<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F<br />
<strong>Electronic</strong> <strong>lock</strong> MIFARE ®<br />
Application<br />
The <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F is the ideal solution for the convenient electronic<br />
<strong>lock</strong>ing of wardrobe <strong>lock</strong>ers in fitness clubs, baths, golf resorts, and other<br />
individual <strong>com</strong>pany applications such as safes. The identification at the<br />
<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F is carried out via contactless RFID data carriers (Radio<br />
Frequency Identification). The <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F is suitable for any kind<br />
of <strong>lock</strong>er material (steel sheets, wood, HPL, fully synthetic materials, or<br />
glass) and is useable for doors that open to the left or right. The various<br />
operating modes enable the rather flexible use of these <strong>lock</strong>s.<br />
Function description<br />
<strong>Lock</strong>ers can be electronically <strong>lock</strong>ed and opened via contactless data<br />
carriers with the <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F. The user presses the door shut and<br />
holds the data carrier up to the reader centre that is mounted on the door.<br />
The <strong>lock</strong>ing of the door is signalled by an LED. The <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F is<br />
connected to the <strong>GAT</strong> <strong>Lock</strong> Controller <strong>5010</strong> FX unit (up to 16 <strong>lock</strong>s per<br />
control unit).<br />
Further functionalities:<br />
• Online and offline operation<br />
• Burglary attempt surveillance<br />
• Remote opening via central <strong>com</strong>puter<br />
• Free and personal <strong>lock</strong>er selection<br />
• Selectable operating mode<br />
• Reliable data transmission between the reader and data carrier<br />
• Easy retrofitting of <strong>lock</strong>ers already in place<br />
• Automatic night opening<br />
Order information<br />
Description<br />
<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F<br />
<strong>Electronic</strong> <strong>lock</strong>er <strong>lock</strong> for MIFARE ® data carriers<br />
Accessories<br />
Description<br />
<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> - Mounting instruction NE<br />
Mounting instruction for non-metallic doors (english)<br />
<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> - Mounting instruction ME<br />
Mounting instruction for metallic doors (english)<br />
Front Label <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> R<br />
Self-adhesive front label, without <strong>lock</strong>er number, for<br />
right-side mounted doors<br />
PartNo.<br />
452983<br />
PartNo.<br />
398487<br />
398386<br />
674989<br />
Front Label <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> L<br />
Self-adhesive front label, without <strong>lock</strong>er number, for<br />
left-side mounted doors<br />
675081<br />
Front Label <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> BED<br />
Self-adhesive front label with operating instructions<br />
675182<br />
<strong>GAT</strong> <strong>Lock</strong> Booster 5000<br />
Booster module for installation of the <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F<br />
in <strong>lock</strong>er with metal doors<br />
689730<br />
<strong>GAT</strong> <strong>Lock</strong> Booster 5100<br />
Booster module (self-adhesive label) for metallic doors<br />
488083<br />
<strong>GAT</strong> <strong>Lock</strong> Bolt Set 5011<br />
Package with door bolt, rubber and installation material<br />
241575<br />
<strong>GAT</strong> <strong>Lock</strong> Conroller <strong>5010</strong> FX<br />
Control unit for <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F<br />
501372<br />
<strong>GAT</strong> <strong>Lock</strong> Ex Cord <strong>5010</strong><br />
Extension cable (2 m) for <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F<br />
295584<br />
www.<strong>gantner</strong>.<strong>com</strong><br />
Valid as from October 10 th • Technical data subject to modifications without notice!<br />
DB_<strong>GAT</strong>-LOCK<strong>5010</strong>F_EN_22.indd • Art.Nr.: 808281<br />
1
Technische Daten<br />
Nominal voltage:<br />
Current consumption:<br />
Reader type: MIFARE ®<br />
Frequency of reader field:<br />
Range of read field:<br />
Display element:<br />
Connection:<br />
18 VDC (SELV - safety extre-low<br />
voltage) from <strong>GAT</strong> <strong>Lock</strong> Controller<br />
<strong>5010</strong> FX<br />
max. 2 A for 300 ms<br />
13.56 MHz<br />
10 to 50 mm, according to the<br />
installation situation and data carrier,<br />
for all data carriers, except the card<br />
<strong>GAT</strong> Chip Card 200 F, the <strong>GAT</strong><br />
Booster 5100 has to be used<br />
LED (red) for status display<br />
shielded cable with 3-pole jack plug<br />
Connection cable length:<br />
Housing material:<br />
Bolt material:<br />
Dimensions:<br />
Permitted ambient temperature:<br />
Standard 4 m, max. length 6 m (with<br />
2 m cable extension)<br />
Polycarbonate<br />
Steel<br />
Protection type: IP 52<br />
Protection class:<br />
Weight:<br />
Environment class<br />
based on VDS 2110:<br />
140 x 112 x 28 mm<br />
0 to +60°C<br />
III<br />
0.4 kg<br />
II (conditions in indoor areas)<br />
Dimensions<br />
4 4<br />
5<br />
3<br />
2<br />
1 6<br />
7<br />
1<br />
5<br />
5<br />
1<br />
38,5 mm<br />
99,5 mm<br />
112 mm<br />
1. Fixing holes<br />
2. Potentiometer for antenna adjustment<br />
3. Transport security tab<br />
4. Connection cable<br />
5. mounting plate, spacer and door bolt<br />
6. Status display (red LED)<br />
7. mounting side<br />
20 mm<br />
4<br />
140 mm<br />
7<br />
14 mm<br />
28 mm<br />
10 mm<br />
18 mm<br />
Typical application<br />
Power supply<br />
<strong>GAT</strong> <strong>Lock</strong> Controller <strong>5010</strong> FX<br />
Network<br />
Row of <strong>lock</strong>ers<br />
Front label<br />
Door bolt<br />
<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F<br />
Valid as from October 10 th • Technical data subject to modifications without notice!<br />
2 DB_<strong>GAT</strong>-LOCK<strong>5010</strong>F_EN_22.indd • Art.Nr.: 808281<br />
www.<strong>gantner</strong>.<strong>com</strong>
Mounting and installation instructions<br />
The <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F is mounted on the lateral surface of the <strong>lock</strong>er<br />
body by means of 3 screws. The door bolt is mounted on the inside of<br />
the <strong>lock</strong>er door by means of the mounting plate and spacer. Observe the<br />
installation instructions in the corresponding mounting instructions of the<br />
<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F.<br />
Door opening<br />
There are doors that can open to the right or left. For left-side mounted<br />
doors, the <strong>lock</strong> is mounted rotated 180° (status display is at the bottom).<br />
right-side mounted door:<br />
left-side mounted door:<br />
<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F<br />
<strong>Lock</strong>er<br />
<strong>Lock</strong>er<br />
<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F<br />
98,0 mm<br />
54,0 mm<br />
1<br />
3<br />
Ø 12,0 mm<br />
Ø 5,1 mm<br />
2<br />
1<br />
26 mm<br />
51 mm<br />
69 mm<br />
99,5 mm<br />
Door bolt, mounting<br />
plate and spacer<br />
<strong>Lock</strong>er door<br />
Status display<br />
Centre of reading field<br />
<strong>Lock</strong>er door<br />
Centre of reading field<br />
Status display<br />
Door bolt, mounting<br />
plate and spacer<br />
12,0 mm<br />
Range of read field<br />
Drill a hole of Ø 6 mm into the door for the status display (1). The centre of<br />
the reader field (2) is located between the door bolt and status display.<br />
A minimum distance of 200 mm must be observed between two<br />
adjacent <strong>GAT</strong> <strong>Lock</strong>s <strong>5010</strong> F. Otherwise, mutual interference might c<strong>au</strong>se<br />
identification malfunctions.<br />
Remove the transport security tab (3) only after the mounting is<br />
<strong>com</strong>plete!<br />
<strong>Lock</strong>er door<br />
46,0 mm<br />
114,0 mm<br />
<strong>Lock</strong>er wall<br />
<strong>Lock</strong> offset and door gap:<br />
Cushion<br />
<strong>Lock</strong>er wall<br />
14 mm<br />
<strong>Lock</strong>er door<br />
Door bolt<br />
The door bolt is mounted on the inside of the <strong>lock</strong>er door by means of the<br />
mounting plate and spacer. The rubber washer guides the bolt.<br />
For the marking of the bolt position on the <strong>lock</strong>er door, the use of the <strong>GAT</strong><br />
<strong>Lock</strong> Tool 5982 is re<strong>com</strong>mended (refer to the ordering instructions). The<br />
marking and mounting of the bolts should be performed after the <strong>lock</strong>ers<br />
have been aligned at their final installation site.<br />
1 2 3 4<br />
1. Door bolt<br />
2. Rubber washer<br />
3. Mounting plate<br />
4. Spacer<br />
<strong>Lock</strong> offset<br />
Door gap<br />
<strong>Lock</strong>er door<br />
1<br />
Select the appropriate fastening screws for the mounting plate and spacer<br />
depending on the door material and thickness. Always use countersunk<br />
head screws, as the heads must not protrude above the surface of the<br />
mounting plate.<br />
4,4 mm<br />
6 mm<br />
Screw<br />
Mounting plate<br />
Screw<br />
Mounting plate<br />
<strong>Lock</strong>er wall<br />
The door bolt must be fully inside the <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F (1) when the<br />
<strong>lock</strong>er door is closed. Please observe the following interrelation of the<br />
<strong>lock</strong> offset and the door gap.<br />
<strong>Lock</strong> offset (mm)<br />
6<br />
Metal doors<br />
For metal doors, the <strong>GAT</strong> <strong>Lock</strong> Booster 5000 must be used (refer to the<br />
<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> mounting instructions MD).<br />
<strong>GAT</strong> <strong>Lock</strong> Booster 5000<br />
<strong>GAT</strong> <strong>Lock</strong> Booster 5000<br />
5<br />
4<br />
3<br />
2<br />
1<br />
0<br />
0 1 2 3 4 5 6 Door gap (mm)<br />
As the <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F is suitable for very diverse installation conditions,<br />
always perform a test installation on just one <strong>lock</strong>er of the system prior to<br />
the <strong>com</strong>plete installation of subsequent <strong>lock</strong>ers.<br />
www.<strong>gantner</strong>.<strong>com</strong><br />
<strong>Lock</strong>er door<br />
<strong>Lock</strong>er wall<br />
Valid as from October 10 th • Technical data subject to modifications without notice!<br />
DB_<strong>GAT</strong>-LOCK<strong>5010</strong>F_EN_22.indd • Art.Nr.: 808281<br />
<strong>Lock</strong>er wall<br />
<strong>Lock</strong>er wall<br />
3
<strong>Electronic</strong> connection<br />
Direct connection to the <strong>GAT</strong> <strong>Lock</strong> Controller <strong>5010</strong> FX<br />
<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F<br />
<strong>GAT</strong> <strong>Lock</strong> Controller <strong>5010</strong> FX<br />
HF - (Shield)<br />
LED (Black)<br />
HF + (White)<br />
1 2 3<br />
Cable conduit<br />
3-pole jack plug<br />
Strain relief<br />
Connection cable 4 m<br />
Use of a 2 m extension cable<br />
<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> F<br />
Max. one cable extension (2 m)<br />
<strong>GAT</strong> <strong>Lock</strong> Ex Cord <strong>5010</strong><br />
HF - (Shield)<br />
LED (Black)<br />
HF + (White)<br />
1 2 3<br />
Connection cable (4 m)<br />
Connection cable<br />
Type: LiYCY, 2 wires, shielded, Ø 5.5 mm, length 4 m<br />
A maximum of one 2 m extension cord (<strong>GAT</strong> <strong>Lock</strong> Ex Cord <strong>5010</strong>, article<br />
number: 295584) per <strong>lock</strong> may be used. Maximum cable length: 6 m.<br />
Mount the connection cable directly to the upper side of the <strong>lock</strong>er.<br />
Strain relief<br />
The connection cable must be installed in the cable channel on the<br />
installation side of the <strong>lock</strong>.<br />
Safety instructions<br />
- This device must be installed by qualified personnel only.<br />
- The applicable safety and accident prevention regulations<br />
must be observed.<br />
- Safety devices must not be removed.<br />
- Please observe the technical data of the device specified<br />
on the data sheet.<br />
- The device must be disconnected from the power supply<br />
prior to installation, assembly or dismantling.<br />
Valid as from October 10 th • Technical data subject to modifications without notice!<br />
4 DB_<strong>GAT</strong>-LOCK<strong>5010</strong>F_EN_22.indd • Art.Nr.: 808281<br />
www.<strong>gantner</strong>.<strong>com</strong>