25.11.2014 Views

ArtNet-DMX STAGE-PROFI 1.1 - DMX4ALL GmbH

ArtNet-DMX STAGE-PROFI 1.1 - DMX4ALL GmbH

ArtNet-DMX STAGE-PROFI 1.1 - DMX4ALL GmbH

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>ArtNet</strong>-<strong>DMX</strong><br />

<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong><br />

User Manual<br />

Art-Net Designed by and Copyright Alderamin Group Ltd.


<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 2<br />

Description<br />

The <strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> has a switchable <strong>DMX</strong>-INPUT/<strong>DMX</strong>-OUTPUT<br />

with a 3 pin XLR connectorn. A standard RJ45 connector is used to connect to the<br />

<strong>ArtNet</strong> network<br />

A user-friendly configuration via web browser allows a fast and uncomplicated<br />

adjustment for all parameters.<br />

An additional extension-mode allows an output of 1024 <strong>DMX</strong>-channels on the <strong>DMX</strong>output.<br />

This Extension-mode is optimised for controlling the MagiarLED products.<br />

Data Sheet<br />

Power supply:<br />

5V DC from external power supply (included)<br />

Ethernet:<br />

1x RJ45 (10 BASE-T)<br />

<strong>DMX</strong>:<br />

1x<br />

Neutrik XLR female connector 3 pin<br />

For <strong>DMX</strong>-INPUT operation a <strong>DMX</strong> adapter MALE/MALE is necessary<br />

Dimensions (LxBxH):<br />

75 x 26 x 35 mm


<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 3<br />

Connection<br />

POWER 5V<br />

LED<br />

RESET-button<br />

<strong>DMX</strong>-INPUT /<br />

<strong>DMX</strong>-OUTPUT<br />

Ethernet-connection


<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 4<br />

LED-display<br />

LED green<br />

The green LED flashes if no Ethernet connection exists and shines no-stop if an<br />

Ethernet connection is given.<br />

LED yellow<br />

The yellow LED lights up as soon as data are received.<br />

Configuration<br />

The configuration of the <strong>ArtNet</strong>-<strong>DMX</strong>-<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> occurs about an webinterface<br />

which can be called about any web browser.<br />

The assigned IP-address 2.0.0.10 in the delivery status will be used for the webinterface<br />

as well as for the <strong>ArtNet</strong>.<br />

The network settings of the PC must be<br />

configured to the IP-address 2.0.0.1 and<br />

the subnet mask to 255.0.0.0.<br />

Please consult the <strong>ArtNet</strong>-specifications for<br />

further details.


<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 5<br />

Please call the IP 2.0.0.10 in the address bar of the web browser for getting the<br />

following configuration page:<br />

Each node needs an own IP-address, so the assignment in the network<br />

occurs clearly. According to the <strong>ArtNet</strong>-specifications please use the IPaddresses<br />

2.x.x.x or 10.x.x.x.<br />

Ather IP addresses are also possible, for example 192.168.<strong>1.1</strong>0. Then the<br />

Netmask must be changed to 255.255.255.0 !<br />

For an easier identification you can assign each node with any names.<br />

The Short-name is limited to 18 signs and the Long-name to 64 signs.


<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 6<br />

The Netmask is left to 255.0.0.0 according to the <strong>ArtNet</strong>-specifications.<br />

The Interface mode can be configured as <strong>DMX</strong>-INPUT or <strong>DMX</strong>-OUTPUT.<br />

The Factory settings will be rebuilt by entering the number 7319.<br />

SAVE stores the configuration respectively rebuilt the Factory settings.<br />

<strong>DMX</strong>-Input<br />

For using the <strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> as a <strong>DMX</strong>-INPUT interface please<br />

select the interface mode Set the interface to Input Mode.<br />

Please use a 1:1 MALE-MALE adapter for the connection which is separately<br />

available.<br />

Use Broadcast: <strong>DMX</strong> data is sent ro all <strong>ArtNet</strong> devices<br />

Use Unicast: <strong>DMX</strong> data is sent to one <strong>ArtNet</strong> device witch has the Unicast IP.<br />

In an event of a <strong>DMX</strong>-signal failure (<strong>DMX</strong> FAIL) several actions can be selected for<br />

the <strong>DMX</strong>-input:<br />

NO DATA<br />

- with <strong>ArtNet</strong> no <strong>DMX</strong>-input will be received<br />

HOLD last <strong>DMX</strong> data<br />

- the last data will hold<br />

CLEAR all <strong>DMX</strong> channels to 0% - all <strong>DMX</strong> channels will be set on 0<br />

SET all <strong>DMX</strong> channels to 100% - all <strong>DMX</strong> channels will be set on 255<br />

The Update-rate with whom the <strong>DMX</strong>-input data are outputted can be adjusted in<br />

different times.<br />

On change data transfers the <strong>DMX</strong> data only if it change, however max. every 0,1<br />

seconds.<br />

<strong>DMX</strong> Framerate transfers the <strong>DMX</strong> data when a <strong>DMX</strong> frame is complete received. In<br />

this case the Update-rate is equal to the <strong>DMX</strong> framerate.<br />

<strong>DMX</strong>-Output<br />

For using the <strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> as a <strong>DMX</strong>-OUTPUT interface please<br />

select the interface mode Set the interface to Output Mode.


<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 7<br />

Extension Mode<br />

The <strong>ArtNet</strong>-<strong>DMX</strong>-UNIVERSE <strong>1.1</strong> interface has an extension mode. Then the <strong>DMX</strong>output<br />

is set to 1024 <strong>DMX</strong>-channels. 2 ports (each 512 <strong>DMX</strong>-channels) will be spent<br />

on the <strong>DMX</strong>-output consecutively. Therefore all in all 1024 channels are possible.<br />

For activating the extension mode, please use a web browser.<br />

In the extension mode an additional <strong>ArtNet</strong> port will be activated which has also<br />

512channels.<br />

The <strong>DMX</strong> Routing in the configuration specifies for the <strong>DMX</strong>-output how the data of<br />

the ports are linked together.<br />

The entered value specifies how many <strong>DMX</strong>-channels from the first port should be<br />

spent. After that the <strong>DMX</strong>-channels of the second port will be attached.<br />

Example: <strong>DMX</strong>-Routing = 512<br />

Channel Kanal 1 1 Channel Kanal 512 Channel Kanal 513 513 Channel Kanal 1024<br />

Port Port 11 (512 Channels) Kanäle)<br />

Port Port 2 2 (512 (512 Channels) Kanäle)<br />

Example: <strong>DMX</strong>-Routing = 450<br />

Channel Kanal 11 Channel Kanal 450 450 Kanal Channel 451 451 Channel Kanal 962 962 Channel Kanal 1024<br />

Port Port 1 (450 1 (450 Channels) Kanäle)<br />

Port Port 2 (512 2 (512 Channels) Kanäle)<br />

Channels up to 1024<br />

will be filled with 0<br />

<strong>DMX</strong>-Routing examples<br />

The following examples refer to the application with the indicated products.<br />

Routing Product<br />

511 MagiarLED II Stripe 12xRGB<br />

510 MagiarLED III flex Stripe without configuration channel


<strong>DMX</strong>4ALL-Command support<br />

<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 8<br />

The <strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> interface has an additional communication-port<br />

which can receive the data from TCP-bundle at the port 10001. This port uses the<br />

<strong>DMX</strong>4ALL-Commands in this way, that the <strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> interface<br />

is compatible to the LAN-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong>.<br />

TCP-Control<br />

For control the interface directly with the TCP-connection please use the preset IPaddress<br />

and use the port 10001. The sent and received data are RAW-data bundle.<br />

Please take the <strong>DMX</strong>4ALL-Commands which are possible from the separate<br />

<strong>DMX</strong>4ALL-Command description.<br />

VCP-Control<br />

For the control with a COM-port a TCP-VCP-program must be installed which<br />

provides a virtual Com port (VCP).<br />

We recommend the tool Serial to Ethernet Connection which has been tested by us.<br />

You find this tool on the enclosed CD and as an download in our support-sector.<br />

During the installation you have to<br />

enter a password (see illustration).


<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 9<br />

After the installation start the tool „<br />

Sentos SEC” which is on the<br />

desktop. Now add a VCP with Add<br />

and specify the parameter for the<br />

VCP-port.<br />

Make sure, that you use the IP which<br />

is adjusted about the web browser.<br />

Finally, click Update all in the main<br />

menu window for activating the<br />

VCP. Now, the status became<br />

Available and the COM-port will be<br />

displayed in the device manager.<br />

Factory Reset<br />

The <strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> interface can be reset into the delivery status<br />

with the button next to the RJ45 connector.<br />

Please proceed as follows:<br />

- Power off the device<br />

- Push the button and hold down<br />

- Power on the device<br />

- Green and yellow LED flashes now ca. 10 seconds alternate<br />

- Release the button during the alternate LED flashing<br />

- The reset will be executed and the LEDs flashes 3x simultaneous for<br />

confirmation


<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 10<br />

<strong>DMX</strong> over WLAN<br />

The <strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> can used together with WiiFi components to<br />

transfer the <strong>DMX</strong> data wireless. It is possible to transfer one or more <strong>DMX</strong> universes.<br />

The following drawing show the use of the components:<br />

WiFi<br />

Adapter<br />

<strong>ArtNet</strong>-<strong>DMX</strong><br />

<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong><br />

<strong>DMX</strong><br />

UNIVERSE 1<br />

<strong>DMX</strong><br />

UNIVERSE 1<br />

<strong>ArtNet</strong>-<strong>DMX</strong><br />

<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong><br />

WiFi<br />

Adapter<br />

Configurated as <strong>DMX</strong>-Output<br />

<strong>ArtNet</strong>: Net 0 / Port 1<br />

Configurated as <strong>DMX</strong>-Input<br />

<strong>ArtNet</strong>: Net 0 / Port 1<br />

WiFi<br />

Access<br />

Point<br />

LAN<br />

Switch<br />

<strong>ArtNet</strong>-<strong>DMX</strong><br />

<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong><br />

Configurated as <strong>DMX</strong>-Output<br />

<strong>ArtNet</strong>: Net 0 / Port 1<br />

<strong>DMX</strong><br />

UNIVERSE 1<br />

<strong>ArtNet</strong>-<strong>DMX</strong><br />

<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong><br />

<strong>DMX</strong><br />

UNIVERSE 2<br />

<strong>DMX</strong><br />

UNIVERSE 2<br />

<strong>ArtNet</strong>-<strong>DMX</strong><br />

<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong><br />

WiFi<br />

Adapter<br />

Configurated as <strong>DMX</strong>-Output<br />

<strong>ArtNet</strong>: Net 0 / Port 2<br />

Configurated as <strong>DMX</strong>-Input<br />

<strong>ArtNet</strong>: Net 0 / Port 2<br />

WiFi<br />

Adapter<br />

<strong>ArtNet</strong>-<strong>DMX</strong><br />

<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong><br />

<strong>DMX</strong><br />

UNIVERSE 1<br />

for example:<br />

NETGEAR WNCE2001<br />

Configurated as <strong>DMX</strong>-Output<br />

<strong>ArtNet</strong>: Net 0 / Port 1<br />

LAN connection<br />

<strong>DMX</strong> connection<br />

WLAN connection


<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 11<br />

Equipment<br />

XLR-cable 3pin<br />

Lenghts:<br />

1m, 5m, 10m, 15m<br />

5m<br />

XLR-adapter<br />

Available in various designs<br />

XLR 3 male – XLR 3 male<br />

XLR 3 male – XLR 5 female<br />

XLR 3 female – XLR 5 male


<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 12<br />

Risk-Notes<br />

You purchased a technical product. Conformable to the best available technology the<br />

following risks should not excluded:<br />

Failure risk: The device can drop out partially or completely at any time without<br />

warning. To reduce the probability of a failure a redundant system structure is<br />

necessary.<br />

Initiation risk: For the installation of the board, the board must be connected and<br />

adjusted to foreign components according to the device paperwork. This work can<br />

only be done by qualified personnel, which read the full device paperwork and<br />

understand it.<br />

Operating risk: The Change or the operation under special conditions of the<br />

installed systems/components could as well as hidden defects cause to breakdown<br />

within the running time.<br />

Misusage risk: Any nonstandard use could cause incalculable risks and is not<br />

allowed.<br />

Warning: It is not allowed to use the device in an operation, where the safety of<br />

persons depend on this device.<br />

<br />

Neutrik ®<br />

EtherCon ®<br />

<strong>ArtNet</strong> <br />

MADRIX ®<br />

is a registered trademark<br />

is a registered trademark<br />

is a trade mark of Alderamin Group Ltd.<br />

is a registered trademark of inoage trade GbR - Germany


<strong>DMX</strong>4ALL <strong>GmbH</strong><br />

Reiterweg 2A<br />

D-44869 Bochum<br />

Germany<br />

© Copyright 2013 <strong>DMX</strong>4ALL <strong>GmbH</strong><br />

All rights reserve. No part of this manual may be reproduced in any form (photocopy, pressure, microfilm or in another<br />

procedure) without written permission or processed, multiplied or spread using electronic systems.<br />

All information contained in this manual was arranged with largest care and after best knowledge. Nevertheless errors are to be<br />

excluded not completely. For this reason I see myself compelled to point out that I can take over neither a warranty nor the<br />

legal responsibility or any adhesion for consequences, which decrease/go back to incorrect data. This document does not<br />

contain assured characteristics. The guidance and the characteristics can be changed at any time and without previous<br />

announcement.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!