Page 10 of <strong><strong>Europe</strong>an</strong> technical approval <strong>ETA</strong>-<strong>08</strong>/<strong>0376</strong>, issued on 8 September 2011<br />
Cartridge: <strong>Powers</strong> PURE150-PRO<br />
385 ml, 585 ml and 1400 ml injection mortar cartridge (Type: “side-by-side”)<br />
Imprint: <strong>Powers</strong> PURE150-PRO, processing<br />
notes, charge-code, shelf life, hazard-code,<br />
curing- and processing time (depending on the<br />
temperature), with as well as without travel scale<br />
Component A:<br />
Injection mortar<br />
Component B:<br />
Hardener<br />
Sealing /<br />
Screw cap<br />
Static mixing nozzle:<br />
Use category:<br />
- Hammer-drilling<br />
- Application in cracked concrete, option 1<br />
- Installation in dry, wet concrete (until h ef = 20·d) or flooded boreholes<br />
(only until h ef = 12·d)<br />
- Overhead installation<br />
Temperature range: - 40°C to +40°C (max. short term temperature +40°C and<br />
max. long term temperature +24°C)<br />
- 40°C to +60°C (max. short term temperature +60°C and<br />
max. long term temperature +43°C)<br />
- 40°C to +72°C (max. short term temperature +72°C and<br />
max. long term temperature +43°C)<br />
<strong>Powers</strong> PURE150-PRO Injection resin with anchor rod for concrete<br />