Report #UCR P5421, P5505, P5568, P5534 Botanical Gardens<br />
Report<br />
Name<br />
Item/Location<br />
Barrier<br />
(noted feature, item or area does not meet the<br />
new construction criteria detailed below)<br />
Action Priority Target<br />
Date<br />
Estimated<br />
Cost<br />
Interim<br />
Solution<br />
Action<br />
Completion<br />
Date<br />
UCR<br />
P5421,<br />
P5505,<br />
P5568,<br />
P5534<br />
Botanical<br />
Gardens<br />
11-Accessories:<br />
Women's Restroom at<br />
Botanical Gardens.<br />
40" maximum height to bottom of reflective<br />
surface of mirror. Mirrors not located above<br />
lavatories or counters are required to measure<br />
no greater than 35" above the finished floor. 40"<br />
max. height to all other fixtures (i.e., soap<br />
dispensers, towels, toilet seat covers, auto<br />
dryers, sanitary napkins, waste recepatacles,<br />
etc.). Coat hooks and shelving are located<br />
within appropriate reach ranges (48" max.<br />
height above floor surface is recommended).<br />
Lower mirror. Install accessible<br />
coat hook. Lower the paper<br />
towel dispenser. Lower the<br />
soap dispenser.<br />
3 $490.00<br />
UCR<br />
P5421,<br />
P5505,<br />
P5568,<br />
P5534<br />
Botanical<br />
Gardens<br />
UCR<br />
P5421,<br />
P5505,<br />
P5568,<br />
P5534<br />
Botanical<br />
Gardens<br />
12-Water Fountains<br />
(Drinking): Next to the<br />
Men's Restroom at<br />
Botanical Gardens.<br />
13-Doors: Men's<br />
Restroom at Botanical<br />
Gardens.<br />
32" minimum wide and 18" minimum deep<br />
alcove provided. 18" - 19" depth of fountain. 27"<br />
high x 8" deep clear knee space under fountain.<br />
9" high x 17" deep toe clearance. Bubbler outlet<br />
is 36" maximum from floor. 4" minimum height<br />
of stream. Two fountains are provided, one that<br />
is wheelchair accessible and one at normal<br />
height for those persons having difficulty<br />
bending or stooping.<br />
1/4" maximum vertical threshold or 1/2" beveled<br />
at 1:2. 5 lb. maximum pressure to operate<br />
exterior doors.<br />
Install new HI-LO drinking<br />
fountain. Install canedetectable<br />
barrier around<br />
fountain.<br />
Install level exterior door<br />
landing. Adjust door opening<br />
pressure / closing time unless<br />
accepted by DSA Fire / Life<br />
Safety. Consider issues<br />
connected with building<br />
pressure / climate control.<br />
2 $8,149.34 Defer.<br />
2 $1,531.57<br />
UCR<br />
P5421,<br />
P5505,<br />
P5568,<br />
P5534<br />
Botanical<br />
Gardens<br />
14-Clear Space at<br />
Doors: Men's Restroom<br />
at Botanical Gardens.<br />
Floor or landing is level and clear (2% max.<br />
slope). 60" min. clear space in direction of door<br />
swing.<br />
Install automatic door opening<br />
device.<br />
2 $6,489.45<br />
6/6/2012 Page 3 of 7