<strong>ArtNet</strong>-<strong>DMX</strong><br />
<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong><br />
User Manual<br />
Art-Net Designed by and Copyright Alderamin Group Ltd.
<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 2<br />
Description<br />
The <strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> has a switchable <strong>DMX</strong>-INPUT/<strong>DMX</strong>-OUTPUT<br />
with a 3 pin XLR connectorn. A standard RJ45 connector is used to connect to the<br />
<strong>ArtNet</strong> network<br />
A user-friendly configuration via web browser allows a fast and uncomplicated<br />
adjustment for all parameters.<br />
An additional extension-mode allows an output of 1024 <strong>DMX</strong>-channels on the <strong>DMX</strong>output.<br />
This Extension-mode is optimised for controlling the MagiarLED products.<br />
Data Sheet<br />
Power supply:<br />
5V DC from external power supply (included)<br />
Ethernet:<br />
1x RJ45 (10 BASE-T)<br />
<strong>DMX</strong>:<br />
1x<br />
Neutrik XLR female connector 3 pin<br />
For <strong>DMX</strong>-INPUT operation a <strong>DMX</strong> adapter MALE/MALE is necessary<br />
Dimensions (LxBxH):<br />
75 x 26 x 35 mm
<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 3<br />
Connection<br />
POWER 5V<br />
LED<br />
RESET-button<br />
<strong>DMX</strong>-INPUT /<br />
<strong>DMX</strong>-OUTPUT<br />
Ethernet-connection
<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 4<br />
LED-display<br />
LED green<br />
The green LED flashes if no Ethernet connection exists and shines no-stop if an<br />
Ethernet connection is given.<br />
LED yellow<br />
The yellow LED lights up as soon as data are received.<br />
Configuration<br />
The configuration of the <strong>ArtNet</strong>-<strong>DMX</strong>-<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> occurs about an webinterface<br />
which can be called about any web browser.<br />
The assigned IP-address 2.0.0.10 in the delivery status will be used for the webinterface<br />
as well as for the <strong>ArtNet</strong>.<br />
The network settings of the PC must be<br />
configured to the IP-address 2.0.0.1 and<br />
the subnet mask to 255.0.0.0.<br />
Please consult the <strong>ArtNet</strong>-specifications for<br />
further details.
<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 5<br />
Please call the IP 2.0.0.10 in the address bar of the web browser for getting the<br />
following configuration page:<br />
Each node needs an own IP-address, so the assignment in the network<br />
occurs clearly. According to the <strong>ArtNet</strong>-specifications please use the IPaddresses<br />
2.x.x.x or 10.x.x.x.<br />
Ather IP addresses are also possible, for example 192.168.<strong>1.1</strong>0. Then the<br />
Netmask must be changed to 255.255.255.0 !<br />
For an easier identification you can assign each node with any names.<br />
The Short-name is limited to 18 signs and the Long-name to 64 signs.
<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 6<br />
The Netmask is left to 255.0.0.0 according to the <strong>ArtNet</strong>-specifications.<br />
The Interface mode can be configured as <strong>DMX</strong>-INPUT or <strong>DMX</strong>-OUTPUT.<br />
The Factory settings will be rebuilt by entering the number 7319.<br />
SAVE stores the configuration respectively rebuilt the Factory settings.<br />
<strong>DMX</strong>-Input<br />
For using the <strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> as a <strong>DMX</strong>-INPUT interface please<br />
select the interface mode Set the interface to Input Mode.<br />
Please use a 1:1 MALE-MALE adapter for the connection which is separately<br />
available.<br />
Use Broadcast: <strong>DMX</strong> data is sent ro all <strong>ArtNet</strong> devices<br />
Use Unicast: <strong>DMX</strong> data is sent to one <strong>ArtNet</strong> device witch has the Unicast IP.<br />
In an event of a <strong>DMX</strong>-signal failure (<strong>DMX</strong> FAIL) several actions can be selected for<br />
the <strong>DMX</strong>-input:<br />
NO DATA<br />
- with <strong>ArtNet</strong> no <strong>DMX</strong>-input will be received<br />
HOLD last <strong>DMX</strong> data<br />
- the last data will hold<br />
CLEAR all <strong>DMX</strong> channels to 0% - all <strong>DMX</strong> channels will be set on 0<br />
SET all <strong>DMX</strong> channels to 100% - all <strong>DMX</strong> channels will be set on 255<br />
The Update-rate with whom the <strong>DMX</strong>-input data are outputted can be adjusted in<br />
different times.<br />
On change data transfers the <strong>DMX</strong> data only if it change, however max. every 0,1<br />
seconds.<br />
<strong>DMX</strong> Framerate transfers the <strong>DMX</strong> data when a <strong>DMX</strong> frame is complete received. In<br />
this case the Update-rate is equal to the <strong>DMX</strong> framerate.<br />
<strong>DMX</strong>-Output<br />
For using the <strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> as a <strong>DMX</strong>-OUTPUT interface please<br />
select the interface mode Set the interface to Output Mode.
<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 7<br />
Extension Mode<br />
The <strong>ArtNet</strong>-<strong>DMX</strong>-UNIVERSE <strong>1.1</strong> interface has an extension mode. Then the <strong>DMX</strong>output<br />
is set to 1024 <strong>DMX</strong>-channels. 2 ports (each 512 <strong>DMX</strong>-channels) will be spent<br />
on the <strong>DMX</strong>-output consecutively. Therefore all in all 1024 channels are possible.<br />
For activating the extension mode, please use a web browser.<br />
In the extension mode an additional <strong>ArtNet</strong> port will be activated which has also<br />
512channels.<br />
The <strong>DMX</strong> Routing in the configuration specifies for the <strong>DMX</strong>-output how the data of<br />
the ports are linked together.<br />
The entered value specifies how many <strong>DMX</strong>-channels from the first port should be<br />
spent. After that the <strong>DMX</strong>-channels of the second port will be attached.<br />
Example: <strong>DMX</strong>-Routing = 512<br />
Channel Kanal 1 1 Channel Kanal 512 Channel Kanal 513 513 Channel Kanal 1024<br />
Port Port 11 (512 Channels) Kanäle)<br />
Port Port 2 2 (512 (512 Channels) Kanäle)<br />
Example: <strong>DMX</strong>-Routing = 450<br />
Channel Kanal 11 Channel Kanal 450 450 Kanal Channel 451 451 Channel Kanal 962 962 Channel Kanal 1024<br />
Port Port 1 (450 1 (450 Channels) Kanäle)<br />
Port Port 2 (512 2 (512 Channels) Kanäle)<br />
Channels up to 1024<br />
will be filled with 0<br />
<strong>DMX</strong>-Routing examples<br />
The following examples refer to the application with the indicated products.<br />
Routing Product<br />
511 MagiarLED II Stripe 12xRGB<br />
510 MagiarLED III flex Stripe without configuration channel
<strong>DMX</strong>4ALL-Command support<br />
<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 8<br />
The <strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> interface has an additional communication-port<br />
which can receive the data from TCP-bundle at the port 10001. This port uses the<br />
<strong>DMX</strong>4ALL-Commands in this way, that the <strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> interface<br />
is compatible to the LAN-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong>.<br />
TCP-Control<br />
For control the interface directly with the TCP-connection please use the preset IPaddress<br />
and use the port 10001. The sent and received data are RAW-data bundle.<br />
Please take the <strong>DMX</strong>4ALL-Commands which are possible from the separate<br />
<strong>DMX</strong>4ALL-Command description.<br />
VCP-Control<br />
For the control with a COM-port a TCP-VCP-program must be installed which<br />
provides a virtual Com port (VCP).<br />
We recommend the tool Serial to Ethernet Connection which has been tested by us.<br />
You find this tool on the enclosed CD and as an download in our support-sector.<br />
During the installation you have to<br />
enter a password (see illustration).
<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 9<br />
After the installation start the tool „<br />
Sentos SEC” which is on the<br />
desktop. Now add a VCP with Add<br />
and specify the parameter for the<br />
VCP-port.<br />
Make sure, that you use the IP which<br />
is adjusted about the web browser.<br />
Finally, click Update all in the main<br />
menu window for activating the<br />
VCP. Now, the status became<br />
Available and the COM-port will be<br />
displayed in the device manager.<br />
Factory Reset<br />
The <strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> interface can be reset into the delivery status<br />
with the button next to the RJ45 connector.<br />
Please proceed as follows:<br />
- Power off the device<br />
- Push the button and hold down<br />
- Power on the device<br />
- Green and yellow LED flashes now ca. 10 seconds alternate<br />
- Release the button during the alternate LED flashing<br />
- The reset will be executed and the LEDs flashes 3x simultaneous for<br />
confirmation
<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 10<br />
<strong>DMX</strong> over WLAN<br />
The <strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> can used together with WiiFi components to<br />
transfer the <strong>DMX</strong> data wireless. It is possible to transfer one or more <strong>DMX</strong> universes.<br />
The following drawing show the use of the components:<br />
WiFi<br />
Adapter<br />
<strong>ArtNet</strong>-<strong>DMX</strong><br />
<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong><br />
<strong>DMX</strong><br />
UNIVERSE 1<br />
<strong>DMX</strong><br />
UNIVERSE 1<br />
<strong>ArtNet</strong>-<strong>DMX</strong><br />
<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong><br />
WiFi<br />
Adapter<br />
Configurated as <strong>DMX</strong>-Output<br />
<strong>ArtNet</strong>: Net 0 / Port 1<br />
Configurated as <strong>DMX</strong>-Input<br />
<strong>ArtNet</strong>: Net 0 / Port 1<br />
WiFi<br />
Access<br />
Point<br />
LAN<br />
Switch<br />
<strong>ArtNet</strong>-<strong>DMX</strong><br />
<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong><br />
Configurated as <strong>DMX</strong>-Output<br />
<strong>ArtNet</strong>: Net 0 / Port 1<br />
<strong>DMX</strong><br />
UNIVERSE 1<br />
<strong>ArtNet</strong>-<strong>DMX</strong><br />
<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong><br />
<strong>DMX</strong><br />
UNIVERSE 2<br />
<strong>DMX</strong><br />
UNIVERSE 2<br />
<strong>ArtNet</strong>-<strong>DMX</strong><br />
<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong><br />
WiFi<br />
Adapter<br />
Configurated as <strong>DMX</strong>-Output<br />
<strong>ArtNet</strong>: Net 0 / Port 2<br />
Configurated as <strong>DMX</strong>-Input<br />
<strong>ArtNet</strong>: Net 0 / Port 2<br />
WiFi<br />
Adapter<br />
<strong>ArtNet</strong>-<strong>DMX</strong><br />
<strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong><br />
<strong>DMX</strong><br />
UNIVERSE 1<br />
for example:<br />
NETGEAR WNCE2001<br />
Configurated as <strong>DMX</strong>-Output<br />
<strong>ArtNet</strong>: Net 0 / Port 1<br />
LAN connection<br />
<strong>DMX</strong> connection<br />
WLAN connection
<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 11<br />
Equipment<br />
XLR-cable 3pin<br />
Lenghts:<br />
1m, 5m, 10m, 15m<br />
5m<br />
XLR-adapter<br />
Available in various designs<br />
XLR 3 male – XLR 3 male<br />
XLR 3 male – XLR 5 female<br />
XLR 3 female – XLR 5 male
<strong>ArtNet</strong>-<strong>DMX</strong> <strong>STAGE</strong>-<strong>PROFI</strong> <strong>1.1</strong> 12<br />
Risk-Notes<br />
You purchased a technical product. Conformable to the best available technology the<br />
following risks should not excluded:<br />
Failure risk: The device can drop out partially or completely at any time without<br />
warning. To reduce the probability of a failure a redundant system structure is<br />
necessary.<br />
Initiation risk: For the installation of the board, the board must be connected and<br />
adjusted to foreign components according to the device paperwork. This work can<br />
only be done by qualified personnel, which read the full device paperwork and<br />
understand it.<br />
Operating risk: The Change or the operation under special conditions of the<br />
installed systems/components could as well as hidden defects cause to breakdown<br />
within the running time.<br />
Misusage risk: Any nonstandard use could cause incalculable risks and is not<br />
allowed.<br />
Warning: It is not allowed to use the device in an operation, where the safety of<br />
persons depend on this device.<br />
<br />
Neutrik ®<br />
EtherCon ®<br />
<strong>ArtNet</strong> <br />
MADRIX ®<br />
is a registered trademark<br />
is a registered trademark<br />
is a trade mark of Alderamin Group Ltd.<br />
is a registered trademark of inoage trade GbR - Germany
<strong>DMX</strong>4ALL <strong>GmbH</strong><br />
Reiterweg 2A<br />
D-44869 Bochum<br />
Germany<br />
© Copyright 2013 <strong>DMX</strong>4ALL <strong>GmbH</strong><br />
All rights reserve. No part of this manual may be reproduced in any form (photocopy, pressure, microfilm or in another<br />
procedure) without written permission or processed, multiplied or spread using electronic systems.<br />
All information contained in this manual was arranged with largest care and after best knowledge. Nevertheless errors are to be<br />
excluded not completely. For this reason I see myself compelled to point out that I can take over neither a warranty nor the<br />
legal responsibility or any adhesion for consequences, which decrease/go back to incorrect data. This document does not<br />
contain assured characteristics. The guidance and the characteristics can be changed at any time and without previous<br />
announcement.