PVC or PVC-PU Hose Hose Length - Rotec
PVC or PVC-PU Hose Hose Length - Rotec
PVC or PVC-PU Hose Hose Length - Rotec
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
a Water <strong>Hose</strong><br />
FORTIREX<br />
<strong>Hose</strong> Construction<br />
Flexible and sturdy hose having an off-white, rigid<br />
<strong>PVC</strong> spiral embedded in a light grey <strong>PVC</strong> wall.<br />
Applications<br />
F<strong>or</strong> suction and delivery of clean and dirty<br />
water, the drainage of sewers, conveying solid<br />
and abrasive materials and all other heavy duty<br />
industrial applications.<br />
It is used in agriculture with sprinkler irrigation<br />
equipment and tank-trucks; at docks f<strong>or</strong> discharging<br />
grain from the holds of ships; in the building<br />
industry f<strong>or</strong> cement powder silos.<br />
Temperature Range<br />
-10°C (+14°F) to +60°C (+140°F)<br />
IH35520025/50 25 4,6 1,0 150,0 10 3,0 450,0 30 0,57 160<br />
IH35520050/50 50 5,6 0,8 116,0 8 2,4 348,0 24 1,10 300<br />
IH35522063/50 63,5 6,0 0,8 116,0 8 2,4 348,0 24 1,55 370<br />
IH35520070/50 70 6,1 0,7 101,5 7 2,1 304,5 21 1,80 420<br />
IH35520080/50 80 6,4 0,7 101,5 7 2,1 304,5 21 2,10 480<br />
IH35522090/25 90 6,6 0,5 72,5 5 1,5 217,5 15 2,50 550<br />
IH35520100/25 100 7,2 0,5 72,5 5 1,5 217,5 15 3,30 630<br />
IH35520150/25 150 9,8 0,3 43,5 3 0,9 130,5 9 6,00 1100<br />
FORTIREX DIAM I.D. mm Parker ITR<br />
E16<br />
Suction and Delivery<br />
Suction<br />
≤ I.D. 50 mm: 0,80 bar (600 mm Hg)<br />
I.D. 63,5 - 100 mm: 0,70 bar (530 mm Hg)<br />
I.D. 150 mm: 0,55 bar (420 mm Hg)<br />
Tolerances<br />
On inside diameter:<br />
≤ I.D. 50 mm: ± 0,50 mm<br />
> I.D. 50 mm: ± 1,00 mm<br />
On wall thickness: ± 0,5 mm<br />
<strong>Length</strong> tolerance: ± 1%<br />
All other technical data are subject to a ± 5% tolerance.<br />
Burst Pressure<br />
Three times w<strong>or</strong>king pressure<br />
Note<br />
Available on request:<br />
- FORTIREX/ANC with an outer copper wire to ensure<br />
electrical continuity.<br />
W<strong>or</strong>king Burst<br />
Part Number /<br />
Pressure Pressure min. Bend<br />
Standard <strong>Length</strong> I.D. Wall Thickness Weight Radius<br />
Part Number m<br />
mm mm MPa psi bar MPa psi bar kg/m mm<br />
Catalogue 4401/UK