05.11.2012 Views

MAN B&W S50ME-B8-TII Project Guide ... - MAN Diesel & Turbo

MAN B&W S50ME-B8-TII Project Guide ... - MAN Diesel & Turbo

MAN B&W S50ME-B8-TII Project Guide ... - MAN Diesel & Turbo

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MAN</strong> B&W 6.04<br />

<strong>MAN</strong> B&W <strong>S50ME</strong>-<strong>B8</strong>-<strong>TII</strong><br />

Nominal rated engine (L 1 )<br />

High efficiency<br />

turbocharger (TCA)<br />

<strong>MAN</strong> <strong>Diesel</strong><br />

Page 4 of 12<br />

Example 1<br />

Specified MCR (M)<br />

Shaft power at MCR 9,960 kW 8,466 kW<br />

Engine speed at MCR at 127.0 r/min at 114.3 r/min<br />

Power of matching point %MCR 100% 90%<br />

Pumps:<br />

Fuel oil circulating pump m3 /h 4.0 4.0<br />

Fuel oil supply pump m3 /h 2.5 2.5<br />

Jacket cooling water pump m3 /h 88 88<br />

Central cooling water pump m3 /h 265 230<br />

Seawater pump m3 /h 325 278<br />

Lubricating oil pump m3 Coolers:<br />

Scavenge air cooler<br />

/h 205 205<br />

Heat dissipation kW 4,140 3,440<br />

Central water quantity m3 Lub. oil cooler<br />

/h 148 123<br />

Heat dissipation kW 890 816<br />

Lubricating oil quantity m3 /h 205 205<br />

Central water quantity m3 Jacket water cooler<br />

/h 117 107<br />

Heat dissipation kW 1,570 1,389<br />

Jacket cooling water quantity m3 /h 88 88<br />

Central water quantity m3 Central cooler<br />

/h 117 107<br />

Heat dissipation kW 6,600 5,645<br />

Central water quantity m3 /h 265 230<br />

Seawater quantity m3 /h 325 278<br />

Fuel oil heater: kW 105 105<br />

Gases at ISO ambient conditions*<br />

Exhaust gas amount kg/h 89,400 76,200<br />

Exhaust gas temperature °C 245 237.8<br />

Air consumption<br />

Starting air system: 30 bar (gauge)<br />

Reversible engine<br />

kg/s 24.4 20.8<br />

Receiver volume (12 starts) m3 2 x 5.0 2 x 5.0<br />

Compressor capacity, total m3 Non-reversible engine<br />

/h 300 300<br />

Receiver volume (6 starts) m3 2 x 2.5 2 x 2.5<br />

Compressor capacity, total m3 /h 150 150<br />

Exhaust gas tolerances: temperature ±15 °C and amount ±5%<br />

The air consumption and exhaust gas figures are expected and refer to 100% specified MCR,<br />

ISO ambient reference conditions and the exhaust gas back pressure 300 mm WC<br />

The exhaust gas temperatures refer to after turbocharger<br />

* Calculated in example 3, in this chapter<br />

Example 1 – Capacities of derated 6<strong>S50ME</strong>-<strong>B8</strong>-<strong>TII</strong> with high efficiency <strong>MAN</strong> <strong>Diesel</strong> turbocharger type TCA and<br />

central cooling water system.<br />

198 73 50-6.0