<strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong><strong>Control</strong> <strong>unit</strong> <strong>for</strong> <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> B LEGIC ®ApplicationThe <strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong> is used <strong>for</strong> controlling the <strong>GAT</strong> <strong>Lock</strong><strong>5010</strong> B (LEGIC ® ). The locks are directly connected to the <strong>GAT</strong> <strong>Lock</strong><strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong> (up to 16 <strong>unit</strong>s) and can be individually configured.The control <strong>unit</strong> can be operated in online mode (via a PC/server) or inoffline mode (<strong>au</strong>tonomously).Function descriptionThe <strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong> is connected to a PC/server via a serialRS 485 network. In online operation, the control <strong>unit</strong> captures the data carrier,which is read at the lock, and <strong>for</strong>wards the in<strong>for</strong>mation to the PC/server<strong>for</strong> the verification of credentials. The current status of the locking systemis also <strong>for</strong>warded to the PC/server, enabling the visualisation of the systemstatus (<strong>for</strong> example, with <strong>GAT</strong> <strong>Lock</strong> Administration). In offline operation,the control <strong>unit</strong> <strong>au</strong>tonomously per<strong>for</strong>ms the verification of credentials. Thevisualisation of the system status is also possible in offline operation.Further functionalities:• Up to 16 <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> B may be connected• Up to 254 <strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong>s <strong>5010</strong> <strong>BX</strong> in a network• Up to 4,000 lockers in a network• LED status display• Remote opening via a central <strong>unit</strong>• Reliable data transmission of the data carrier• Emergency operationOrder in<strong>for</strong>mationDescription<strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong><strong>Control</strong> <strong>unit</strong> <strong>for</strong> the LEGIC ® locker lock <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> BAccessoriesDescription<strong>GAT</strong> Patch Cable 5805Bus cable (5 m) with 8-pole RJ 45 plugPower Connection Cable EUMains cable (length 2.5 m) with EU plugPower Connection Cable AUSMains cable (length 2.5 m) with plug <strong>for</strong> AustraliaPartNo.432981PartNo.909321495624402877Power Connection Cable UKMains cable (length 2.5 m) with plug <strong>for</strong> Great Britain499022<strong>GAT</strong> <strong>Lock</strong> Ex Cord <strong>5010</strong>Extension cable (2 m) to the <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> B295584<strong>GAT</strong> <strong>Lock</strong> Basic Set 5011 BPackage with 3 LEGIC ® master data carriers andinstallation instructions241474Installation Kit SP010-SP014-SP020-LC<strong>5010</strong>Wall mounting and mounting material498286<strong>GAT</strong> <strong>Lock</strong> Administration 1 - 15Software (Windows ® ) <strong>for</strong> configuration and control of the<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong>. Licence <strong>for</strong> up to 15 control <strong>unit</strong>s662116<strong>GAT</strong> <strong>Lock</strong> Administration 16 - 250Software (Windows ® ) <strong>for</strong> configuration and control of the<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong>. Licence <strong>for</strong> up to 250 control <strong>unit</strong>s.945119www.<strong>gantner</strong>.<strong>com</strong>Valid as from October 9 th • Technical data subject to modifications without notice!DB_<strong>GAT</strong>-LOCKCONT<strong>5010</strong>B_EN_16.indd • Art.Nr.: 8081801


Technical DataNominal voltage:Permitted input voltage:Frequency:Aver. power consumption:230/115 VAC207 to 253 / 103.5 to 126.5 VAC50/60 Hz15 VAReader type: LEGIC ®Adress range: 1 to 254<strong>GAT</strong> <strong>Lock</strong> Network:Interface <strong>GAT</strong> <strong>Lock</strong> Network: 2 x RS 485Number of locks: max. 16Offline: max. 50 <strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong><strong>5010</strong> <strong>BX</strong> per PC/Server-InterfaceOnline: max. 8 <strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong><strong>5010</strong> <strong>BX</strong> per PC/Server-InterfaceConnections: - <strong>GAT</strong> <strong>Lock</strong> Network (RS 485): RJ 45- <strong>Lock</strong>s: jack, 3.5 mm, 3-pole- Supply: IEC power plugHousing material:Dimensions:Permitted ambient temperature:Protection type: IP 52Protection class:Weight:Environment classbased on VDS 2110:Plastic (PC-ABS), halogen free246 x 193 x 62 mm0 to +60°CI1,8 kgII (conditions in indoor areas)Dimensions2132193 mm1. Status displays (3 LEDs)2. Screws <strong>for</strong> closing the housing3. Mechanical lock4. Cable entry points61,7 mm4244 mm248 mmTypical applicationPower supplyNetwork (RS 485)<strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong><strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong>16 x 16 xRow of lockers with<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> BValid as from October 9 th • Technical data subject to modifications without notice!2 DB_<strong>GAT</strong>-LOCKCONT<strong>5010</strong>B_EN_16.indd • Art.Nr.: 808180www.<strong>gantner</strong>.<strong>com</strong>


Mounting and installation instructionsThe <strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong> should ideally be placed so as to allowthe connection of the controlled locks without additional extension cords(Re<strong>com</strong>mendation: Placement in or on top of the row of lockers).Wall mountingFor the wall mounting of the <strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong>, an optionalinstallation kit with a matching wall mounting is available (refer to theordering instructions).Space requirementWhen placing the <strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong> <strong>unit</strong>, make sure that thereis sufficient space <strong>for</strong> opening and closing the cover of the control <strong>unit</strong>,as well as <strong>for</strong> inserting the cables via the front cover (1). The indicatedminimum distances must be observed.215 mm135 mm 193 mm50 mm<strong>Lock</strong>ing of the <strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong>s <strong>5010</strong> <strong>BX</strong>After the installation and connection of the wires, the cover of the <strong>GAT</strong><strong>Lock</strong> <strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong> is locked.1. 2.3.Notices:1. Close the cover.2. Fasten the cover with the two screws that are included.3. <strong>Lock</strong> the <strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong> additionally with the mechanicalkey. Store the key in a safe place.www.<strong>gantner</strong>.<strong>com</strong>Valid as from October 9 th • Technical data subject to modifications without notice!DB_<strong>GAT</strong>-LOCKCONT<strong>5010</strong>B_EN_16.indd • Art.Nr.: 8081803


Electrical connectionTCP/IP Network over COM-Server<strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong>2 4 6 8 10 12 14 16Mains power<strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong>2 4 6 8 10 12 14 16Mains power1 3 5 7 9 11 13 151 3 5 7 9 11 13 15Jack plug3-poleRJ 45RJ 45COM-ServerMains powerTCP/IPto PC/ServerRS 485RS 485RS 485<strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> B1 2 3Serial RS 485 NetworkHF - (Shield)LED (Black)HF + (White)12 14 16Mains power11 13 15Interface converterISK 200Mains powerRJ 45RS 232to PC/ServerRS 485RS 485NetworkRS 485 bus connection via RJ 45 jacks.Offline: Up to 50 <strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong>s <strong>5010</strong> <strong>BX</strong> can be connected to aserver/PC interface.Online: Up to 8 <strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong>s <strong>5010</strong> <strong>BX</strong> can be connected to aserver/PC interface.Connection of a <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> BA maximum of 16 <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> B per <strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong>.Use the original <strong>GAT</strong> <strong>Lock</strong> <strong>5010</strong> B cables. Do not use more than one 2 m<strong>GAT</strong> <strong>Lock</strong> Ex Cord <strong>5010</strong> per lock!Power supplyPower connection over IEC power plugs (refer to the technical data). Every<strong>GAT</strong> <strong>Lock</strong> <strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong> requires an individual power outlet.In order to cover potential power outages, an emergency power supply isre<strong>com</strong>mended. The EPS/UPS must be designed <strong>for</strong> 15 VA per <strong>GAT</strong> <strong>Lock</strong><strong><strong>Control</strong>ler</strong> <strong>5010</strong> <strong>BX</strong> and <strong>for</strong> 30 minutes.Re<strong>com</strong>mended cablesRS 485: min. CAT 5 (STP), maximum cable length per line 1,200 m.Safety instructions- This device must be installed by qualified personnel only.- The applicable safety and accident prevention regulationsmust be observed.- Safety devices must not be removed.- Please observe the technical data of the device specifiedon the data sheet.- The device must be disconnected from the power supplyprior to installation, assembly or dismantling.Valid as from October 9 th • Technical data subject to modifications without notice!4 DB_<strong>GAT</strong>-LOCKCONT<strong>5010</strong>B_EN_16.indd • Art.Nr.: 808180www.<strong>gantner</strong>.<strong>com</strong>