EDX Product Brochure - Evapco
EDX Product Brochure - Evapco
EDX Product Brochure - Evapco
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
OPTIONAL EQUIPMENT<br />
Single Side Inlet Connection<br />
The <strong>EDX</strong> is available with a Single Side Inlet option which eliminates<br />
external pipework, valves and field balancing associated<br />
with the standard (2) inlet design.<br />
Internal PVC pipework is utilized to relocate the water inlet to the<br />
side of each cell. The connection is standard with a hole and bolt<br />
circle pattern, other options are available. Note: Multiple cell<br />
installation will require adequate space between towers to allow<br />
for piping, unless the bottom inlet option is selected.<br />
If a tight, side by side layout is required, the <strong>EDX</strong> is available with<br />
an optional Bottom Inlet Connection. The inlet is located on the<br />
bottom of the cold water basin and allows the inlet pipework to<br />
run underneath the unit. Note: Adequate space is required<br />
underneath the unit for pipework. Please consult the factory for<br />
certified drawings indicating connection size and location.<br />
S<br />
K<br />
Model Static Single P Water Inlet* Water Outlet**<br />
No. Lift Inlet Height (Per Cell) (Per Cell)<br />
<strong>EDX</strong> 212-0122 17' 5” 8'-8-3/8” 11' 1” (1) 12” (1) 12”<br />
<strong>EDX</strong> 212-0222 23' 9-3/4” 14' 7-1/4” 11' 1” (1) 12” (1) 12”<br />
<strong>EDX</strong> 212-0322 19'- 4-1/2” 10' 8” 11' 1” (1) 12” (1) 12”<br />
<strong>EDX</strong> 212-0422 17' 5” 8' 8-3/8” 11' 1” (1) 12” (1) 12”<br />
<strong>EDX</strong> 212-0522 23' 9-3/4” 14' 7-1/4” 11' 1” (1) 12” (1) 12”<br />
<strong>EDX</strong> 212-0622 19' 4-1/2” 10' 8” 11' 1” (1) 12” (1) 12”<br />
<strong>EDX</strong> 212-0722 17' 5” 8' 8-3/8” 11' 1” (1) 12” (1) 12”<br />
<strong>EDX</strong> 212-0822 23' 9-3/4” 14' 7-/4” 11' 1” (1) 12” (1) 12”<br />
<strong>EDX</strong> 212-0922 19' 4-1/2” 10' 8” 11' 1” (1) 12” (1) 12”<br />
<strong>EDX</strong> 212-1022 23' 9-3/4” 14' 7-1/4” 11' 1” (1) 12” (1) 12”<br />
<strong>EDX</strong> 214-0124 17' 7-3/8” 8' 8-3/8” 12' 1” (1) 14” (1) 14”<br />
<strong>EDX</strong> 214-0224 19' 6-7/8” 10' 8” 12' 1” (1) 14” (1) 14”<br />
<strong>EDX</strong> 214-0324 17' 7-3/8” 8' 8-3/8” 12' 1” (1) 14” (1) 14”<br />
<strong>EDX</strong> 214-0424 19' 6-7/8” 10' 8” 12' 1” (1) 14” (1) 14”<br />
<strong>EDX</strong> 214-0524 17' 7-3/8” 8' 8-3/8” 12' 1” (1) 14” (1) 14”<br />
<strong>EDX</strong> 214-0624 19' 6-7/8” 10' 8” 12' 1” (1) 14” (1) 14”<br />
<strong>EDX</strong> 214-0724 17' 7-3/8” 8' 8-3/8” 12' 1” (1) 14” (1) 14”<br />
<strong>EDX</strong> 214-0824 24' 1/8” 14' 7-1/4” 12' 1” (1) 14” (1) 14”<br />
<strong>EDX</strong> 214-0924 19' 6-7/8” 10' 8” 12' 1” (1) 14” (1) 14”<br />
<strong>EDX</strong> 214-1024 17' 7-3/8” 8' 8-3/8” 12' 1” (1) 14” (1) 14”<br />
<strong>EDX</strong> 214-1124 19' 6-7/8” 10' 8” 12' 1” (1) 14” (1) 14”<br />
<strong>EDX</strong> 214-1224 24' 1/8” 14' 7-1/4” 12' 1” (1) 14” (1) 14”<br />
<strong>EDX</strong> 214-1324 24' 1/8” 14' 7-1/4” 12' 1” (1) 14” (1) 14”<br />
<strong>EDX</strong> 214-1424 19' 6-7/8” 10' 8” 12' 1” (1) 14” (1) 14”<br />
<strong>EDX</strong> 214-1524 24' 1/8” 14' 7-1/4” 12' 1” (1) 14” (1) 14”<br />
Notes:<br />
1. Use this chart for the pre-engineering phase of the project. Obtain factory certified drawings from your local EVAPCO representative or the factory.<br />
2. Pipework shown is provided by EVAPCO. Consult the factory certified drawings for dimensions.<br />
3. External pipework not shown must be provided by others and self-supported. Do not support pipework from the cooling tower.<br />
4. Note: The single inlet connection is located above the basin access door, position inlet piping properly to avoid blocking the door. Consult page 5 for<br />
dimensions of the unit.<br />
5. Consult the factory for optional bottom inlet connection.<br />
* Standard connection is hole and bolt circle design for 150# raised face flange.<br />
** Standard connection is Beveled for Weld and grooved for a mechanical coupling.<br />
Other Accessories/Optional Materials<br />
• Pony Motors<br />
• Bottom Sump Box<br />
• Gear Drive<br />
• Air Inlet Screens<br />
• Electric Water Level Controls and Level Indicators<br />
• Vibration Switch<br />
• Fan and Motor Davit<br />
• Flanged Connections<br />
• Flume Plate<br />
Models<br />
KW*<br />
<strong>EDX</strong> 212-0122 to 1022 (4) 12<br />
<strong>EDX</strong> 214-0124 to 1524 (4) 15<br />
Electric Pan Heaters<br />
9