1602M03 PLED - Robotikhardware.de
1602M03 PLED - Robotikhardware.de
1602M03 PLED - Robotikhardware.de
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Data International Co., Ltd.<br />
DATAVISION<br />
APPROVAL SHEET<br />
Customer :<br />
Part Name :<br />
LCD MODULE<br />
Mo<strong>de</strong>l No. : <strong>1602M03</strong> <strong>PLED</strong><br />
Drawing No. :<br />
Approved by :<br />
Date :<br />
Approved Checked Prepared Sheet Co<strong>de</strong>:<br />
Will-Chiu<br />
DEMA electronic GmbH, Tuerkenstr. 11, 80333 Muenchen<br />
Tel. +49 89 286941-0, Fax. +49 89 283509<br />
Email. info@<strong>de</strong>ma.net, http//:www.<strong>de</strong>ma.net
1. Contents<br />
.<br />
SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY MODULE<br />
MODEL NO: <strong>1602M03</strong> <strong>PLED</strong><br />
1. Contents………………………………………………………………..2<br />
2. Features………………………………………………………………..3<br />
3. Recommen<strong>de</strong>d Operating Conditions……………………………….3<br />
4. Electrical Characteristics……………………………………………...4<br />
4.1 DC Electrical Characteristics………...……………………….…4<br />
5. Optical Specifications…………………………………………….…...4<br />
6. AC Electrical Characteristics………………………………………….5<br />
6.1 Write operation……………………………………………………5<br />
6.2 Read operation…………………………………………………...6<br />
6.3 Display Data RAM (DDRAM)……………………………………6<br />
6.4 Character Font Table……………………………………………..7<br />
6.5 Instruction set……………………………………………………...8<br />
6.6 Initialization via Instruction……………………………………….9<br />
7. Block Diagram…………………………………………………………11<br />
8.Interface Pin Function…………………………………………………11<br />
9.LCM Drawing…………………………………………………………..12<br />
10. Reliability……………………………………………………………..13<br />
10.0. Reliability test item…………………………………………….13<br />
10.2. Life………………………………………………………………13<br />
11. <strong>PLED</strong> LCM……………………………………………………………13<br />
DATA VISION 2005/10/11 2 / 13
2. Features<br />
SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY MODULE<br />
MODEL NO: <strong>1602M03</strong> <strong>PLED</strong><br />
Item<br />
Contents<br />
Display Format 2 lines of 16 characters of 5 x 8 (dots)<br />
Character Size 5.5 x 2.9 mm<br />
Dot Size<br />
0.5 x 0.6 mm<br />
View Area 66.0 x 16.0<br />
General Dimensions 84.0(W) x 44.0(H) x 9.4(T)(Max.) mm<br />
Controller PTC6880 x 1<br />
Driver PTC6800 x 1<br />
Temperature Range -20~50<br />
Display Color Green<br />
Weight<br />
27 g<br />
3. Recommen<strong>de</strong>d Operating Conditions<br />
Symbol Parameter Min Typ Max Unit<br />
VDD Supply voltage for Logic 4.5 5.0 5.5 V<br />
Topr Operating temperature -20 25 50<br />
o C<br />
Tstg Storage temperature -30 70<br />
o C<br />
Vbt Brightness control voltage 3 V<br />
Tsol<strong>de</strong>r Sol<strong>de</strong>ring Temperature 260 o C for 5 seconds<br />
Pd<br />
Module power consumption<br />
@Vbt=3V (Note 1) VDD=5V<br />
63 mW<br />
Item<br />
Operating Storage<br />
Min. Max. Min. Max.<br />
Ambient -20 o C 50 o C -30 o C 70 o C<br />
Temperature<br />
Humidity 40 o C 90%RH 40 o C 90%RH<br />
DATA VISION 2005/10/7 3 / 13
SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY MODULE<br />
MODEL NO: <strong>1602M03</strong> <strong>PLED</strong><br />
4. Electrical Characteristics<br />
4.1 DC Electrical Characteristics<br />
(Ta= -20 to 50 o C)<br />
Item Symbol Condition Min Typ Max Unit<br />
Power supply voltage VDD 4.5 5 5.5 V<br />
Brightness control voltage VBT - 3 - V<br />
Power supply current Icc VDD=5V - 0.35 0.6 mA<br />
High level input voltage Vih 0.7VDD - VDD V<br />
Low level input voltage Vil -0.3 - 0.55 V<br />
Leakage current Il -1 - 1 uA<br />
5. Optical Specifications<br />
Item Condition Min. Typ. Max. Unit<br />
Response time Rise - 10 - us<br />
Fall - 10 - us<br />
Contrast ratio 100 lux - 100 -<br />
Viewing angle Top - 80 - <strong>de</strong>g<br />
Bottom - 80 - <strong>de</strong>g<br />
Left - 80 - <strong>de</strong>g<br />
right - 80 - <strong>de</strong>g<br />
Brightness With polarizer - 40 - nits<br />
Color - G 1 -<br />
Note 1. G=green<br />
DATA VISION 2005/10/7 4 / 13
SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY MODULE<br />
MODEL NO: <strong>1602M03</strong> <strong>PLED</strong><br />
6. AC Electrical Characteristics<br />
6.1 Write operation<br />
Item Symbol Min Typ Max Unit<br />
Enable Cycle Time Tcyc 500 ns<br />
Enable Pulse Width (High level) Pweh 230 ns<br />
Enable Rise/ Fall Time tEf, tEr 20 ns<br />
Address Set-up Time tAS 40 ns<br />
Address Hold Time tAH 10 ns<br />
Data Set-up Time tDSW 80 ns<br />
Data Hold Time tH 10 ns<br />
RS<br />
tAS Pweh tAH<br />
R/W<br />
tEf<br />
tH<br />
E<br />
tEr<br />
tDSW<br />
D0~D7<br />
Tcyc<br />
DATA VISION 2005/10/7 5 / 13
SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY MODULE<br />
MODEL NO: <strong>1602M03</strong> <strong>PLED</strong><br />
6.2 Read operation<br />
Item Symbol Min Typ Max Unit<br />
Enable Cycle Time Tcyc 500 ns<br />
Enable Pulse Width (High level) Pweh 230 ns<br />
Enable Rise/ Fall Time tEf, tEr 20 ns<br />
Address Set-up Time tAS 40 ns<br />
Address Hold Time tAH 10 ns<br />
Data Delay Time tDDR 160 ns<br />
Data Hold Time tH 5 ns<br />
RS<br />
tAS<br />
Pweh<br />
tAH<br />
R/W<br />
tEf<br />
tH<br />
E<br />
tEr<br />
tDDR<br />
D0~D7<br />
Tcyc<br />
6.3 Display Data RAM (DDRAM)<br />
Display 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16<br />
Position<br />
DDRAM 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F<br />
Address 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F<br />
For shift left<br />
01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10<br />
41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50<br />
For shift right<br />
27 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E<br />
67 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E<br />
DATA VISION 2005/10/7 6 / 13
SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY MODULE<br />
MODEL NO: <strong>1602M03</strong> <strong>PLED</strong><br />
6.4 Character Font Table<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
DATA VISION 2005/10/7 7 / 13
6.5 Instruction set<br />
SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY MODULE<br />
MODEL NO: <strong>1602M03</strong> <strong>PLED</strong><br />
Co<strong>de</strong><br />
Instruction RS R/W D7 D6 D5 D4 D3 D2 D1 D0 Description<br />
Clear Display 0 0 0 0 0 0 0 0 0 1 Clear entire display. Sets DDRAM<br />
address 0 into address counter<br />
Entry mo<strong>de</strong> set 0 0 0 0 0 0 0 1 I/D S Sets cursor move direction and<br />
Display On/Off<br />
control<br />
specifies display shift<br />
0 0 0 0 0 0 1 D C B Sets entire display (D) On/Off<br />
Sets cursor (C) On/Off<br />
Sets Blinking (B) of cursor position<br />
character<br />
Cursor/display<br />
shift<br />
0 0 0 0 0 1 S/C R/L X X Moves cursor & shifts display without<br />
changing DDRAM contents<br />
Function set 0 0 0 0 1 DL N F X X Sets interface data length (DL)<br />
Sets number of display lines (N)<br />
Sets character font (F)<br />
Set CGRAM<br />
address<br />
Set DDRAM<br />
address<br />
0 0 0 1 ACG ACG ACG ACG ACG ACG Sets CGRAM address.<br />
CGRAM data is sent and received<br />
after this setting.<br />
0 0 1 ADD ADD ADD ADD ADD ADD ADD Sets DDRAM address.<br />
The DDRAM data bus sent and<br />
received after this setting<br />
Execution<br />
time<br />
1.52ms<br />
37us<br />
37us<br />
37us<br />
37us<br />
37us<br />
37us<br />
Read busy flag<br />
& address<br />
Write data into<br />
the CGRAM or<br />
DDRAM<br />
Read data into<br />
the CGRAM or<br />
DDRAM<br />
0 1 BF AC AC AC AC AC AC AC Reads busy flag (BF) indicating that<br />
internal operation is being performed<br />
Reads address counter contents<br />
1 0 Write data Write data into the CGRAM or<br />
DDRAM<br />
1 1 Read data Read data from the CGRAM or<br />
DDRAM<br />
I/D =1: Increment<br />
S =1: Display shift on<br />
D =1: Display on<br />
C =1: Cursor display on<br />
B =1: Cursor blink on<br />
S/C =1: Shift display<br />
R/L =1: Shift right<br />
DL =1: 8-bit<br />
N =1:Dual line<br />
F =1:5x10 dots<br />
BF =1:Internal operation<br />
BF =0:Ready for instruction<br />
I/F=0:Decrement<br />
S/C=0: Move cursor<br />
R/L=0:Shift left<br />
DL=0:4-bit<br />
N =0:Single line<br />
F =0:5x8 dots<br />
DDRAM: Display Data RAM<br />
CGRAM: Character Generator RAM<br />
ACG: Character Generator RAM<br />
Address<br />
ADD: Display Data RAM Address<br />
AC: Address Counter<br />
0us<br />
37us<br />
37us<br />
DATA VISION 2005/10/7 8 / 13
SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY MODULE<br />
MODEL NO: <strong>1602M03</strong> <strong>PLED</strong><br />
6.6 Initialization via Instruction<br />
8-BIT INTERFACE<br />
The procedures of the initialization of an 8-bit MPU as follows.<br />
Power ON<br />
<br />
WAIT FOR MORE THAN 15ms AFTER THE VDD RISES TO 4.5V<br />
<br />
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 BF CANNOT BE CHECKED BEFORE THIS<br />
0 0 0 0 1 1 * * * * INSTRUCTION.<br />
<br />
WAIT FOR MORE THAN 4.1ms<br />
FUNCTION SET (INTERFACE IS 8 BITS<br />
LONG)<br />
<br />
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 BF CANNOT BE CHECKED BEFORE THIS<br />
0 0 0 0 1 1 * * * * INSTRUCTION.<br />
<br />
WAIT FOR MORE THAN 100 us<br />
FUNCTION SET (INTERFACE IS 8 BITS<br />
LONG)<br />
<br />
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 BF CANNOT BE CHECKED BEFORE THIS<br />
0 0 0 0 1 1 * * * * INSTRUCTION.<br />
<br />
<br />
FUNCTION SET (INTERFACE IS 8 BITS<br />
LONG)<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
BF CAN BE CHECKED AFTER THE<br />
FOLLOWING INSTRUCTIONS. WHEN BF IS<br />
NOT CHECKED, THE WAITING TIME<br />
BETWEEN THE INSTRUCTIONS IS<br />
LONGER THAN THE EXECUTION TIME OF<br />
THE INSTRUCTION<br />
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 END OF INITIALIZATION<br />
0 0 0 0 1 1 N F * * FUNCTION SET (INTERFACE IS 8 BITS<br />
0 0 0 0 0 0 1 0 0 0 LONG) SPECIFY THE NUMBER OF<br />
0 0 0 0 0 0 0 0 0 1 DISPLAY LINES AND CHARACTER FONT)<br />
0 0 0 0 0 0 0 1 I/D S THE NUMBER OF CHARACTER LINES AND<br />
<br />
<br />
<br />
END OF INITIALIZATION<br />
CHARACTER FONT CANNOT BE<br />
CHANGED AFTER THIS POINT.<br />
DISPLAY OFF<br />
DISPLAY CLEAR<br />
ENTRY MODE<br />
DATA VISION 2005/10/7 9 / 13
SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY MODULE<br />
MODEL NO: <strong>1602M03</strong> <strong>PLED</strong><br />
4-BIT INTERFACE<br />
The procedures of the initialization of an 4-bit MPU as follows.<br />
Power ON<br />
WAIT FOR MORE THAN 15ms AFTER<br />
THE VDD RISES TO 4.5V<br />
RS R/W DB7 DB6 DB5 DB4 BF CANNOT BE CHECKED BEFORE THIS INSTRUCTION.<br />
0 0 0 0 1 1 FUNCTION SET (INTERFACE IS 8 BITS LONG.)<br />
WAIT FOR MORE THAN 4.1ms<br />
RS R/W DB7 DB6 DB5 DB4 BF CANNOT BE CHECKED BEFORE THIS INSTRUCTION.<br />
0 0 0 0 1 1 FUNCTION SET (INTERFACE IS 8 BITS LONG.)<br />
WAIT FOR MORE THAN 100 us<br />
RS R/W DB7 DB6 DB5 DB4 BF CANNOT BE CHECKED BEFORE THIS INSTRUCTION.<br />
0 0 0 0 1 1 FUNCTION SET (INTERFACE IS 8 BITS LONG.)<br />
RS R/W DB7 DB6 DB5 DB4 BF CAN BE CHECKED AFTER THE FOLLOWING INSTRUCTIONS.<br />
0 0 0 0 1 0 WHEN THE BF IS NOT CHECKED, THE WAITING TIME BETWEEN<br />
0 0 0 0 1 0 THE INSTRUCTIONS IS LONGER THAN THE TIME IT TAKES FOR<br />
0 0 N F * * THE INSTRUCTION TO BE EXECUTED.<br />
0 0 0 0 0 0 FUNCTION SET (SET INTERFACE IS 4 BIT LONG)<br />
0 0 1 0 0 0 INTERFACE IS 8 BITS LONG<br />
0 0 0 0 0 0 FUNCTION SET (INTERFACE IS 4 BIT LONG. SPECIFY THE<br />
0 0 0 0 0 1 NUMBEROF DISPLAY LINES AND CHARACTER FONT).<br />
0 0 0 0 0 0 THE NUMBER OF DISPLAY LINES AND CHARACTER FONT<br />
0 0 0 1 I/D S CANNOT BE CHANGED AFTER THIS POINT.<br />
DISPLAY OFF<br />
DISPLAY CLEAR<br />
END OF INITIALIZATION<br />
END OF INITIALIZATION ENTRY MODE SET<br />
DATA VISION 2005/10/7 10 / 13
7.Block Diagram<br />
SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY MODULE<br />
MODEL NO: <strong>1602M03</strong> <strong>PLED</strong><br />
VDD<br />
VSS<br />
VBT<br />
16<br />
<strong>PLED</strong> PANEL<br />
16Char x 2Line<br />
RS<br />
R/W<br />
Controller<br />
&<br />
Driver<br />
40<br />
40<br />
E<br />
D0~D7<br />
Driver<br />
V<strong>PLED</strong><br />
8.Interface Pin Function<br />
Pin No. Symbol I/O Function<br />
1 VSS I Ground<br />
2 VDD I Power supply for logic<br />
3 VBT I Brightness adjustment**<br />
4 RS I<br />
H: Data<br />
5 R/W I<br />
L: Instruction co<strong>de</strong><br />
H: Read<br />
L: Write<br />
6 E I HL: Enable<br />
7 D0 I<br />
8 D1 I<br />
9 D2 I<br />
10 D3 I<br />
11 D4 I<br />
Data bus<br />
12 D5 I<br />
13 D6 I<br />
14 D7 I<br />
15 NC - -<br />
16 NC - -<br />
** VBT= Type +3V<br />
DATA VISION 2005/10/7 11 / 13
10.Reliability<br />
SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY MODULE<br />
MODEL NO: <strong>1602M03</strong> <strong>PLED</strong><br />
10.1 Reliability test item<br />
NO. Test items Conditions<br />
1 High temperature storage 70 o C , 240 hrs<br />
2 Low temperature storage -30 o C,240 hrs<br />
3 High temperature 50 o C,240 hrs<br />
operation<br />
4 Low temperature -20 o C,240 hrs<br />
operation<br />
5 High temperature and 40 o C, 90% RH, 240 hrs<br />
high humidity storage test<br />
6 Temperature Shock<br />
(operating)<br />
-20 o C (30 mins.) -->25 o C( 5 mins.) --> +70 o C (30<br />
mins.) --> 25 o C( 5 mins.) --> -20 o C (30 mins.), 20<br />
Cycles<br />
7 ESD test (IEC61000-4-2) • Static (contact: level 2 , air: level 2 )<br />
• Operation (contact: level 2 , air: level 2 )<br />
10.2 Life<br />
Item Standard value Unit<br />
Operation 10000 Hours<br />
Storage 5 Years<br />
Note :<br />
1.Simulation pattern for operation test: interchanging with all-pixels on, chess, reversed chess, all-pixels off.<br />
2.The brightness <strong>de</strong>cay does not exceed 50%.<br />
11. <strong>PLED</strong> LCM<br />
DATA VISION 2005/10/11 13 / 13