pdf, 1775 Kbytes
pdf, 1775 Kbytes
pdf, 1775 Kbytes
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
ANALYTICAL VOLUMETRIC SOLUTIONS<br />
READY TO USE AQUEOUS SOLUTIONS (CONTINUED)<br />
Product No. Description normality Molarity Pack Size<br />
SUB205010 Sulphuric Acid 1.0N 0.5M 10L<br />
SU20505<br />
5L<br />
SU20501<br />
1L<br />
SU203195 Sulphuric Acid 0.638N 0.319M 5L<br />
SU203191<br />
1L<br />
SUB202510 Sulphuric Acid 0.5N 0.25M 10L<br />
SU20255<br />
5L<br />
SU20251<br />
1L<br />
SU20135 Sulphuric Acid 0.26N 0.13M 5L<br />
SU20131<br />
1L<br />
SU2012755 Sulphuric Acid 0.255N 0.1275M 5L<br />
SU2012751<br />
1L<br />
SU20105 Sulphuric Acid 0.2N 0.1M 5L<br />
SU20101<br />
1L<br />
SU20055 Sulphuric Acid 0.1N 0.05M 5L<br />
SU20051<br />
1L<br />
SU20015 Sulphuric Acid 0.02N 0.01M 5L<br />
SU20011<br />
1L<br />
SU2004165 Sulphuric Acid 0.0832N 0.0416M 5L<br />
SU2004161<br />
1L<br />
ZNCL20105 Zinc Chloride 0.1N 0.1M 5L<br />
ZNCL20101<br />
1L<br />
ZNCL20505 Zinc Chloride 0.5N 0.5M 5L<br />
ZNCL20501<br />
1L<br />
ZNSO00505 Zinc Sulphate 0.05N 0.05M 5L<br />
ZNSO00501<br />
1L<br />
ZNSO0105 Zinc Sulphate 0.1N 0.1M 5L<br />
ZS011<br />
1L<br />
REAGENTS EXPRESSED IN UNITS OF MOLARITY<br />
(NORMALITY), SPECIFIC GRAVITY AND PERCENTAGE (v/v,<br />
w/v, w/w) WHICH ARE NOT LISTED IN CATALOGUE ARE<br />
ALSO AVAILABLE. SEE PAGE 4 (CUSTOMISED REAGENTS)<br />
TO REQUEST QUOTATION.<br />
Certificate of Analysis<br />
Analytical Volumetric Solution<br />
Silver Nitrate 0.1M (0.1N)<br />
Product No:<br />
N20100F<br />
Lot No:<br />
N2010010L1<br />
Expiry date: 28/11/2012<br />
Mean measured value :<br />
0.0999 M<br />
Date of measurement: 03/12/2010<br />
Specification:<br />
0.0998 -0.1002M<br />
Method:<br />
Tested by potentiometric titration, to in-house method TPAGNO. Reagecon Diagnostics<br />
Ltd. is accredited by the Irish National Accreditation Board, under scope 264T, for the<br />
test method ,TPAGNO, used in the determination of this product.<br />
Traceability:<br />
This volumetric solution was checked by means of Sodium Chloride Analytical<br />
Volumetric Standard. This volumetric standard is directly traceable to a Standard<br />
Reference Material of National Institute of Standards and Technology (USA), 919b<br />
Sodium Chloride. All raw materials used to prepare this product are of high purity.<br />
This certificate relates solely to the lot number given above. The uncertainty of<br />
measurement has been calculated not to exceed ± 0.2% at 95% confidence level, ie.<br />
coverage factor k =2<br />
Products are manufactured under an NSAI registered I.S EN ISO9001:2008 Quality System, registration no: 19.2769<br />
Date of issue of the certificate: 03/12/2010<br />
Q.A. Officer Rosemary Coney<br />
Complementary information relative to this product is available at www.reagecon.com<br />
Page 1 of 1.This Certificate must not be reproduced except in full. Rev-10M1<br />
Reagecon Diagnostics Ltd.<br />
Shannon Free Zone, Shannon, Co. Clare, Ireland.<br />
Tel +353 61 472622, Fax: +353 61 472642<br />
Email: sales@reagecon.ie, www.reagecon.com<br />
www.reagecon.com<br />
Reagecon - Delivering the correct result<br />