26.11.2014 Views

S1276 - Coastal Environmental Systems

S1276 - Coastal Environmental Systems

S1276 - Coastal Environmental Systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Coastal</strong> <strong>Environmental</strong> <strong>Systems</strong>, Inc.<br />

Monitor Your World<br />

Relative Humidity and Air Temperature<br />

<strong>S1276</strong>W / <strong>S1276</strong>Z / <strong>S1276</strong>ZR<br />

Very rugged<br />

+/- 3% RH accuracy<br />

+/- 0.6°C temperature accuracy<br />

The relative humidity and air temperature<br />

sensor is compact and easy to use. The relative<br />

humidity element is a hygroscopic capacitive<br />

type. It is fully interchangeable. These<br />

elements never need calibration. Instead,<br />

elements can be easily replaced without<br />

the expense and inconvenience sometimes<br />

associated with the calibration process. The<br />

membrane filter/mechanical housing of the<br />

sensor protects it from dust and dirt.<br />

Includes Thermilinear Bead for air temperature<br />

measurement.<br />

Advantages of using a thermistor:<br />

Sensitivity – A thermistor is much more<br />

sensitive to temperature change than the<br />

alternative measurement components.<br />

Interchangeability – There are several reasons<br />

for the ability to achieve such tight<br />

interchangeability specifications:<br />

– One is the ability to control the manufacturing<br />

process precisely.<br />

– Another is the sensitivity of the device<br />

itself, which allows for great resolution in<br />

the measurements.<br />

<strong>Coastal</strong> <strong>Environmental</strong> <strong>Systems</strong>, Inc. 820 First Avenue South, Seattle, WA 98134<br />

(800) 488-8291 / (206) 682-6048 / Fax: (206) 682-5658 www.<strong>Coastal</strong><strong>Environmental</strong>.com<br />

Rev 08/16/11


<strong>Coastal</strong> <strong>Environmental</strong> <strong>Systems</strong>, Inc.<br />

Monitor Your World<br />

Technical Specifications<br />

<strong>S1276</strong>W / <strong>S1276</strong>Z / <strong>S1276</strong>ZR<br />

RH Accuracy: +/- 3%<br />

RH Resolution: 0.1%<br />

RH Range:<br />

0 - 100% RH<br />

Operational Temperature Range:<br />

-40°C to +60°C<br />

Storage Temperature:<br />

-80°C to +80°C<br />

AT Accuracy:<br />

+/- 0.6°C<br />

Time Constant, Max:<br />

1 second in well-stirred oil<br />

15 seconds in still air<br />

Shield:<br />

Gill multi-plate naturally ventilated shield<br />

Typical Error In Full Sunlight:<br />

0.5°C<br />