Hilti <strong>HVZ</strong> – an anchor you can count on<br />

<strong>The</strong> first adhesive anchor with foil capsule suitable for use <strong>in</strong> <strong><strong>crack</strong>ed</strong> <strong>concrete</strong><br />

Go for safety.<br />

<strong>Re<strong>in</strong>forced</strong> <strong>concrete</strong> <strong>is</strong> <strong><strong>crack</strong>ed</strong> <strong>concrete</strong>.<br />

That’s why fasten<strong>in</strong>g systems for the<br />

tension zone of re<strong>in</strong>forced <strong>concrete</strong> must<br />

re-expand reliably if a <strong>crack</strong> forms. <strong>The</strong><br />

<strong>in</strong>novative adhesive anchor system Hilti<br />

<strong>HVZ</strong> unites pioneer<strong>in</strong>g expansion technology<br />

with the adhesive anchor<strong>in</strong>g pr<strong>in</strong>ciple<br />

that’s been tried and tested a million times<br />

over. Together, a robust, easy-to-use foil<br />

capsule of revolutionary design and a<br />

s<strong>in</strong>gle-part anchor rod provide the answer<br />

to unusually demand<strong>in</strong>g fasten<strong>in</strong>gs <strong>in</strong><br />

difficult conditions.<br />

Reliable: the application<br />

■ Cracked tension zone of <strong>concrete</strong><br />

components<br />

■ Dynamic load<strong>in</strong>g, such as fatigue,<br />

shock and se<strong>is</strong>mic<br />

■ Small edge d<strong>is</strong>tances and spac<strong>in</strong>g<br />

Reliable: the handl<strong>in</strong>g<br />

■ Quick and easy sett<strong>in</strong>g operation<br />

■ Accurate fasten<strong>in</strong>g design with Hilti<br />

software<br />

■ Insensitive to frequently made application<br />

errors, e.g. poor hole clean<strong>in</strong>g<br />

Reliable: the performance<br />

■ Automatic follow-up expansion if<br />

<strong>crack</strong>s form<br />

■ High load<strong>in</strong>g res<strong>is</strong>tance, even <strong>in</strong><br />

<strong><strong>crack</strong>ed</strong> <strong>concrete</strong> or when edge<br />

d<strong>is</strong>tance and spac<strong>in</strong>g are small<br />

■ Rods <strong>in</strong> various grades of steel and<br />

sizes for a wide variety of applications<br />

ALLGEMEIN<br />

BAUAUFSICHTLICH<br />

Protezione civile<br />

ZUGELASSEN<br />

Zivilschutz<br />

Protection civile<br />

Protecziun civila<br />

Inspected, tested and approved<br />

<strong>The</strong> anchor system reliable under shock<br />

load<strong>in</strong>g.<br />

In a <strong>crack</strong><br />

Multiple tapers and special surface<br />

for reliable follow-up<br />

expansion <strong>in</strong> a <strong>crack</strong><br />

Optim<strong>is</strong>ed and tested for fatigue properties under dynamic<br />

load<strong>in</strong>g.<br />

Cutt<strong>in</strong>g edge<br />

Innovative cutt<strong>in</strong>g edge geometry<br />

and multifunctional helical<br />

taper for optim<strong>is</strong>ed mix<strong>in</strong>g and<br />

d<strong>is</strong>tribution of the adhesive<br />

Mark of confidence<br />

End-face mark<strong>in</strong>g for clear <strong>in</strong>-situ identification<br />

of the anchor:<br />

Quick sett<strong>in</strong>g thanks to hexagon drive<br />

and TE-C HEX sett<strong>in</strong>g tool (Simply<br />

attach, drive <strong>in</strong> and remove.)<br />

Hilti safety programme<br />

HAS-TZ steel grade 8.8, galvan<strong>is</strong>ed for use <strong>in</strong> dry <strong>in</strong>side rooms,<br />

to 10 microns suitable for dynamic load<strong>in</strong>g<br />

HAS-RTZ sta<strong>in</strong>less steel grade A4-80 for use outside and <strong>in</strong> damp<br />

DIN 1.4401 rooms<br />

HAS-HCR-TZ highly corrosion res<strong>is</strong>tant for highly corrosive and aggresspecial<br />

steel (HCR) sive surround<strong>in</strong>gs (i.e. tunnels,<br />

DIN 1.4529 <strong>in</strong>door swimm<strong>in</strong>g pools, etc)<br />

Use <strong>in</strong> tunnels<br />

It’s uncerta<strong>in</strong> where <strong>crack</strong>s might appear. It’s certa<strong>in</strong> that the Hilti<br />

<strong>HVZ</strong> system will hold, even <strong>in</strong> a <strong>crack</strong>.<br />

An anchor rod for corrosive surround<strong>in</strong>gs, the Hilti HAS-HCR-TZ <strong>is</strong><br />

made of highly corrosion res<strong>is</strong>tant steel.<br />

Fire <strong>in</strong> tunnels<br />

Temperature (°C)<br />

1200<br />

1000<br />

500<br />

■ Tunnel Fire<br />

Curve (RABT)<br />

■ Int. Standard Temperature<br />

Curve (ISO 834)<br />

0 30 60 90 120 150 180<br />

Time (m<strong>in</strong>)<br />

Responsibility for safety: the Hilti <strong>HVZ</strong> <strong>is</strong> the first anchor system<br />

tested <strong>in</strong> tunnel fire conditions