HBC SERIES<br />

HBC Power Connector<br />

• Contact technology guarantees high reliability<br />

• Push lock to mate connector<br />

• Quick release latch to unmate<br />

• Ruggedised metal and plastic versions available<br />

• Cable and panel mount variants<br />

• Compact ergonomic design<br />

• Low component count<br />

• Gender reversible<br />

• Polarised<br />

• 360 degree EMI/RFI shielding option<br />

• 2000+ mating cycles without EMI/RFI band<br />

• Sealed IP67 when mated<br />

• Finger protected contacts<br />

• Current rating 300A and 500A<br />

• Temperature rating -20 to +125°C<br />

1. Ordering information for HBC range connectors<br />

1.1. Connector order code<br />

The order code is a sixteen character code that defines all standard connector options in the range.<br />

Series<br />

HBC 030 P A 1 A * A A 000<br />

HBC High Power Industrial<br />

000<br />

00E<br />

Current Rating<br />

0C0<br />

030<br />

050<br />

P<br />

R<br />

300 Amp<br />

500 Amp<br />

Shell Gender<br />

Plug<br />

Receptacle<br />

Shell Polarising<br />

A<br />

B<br />

C<br />

Shell Body Material (High Strength)<br />

1<br />

B<br />

Polarised Code A, contact cap Black<br />

Polarised Code B, contact cap Orange<br />

Polarised Code C, contact cap Blue<br />

Thermoplastic, Black<br />

Aluminium alloy, electroless Nickel plated<br />

Standard Variations<br />

0J0<br />

0M0<br />

0N0<br />

No variant<br />

EMI band fitted (metal plugs only)<br />

Rear mount metal receptacle with<br />

conductive panel o-ring<br />

Front mount plastic receptacle with<br />

non-conductive panel gasket<br />

Front mount metal receptacle with<br />

conductive panel o-ring (not available with<br />

backshell option B)<br />

Front mount metal receptacle with<br />

non-conductive panel o-ring (not available<br />

with backshell option B)<br />

Backshell exit code - see illustrations<br />

0<br />

other<br />

codes<br />

No backshell or metal connector<br />

See Backshell code table (section 1.3)<br />

Backshell Style<br />

Contact Gender<br />

A<br />

B<br />

Contact Termination<br />

*<br />

L<br />

Pin, Gold Plated<br />

Socket, Gold Plated<br />

Contact to accept cable crimped directly<br />

on contact axis. Customer must supply<br />

cable data when ordering.<br />

Contact to accept bolted termination e.g.<br />

lugged cable (lug ordered separately) or<br />

busbar. Also order this option for a plug<br />

with right angle backshell.<br />

0<br />

A<br />

B<br />

C<br />

No backshell<br />

Right-angle backshell (plug only). Must be<br />

used with HBB-950 Series lug, ordered<br />

separately.<br />

Straight backshell (metal versions only)<br />

Plastic receptacle to accept boot<br />

Note: plug connectors supplied without<br />

backshells are designed to accept lipped<br />

heat shrink boots<br />

V.5_11 P.1


HBC SERIES<br />

4. Panel preparations and connector outline drawings<br />

4.1. Panel preparation for receptacles<br />

4.1.1. Standard rear mount (connector mounted behind panel / inside box)<br />

300 Amp - Metal<br />

300 Amp - Plastic<br />

500 Amp - Metal<br />

500 Amp - Plastic<br />

4.1.2. Outer mounting (connector mounted in front of panel / outside box)<br />

300 Amp - Metal & Plastic 500 Amp - Metal & Plastic<br />

30,0<br />

29,0<br />

Maximum panel thickness 5.0mm. If panel is more than 3.0mm thick then fixing screws will need to be recessed to give clearance for mating connector<br />

V.5_11 P.2


HBC SERIES<br />

4.2. Connector outline drawings<br />

4.2.1. 300 amp plastic plug – HBC030P*1*******<br />

74<br />

53 (FOR LUG)<br />

LUG TERMINATION<br />

M8 X 1,25 X 15,0 DEEP<br />

SCREW & WASHER SUPPLIED<br />

WITH BACKSHELL VARIANT ONLY<br />

78,8 (FOR CRIMP)<br />

Ø37,5<br />

Ø15 FOR LUG<br />

OUTLINE OF<br />

BACKSHELL<br />

(IF FITTED)<br />

36<br />

55<br />

Ø27,4<br />

4.2.2. 300 amp plastic receptacle – HBC030R*1*******<br />

42,5 (CRIMP)<br />

29,36<br />

25,1 (FOR LUG 90° BOOT VARIANT)<br />

Ø3,2<br />

16,3 (FOR LUG NO BOOT)<br />

BOOT VARIANTS ONLY<br />

HBB030R*1**CO***<br />

29,36<br />

38,5<br />

Ø24<br />

LUG TERMINATION<br />

M8 X 1,25 X 15,0 DEEP<br />

OR<br />

CRIMP TERMINATION<br />

6<br />

Ø15 (FOR LUG)<br />

38,5<br />

34<br />

14<br />

V.5_11 Diagrams are not to scale. All dimensions are in mm. Transit caps not shown<br />

P.3


HBC SERIES<br />

4.2. Connector outline drawings<br />

4.2.3. 300 amp metal plug – HBC030P*(A or B)*******<br />

84 (90° BACKSHELL)<br />

75 (STRAIGHT BACKSHELL)<br />

LUG TERMINATION<br />

M8 X 1,25 X 15,0 DEEP<br />

SCREW & WASHER SUPPLIED WITH<br />

90° BACKSHELL VARIANT ONLY<br />

OR<br />

CRIMP TERMINATION<br />

78,4 (CRIMP)<br />

61 (90° BACKSHELL)<br />

52 (LUG - NO BACKSHELL)<br />

Ø37,5<br />

Ø15 FOR LUG<br />

OUTLINE OF STRAIGHT<br />

BACKSHELL (IF FITTED)<br />

43<br />

OUTLINE OF 90°<br />

BACKSHELL (IF FITTED)<br />

63<br />

Ø32<br />

4.2.4. 300 amp metal receptacle – HBC030R*(A or B)*******<br />

42,6 (CRIMP)<br />

29,36<br />

16,4 (FOR LUG)<br />

Ø3,2<br />

29,36<br />

38,5<br />

Ø24<br />

34 5<br />

Ø15 (FOR LUG)<br />

LUG TERMINATION<br />

M8 X 1,25 X 15,0 DEEP<br />

OR<br />

CRIMP TERMINATION<br />

38,5<br />

V.5_11 Diagrams are not to scale. All dimensions are in mm. Transit caps not shown<br />

P.4


HBC SERIES<br />

4.2. Connector outline drawings<br />

4.2.5. 500 amp plastic plug – HBC050P*1*******<br />

95<br />

70 (FOR LUG)<br />

LUG TERMINATION<br />

M10 X 1,5 X 18,0 DEEP<br />

SCREW & WASHER SUPPLIED<br />

WITH BACKSHELL VARIANT ONLY<br />

90,1 (CRIMP)<br />

Ø45,5<br />

Ø19,5 FOR LUG<br />

OUTLINE OF<br />

BACKSHELL<br />

(IF FITTED)<br />

40,0<br />

72<br />

Ø31,4<br />

4.2.6. 500 amp plastic receptacle – HBC050R*1*******<br />

FOR STRAIGHT CRIMP - SEE DIM A BELOW<br />

34,92<br />

28,7 (FOR LUG, 90° BOOT VARIANT)<br />

Ø4,2<br />

23,5 (FOR LUG, NO BOOT)<br />

BOOT VARIANTS ONLY<br />

HBB050R*1**CO***<br />

34,92<br />

45<br />

Ø32<br />

LUG TERMINATION<br />

M10 X 1,5 X 18,0 DEEP<br />

OR<br />

CRIMP TERMINATION<br />

SEE TABLE BELOW<br />

45<br />

45<br />

7,5<br />

Ø19,5 (FOR LUG)<br />

15<br />

STRAIGHT CRIMP STANDARD BOOT VARIANT<br />

DIM A 43,6 58,9<br />

V.5_11 Diagrams are not to scale. All dimensions are in mm. Transit caps not shown<br />

P.5


HBC SERIES<br />

4.2. Connector outline drawings<br />

4.2.7. 500 amp metal plug – HBC050P*(A or B)*******<br />

101 (90° BACKSHELL)<br />

92 (STRAIGHT BACKSHELL)<br />

75 (90° BACKSHELL)<br />

90,1 (CRIMP)<br />

70 (LUG - NO BACKSHELL)<br />

Ø45,5<br />

Ø19.5 FOR LUG<br />

OUTLINE OF STRAIGHT<br />

BACKSHELL (IF FITTED)<br />

46,5<br />

OUTLINE OF 90°<br />

BACKSHELL (IF FITTED)<br />

LUG TERMINATION<br />

M10 X 1,5 X 18,0 DEEP<br />

SCREW & WASHER SUPPLIED WITH<br />

90° BACKSHELL VARIANT ONLY<br />

OR<br />

CRIMP TERMINATION<br />

77 Ø37<br />

4.2.8. 500 amp metal receptacle – HBC050R*(A or B)*******<br />

43,6 (CRIMP)<br />

34,92<br />

23,5 (FOR LUG)<br />

Ø4,2<br />

34,92<br />

44,5<br />

Ø32<br />

LUG TERMINATION<br />

M10 X 1,5 X 18,0 DEEP<br />

OR<br />

CRIMP TERMINATION<br />

44,5<br />

45 6<br />

Ø19,5 (FOR LUG)<br />

V.5_11 Diagrams are not to scale. All dimensions are in mm. Transit caps not shown<br />

P.6


HBC SERIES<br />

4.3. Mated dimensions<br />

D MAX<br />

DIMENSION WHEN FULLY MATED D MAX<br />

300A METAL 13<br />

300A PLASTIC 13<br />

500A METAL 13.5<br />

500A PLASTIC 13.5<br />

4.4. Metal backshell dimensions<br />

4.4.1. Straight option (optional knurl on ØC)<br />

A<br />

B<br />

Ø C<br />

Ø D<br />

Ø E<br />

F<br />

G<br />

Ø H<br />

DIMENSIONS A B ØC ØD E F G ØH<br />

300A STRAIGHT 6 20 25 27 28 13 5 22<br />

500A STRAIGHT 9.5 20 34 36 38 13 5 30<br />

V.5_11 Diagrams are not to scale. All dimensions are in mm.<br />

P.7


HBC SERIES<br />

4.4. Metal backshell dimensions<br />

4.4.2. Right-angle option (optional knurl on ØC)<br />

A<br />

Ø H<br />

B<br />

F<br />

G<br />

J<br />

Ø C<br />

Ø D<br />

Ø E<br />

DIMENSIONS A B ØC ØD E F G ØH J<br />

300A RIGHT-ANGLE 5 20 30 32 33 13 5 27 43<br />

500A RIGHT-ANGLE 4 20 35 37 39 13 5 32 47<br />

5. Cable assemblies<br />

Connectors can be supplied terminated to a range of highly flexible cables.<br />

Please refer to <strong>Hypertac</strong> Sales or Technical Services for details.<br />

E-mail: info@hypertac.co.uk<br />

Tel: +44 (0) 20 8450 8033<br />

Web: www.hypertac.com<br />

V.5_11 Diagrams are not to scale. All dimensions are in mm.<br />