<strong>Heavy</strong>-<strong>Duty</strong> <strong>Commercial</strong> <strong>Gas</strong><br />

Introducing the next generation of natural gas and propane water<br />

heaters now featuring an integrated control. The new line features<br />

a significantly lower profile, smaller vent diameters, and a new,<br />

ultra-accurate dual electronic thermostat for precision temperature<br />

control. These water heaters handle a wide range of applications<br />

that require inputs from<br />

125,000 BTU to 399,000 BTU.<br />

All <strong>Heavy</strong>-<strong>Duty</strong> <strong>Commercial</strong><br />

<strong>Gas</strong> units have a glass coated<br />

internally-lined tank that<br />

provides a tough interior<br />

surface for storage tanks and<br />

maximum protection against<br />

the wearing effects of<br />

high-volume and hightemperature<br />

water.<br />

3-Year Limited Tank/ 1-Year Limited Parts Warranty*<br />

• Intelligent electronic integrated<br />

control, featuring:<br />

- Self diagnostics<br />

- Displays error codes<br />

- Displays temperature at each sensor<br />

- Temperature can be adjusted from<br />

90º F to 180º F<br />

- All connections inside the integrated<br />

control are not interchangeable<br />

(less likely to have errors)<br />

- Ease of serviceability and installation<br />

• Factory Installed T&P - Front located brass drain valve.<br />

• Multiple <strong>Water</strong> Connections - Top, front, and back – see table.<br />

• Ceramic Fiber Combusion Chamber - New light weight ceramic fiber<br />

combustion chamber for reduced heat loss.<br />

• Multiple Anode Rods - Provides cathodic protection for longer tank life<br />

through even distribution, for protection against corrosion of tank interior.<br />

• Long Lasting Stainless Steel Burners<br />

• Slide out Burner - Easy out, slide out burner tray for easy servicing.<br />

• Cleanout Opening - Conveniently located handhole cleanout.<br />

• Vent Damper for Energy Efficiency<br />

• ASHRAE Standard 90.1b (Current Standard) - Meets or exceeds<br />

ASHRAE 90.1 1999 energy efficiency standard, meets or exceeds 80%<br />

thermal efficiency<br />

Options<br />

• New pre-certified conversion kits for liquid propane/natural gas conversions<br />

for all models. CSA-approved kits allow field conversions with no need for<br />

additional inspection or costs<br />

• ASME models available in 199,000-399,000 BTU<br />

• Power vent kit available for side wall venting with a new quick connect<br />

system for ease of installation<br />

• High altitude conversion kits available for installations in regions up to 8,000 ft.<br />

DCG3-75T125-5NH through<br />

ADCG3-100T270-7NH<br />

*For complete warranty information consult the written warranty of <strong>American</strong> <strong>Water</strong> <strong>Heaters</strong> found at www.americanwaterheater.com, or call (800) 999-9515.<br />

Copyright© by <strong>American</strong>® <strong>Water</strong> <strong>Heaters</strong> 2008. All rights reserved.<br />

NCGSS00107 R Feb. 2008<br />

No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system, without permission in writing from <strong>American</strong> <strong>Water</strong> <strong>Heaters</strong>.


<strong>Heavy</strong>-<strong>Duty</strong> <strong>Commercial</strong> <strong>Gas</strong><br />

C<br />

DCG3 B Series<br />

C<br />

OUTLET<br />

B<br />

INLET<br />

1" CLEARANCE<br />

OUTLET<br />

INLET<br />

1" CLEARANCE<br />

1" NPT<br />

RELIEF<br />

VALVE<br />

OPENING<br />

D<br />

ELECTRICAL REQUIREMENTS:<br />

Need 120 Volt 60 Cycle AC Power Source. Draws less than 5 amps.<br />

D<br />

TOP<br />

OUTLET<br />

1" NPT<br />

RELIEF<br />

VALVE A<br />

OPENING<br />

A<br />

CONNECTION<br />

SPREAD<br />

TOP<br />

OUTLET<br />

HGT. TO HGT. TO TOP HGT. TO HGT. TO HGT. TO SIZE HGT. TO APPROX.<br />

MODEL GAL. TOP OF JACKET TOP OF VENT CONN. FRT/BACK FRT/BACK GAS OF GAS T&P T&P SHIP.<br />

NUMBER CAP. VENT DIA. HEATER SIZE SPREAD HOT COLD CONN. CONN. OPENING OPEN. WT.<br />

A B C D LBS.<br />

DCG3-75T125-5NH 75 68-3/4 26-9/16 62-3/8 6 19 54 20-1/4 4-1/4 3/4 54 3/4 480<br />

TOP DCG3-80T199-6NH 80 73-3/4 28-1/2 62 6 21-1/4 53-3/4 20-3/4 4-1/4 3/4 53-3/4 3/4 580<br />

INLET<br />

DCG3-80T250-6NH 80 73-3/4 28-1/2 62 6 21-1/4 53-3/4 20-3/4 4-1/4 3/4 53-1/4 1 580<br />

DCG3-100T199-6NH 100 74-1/2 28-1/2 69 6 21-1/4 60-3/4 20-3/4 4-1/4 3/4 60-3/4 3/4 615<br />

DCG3-100T270-7NH 100 78-3/4 28-1/2 69-1/8 7 21-1/4 60-3/4 20-3/4 4-1/4 3/4 60-3/4 1 630<br />

DCG3-75T300-7NH 75 72-1/2 28-1/2 64 7 21-1/4 55-3/4 22-3/4 5-1/4 3/4 55-3/4 1 590<br />

DCG3-75T360-8NH 75 71-1/2 28-1/2 62-1/2 8 21-1/4 53-1/4 30-3/4* 4-1/4 3/4 53-1/4 1 640<br />

DCG3-80T399-8NH* 80 71-1/2 28-1/2 62-1/2 8 21-1/4 53-1/4 30-3/4* 4-1/4 3/4 53-1/4 1 640<br />

ASME TOP<br />

ADCG3-100T270-7NH INLET 100 78-3/4 28-1/2 69-1/8 7 21-1/4 60-3/4 20-3/4 4-1/4 3/4 55-3/4 1 647<br />

ADCG3-75T300-7NH 75 72-1/2 28-1/2 64 7 21-1/4* 55-3/4 22-3/4 5-1/4 3/4 53-1/4 1 716<br />

ADCG3-75T360-8NH 75 71-1/2 28-1/2 62-1/2 8 N/A 53-1/4 30-3/4* 4-1/4 3/4 53-1/4 1 720<br />

CONNECTION ADCG3-80T399-8NH 75 71-1/2 28-1/2 62-1/2 8 N/A 53-1/4 30-3/4* 4-1/4 3/4 53-1/4 1 835<br />

SPREADASME models are prefixed with an “A”.<br />

Dimensions on all charts shown in inches.<br />

To order propane models change suffix from “N” to “P.”<br />

Limited warranty on tank and parts. Complete details in manual.<br />

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.<br />

MODEL GAS BTU TEMPERATURE RISE<br />

NUMBER TYPE INPUT 40˚ 100° 140°<br />

DCG3-75T125-5NH NAT/PRO 175,000 303 121 87<br />

DCG3-80T199-6NH NAT/PRO 199,000 482 193 138<br />

DCG3-80T250-6NH NAT/PRO 250,000 606 242 173<br />

DCG3-100T199-6NH NAT/PRO 199,000 482 193 138<br />

DCG3-100T270-7NH NAT/PRO 270,000 655 262 187<br />

DCG3-75T300-7NH NAT/PRO 300,000 727 291 208<br />

RECOVERY IN GALLONS AT VARIOUS TEMP. RISES<br />

MODEL GAS BTU TEMPERATURE RISE<br />

NUMBER TYPE INPUT 40˚ 100° 140°<br />

DCG3-75T360-8NH NAT/PRO 360,000 873 349 249<br />

DCG3-80T399-8NH* NAT/PRO 399,000 967 387 276<br />

ADCG3-100T270-7NH NAT/PRO 270,000 655 262 187<br />

ADCG3-75T300-7NH NAT/PRO 300,000 727 291 208<br />

ADCG3-75T360-8N NAT/PRO 360,000 873 349 249<br />

ADCG3-80T399-8NH NAT/PRO 399,000 967 387 276<br />

<strong>Commercial</strong> <strong>Gas</strong> Builder Block System<br />

BENEFITS:<br />

• Utilizes reverse return flow dynamics<br />

• Ease of Installation<br />

• Diversity of being able to isolate one heater for service without shutting<br />

down entire system<br />

• Less restrictions than yolk manifold<br />

• Takes up less space in mechanical room<br />

• May be used to add redundancy to hot water system, avoiding<br />

total loss of hot water if one unit fails<br />

C<br />

HR<br />

Mixing<br />

Valve<br />

T<br />

TR<br />

H<br />

Additional installation diagrams available - order publication CPIGuide0704<br />

Optional<br />

Two Temperature<br />

Installation<br />

<strong>Heavy</strong>-<strong>Duty</strong> <strong>Commercial</strong> <strong>Gas</strong> <strong>Water</strong> Heater Specification<br />

<strong>Commercial</strong> gas-fired water heater(s) shall be <strong>American</strong>® Model ____________________________ designed to burn _______________________ gas and design certified by the<br />

Underwriters Laboratory to the latest addition of ANSI Z21.10.3 or CSA 4.3 for up to 180˚F water, and meet or exceed all applicable energy codes. <strong>Water</strong> heater(s) shall have a storage<br />

capacity of _______ gallons, a minimum input rating of _____Btuh and a recovery rating of _______ GPH (based upon 80% thermal efficiencies) at a _________˚F temperature rise.<br />

<strong>Water</strong> heater(s) steel tank shall have a working pressure of 160 PSI and shall have a glass coated internally lined tank and fired at 1600˚F allowing for maximum protection. <strong>Water</strong><br />

heater(s) shall be provided with a full-sized cleanout opening, and an AGA-approved pressure and temperature relief valve factory installed. <strong>Water</strong> heater(s) shall be equipped with a<br />

integrated control circuit consisting of 180˚F adjustable thermostat with upper and lower sensors to maintain an average water temperature throughout the tank allowing maximum<br />

water temperature control. <strong>Water</strong> heater(s) shall be provided with a recycling energy cutoff (ECO) device, gas pressure regulator set for the type of gas supplied, electronic ignition,<br />

agency-approved (flue damper with draft diverter) or (induced draft blower), and anodes for cathodic protection. The outer jacketing shall have a baked enamel finish. The tank shall<br />

be foam insulated with an EPA-approved, non-CFC material. <strong>Water</strong> heater(s) shall have a 3-year limited warranty against corrosion as outlined in the written warranty. Fully illustrated<br />

operation, installation and service manual included with unit.<br />

Order Entry and Sales<br />

500 Princeton Road (FEDEX, UPS)<br />

Johnson City, TN 37601-2030<br />

P.O. Box 4808 (Mailing)<br />

Johnson City, TN 37602-4808<br />

(800) 937-1037<br />

FAX (800) 581-7224 fax<br />

Distributed By:<br />

NCGSS00107 R Feb. 2008<br />

Warranty and Service<br />

500 Princeton Road (FEDEX, UPS)<br />

Johnson City, TN 37601-2030<br />

P.O. Box 1597 (Mailing)<br />

Johnson City, TN 37605-1597<br />

(800) 456-9805<br />

FAX (800) 999-5210<br />

No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system, without permission in writing from <strong>American</strong> <strong>Water</strong> <strong>Heaters</strong>.