS+<strong>VKF</strong>-i 2-5 RAL<br />

9010<br />

241 80 79 1150x780x120 mm 2-12 VS+<strong>VKF</strong>-i 2-12 RAL<br />

9010<br />

241 86 88 800x780x180 mm 2-12 VS/CS+<strong>VKF</strong>-i 2-5 RAL<br />

9010<br />

241 86 89 1150x780x180 mm 2-12 VS/CS+<strong>VKF</strong>-i 2-12<br />

H Exchg. p. 10<br />

+<strong>VKF</strong>-i 2-12<br />

RAL<br />

9010<br />

Weight Package<br />

12 kg 1/18<br />

15 kg 1/18<br />

25 kg 1/10<br />

16,5 kg 1/12<br />

28 kg 1/8<br />

<strong>LK</strong> Hatch<br />

Installation hatch with frame to be mounted in the wall. The hatch has a coin lock,<br />

as an accessory there is a key lock. The frame and hatch is made by 1 mm stove<br />

enamelled steel plate. <strong>LK</strong> Hatch must be placed directly on the floor. The bottom<br />

of the frame is adjustable in height.<br />

Article no. W x H Size <strong>VKF</strong>-i Colour code Weight Package<br />

241 81 14 540x760-800 mm <strong>VKF</strong>-i 2-6 RAL 9010 4.2 kg 1<br />

241 81 15 800x760-800 mm <strong>VKF</strong>-i 2-12 RAL 9010 4.8 kg 1<br />

241 81 16 1150x760-800 mm <strong>VKF</strong>-i 2-12 RAL 9010 7.5 kg 1<br />

10


Produktsortiment |<br />

<strong>LK</strong> Cabinet One WP<br />

The <strong>LK</strong> Cabinet One WP is designed for concealing or protecting the <strong>LK</strong> 1-Circuit<br />

Valve in the wall. The cabinet is made of 1 mm powder coated steel.<br />

The <strong>LK</strong> Cabinet One WP is installed in-built into a wall with a minimum thickness<br />

of 70 mm. The cabinet has a thick base with pipe through-holes sealed with rubber<br />

that allow any leaks to be drained to the optional inspection point.<br />

The cabinet is supplied with a fitted door, pipe rubber seals, power supply holes,<br />

spray protection and assembly instructions. The cabinet’s side sections are fitted<br />

with knockout holes for possible feeding of the supply and return flow to the side.<br />

Article no. W x H x D Colour code Weight Package<br />

241 90 82 325 x 325 x 83 mm RAL 9010 3,1 kg 1<br />

<strong>LK</strong> Manifold Cabinet WP<br />

The <strong>LK</strong> Manifold Cabinet WP The <strong>LK</strong> Manifold Cabinet WP (water proof) is designed<br />

for concealing or protecting <strong>LK</strong> Under Floor Heating manifold <strong>VKF</strong>-i. The<br />

cabinet has a rigid base complete with pipe entry-holes sealed by rubber gaskets<br />

that ensure any leeks can be drained to the optional inspection point. The cabinet<br />

is manufactured of 1mm powder coated steel plate.<br />

The cabinet is supplied complete with door and frame. Additionally pipe gasket<br />

seals, spray shields and installation instructions are packed in the box. The hatch<br />

of the cabinet is fitted as standard with a screwdriver catch. Lock and keys are<br />

available as accessories.<br />

The cabinet’s side sections are fitted with knockout holes for possible feeding of<br />

the supply and return flow to the side.<br />

The <strong>LK</strong> Manifold Cabinet WP can be installed in stud walls with minimum studframe<br />

of 95 mm. The rear side of the cabinet is equipped with four M8 bolts which<br />

can be used for attaching when the cabinet is to be mounted prior to casting the<br />

cement platform. The cabinet can also be mounted on existing walls by using <strong>LK</strong><br />

Base, which then conceals the pipe installation between the cabinet and the floor.<br />

<strong>LK</strong> Manifold Cabinet WP is not intended for <strong>LK</strong> Manifold Shunt.<br />

Article no. W x H x D <strong>VKF</strong>-i Weight Colour code Package<br />

241 88 39 550 x 710 x 95 mm 2-6 11,0 kg Ral 9010 1/12<br />

241 88 40 800 x 710 x 95 mm 2-12 17,6 kg Ral 9010 1/10<br />

241 88 45 900 x 710 x 95 mm 2-12 19,2 kg Ral 9010 1/9<br />

11


Produktsortiment |<br />

<strong>LK</strong> Shunt Cabinet WP<br />

<strong>LK</strong> Shunt Cabinet WP is intended for use where <strong>LK</strong> Floor Heating Manifold <strong>VKF</strong>-i<br />

and <strong>LK</strong> Manifold Shunt CS are to be hidden. The cabinet is made of 1 mm thick<br />

powder-lacquered metal plating. NOTE! <strong>LK</strong> Manifold Shunt CS must be mounted<br />

on the right side of the cabinet.<br />

<strong>LK</strong> Shunt Cabinet WP can be mounted built-into the wall with a minimum joist<br />

thickness of 120 mm. The cabinet can also be mounted outside of existing walls<br />

with the help of accessory <strong>LK</strong> Base which hides the piping between cabinet and<br />

floor. The cabinet has a water-tight base with rubber pipe grommets allowing any<br />

water leakage to be drained off to an optional place for inspection. The rear side of<br />

the cabinet is equipped with four M8 bolts which can be used for attaching when<br />

the cabinet is to be mounted prior to casting the cement platform.<br />

The cabinet is supplied complete with door and frame. Additionally pipe gasket<br />

seals, spray shields and installation instructions are packed in the box. The hatch<br />

of the cabinet is fitted as standard with a screwdriver catch. Lock and keys are<br />

available as accessories.<br />

Article no. W x H x D Manifold Shunt + Color Weight Package<br />

<strong>VKF</strong>-i<br />

241 89 39 800 x 710 x 120 mm VS/CS + <strong>VKF</strong>-i 2-5 RAL 9010 14,6 kg 1/7<br />

241 89 42 1150 x 710 x 120 mm VS/CS + <strong>VKF</strong>-i 2-12 RAL 9010 20,2 kg 1/5<br />

<strong>LK</strong> Base WP<br />

<strong>LK</strong> Base WP is used to conceal pipe installation between the <strong>LK</strong> Manifold Cabinet<br />

WP /<strong>LK</strong> Shunt Cabinet WP and the floor when the cabinet is installed on existing<br />

walls. <strong>LK</strong> Base WP sliding in height between 120-150 mm.<br />

Article no. W x H x D Colour Code Weight Package<br />

241 88 41 550 x 150 x 95 mm Ral 9010 1,5 kg 1<br />

241 89 36 900 x 150 x 95 mm Ral 9010 2,4 kg 1<br />

241 89 41 800 x 150 x 120 mm Ral 9010 2,3 kg 1<br />

241 89 40 1150 x 150 x 120 mm Ral 9010 3,3 kg 1<br />

12


Produktsortiment |<br />

<strong>LK</strong> Hatch WP<br />

<strong>LK</strong> Hatch WP is designed to be used as a spare part to <strong>LK</strong> Manifold Cabinet WP/<br />

<strong>LK</strong> Shunt Cabinet WP, it can also be used to cover built in installations. The Hatch<br />

is delivered with a frame for attachment to <strong>LK</strong> Manifold Cabinet WP/ <strong>LK</strong> Shunt<br />

Cabinet WP or wall.<br />

As standard the hatch is fitted with a screwdriver catch. Lock and keys are available<br />

as accessories. Hatch and frame is manufactured of 1 mm powder coated steel<br />

plate.<br />

Article no. W x H x D Colour code Weight Package<br />

241 88 43 550 x 690 x 15 mm Ral 9010 3,8 kg 1<br />

241 88 44 800 x 690 x 15 mm Ral 9010 5,5 kg 1<br />

241 89 35 900 x 690 x 15 mm Ral 9010 6,2 kg 1<br />

<strong>LK</strong> Key Lock<br />

Key lock for <strong>LK</strong> Manifold Cabinet INB/UTV/WP and <strong>LK</strong> Hatch/Hatch WP.<br />

Article no.<br />

Package<br />

000 27 85 1<br />

<strong>LK</strong> Minishunt Cabinet M60<br />

The Cabinet is made as a hood to cover the Minishunt M60 incl. <strong>LK</strong> Mini Manifold.<br />

The Cabinet is made of white laminated chipboard. It should be placed on the floor<br />

and fixed to the wall.<br />

Article no. W x H x D Size Minishunt Weight Package<br />

241 80 35 532 x 568 x 171 mm 2-4 7,0 kg 1<br />

13


Prefabricated<br />

<strong>LK</strong> Manifold Cabinet VT - COMPLETE<br />

<strong>LK</strong> Manifold Cabinet VT – COMPLETE, is supplied pre-assembled with <strong>LK</strong> Manifold<br />

<strong>VKF</strong>-i. On the supply of the manifold there is isolation valve mounted with<br />

a thermometer. In the return of the manifold, there is <strong>LK</strong> OpiFlow mounted for<br />

flow adjustment. OptiFlow-valve is also used as isolation. The cabinet includes lid,<br />

frame, pipe inlets, <strong>LK</strong> Connection couplings to PE-X /PAL pipe, dim 16 (Article no<br />

241 74 61), splash protection and assembly instructions. The cabinet lid is supplied<br />

as standard with a screwdriver lock; a key lock as available as an accessory. The<br />

cabinet has a water-tight base with sealed outlets to allow accidental water leakage<br />

to be drained to a drain or wet-proof area.<br />

Note! The cabinet is manufactured for right hand assembly only, i.e. the primary<br />

supply connection to the manifolds is on the right of the cabinet, either through<br />

the side panel or through the base. <strong>LK</strong> Manifold Cabinet VT can be built into stud<br />

walls with a minimum cavity of 95 mm. The cabinet can also be mounted onto<br />

walls by using <strong>LK</strong> Base to conceal the pipes between the cabinet and floor. The<br />

side panels of the cabinet are provided with knock-out holes for primary supply<br />

and return lines. The back of the manifold cabinet is fitted with four fasteners (M8<br />

bolts) than can be used as an attachment to the <strong>LK</strong> Cabinet Stand when you wish<br />

to mount the cabinet before the concrete slab has set.<br />

Assembly of the cabinet may be augmented <strong>LK</strong> Cabinet Stand<br />

Article no. W x H x D <strong>VKF</strong>-i Color Weight Package<br />

241 69 79 550 x 710 x 95 mm 2 Ral 9010 15,7 kg 1<br />

241 69 80 550 x 710 x 95 mm 3 Ral 9010 16,6 kg 1<br />

241 69 81 550 x 710 x 95 mm 4 Ral 9010 16,7 kg 1<br />

241 69 82 550 x 710 x 95 mm 5 Ral 9010 17,8 kg 1<br />

241 69 83 900 x 710 x 95 mm 6 Ral 9010 26,3 kg 1<br />

241 69 84 900 x 710 x 95 mm 7 Ral 9010 27,2 kg 1<br />

241 69 85 900 x 710 x 95 mm 8 Ral 9010 28,2 kg 1<br />

241 69 86 900 x 710 x 95 mm 9 Ral 9010 29,1 kg 1<br />

241 69 87 900 x 710 x 95 mm 10 Ral 9010 30,0 kg 1<br />

241 69 88 900 x 710 x 95 mm 11 Ral 9010 30,9 kg 1<br />

241 69 89 900 x 710 x 95 mm 12 Ral 9010 31,8 kg 1<br />

14


<strong>LK</strong> Shunt Cabinet VT - COMPLETE<br />

<strong>LK</strong> Shunt Cabinet VT – COMPLETE is supplied pre-assembled <strong>LK</strong> Manifold Shunt<br />

CS and <strong>LK</strong> Manifold <strong>VKF</strong>-i. The cabinet has a water-tight base with sealed outlets<br />

to allow accidental water leakage to be drained to a drain or wet-proof area.<br />

Note! The cabinet is manufactured for right-hand assembly, i.e. primary side connection<br />

is from the right side of the cabinet base.<br />

<strong>LK</strong> Shunt Cabinet VT can be built into walls with a minimum stud cavity of 120<br />

mm. The cabinet can also be mounted onto walls by using <strong>LK</strong> Base to conceal the<br />

pipes between the cabinet and floor. The cabinet has a water-tight base with sealed<br />

outlets to allow accidental water leakage to be drained to a drain or wet-proof area.<br />

The back of the cabinet is supplied with four M8 bolts for pre-installation if walls<br />

are to be built after the floor heating has been installed.<br />

The cabinet includes lid, frame, pipe inlets, <strong>LK</strong> Connection Couplings to PE-X /<br />

PAL pipe, dim 16 (Article no 241 74 61), splash protection and assembly instructions.<br />

The cabinet lid is supplied as standard with a screwdriver lock; a key lock as<br />

available as an accessory.<br />

Article no. W x H x D <strong>VKF</strong>-i Color Weight Package<br />

241 69 90 800 x 710 x 120 2 Ral 9010 24,0 kg 1<br />

241 69 91 800 x 710 x 120 3 Ral 9010 24,7 kg 1<br />

241 69 92 800 x 710 x 120 4 Ral 9010 25,0 kg 1<br />

241 69 93 800 x 710 x 120 5 Ral 9010 26,0 kg 1<br />

241 69 94 1150 x 710 x 120 6 Ral 9010 32,5 kg 1<br />

241 69 95 1150 x 710 x 120 7 Ral 9010 33,5 kg 1<br />

241 69 96 1150 x 710 x 120 8 Ral 9010 34,5 kg 1<br />

241 69 97 1150 x 710 x 120 9 Ral 9010 35,5 kg 1<br />

241 69 98 1150 x 710 x 120 10 Ral 9010 36,0 kg 1<br />

241 69 99 1150 x 710 x 120 11 Ral 9010 37,0 kg 1<br />

241 70 00 1150 x 710 x 120 12 Ral 9010 38,0 kg 1<br />

15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!