SPECIFICATIONS<br />
HI 96 series<br />
Water Resistant Single Parameter <strong>Photometer</strong>s<br />
with HANNA’s Exclusive CAL CHECK<br />
Parameter Code* Range Precision<br />
Ammonia,<br />
Medium Range<br />
Chlorine,<br />
Ultra High Range<br />
HI 96715<br />
HI 96771<br />
0.00 to 9.99 mg/L<br />
(as NH 3 -N)<br />
UHR: 0 to 500 mg/L<br />
LR: 0.00 to 5.00 mg/L<br />
Chlorine, Free HI 96701 0.00 to 5.00 mg/L<br />
Chlorine, Free<br />
for Drinking Water Applications<br />
HI 96762<br />
Chlorine, Free and Total HI 96781<br />
Chlorine, Free and Total HI 96724<br />
Chlorine, Free and Total,<br />
High Range<br />
Chlorine, Total for the Analysis of<br />
Trace Total Chlorine Concentration<br />
Copper,<br />
Low Range<br />
HI 96734<br />
HI 96761<br />
HI 96747<br />
Detergents, Anionic HI 96769<br />
Fluoride,<br />
Low Range<br />
Iron,<br />
High Range<br />
Nitrite,<br />
Low Range<br />
Phosphate,<br />
High Range<br />
HI 96729<br />
HI 96721<br />
HI 96707<br />
HI 96717<br />
0.000 to 0.500 mg/L<br />
Free Cl 2 : 0.00 to 5.00 mg/L;<br />
Total Cl 2 : 0.00 to 5.00 mg/L<br />
Free Cl 2 : 0.00 to 5.00 mg/L;<br />
Total Cl 2 : 0.00 to 5.00 mg/L<br />
Free Cl 2 : 0.00 to 10.00 mg/L;<br />
Total Cl 2 : 0.00 to 10.00 mg/L<br />
0.000 to 0.500 mg/L<br />
0.000 to 1.500 mg/L<br />
0.00 to 3.50 mg/L<br />
(as SDBS)<br />
0.00 to 2.00 mg/L<br />
0.00 to 5.00 mg/L<br />
0.000 to 0.600 mg/L<br />
(as NO 2<br />
- -N)<br />
0.0 to 30.0 mg/L<br />
Phosphorus HI 96706 0.0 to 15.0 mg/L<br />
Silica HI 96770 0 to 200 mg/L (as SiO 2 )<br />
±0.12 mg/L<br />
@ 6.00 mg/L<br />
±2 mg/L<br />
@ 100 mg/L<br />
±0.02 mg/L<br />
@ 1.00 mg/L<br />
±0.02 mg/L<br />
@ 1.00 mg/L<br />
±0.004 mg/L<br />
@ 0.200 mg/L<br />
±0.02 mg/L<br />
@ 1.00 mg/L<br />
±0.03 mg/L<br />
@ 1.00 mg/L<br />
±0.06 mg/L<br />
@ 3.00 mg/L<br />
±0.004 mg/L<br />
@ 0.200 mg/L<br />
±0.015 mg/L<br />
@ 0.750 mg/L<br />
±0.04 mg/L<br />
@ 1.00 mg/L<br />
±0.03 mg/L<br />
@ 1.00 mg/L<br />
±0.01 mg/L<br />
@ 1.50 mg/L<br />
±0.001 mg/L<br />
@ 0.100 mg/L<br />
±0.5 mg/L<br />
@ 12 mg/L<br />
±0.2 mg/L<br />
@ 6.0 mg/L<br />
±5 mg/L<br />
@ 100 mg/L<br />
Narrow<br />
Band Filter<br />
Method<br />
@ 466 nm<br />
Adaptation of the ASTM Manual of Water and<br />
Environmental Technology, D1426-93, Nessler Method.<br />
@ 525 nm<br />
@ 525 nm<br />
@ 525 nm<br />
@ 525 nm<br />
@ 525 nm<br />
@ 525 nm<br />
@ 525 nm<br />
@ 560 nm<br />
@ 610 nm<br />
@ 575 nm<br />
@ 525 nm<br />
@ 525 nm<br />
@ 525 nm<br />
@ 525 nm<br />
@ 466 nm<br />
Adaptation of Standard Methods, 20th edition, 4500-Cl.<br />
Adaptation of the USEPA method 330.5 and Standard<br />
Method 4500-Cl G.<br />
Adaptation of Standard Methods, 20th edition,<br />
4500-Cl G.<br />
Adaptation of the USEPA method 330.5 and Standard<br />
Method 4500-Cl G.<br />
Adaptation of the USEPA method 330.5 and Standard<br />
Method 4500-Cl G.<br />
Adaptation of the USEPA method 330.5 and Standard<br />
Method 4500-Cl G.<br />
Adaptation of Standard Methods, 20th edition,<br />
4500-Cl G.<br />
Adaptation of the USEPA approved bicinchoninate<br />
method.<br />
Adaptation of the USEPA method 425.1 for drinking<br />
waters, surface waters, domestic and industrial wastes<br />
and Standard Methods, 20th edition, 5540C, Anionic<br />
Surfactants as MBAS.<br />
Adaptation of the EPA method 340.1 and SPADNS<br />
method.<br />
Adaptation of the USEPA method 315B and Standard<br />
Method 3500-Fe B.<br />
Adaptation of an EPA approved method.<br />
Amino Acid Method, adapted from Standard Method<br />
for the Examination of Water and Wastewater.<br />
Amino Acid Method, adapted from Standard Method<br />
for the Examination of Water and Wastewater.<br />
Adaptation of the USEPA method 370.1 for drinking,<br />
surface and saline waters, domestic and industrial<br />
wastes and Standard Method 4500-SiO 2 C.<br />
Single Parameter <strong>Photometer</strong>s<br />
Portable Meters<br />
SPECIFICATIONS common to all models<br />
Light Source<br />
Tungsten lamp; LED (HI 96715 and HI 96770 only)<br />
Environment<br />
0 to 50°C (32 to 122°F); Max 95% RH non-condensing<br />
Battery Type/Life<br />
(1) 9V/approx. 200 hours continuous use<br />
Auto Shut-off<br />
After 10 minutes of non-use in measurement mode<br />
Dimensions/Weight<br />
192 x 102 x 67 mm (7.6 x 4 x 2.6”)/290 g (10 oz.)<br />
ORDERING INFORMATION<br />
HI 96 series of photometers are supplied with<br />
sample cuvets with caps, 9V battery and<br />
instruction manual.<br />
HI 96 “C” series of photometers is supplied with<br />
CAL CHECK standard cuvets, sample cuvets with<br />
caps, 9V battery, cuvet cleaning cloth and<br />
instruction manual in a hard carrying case<br />
(additional accessories such as glass vials, pipettes<br />
and scissors are included when applicable).<br />
Available as a KIT<br />
Includes CAL CHECK standard cuvets, cuvet<br />
cleaning cloth and scissors (when applicable)<br />
bundled in a deluxe hardshell carrying case.<br />
Just add a “C” at the end of<br />
the part #. Eg: HI 96715C<br />
HI 95<br />
Series<br />
Available<br />
WWW. HANNAINST. COM<br />
113