Page 18 of <strong><strong>Europe</strong>an</strong> technical approval <strong>ETA</strong>-<strong>08</strong>/<strong>0376</strong>, issued on 8 September 2011<br />

Table 10: Design method A:<br />

Characteristic values for tension loads in cracked concrete<br />

Anchor size threaded rod M 12 M 16 M 20 M 24 M 27 M 30<br />

Steel failure<br />

Characteristic tension resistance,<br />

Steel, property class 5.8<br />

Characteristic tension resistance,<br />

Steel, property class 8.8<br />

Partial safety factor γ Ms,N<br />

1)<br />

Characteristic tension resistance,<br />

Stainless steel A4 and HCR,<br />

property class 50 (>M24) and 70 (≤ M24)<br />

Partial safety factor γ Ms,N<br />

1)<br />

Combined pullout and concrete cone failure<br />

Characteristic bond resistance τ Rk,cr [N/mm²] in cracked concrete C20/25<br />

N Rk,s [kN] 42 78 122 176 230 280<br />

N Rk,s [kN] 67 125 196 282 368 449<br />

1,50<br />

N Rk,s [kN] 59 110 171 247 230 281<br />

1,87 2,86<br />

Temperature range I 4) :<br />

40°C/24°C<br />

Temperature range II 4) :<br />

60°C/43°C<br />

Temperature range III 4) :<br />

72°C/43°C<br />

dry and wet concrete<br />

h ef ≤12d<br />

h ef >12d<br />

7,5<br />

7,0<br />

flooded bore hole 5) h ef ≤12d 7,5 6,0 5,0 4,5 4,0 4,0<br />

dry and wet concrete<br />

h ef ≤12d<br />

h ef >12d<br />

4,5<br />

4,0<br />

6,5<br />

6,5<br />

6,0<br />

6,0<br />

5,5<br />

5,5<br />

4,0 3,5 3,5<br />

4,0 3,5 3,5<br />

flooded bore hole 5) h ef ≤12d 4,5 4,0 3,5 3,5 3,5 3,5<br />

dry and wet concrete<br />

h ef ≤12d<br />

h ef >12d<br />

4,0<br />

3,5<br />

flooded bore hole 5) h ef ≤12d 4,0 3,5 3,0 3,0 3,0 3,0<br />

3,5<br />

3,5<br />

3,0<br />

3,0<br />

3,0<br />

3,0<br />

5,5<br />

5,5<br />

3,5<br />

3,5<br />

3,0<br />

3,0<br />

5,5<br />

5,5<br />

3,5<br />

3,5<br />

3,0<br />

3,0<br />

Partial safety factor (dry and wet concrete)<br />

1)<br />

γ Mp = γ Mc 1,8 2) 2,1 3)<br />

Partial safety factor (flooded bore hole)<br />

1)<br />

γ Mp = γ Mc 2,1 3)<br />

C30/37 1,04<br />

Increasing factors for<br />

concrete ψ c<br />

C40/50 1,<strong>08</strong><br />

C50/60 1,10<br />

Splitting failure<br />

Characteristic edge distance c cr,sp [mm]<br />

h≥2h ef<br />

1,0h ef<br />

2,0h ef >h>1,3h ef 5h ef – 2h<br />

h≤1,3h ef<br />

2,4h ef<br />

Characteristic spacing s cr,sp [mm] 2◦c cr,sp<br />

Partial safety factor (dry and wet concrete) γ Msp<br />

1)<br />

Partial safety factor (flooded bore hole)<br />

γ Msp<br />

1)<br />

1,8 2) 2,1 3)<br />

2,1 3)<br />

1) In absence of other national regulations<br />

2)<br />

The partial safety factor γ 2 = 1,2 is included.<br />

3)<br />

The partial safety factor γ 2 = 1,4 is included.<br />

4)<br />

Explanations see chapter 1.2<br />

5) Applications in flooded holes only until h ef = 12 d allowed<br />

<strong>Powers</strong> PURE150-PRO Injection resin with anchor rod for concrete<br />

Application with threaded rod<br />

Design method A:<br />

Characteristic values for tension loads in cracked concrete<br />

Annex 10<br />

of <strong><strong>Europe</strong>an</strong><br />

technical approval<br />

<strong>ETA</strong>-<strong>08</strong>/<strong>0376</strong>