Supplement to Bulletin 240C<br />

<strong>Thermal</strong> <strong>Performance</strong><br />

<strong>ESW</strong> Models 77-23H to 77-35I<br />

†<br />

<strong>Thermal</strong> performance certified by the Cooling Technology<br />

Institute (CTI) in accordance with CTI Standard STD-201<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 90° 90° 90° 95° 95° 95° 95° 95° 95° 100°<br />

LWT 80° 80° 80° 80° 80° 80° 85° 85° 85° 85°<br />

Model No. WB 68° 70° 72° 66° 68° 70° 75° 76° 78° 72°<br />

<strong>ESW</strong> 77-23H 253 223 * 205 * * 238 223 * 209<br />

<strong>ESW</strong> 77-23I 264 232 197 215 194 * 249 231 198 218<br />

<strong>ESW</strong> 77-23J 285 247 212 232 208 * 264 245 211 233<br />

<strong>ESW</strong> 77-24H 283 250 213 232 210 * 271 252 215 239<br />

<strong>ESW</strong> 77-24I 298 263 224 245 220 196 283 264 225 250<br />

<strong>ESW</strong> 77-24J 323 283 241 266 239 213 306 283 241 269<br />

<strong>ESW</strong> 77-25H 309 272 235 255 229 204 297 276 238 262<br />

<strong>ESW</strong> 77-25I 325 287 245 268 243 215 312 290 248 276<br />

<strong>ESW</strong> 77-25J 355 313 266 294 265 235 336 314 268 300<br />

<strong>ESW</strong> 77-26H 329 290 249 273 246 219 318 297 254 283<br />

<strong>ESW</strong> 77-26I 349 308 264 289 261 232 335 312 268 298<br />

<strong>ESW</strong> 77-26J 382 336 287 316 286 255 363 338 290 324<br />

<strong>ESW</strong> 77-33H 269 235 201 219 197 * 253 235 201 221<br />

<strong>ESW</strong> 77-33I 283 245 210 230 207 * 263 244 210 232<br />

<strong>ESW</strong> 77-33J 302 261 225 248 222 197 280 262 225 247<br />

<strong>ESW</strong> 77-34H 304 269 228 250 225 200 288 269 229 255<br />

<strong>ESW</strong> 77-34I 321 282 239 264 238 211 303 281 239 267<br />

<strong>ESW</strong> 77-34J 348 306 256 287 258 228 323 302 254 288<br />

<strong>ESW</strong> 77-35H 333 294 250 274 249 221 318 296 252 282<br />

<strong>ESW</strong> 77-35I 353 311 264 291 263 233 334 312 266 297<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 100° 100° 97° 115° 115° 100° 102° 105° 105° 105°<br />

LWT 85° 85° 87° 90° 90° 90° 90° 90° 90° 90°<br />

Model No. WB 74° 76° 78° 74° 76° 80° 78° 76° 78° 80°<br />

<strong>ESW</strong> 77-23H * * 230 * * 256 253 236 214 *<br />

<strong>ESW</strong> 77-23I 196 * 239 * * 265 262 245 222 197<br />

<strong>ESW</strong> 77-23J 209 * 254 197 * 283 279 261 236 209<br />

<strong>ESW</strong> 77-24H 214 * 261 205 * 292 289 270 245 218<br />

<strong>ESW</strong> 77-24I 224 198 274 214 198 305 302 283 256 227<br />

<strong>ESW</strong> 77-24J 242 214 292 230 213 326 324 303 274 244<br />

<strong>ESW</strong> 77-25H 236 209 287 227 211 321 318 299 271 242<br />

<strong>ESW</strong> 77-25I 249 220 301 239 222 336 333 313 284 254<br />

<strong>ESW</strong> 77-25J 269 237 324 258 241 362 358 337 306 273<br />

<strong>ESW</strong> 77-26H 254 225 309 247 229 347 343 322 293 261<br />

<strong>ESW</strong> 77-26I 268 238 324 260 242 363 359 338 308 275<br />

<strong>ESW</strong> 77-26J 292 259 352 281 263 392 388 366 332 297<br />

<strong>ESW</strong> 77-33H 199 * 242 * * 270 267 250 225 200<br />

<strong>ESW</strong> 77-33I 208 * 253 195 * 282 278 259 235 208<br />

<strong>ESW</strong> 77-33J 221 195 265 209 * 296 295 275 249 220<br />

<strong>ESW</strong> 77-34H 228 202 278 218 202 310 307 288 261 231<br />

<strong>ESW</strong> 77-34I 240 212 291 228 212 324 322 301 272 242<br />

<strong>ESW</strong> 77-34J 258 227 311 245 226 345 343 321 291 259<br />

<strong>ESW</strong> 77-35H 254 224 308 244 226 343 339 319 289 258<br />

<strong>ESW</strong> 77-35I 267 236 322 256 239 359 356 334 304 271<br />

Notes:<br />

1. Conditions are based on WATER as the Cooling Fluid.<br />

2. CTI Certified performance capability based on Standard and Super Low Sound Fan.<br />

3. For more CTI Certified selections, consult EVAPCO’s iES Selection Program.<br />

4. High flow header connections may be required for some flow rates.<br />

* Flow outside limits allowed for model.<br />

† Mark owned by the Cooling Technology Institute.<br />

1


Supplement to Bulletin 240C<br />

<strong>Thermal</strong> <strong>Performance</strong><br />

<strong>ESW</strong> Models 77-35J to 77-46J<br />

†<br />

<strong>Thermal</strong> performance certified by the Cooling Technology<br />

Institute (CTI) in accordance with CTI Standard STD-201<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 90° 90° 90° 95° 95° 95° 95° 95° 95° 100°<br />

LWT 80° 80° 80° 80° 80° 80° 85° 85° 85° 85°<br />

Model No. WB 68° 70° 72° 66° 68° 70° 75° 76° 78° 72°<br />

<strong>ESW</strong> 77-35J 386 336 285 319 287 254 360 335 284 321<br />

<strong>ESW</strong> 77-36H 357 315 269 295 267 238 342 318 273 305<br />

<strong>ESW</strong> 77-36I 379 333 284 314 284 254 360 336 288 321<br />

<strong>ESW</strong> 77-36J 414 363 310 345 312 278 391 363 311 349<br />

<strong>ESW</strong> 77-43I 297 258 224 244 219 193 275 256 219 243<br />

<strong>ESW</strong> 77-43J 317 272 241 260 232 204 294 275 231 258<br />

<strong>ESW</strong> 77-44I 342 299 251 281 253 223 318 296 250 283<br />

<strong>ESW</strong> 77-44J 365 328 271 305 271 241 340 318 266 303<br />

<strong>ESW</strong> 77-45I 377 330 280 312 281 250 354 329 280 315<br />

<strong>ESW</strong> 77-45J 406 356 302 339 305 269 378 352 297 339<br />

<strong>ESW</strong> 77-46I 405 356 305 338 305 271 383 356 307 342<br />

<strong>ESW</strong> 77-46J 440 387 327 368 334 294 410 384 325 369<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 100° 100° 97° 115° 115° 100° 102° 105° 105° 105°<br />

LWT 85° 85° 87° 90° 90° 90° 90° 90° 90° 90°<br />

Model No. WB 74° 76° 78° 74° 76° 80° 78° 76° 78° 80°<br />

<strong>ESW</strong> 77-35J 289 255 347 276 257 387 383 359 327 291<br />

<strong>ESW</strong> 77-36H 274 243 330 265 247 370 366 345 314 280<br />

<strong>ESW</strong> 77-36I 290 257 350 280 261 390 385 364 330 295<br />

<strong>ESW</strong> 77-36J 316 279 377 302 282 419 416 392 357 319<br />

<strong>ESW</strong> 77-43I 218 * 262 205 * 292 290 271 245 217<br />

<strong>ESW</strong> 77-43J 230 206 276 217 200 308 305 286 258 227<br />

<strong>ESW</strong> 77-44I 254 223 307 241 223 341 338 316 287 255<br />

<strong>ESW</strong> 77-44J 270 238 322 256 237 358 359 336 306 269<br />

<strong>ESW</strong> 77-45I 283 250 341 272 252 380 377 353 321 286<br />

<strong>ESW</strong> 77-45J 305 268 361 291 269 402 403 377 343 305<br />

<strong>ESW</strong> 77-46I 309 273 369 296 277 411 408 385 350 313<br />

<strong>ESW</strong> 77-46J 334 294 395 319 297 438 438 412 375 336<br />

Notes:<br />

1. Conditions are based on WATER as the Cooling Fluid.<br />

2. CTI Certified performance capability based on Standard and Super Low Sound Fan.<br />

3. For more CTI Certified selections, consult EVAPCO’s iES Selection Program.<br />

4. High flow header connections may be required for some flow rates.<br />

* Flow outside limits allowed for model.<br />

† Mark owned by the Cooling Technology Institute.<br />

2


Supplement to Bulletin 240C<br />

<strong>Thermal</strong> <strong>Performance</strong><br />

<strong>ESW</strong> Models 102-33H to 102-36J<br />

†<br />

<strong>Thermal</strong> performance certified by the Cooling Technology<br />

Institute (CTI) in accordance with CTI Standard STD-201<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 90° 90° 90° 95° 95° 95° 95° 95° 95° 100°<br />

LWT 80° 80° 80° 80° 80° 80° 85° 85° 85° 85°<br />

Model No. WB 68° 70° 72° 66° 68° 70° 75° 76° 78° 72°<br />

<strong>ESW</strong> 102-23H 373 328 277 303 271 241 357 332 280 313<br />

<strong>ESW</strong> 102-23I 390 343 289 317 284 253 372 346 292 325<br />

<strong>ESW</strong> 102-24H 415 366 311 340 306 269 400 373 317 352<br />

<strong>ESW</strong> 102-24I 436 384 328 357 321 283 418 390 333 368<br />

<strong>ESW</strong> 102-25H 450 394 338 369 333 293 436 405 346 384<br />

<strong>ESW</strong> 102-25I 473 415 357 389 350 310 458 425 364 404<br />

<strong>ESW</strong> 102-26H 478 418 360 392 354 313 466 434 368 410<br />

<strong>ESW</strong> 102-26I 502 442 378 414 374 331 490 455 387 432<br />

<strong>ESW</strong> 102-33H 396 349 293 321 289 256 377 350 296 329<br />

<strong>ESW</strong> 102-33I 417 368 309 338 304 269 394 368 310 344<br />

<strong>ESW</strong> 102-33J 447 389 332 363 326 289 420 388 332 367<br />

<strong>ESW</strong> 102-34H 443 390 333 363 326 288 424 396 338 374<br />

<strong>ESW</strong> 102-34I 469 412 351 384 346 306 448 416 354 395<br />

<strong>ESW</strong> 102-34J 506 445 376 415 373 330 479 447 378 423<br />

<strong>ESW</strong> 102-35H 481 422 363 397 356 316 465 432 370 410<br />

<strong>ESW</strong> 102-35I 511 450 385 421 379 335 490 457 390 433<br />

<strong>ESW</strong> 102-35J 552 486 413 455 411 365 526 490 417 468<br />

<strong>ESW</strong> 102-36H 510 450 385 422 381 337 497 462 393 439<br />

<strong>ESW</strong> 102-36I 543 480 410 451 406 360 524 489 419 468<br />

<strong>ESW</strong> 102-36J 592 520 445 489 442 395 567 526 451 505<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 100° 100° 97° 115° 115° 100° 102° 105° 105° 105°<br />

LWT 85° 85° 87° 90° 90° 90° 90° 90° 90° 90°<br />

Model No. WB 74° 76° 78° 74° 76° 80° 78° 76° 78° 80°<br />

<strong>ESW</strong> 102-23H 278 246 344 265 245 384 381 354 322 283<br />

<strong>ESW</strong> 102-23I 290 256 360 275 254 399 396 368 333 294<br />

<strong>ESW</strong> 102-24H 316 277 388 302 280 436 432 403 366 324<br />

<strong>ESW</strong> 102-24I 330 290 404 316 293 455 450 420 381 338<br />

<strong>ESW</strong> 102-25H 344 304 422 334 309 478 473 442 403 356<br />

<strong>ESW</strong> 102-25I 361 320 442 350 324 498 494 462 420 373<br />

<strong>ESW</strong> 102-26H 369 325 452 361 333 510 506 473 431 383<br />

<strong>ESW</strong> 102-26I 388 343 474 380 351 533 528 496 452 402<br />

<strong>ESW</strong> 102-33H 294 259 364 279 257 404 400 373 337 298<br />

<strong>ESW</strong> 102-33I 308 271 380 292 269 424 418 392 353 311<br />

<strong>ESW</strong> 102-33J 328 289 401 309 286 448 444 414 374 330<br />

<strong>ESW</strong> 102-34H 335 294 410 320 297 461 456 426 387 343<br />

<strong>ESW</strong> 102-34I 353 312 432 338 312 483 479 447 405 360<br />

<strong>ESW</strong> 102-34J 379 333 461 361 335 515 510 478 433 384<br />

<strong>ESW</strong> 102-35H 367 325 450 355 329 506 500 469 426 378<br />

<strong>ESW</strong> 102-35I 389 343 474 376 348 531 526 494 449 400<br />

<strong>ESW</strong> 102-35J 420 370 510 404 375 569 563 531 480 427<br />

<strong>ESW</strong> 102-36H 395 349 481 386 357 541 536 504 459 408<br />

<strong>ESW</strong> 102-36I 419 371 509 408 379 572 566 531 484 431<br />

<strong>ESW</strong> 102-36J 454 403 548 440 409 612 606 572 520 464<br />

Notes:<br />

1. Conditions are based on WATER as the Cooling Fluid.<br />

2. CTI Certified performance capability based on Standard and Super Low Sound Fan.<br />

3. For more CTI Certified selections, consult EVAPCO’s iES Selection Program.<br />

4. High flow header connections may be required for some flow rates.<br />

* Flow outside limits allowed for model.<br />

† Mark owned by the Cooling Technology Institute.<br />

3


Supplement to Bulletin 240C<br />

<strong>Thermal</strong> <strong>Performance</strong><br />

<strong>ESW</strong> Models 102-43I to 102-46J<br />

†<br />

<strong>Thermal</strong> performance certified by the Cooling Technology<br />

Institute (CTI) in accordance with CTI Standard STD-201<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 90° 90° 90° 95° 95° 95° 95° 95° 95° 100°<br />

LWT 80° 80° 80° 80° 80° 80° 85° 85° 85° 85°<br />

Model No. WB 68° 70° 72° 66° 68° 70° 75° 76° 78° 72°<br />

<strong>ESW</strong> 102-43I 438 383 325 356 319 283 412 382 325 360<br />

<strong>ESW</strong> 102-43J 470 406 353 382 341 301 435 403 348 384<br />

<strong>ESW</strong> 102-44I 494 435 368 405 364 323 469 437 371 414<br />

<strong>ESW</strong> 102-44J 531 466 394 437 394 348 502 465 394 442<br />

<strong>ESW</strong> 102-45I 539 475 404 444 403 356 516 480 409 457<br />

<strong>ESW</strong> 102-45J 584 513 435 482 434 385 552 515 439 492<br />

<strong>ESW</strong> 102-46I 578 509 435 478 431 384 554 516 442 494<br />

<strong>ESW</strong> 102-46J 624 550 469 518 468 417 595 554 475 531<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 100° 100° 97° 115° 115° 100° 102° 105° 105° 105°<br />

LWT 85° 85° 87° 90° 90° 90° 90° 90° 90° 90°<br />

Model No. WB 74° 76° 78° 74° 76° 80° 78° 76° 78° 80°<br />

<strong>ESW</strong> 102-43I 323 284 394 304 282 441 436 407 367 325<br />

<strong>ESW</strong> 102-43J 342 300 418 322 297 469 461 430 390 343<br />

<strong>ESW</strong> 102-44I 371 326 453 354 328 506 502 470 425 377<br />

<strong>ESW</strong> 102-44J 397 349 481 378 350 537 533 498 452 401<br />

<strong>ESW</strong> 102-45I 411 363 498 396 367 557 552 519 471 419<br />

<strong>ESW</strong> 102-45J 442 389 532 424 395 594 589 554 502 448<br />

<strong>ESW</strong> 102-46I 443 394 535 430 400 600 594 560 510 455<br />

<strong>ESW</strong> 102-46J 479 423 576 461 431 640 634 600 545 487<br />

Notes:<br />

1. Conditions are based on WATER as the Cooling Fluid.<br />

2. CTI Certified performance capability based on Standard and Super Low Sound Fan.<br />

3. For more CTI Certified selections, consult EVAPCO’s iES Selection Program.<br />

4. High flow header connections may be required for some flow rates.<br />

* Flow outside limits allowed for model.<br />

† Mark owned by the Cooling Technology Institute.<br />

4


Supplement to Bulletin 240C<br />

<strong>Thermal</strong> <strong>Performance</strong><br />

<strong>ESW</strong> Models 153-23H to 153-35I<br />

†<br />

<strong>Thermal</strong> performance certified by the Cooling Technology<br />

Institute (CTI) in accordance with CTI Standard STD-201<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 90° 90° 90° 95° 95° 95° 95° 95° 95° 100°<br />

LWT 80° 80° 80° 80° 80° 80° 85° 85° 85° 85°<br />

Model No. WB 68° 70° 72° 66° 68° 70° 75° 76° 78° 72°<br />

<strong>ESW</strong> 153-23H 610 539 456 498 446 393 585 547 463 514<br />

<strong>ESW</strong> 153-23I 644 567 480 525 473 417 616 572 485 541<br />

<strong>ESW</strong> 153-23J 703 620 523 576 515 456 665 621 526 587<br />

<strong>ESW</strong> 153-24H 676 593 508 555 499 440 655 608 520 576<br />

<strong>ESW</strong> 153-24I 717 630 542 591 529 469 690 642 551 609<br />

<strong>ESW</strong> 153-24J 784 692 589 647 587 518 750 699 595 665<br />

<strong>ESW</strong> 153-25H 726 639 547 598 540 477 709 659 560 624<br />

<strong>ESW</strong> 153-25I 770 680 581 638 575 509 748 697 594 664<br />

<strong>ESW</strong> 153-25J 850 750 643 706 636 567 816 760 652 729<br />

<strong>ESW</strong> 153-26H 765 675 577 632 573 506 748 703 594 663<br />

<strong>ESW</strong> 153-26I 814 720 615 678 611 541 792 741 631 707<br />

<strong>ESW</strong> 153-26J 900 797 684 752 680 606 868 812 700 779<br />

<strong>ESW</strong> 153-33H 655 576 488 534 481 425 626 581 492 549<br />

<strong>ESW</strong> 153-33I 694 611 516 567 509 450 657 613 519 580<br />

<strong>ESW</strong> 153-33J 759 663 559 622 558 493 713 660 557 628<br />

<strong>ESW</strong> 153-34H 730 642 552 601 539 477 702 653 559 619<br />

<strong>ESW</strong> 153-34I 774 683 582 638 578 510 741 690 588 657<br />

<strong>ESW</strong> 153-34J 851 750 637 706 635 563 805 751 642 718<br />

<strong>ESW</strong> 153-35H 784 693 592 651 587 519 760 709 606 677<br />

<strong>ESW</strong> 153-35I 839 741 635 696 627 557 805 751 644 718<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 100° 100° 97° 115° 115° 100° 102° 105° 105° 105°<br />

LWT 85° 85° 87° 90° 90° 90° 90° 90° 90° 90°<br />

Model No. WB 74° 76° 78° 74° 76° 80° 78° 76° 78° 80°<br />

<strong>ESW</strong> 153-23H 459 402 565 438 405 634 629 586 531 470<br />

<strong>ESW</strong> 153-23I 484 424 594 460 425 664 657 614 556 493<br />

<strong>ESW</strong> 153-23J 524 460 641 498 460 716 709 663 601 530<br />

<strong>ESW</strong> 153-24H 516 456 632 499 461 714 705 660 601 532<br />

<strong>ESW</strong> 153-24I 545 481 667 526 488 750 742 695 631 561<br />

<strong>ESW</strong> 153-24J 598 526 725 575 532 809 801 753 684 609<br />

<strong>ESW</strong> 153-25H 561 495 686 549 507 771 766 718 655 582<br />

<strong>ESW</strong> 153-25I 595 527 725 581 538 813 805 757 691 614<br />

<strong>ESW</strong> 153-25J 654 581 789 635 590 882 873 824 752 672<br />

<strong>ESW</strong> 153-26H 599 526 729 590 546 818 813 762 699 622<br />

<strong>ESW</strong> 153-26I 635 564 769 627 581 863 857 807 740 660<br />

<strong>ESW</strong> 153-26J 702 623 842 686 640 938 931 880 807 722<br />

<strong>ESW</strong> 153-33H 491 431 603 467 432 674 667 623 564 499<br />

<strong>ESW</strong> 153-33I 517 454 635 492 455 709 701 656 594 524<br />

<strong>ESW</strong> 153-33J 562 493 684 533 492 762 758 707 641 566<br />

<strong>ESW</strong> 153-34H 555 489 677 535 496 760 753 707 641 570<br />

<strong>ESW</strong> 153-34I 591 520 716 568 525 799 792 744 676 602<br />

<strong>ESW</strong> 153-34J 647 568 776 619 576 865 858 806 733 654<br />

<strong>ESW</strong> 153-35H 606 537 737 591 548 827 818 769 703 625<br />

<strong>ESW</strong> 153-35I 645 572 779 627 583 872 864 814 743 663<br />

Notes:<br />

1. Conditions are based on WATER as the Cooling Fluid.<br />

2. CTI Certified performance capability based on Standard and Super Low Sound Fan.<br />

3. For more CTI Certified selections, consult EVAPCO’s iES Selection Program.<br />

4. High flow header connections may be required for some flow rates.<br />

* Flow outside limits allowed for model.<br />

† Mark owned by the Cooling Technology Institute.<br />

5


Supplement to Bulletin 240C<br />

<strong>Thermal</strong> <strong>Performance</strong><br />

<strong>ESW</strong> Models 153-35J to 153-46K<br />

†<br />

<strong>Thermal</strong> performance certified by the Cooling Technology<br />

Institute (CTI) in accordance with CTI Standard STD-201<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 90° 90° 90° 95° 95° 95° 95° 95° 95° 100°<br />

LWT 80° 80° 80° 80° 80° 80° 85° 85° 85° 85°<br />

Model No. WB 68° 70° 72° 66° 68° 70° 75° 76° 78° 72°<br />

<strong>ESW</strong> 153-35J 923 816 697 769 695 620 879 821 705 787<br />

<strong>ESW</strong> 153-36H 829 734 628 692 624 553 807 754 644 721<br />

<strong>ESW</strong> 153-36I 887 785 674 742 670 597 856 802 689 767<br />

<strong>ESW</strong> 153-36J * 869 744 821 745 668 936 877 754 845<br />

<strong>ESW</strong> 153-43I 733 643 544 603 540 478 693 642 545 610<br />

<strong>ESW</strong> 153-43J 797 701 585 658 591 518 743 692 579 660<br />

<strong>ESW</strong> 153-43K 831 744 614 694 616 546 775 729 603 690<br />

<strong>ESW</strong> 153-44I 822 725 615 679 613 543 780 729 620 695<br />

<strong>ESW</strong> 153-44J 901 789 671 748 674 597 845 786 669 755<br />

<strong>ESW</strong> 153-44K 941 895 703 790 714 627 880 824 696 791<br />

<strong>ESW</strong> 153-45I 890 785 671 740 670 599 852 793 680 761<br />

<strong>ESW</strong> 153-45J * 863 740 820 742 660 926 862 743 830<br />

<strong>ESW</strong> 153-45K * 907 773 866 786 696 * 903 770 872<br />

<strong>ESW</strong> 153-46I 941 837 719 788 715 639 909 848 730 818<br />

<strong>ESW</strong> 153-46J * 920 790 878 797 711 * 924 799 892<br />

<strong>ESW</strong> 153-46K * 967 831 928 844 753 * * 832 937<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 100° 100° 97° 115° 115° 100° 102° 105° 105° 105°<br />

LWT 85° 85° 87° 90° 90° 90° 90° 90° 90° 90°<br />

Model No. WB 74° 76° 78° 74° 76° 80° 78° 76° 78° 80°<br />

<strong>ESW</strong> 153-35J 711 628 852 685 640 943 935 886 808 722<br />

<strong>ESW</strong> 153-36H 647 576 782 638 593 878 872 822 751 672<br />

<strong>ESW</strong> 153-36I 692 615 831 677 632 928 921 868 796 713<br />

<strong>ESW</strong> 153-36J 763 679 912 740 692 * * 951 867 778<br />

<strong>ESW</strong> 153-43I 546 480 664 517 479 740 736 687 622 550<br />

<strong>ESW</strong> 153-43J 590 515 713 558 514 793 787 737 668 593<br />

<strong>ESW</strong> 153-43K 613 540 735 581 536 817 820 767 697 612<br />

<strong>ESW</strong> 153-44I 624 549 755 599 557 841 832 784 712 633<br />

<strong>ESW</strong> 153-44J 680 598 816 651 604 906 899 844 771 686<br />

<strong>ESW</strong> 153-44K 715 626 846 681 631 936 935 880 802 717<br />

<strong>ESW</strong> 153-45I 686 608 826 663 618 917 909 861 782 699<br />

<strong>ESW</strong> 153-45J 752 666 893 721 673 * * 930 848 760<br />

<strong>ESW</strong> 153-45K 790 698 933 758 705 * * * 885 799<br />

<strong>ESW</strong> 153-46I 736 655 881 716 669 * * 920 840 754<br />

<strong>ESW</strong> 153-46J 812 719 955 782 731 * * * 910 821<br />

<strong>ESW</strong> 153-46K 851 756 * 822 768 * * * 952 860<br />

Notes:<br />

1. Conditions are based on WATER as the Cooling Fluid.<br />

2. CTI Certified performance capability based on Standard and Super Low Sound Fan.<br />

3. For more CTI Certified selections, consult EVAPCO’s iES Selection Program.<br />

4. High flow header connections may be required for some flow rates.<br />

* Flow outside limits allowed for model.<br />

† Mark owned by the Cooling Technology Institute.<br />

6


Supplement to Bulletin 240C<br />

<strong>Thermal</strong> <strong>Performance</strong><br />

<strong>ESW</strong> Models 144-23I to 144-34L<br />

†<br />

<strong>Thermal</strong> performance certified by the Cooling Technology<br />

Institute (CTI) in accordance with CTI Standard STD-201<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 90° 90° 90° 95° 95° 95° 95° 95° 95° 100°<br />

LWT 80° 80° 80° 80° 80° 80° 85° 85° 85° 85°<br />

Model No. WB 68° 70° 72° 66° 68° 70° 75° 76° 78° 72°<br />

<strong>ESW</strong> 144-23I 536 472 400 439 392 347 516 482 407 454<br />

<strong>ESW</strong> 144-23J 577 511 431 471 422 374 553 515 436 485<br />

<strong>ESW</strong> 144-23K 607 535 452 494 446 394 578 538 455 507<br />

<strong>ESW</strong> 144-24I 594 522 446 486 439 385 575 536 455 506<br />

<strong>ESW</strong> 144-24J 642 565 484 528 475 419 619 577 494 546<br />

<strong>ESW</strong> 144-24K 680 598 513 557 501 444 650 606 519 574<br />

<strong>ESW</strong> 144-25I 639 560 481 524 475 417 623 580 493 549<br />

<strong>ESW</strong> 144-25J 695 609 524 572 515 457 676 626 535 594<br />

<strong>ESW</strong> 144-25K 733 646 554 607 546 484 709 660 565 628<br />

<strong>ESW</strong> 144-26I 678 592 507 555 500 442 662 615 523 583<br />

<strong>ESW</strong> 144-26J 733 647 554 606 549 485 716 669 568 633<br />

<strong>ESW</strong> 144-26K 777 687 587 645 583 516 756 704 601 674<br />

<strong>ESW</strong> 144-33I 577 510 431 470 422 373 552 515 435 484<br />

<strong>ESW</strong> 144-33J 617 544 460 503 453 401 586 547 463 514<br />

<strong>ESW</strong> 144-33K 651 573 484 531 476 423 614 573 486 540<br />

<strong>ESW</strong> 144-33L 680 594 502 556 498 443 640 592 504 562<br />

<strong>ESW</strong> 144-34I 641 564 483 527 474 418 618 576 493 545<br />

<strong>ESW</strong> 144-34J 692 608 521 568 511 453 662 615 527 584<br />

<strong>ESW</strong> 144-34K 730 643 547 600 543 480 697 648 552 615<br />

<strong>ESW</strong> 144-34L 765 675 571 630 569 502 725 678 575 643<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 100° 100° 97° 115° 115° 100° 102° 105° 105° 105°<br />

LWT 85° 85° 87° 90° 90° 90° 90° 90° 90° 90°<br />

Model No. WB 74° 76° 78° 74° 76° 80° 78° 76° 78° 80°<br />

<strong>ESW</strong> 144-23I 404 356 500 386 357 559 555 516 469 413<br />

<strong>ESW</strong> 144-23J 433 381 533 412 381 595 590 550 499 442<br />

<strong>ESW</strong> 144-23K 454 399 559 432 399 621 615 575 520 461<br />

<strong>ESW</strong> 144-24I 455 399 557 437 405 629 624 583 530 470<br />

<strong>ESW</strong> 144-24J 489 431 599 470 436 676 667 623 567 502<br />

<strong>ESW</strong> 144-24K 514 454 628 494 458 706 698 654 594 527<br />

<strong>ESW</strong> 144-25I 494 434 604 481 443 686 678 633 578 512<br />

<strong>ESW</strong> 144-25J 534 473 652 519 481 733 727 683 622 552<br />

<strong>ESW</strong> 144-25K 564 498 687 547 507 771 763 716 652 580<br />

<strong>ESW</strong> 144-26I 526 463 644 516 476 727 722 674 617 549<br />

<strong>ESW</strong> 144-26J 570 504 696 561 518 781 777 727 666 592<br />

<strong>ESW</strong> 144-26K 603 537 732 592 550 822 815 767 701 624<br />

<strong>ESW</strong> 144-33I 432 381 533 412 381 594 589 549 498 442<br />

<strong>ESW</strong> 144-33J 461 405 568 438 405 631 625 584 528 467<br />

<strong>ESW</strong> 144-33K 483 425 591 458 424 660 652 610 552 488<br />

<strong>ESW</strong> 144-33L 503 443 612 475 440 684 678 632 573 506<br />

<strong>ESW</strong> 144-34I 488 430 598 469 435 675 666 622 566 501<br />

<strong>ESW</strong> 144-34J 524 462 639 503 466 716 709 664 603 537<br />

<strong>ESW</strong> 144-34K 553 487 674 530 491 750 744 698 632 563<br />

<strong>ESW</strong> 144-34L 578 507 700 553 513 780 773 726 659 586<br />

Notes:<br />

1. Conditions are based on WATER as the Cooling Fluid.<br />

2. CTI Certified performance capability based on Standard and Super Low Sound Fan.<br />

3. For more CTI Certified selections, consult EVAPCO’s iES Selection Program.<br />

4. High flow header connections may be required for some flow rates.<br />

* Flow outside limits allowed for model.<br />

† Mark owned by the Cooling Technology Institute.<br />

7


Supplement to Bulletin 240C<br />

<strong>Thermal</strong> <strong>Performance</strong><br />

<strong>ESW</strong> Models 144-35I to 144-46L<br />

†<br />

<strong>Thermal</strong> performance certified by the Cooling Technology<br />

Institute (CTI) in accordance with CTI Standard STD-201<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 90° 90° 90° 95° 95° 95° 95° 95° 95° 100°<br />

LWT 80° 80° 80° 80° 80° 80° 85° 85° 85° 85°<br />

Model No. WB 68° 70° 72° 66° 68° 70° 75° 76° 78° 72°<br />

<strong>ESW</strong> 144-35I 693 608 523 570 514 456 674 625 534 593<br />

<strong>ESW</strong> 144-35J 748 659 566 620 558 494 721 673 576 640<br />

<strong>ESW</strong> 144-35K 794 700 598 656 593 526 761 709 606 678<br />

<strong>ESW</strong> 144-35L 833 734 625 690 623 556 794 740 632 708<br />

<strong>ESW</strong> 144-36I 732 646 553 605 548 484 715 668 567 632<br />

<strong>ESW</strong> 144-36J 793 701 600 660 595 528 769 717 613 687<br />

<strong>ESW</strong> 144-36K 847 746 640 703 634 566 812 759 652 726<br />

<strong>ESW</strong> 144-36L 886 783 672 737 668 597 854 793 682 763<br />

<strong>ESW</strong> 144-43J 650 572 483 530 475 422 613 572 485 539<br />

<strong>ESW</strong> 144-43K 686 598 506 561 502 446 645 596 503 567<br />

<strong>ESW</strong> 144-43L 719 624 526 587 525 464 668 619 521 591<br />

<strong>ESW</strong> 144-44J 728 642 546 599 542 479 696 647 551 614<br />

<strong>ESW</strong> 144-44K 772 683 576 636 574 507 731 684 580 649<br />

<strong>ESW</strong> 144-44L 810 711 603 670 602 534 765 709 603 678<br />

<strong>ESW</strong> 144-45J 792 699 597 655 592 525 759 707 605 676<br />

<strong>ESW</strong> 144-45K 842 741 631 697 629 562 801 747 638 714<br />

<strong>ESW</strong> 144-45L 884 780 664 736 663 590 838 781 671 748<br />

<strong>ESW</strong> 144-46J 845 744 638 702 633 564 811 758 651 725<br />

<strong>ESW</strong> 144-46K 895 791 678 745 675 604 861 800 688 769<br />

<strong>ESW</strong> 144-46L 942 834 712 788 712 636 898 840 720 806<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 100° 100° 97° 115° 115° 100° 102° 105° 105° 105°<br />

LWT 85° 85° 87° 90° 90° 90° 90° 90° 90° 90°<br />

Model No. WB 74° 76° 78° 74° 76° 80° 78° 76° 78° 80°<br />

<strong>ESW</strong> 144-35I 533 472 651 518 480 732 726 682 621 551<br />

<strong>ESW</strong> 144-35J 574 508 699 557 517 784 776 728 664 591<br />

<strong>ESW</strong> 144-35K 608 538 735 588 546 823 814 767 698 623<br />

<strong>ESW</strong> 144-35L 637 565 770 615 572 860 850 803 727 648<br />

<strong>ESW</strong> 144-36I 569 503 694 560 517 779 775 726 664 591<br />

<strong>ESW</strong> 144-36J 616 547 746 603 560 838 830 780 713 636<br />

<strong>ESW</strong> 144-36K 653 581 787 637 593 881 873 823 753 672<br />

<strong>ESW</strong> 144-36L 688 610 825 666 622 917 909 861 784 702<br />

<strong>ESW</strong> 144-43J 483 424 590 457 423 659 651 609 552 488<br />

<strong>ESW</strong> 144-43K 506 446 617 479 443 690 683 638 577 509<br />

<strong>ESW</strong> 144-43L 527 462 642 498 460 717 708 661 599 529<br />

<strong>ESW</strong> 144-44J 552 486 672 529 490 749 743 697 631 562<br />

<strong>ESW</strong> 144-44K 584 512 705 558 518 786 779 731 664 591<br />

<strong>ESW</strong> 144-44L 609 537 734 581 539 818 813 761 692 614<br />

<strong>ESW</strong> 144-45J 607 537 734 587 545 821 813 765 697 622<br />

<strong>ESW</strong> 144-45K 643 570 777 620 577 866 857 809 733 654<br />

<strong>ESW</strong> 144-45L 676 595 809 648 606 899 892 841 765 685<br />

<strong>ESW</strong> 144-46J 652 579 786 636 592 879 872 822 751 671<br />

<strong>ESW</strong> 144-46K 694 616 833 672 628 925 917 870 791 708<br />

<strong>ESW</strong> 144-46L 728 645 871 703 657 965 957 909 827 740<br />

Notes:<br />

1. Conditions are based on WATER as the Cooling Fluid.<br />

2. CTI Certified performance capability based on Standard and Super Low Sound Fan.<br />

3. For more CTI Certified selections, consult EVAPCO’s iES Selection Program.<br />

4. High flow header connections may be required for some flow rates.<br />

* Flow outside limits allowed for model.<br />

† Mark owned by the Cooling Technology Institute.<br />

8


Supplement to Bulletin 240C<br />

<strong>Thermal</strong> <strong>Performance</strong><br />

<strong>ESW</strong> Models 216-23J to 216-34K<br />

†<br />

<strong>Thermal</strong> performance certified by the Cooling Technology<br />

Institute (CTI) in accordance with CTI Standard STD-201<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 90° 90° 90° 95° 95° 95° 95° 95° 95° 100°<br />

LWT 80° 80° 80° 80° 80° 80° 85° 85° 85° 85°<br />

Model No. WB 68° 70° 72° 66° 68° 70° 75° 76° 78° 72°<br />

<strong>ESW</strong> 216-23J 853 751 646 703 631 560 820 764 655 724<br />

<strong>ESW</strong> 216-23K 890 785 671 734 663 586 853 794 678 756<br />

<strong>ESW</strong> 216-23L 919 812 690 759 688 608 879 819 697 779<br />

<strong>ESW</strong> 216-23M 947 836 709 782 707 626 900 841 716 801<br />

<strong>ESW</strong> 216-24J 932 825 705 775 699 619 904 844 721 807<br />

<strong>ESW</strong> 216-24K 979 864 741 816 734 652 942 881 757 842<br />

<strong>ESW</strong> 216-24L 1015 896 769 843 761 679 974 908 780 871<br />

<strong>ESW</strong> 216-24M 1044 922 790 868 786 703 1004 933 802 896<br />

<strong>ESW</strong> 216-25J 993 880 754 831 751 666 967 904 774 866<br />

<strong>ESW</strong> 216-25K 1043 923 793 873 791 703 1011 945 813 908<br />

<strong>ESW</strong> 216-25L 1080 959 825 907 822 732 1045 980 843 940<br />

<strong>ESW</strong> 216-25M 1113 992 853 935 848 757 1075 1008 868 971<br />

<strong>ESW</strong> 216-26J 1040 923 794 871 795 703 1015 954 819 913<br />

<strong>ESW</strong> 216-26K 1091 970 836 918 837 742 1064 998 858 959<br />

<strong>ESW</strong> 216-26L 1130 1009 868 956 870 774 1098 1035 890 994<br />

<strong>ESW</strong> 216-26M 1166 1045 898 989 900 803 1129 1065 919 1026<br />

<strong>ESW</strong> 216-33K 955 843 715 789 713 631 906 848 721 807<br />

<strong>ESW</strong> 216-33L 990 874 742 822 739 656 937 875 747 836<br />

<strong>ESW</strong> 216-33M 1022 897 764 849 764 679 965 896 766 858<br />

<strong>ESW</strong> 216-34K 1053 930 797 876 793 710 1011 940 807 903<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 100° 100° 97° 115° 115° 100° 102° 105° 105° 105°<br />

LWT 85° 85° 87° 90° 90° 90° 90° 90° 90° 90°<br />

Model No. WB 74° 76° 78° 74° 76° 80° 78° 76° 78° 80°<br />

<strong>ESW</strong> 216-23J 649 573 792 626 581 888 879 826 749 667<br />

<strong>ESW</strong> 216-23K 680 598 825 653 605 920 912 857 779 695<br />

<strong>ESW</strong> 216-23L 701 618 850 674 624 947 938 882 801 714<br />

<strong>ESW</strong> 216-23M 720 634 872 691 642 972 962 905 822 731<br />

<strong>ESW</strong> 216-24J 723 642 877 706 656 984 974 916 838 746<br />

<strong>ESW</strong> 216-24K 756 672 913 738 686 1024 1014 955 873 778<br />

<strong>ESW</strong> 216-24L 783 696 942 761 709 1053 1043 984 899 804<br />

<strong>ESW</strong> 216-24M 808 718 970 783 730 1079 1069 1012 921 825<br />

<strong>ESW</strong> 216-25J 780 693 940 770 717 1053 1046 987 905 811<br />

<strong>ESW</strong> 216-25K 820 728 984 803 750 1098 1089 1027 943 845<br />

<strong>ESW</strong> 216-25L 847 754 1015 831 776 1129 1122 1062 974 873<br />

<strong>ESW</strong> 216-25M 873 778 1044 854 798 1157 1149 1092 999 900<br />

<strong>ESW</strong> 216-26J 827 732 990 817 764 1106 1101 1040 957 859<br />

<strong>ESW</strong> 216-26K 867 773 1037 856 802 1153 1147 1087 999 898<br />

<strong>ESW</strong> 216-26L 899 803 1071 885 830 1190 1184 1121 1031 928<br />

<strong>ESW</strong> 216-26M 926 829 1100 912 854 1220 1214 1153 1061 959<br />

<strong>ESW</strong> 216-33K 726 639 878 697 647 978 968 911 828 737<br />

<strong>ESW</strong> 216-33L 752 662 903 720 671 1006 998 938 853 761<br />

<strong>ESW</strong> 216-33M 773 683 927 740 688 1032 1026 963 876 780<br />

<strong>ESW</strong> 216-34K 815 723 978 789 737 1087 1077 1020 928 831<br />

Notes:<br />

1. Conditions are based on WATER as the Cooling Fluid.<br />

2. CTI Certified performance capability based on Standard and Super Low Sound Fan.<br />

3. For more CTI Certified selections, consult EVAPCO’s iES Selection Program.<br />

4. High flow header connections may be required for some flow rates.<br />

* Flow outside limits allowed for model.<br />

† Mark owned by the Cooling Technology Institute.<br />

9


Supplement to Bulletin 240C<br />

<strong>Thermal</strong> <strong>Performance</strong><br />

<strong>ESW</strong> Models 216-34L to 216-45N<br />

†<br />

<strong>Thermal</strong> performance certified by the Cooling Technology<br />

Institute (CTI) in accordance with CTI Standard STD-201<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 90° 90° 90° 95° 95° 95° 95° 95° 95° 100°<br />

LWT 80° 80° 80° 80° 80° 80° 85° 85° 85° 85°<br />

Model No. WB 68° 70° 72° 66° 68° 70° 75° 76° 78° 72°<br />

<strong>ESW</strong> 216-34L 1092 966 828 912 825 737 1043 974 837 935<br />

<strong>ESW</strong> 216-34M 1127 1000 854 947 854 762 1072 1004 863 964<br />

<strong>ESW</strong> 216-35K 1122 1001 861 943 856 765 1084 1016 875 980<br />

<strong>ESW</strong> 216-35L 1165 1039 892 983 893 800 1121 1050 905 1013<br />

<strong>ESW</strong> 216-35M 1205 1073 921 1019 926 830 1153 1082 933 1045<br />

<strong>ESW</strong> 216-36K 1176 1055 907 999 908 811 1138 1073 929 1035<br />

<strong>ESW</strong> 216-36L 1222 1094 945 1041 948 848 1182 1109 962 1077<br />

<strong>ESW</strong> 216-36M 1264 1129 976 1081 984 883 1216 1142 992 1110<br />

<strong>ESW</strong> 216-43K 1021 897 764 848 764 678 965 896 766 858<br />

<strong>ESW</strong> 216-43L 1057 926 786 878 791 700 990 921 784 886<br />

<strong>ESW</strong> 216-43M 1086 957 810 908 822 722 1015 948 803 912<br />

<strong>ESW</strong> 216-43N 1131 1005 848 957 856 759 1059 995 835 954<br />

<strong>ESW</strong> 216-44K 1127 1000 854 946 854 762 1071 1004 863 964<br />

<strong>ESW</strong> 216-44L 1167 1032 886 982 890 792 1108 1032 890 993<br />

<strong>ESW</strong> 216-44M 1212 1064 910 1015 922 820 1136 1061 909 1025<br />

<strong>ESW</strong> 216-44N 1260 1118 950 1072 972 861 1183 1112 944 1072<br />

<strong>ESW</strong> 216-45K 1204 1072 921 1019 925 829 1152 1081 933 1044<br />

<strong>ESW</strong> 216-45L 1251 1112 956 1061 966 862 1192 1117 968 1080<br />

<strong>ESW</strong> 216-45M 1294 1145 990 1098 1001 896 1229 1147 995 1113<br />

<strong>ESW</strong> 216-45N * 1204 1034 1160 1058 944 1278 1203 1030 1165<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 100° 100° 97° 115° 115° 100° 102° 105° 105° 105°<br />

LWT 85° 85° 87° 90° 90° 90° 90° 90° 90° 90°<br />

Model No. WB 74° 76° 78° 74° 76° 80° 78° 76° 78° 80°<br />

<strong>ESW</strong> 216-34L 844 748 1012 815 762 1121 1110 1054 960 859<br />

<strong>ESW</strong> 216-34M 872 771 1039 839 784 1149 1141 1081 985 884<br />

<strong>ESW</strong> 216-35K 881 785 1052 860 805 1166 1158 1101 1007 907<br />

<strong>ESW</strong> 216-35L 915 818 1091 892 834 1205 1197 1141 1041 937<br />

<strong>ESW</strong> 216-35M 947 842 1121 919 859 1239 1228 1170 1072 965<br />

<strong>ESW</strong> 216-36K 935 836 1108 919 861 1229 1222 1161 1070 967<br />

<strong>ESW</strong> 216-36L 974 870 1149 952 892 1269 1262 1203 1106 999<br />

<strong>ESW</strong> 216-36M 1005 899 1187 983 921 1305 1297 1238 1139 1026<br />

<strong>ESW</strong> 216-43K 773 683 927 740 687 1032 1026 962 876 780<br />

<strong>ESW</strong> 216-43L 798 702 956 763 708 1062 1052 988 903 804<br />

<strong>ESW</strong> 216-43M 825 721 978 784 727 1083 1078 1014 925 830<br />

<strong>ESW</strong> 216-43N 855 756 1008 816 758 1116 1120 1054 965 853<br />

<strong>ESW</strong> 216-44K 871 771 1038 839 784 1149 1140 1081 985 885<br />

<strong>ESW</strong> 216-44L 902 800 1069 866 808 1184 1177 1114 1015 911<br />

<strong>ESW</strong> 216-44M 929 824 1101 894 833 1219 1207 1141 1044 940<br />

<strong>ESW</strong> 216-44N 973 862 1136 935 868 1254 1255 1188 1086 977<br />

<strong>ESW</strong> 216-45K 946 842 1120 919 858 1239 1228 1169 1072 965<br />

<strong>ESW</strong> 216-45L 982 872 1154 950 889 1274 1264 1206 1102 995<br />

<strong>ESW</strong> 216-45M 1010 903 1188 981 916 1313 1299 1238 1134 1023<br />

<strong>ESW</strong> 216-45N 1062 945 1235 1026 957 * * 1288 1180 1069<br />

Notes:<br />

1. Conditions are based on WATER as the Cooling Fluid.<br />

2. CTI Certified performance capability based on Standard and Super Low Sound Fan.<br />

3. For more CTI Certified selections, consult EVAPCO’s iES Selection Program.<br />

4. High flow header connections may be required for some flow rates.<br />

* Flow outside limits allowed for model.<br />

† Mark owned by the Cooling Technology Institute.<br />

10


Supplement to Bulletin 240C<br />

<strong>Thermal</strong> <strong>Performance</strong><br />

<strong>ESW</strong> Models 216-46K to 216-46N<br />

†<br />

<strong>Thermal</strong> performance certified by the Cooling Technology<br />

Institute (CTI) in accordance with CTI Standard STD-201<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 90° 90° 90° 95° 95° 95° 95° 95° 95° 100°<br />

LWT 80° 80° 80° 80° 80° 80° 85° 85° 85° 85°<br />

Model No. WB 68° 70° 72° 66° 68° 70° 75° 76° 78° 72°<br />

<strong>ESW</strong> 216-46K 1263 1128 976 1080 983 882 1216 1142 991 1109<br />

<strong>ESW</strong> 216-46L 1313 1173 1013 1123 1022 918 1257 1183 1028 1149<br />

<strong>ESW</strong> 216-46M * 1212 1052 1164 1061 956 1298 1216 1063 1183<br />

<strong>ESW</strong> 216-46N * 1271 1099 1231 1123 1007 1350 1272 1099 1239<br />

COOLER CAPABILITY IN USGPM AT THE FOLLOWING TEMPERATURE CONDITIONS (°F)<br />

EWT 100° 100° 97° 115° 115° 100° 102° 105° 105° 105°<br />

LWT 85° 85° 87° 90° 90° 90° 90° 90° 90° 90°<br />

Model No. WB 74° 76° 78° 74° 76° 80° 78° 76° 78° 80°<br />

<strong>ESW</strong> 216-46K 1005 898 1186 982 920 1305 1297 1238 1138 1026<br />

<strong>ESW</strong> 216-46L 1040 930 1221 1017 956 1343 1333 1273 1171 1059<br />

<strong>ESW</strong> 216-46M 1074 964 1257 1048 985 * * 1308 1207 1089<br />

<strong>ESW</strong> 216-46N 1128 1010 1309 1097 1027 * * * 1255 1143<br />

Notes:<br />

1. Conditions are based on WATER as the Cooling Fluid.<br />

2. CTI Certified performance capability based on Standard and Super Low Sound Fan.<br />

3. For more CTI Certified selections, consult EVAPCO’s iES Selection Program.<br />

4. High flow header connections may be required for some flow rates.<br />

* Flow outside limits allowed for model.<br />

† Mark owned by the Cooling Technology Institute.<br />

11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!