BELÜFTUNGSTECHNIK<br />

UMWELT- & VERFAHRENSTECHNIK<br />

SERVICE & WARTUNG<br />

G E N E R A L<br />

I N F O R M A T I O N<br />

OXYFLEX<br />

®<br />

-MT <strong>235</strong><br />

MEMBRANE-DISC-DIFFUSER<br />

For fine bubble aeration of liquids<br />

<strong>Supratec</strong><br />

GESELLSCHAFT FÜR UMWELT-<br />

UND VERFAHRENSTECHNIK MBH<br />

von-Drais-Straße 7<br />

D-55469 Simmern/Hunsrück<br />

Fon: +49 (0) 67 61 9 65 09-00<br />

Fax: +49 (0) 67 61 9 65 09-01<br />

E-mail: info@supratec.cc<br />

Internet: www.supratec.cc


<strong>Supratec</strong><br />

Gesellschaft für Umweltund<br />

Verfahrenstechnik mbH<br />

OXYFLEX®-MT<br />

General<br />

Information<br />

Design<br />

Membrane<br />

<strong>Supratec</strong> Gesellschaft für Umwelt- und Verfahrenstechnik mbH produces modern<br />

high efficient aeration systems, which are mainly used for oxygen transfer into<br />

biological waste water treatment. These products can also be used for any kind of<br />

transfer of gases into liquids<br />

OXYFLEX ® is the brand of <strong>membrane</strong> <strong>diffuser</strong>s (plate, tubes and <strong>disc</strong>s) with a<br />

plastic body.<br />

The extra ordinary characteristics of OXYFLEX ® - MT <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s are<br />

given by its shape and the materials used.<br />

• OXYFLEX ® -MT <strong>235</strong> (free <strong>membrane</strong> area) <strong>235</strong> mm<br />

The body is a round plate, made of glass reinforced made of Polypropylene. The<br />

<strong>membrane</strong> is fixed to this body with a plastic ring made as well of glass reinforced<br />

made of Polypropylene.<br />

Standard-<strong>membrane</strong> is made of EPDM.<br />

Membranes made of Silicone and Polyurethane are partially available.<br />

The <strong>membrane</strong>s have a special slot-arrangement. Size and arrangement of those<br />

slots is optimized to reach maximum oxygen transfer efficiency.<br />

Characteristics<br />

Performance<br />

Combination<br />

Variations<br />

OXYFLEX ® - MT <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s have low pressure loss.<br />

OXYFLEX ® - MT <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s produce fine bubbles of a medium<br />

diameter < 2 mm.<br />

OXYFLEX ® - MT <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s are highly resistant against soiling.<br />

As, in difference to tube <strong>diffuser</strong>s, the whole active <strong>diffuser</strong>s surface is at the same<br />

hydraulic level, the <strong>membrane</strong>s are gazing evenly among the full range from<br />

minimal to maximal air flow. So, lifetime and efficiency is optimized.<br />

OXYFLEX ® - MT <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s can be operated intermittently.<br />

OXYFLEX ® - MT <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s can be used for all geometric forms of<br />

tanks, but they are extraordinarily good for small tanks and grit chambers or first<br />

high loaded stages.<br />

OXYFLEX ® - MT <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s are well established and are working to<br />

the clients satisfaction world-wide.<br />

OXYFLEX ® - MT <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s are compatible to PERMOX ® -T ceramic<br />

<strong>disc</strong> <strong>diffuser</strong>s.<br />

OXYFLEX ® -MT <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s have a wide range, OXYFLEX ® -MT <strong>235</strong>:<br />

0 - 8 Nm³/h.<br />

The design air flow shall be about OXYFLEX ® -MT <strong>235</strong>: 5 ± 1,5 Nm³/h.<br />

OXYFLEX ® -MT <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s can reach specific oxygen transfer<br />

efficiency up to 25 gO 2 /Nm³xm sub , if coverage and water depth is favourable.<br />

For plants with partly intermittent operated tanks, OXYFLEX ® -MT <strong>membrane</strong> <strong>disc</strong><br />

<strong>diffuser</strong>s can be combined with PERMOX ® - T ceramic <strong>disc</strong> <strong>diffuser</strong>s. However,<br />

different pressure losses have to be considered<br />

Modified OXYFLEX ® - MT <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s are also available for drinking<br />

water purposes.<br />

OXYFLEX ® - MT <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s are also available as coarse bubble<br />

<strong>diffuser</strong>s<br />

Stand: December 2009<br />

<strong>Supratec</strong> Von-Drais-Straße 7 • D-55469 Simmern • Fon: +49 (6761) 9 65 09-00 • Fax: 9 65 09-01 • info@supratec.cc • www.supratec.cc


<strong>Supratec</strong><br />

Gesellschaft für Umweltund<br />

Verfahrenstechnik mbH<br />

®<br />

D R A W I N G OXYFLEX MT <strong>235</strong><br />

Membrane - Disc - Diffuser<br />

®<br />

Membrane-<strong>disc</strong>-<strong>diffuser</strong> OXYFLEX -MT <strong>235</strong><br />

are fixed with ist male threat (standard 1“) to<br />

a suitable female threat of the distributor.<br />

Materials:<br />

Body: Polypropylene (PP-GF)<br />

Ring: Polypropylene (PP-GF)<br />

Gasket: EPDM<br />

Membrane: Silicone<br />

EPDM<br />

Membrane area: 0,04 m²<br />

Detail: NON-Returne Valve<br />

Gasket<br />

PP- Body<br />

Air-Socket<br />

Nippel R1"<br />

Membrane<br />

Gasket<br />

Ring PP<br />

Gewinde G 1"<br />

Membrane<br />

OXYFLEX<br />

Stand: December 2009<br />

<strong>Supratec</strong> Von-Drais-Straße 7 • D-55469 Simmern • Fon: +49 (6761) 9 65 09-00 • Fax: 9 65 09-01 • info@supratec.cc • www.supratec.cc


C U R V E S<br />

OXYFLEX -MT <strong>235</strong><br />

MEMBRANE-DISC-DIFFUSER<br />

FOR FINE BUBBLE AERATION OF LIQUIDS<br />

®<br />

<strong>Supratec</strong><br />

Gesellschaft für Umweltund<br />

Verfahrenstechnik mbH<br />

Pressure - Oxygen<br />

®<br />

OXYFLEX -MT <strong>235</strong> <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong> are high efficient <strong>diffuser</strong>s, as they are mainly used for oxygen<br />

supply of biological waste water treatment plants.<br />

Beside procedural necessities important criterions to select the matching fine-bubble aeration-technology<br />

are features of a product.<br />

®<br />

OXYFLEX -MT <strong>235</strong> <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong> are designed at a specific air-flow of 5 Nm³/h per unit.<br />

This is a good compromise between Invest -, overheads and range.<br />

The following table is showing figures, which are represented from an oxygen-efficiency-test.<br />

The values have been reached in a round-basin with water-depth of 3,3 m, submerge of <strong>diffuser</strong>s of 3,02 m<br />

and coverage of 8,4%.<br />

Those values are not transferable on other installations, as the deviation even more than ± 25%.<br />

®<br />

SUPRATEC GmbH likes to produce a data-sheet for individual application-cases on inquiry.<br />

No guarantee-claims can be derived from the diagram! <br />

30<br />

specific O2-entrainment standard conditions and<br />

pressure loss<br />

®<br />

OXYFLEX -MT <strong>235</strong><br />

∆p OC<br />

50<br />

OCL,h [gO2/(Nm³ x m sub)]<br />

25<br />

20<br />

15<br />

40<br />

30<br />

20<br />

∆p [mbar]<br />

10<br />

10<br />

0 2 4 6 8<br />

specific load [Nm/h]<br />

Stand: December 2009<br />

<strong>Supratec</strong> Von-Drais-Straße 7 • D-55469 Simmern • Fon: +49 (6761) 9 65 09-00 • Fax: 9 65 09-01 • info@supratec.cc • www.supratec.cc


I N S T A L L A T I O N<br />

OXYFLEX -MT <strong>235</strong><br />

MEMBRANE-DISC-DIFFUSER<br />

FOR FINE BUBBLE AERATION OF LIQUIDS<br />

®<br />

<strong>Supratec</strong><br />

Gesellschaft für Umweltund<br />

Verfahrenstechnik mbH<br />

M A N U A L<br />

Description<br />

®<br />

OXYFLEX -MT <strong>235</strong> – <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong> has a solid, strengthen,<br />

horizontal body, made of glass-reinforced Polypropylene and a slipped<br />

over <strong>membrane</strong> (e.g.: EPDM).<br />

The uniform ring, made of glass-reinforced Polypropylene ensures the<br />

proper location of the <strong>membrane</strong>.<br />

The body has a connecting-threat (standard 1“-male).<br />

Measurements<br />

Diameter: 255 mm, Height: 30 mm<br />

– (The clamp is not considered in here)<br />

Free <strong>membrane</strong> area: Diameter <strong>235</strong> mm (0,04 m²)<br />

Storage<br />

Preparation<br />

The <strong>diffuser</strong>s shall be stored in their packing inside a dry and aerated<br />

building. DIN 7716 has to be considered<br />

®<br />

Before installation of OXYFLEX -MT <strong>235</strong> – <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong> it<br />

has to be checked that the piping system is clean.<br />

Drilling chips, dirt etc. have to be removed, because those will cause<br />

serious damage to the <strong>diffuser</strong>s’ <strong>membrane</strong>s as those will be transported<br />

into the <strong>diffuser</strong>s as soon as blowers are set into operation.<br />

Levelling<br />

Installation<br />

®<br />

OXYFLEX -MT <strong>235</strong> – <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong> will be installed onto<br />

round pipes. The piping system has to be levelled to maximum ±10 mm.<br />

®<br />

OXYFLEX -MT <strong>235</strong> – <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong> are fixed to the<br />

distributors’ female threat or similar.<br />

It is to be taken care of a horizontal seat of the <strong>diffuser</strong>s.<br />

Between <strong>diffuser</strong> and female threat must be placed a flat gasket made<br />

of EPDM. The surfaces of all parts need to be clean and may not be<br />

damaged.<br />

Stand: December 2009<br />

<strong>Supratec</strong> Von-Drais-Straße 7 • D-55469 Simmern • Fon: +49 (6761) 9 65 09-00 • Fax: 9 65 09-01 • info@supratec.cc • www.supratec.cc


O P E R A T I O N<br />

OXYFLEX -MT <strong>235</strong><br />

MEMBRANE-DISC-DIFFUSER<br />

FOR FINE BUBBLE AERATION OF LIQUIDS<br />

®<br />

<strong>Supratec</strong><br />

Gesellschaft für Umweltund<br />

Verfahrenstechnik mbH<br />

M A N U A L<br />

Function<br />

and<br />

Leakage check<br />

First run of<br />

<strong>diffuser</strong>s<br />

Visual bubble<br />

check<br />

Oxygentransferefficiency<br />

test<br />

Start up<br />

After installation of OXYFLEX ® -MT <strong>235</strong> <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s a<br />

function- and leakage test has to be done.<br />

Therefore the tank shall be filled with clean water up to maximum 10 cm<br />

above <strong>diffuser</strong>s’ surface and the <strong>diffuser</strong>s shall be set in operation.<br />

(specific air flow: 5 Nm 3 /h per unit)<br />

Then function and installation can be checked and confirmed by report.<br />

After function and installation has been checked and confirmed<br />

OXYFLEX ® -MT <strong>235</strong> <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s have to be operated at<br />

least another 60 hours continuously, at a specific air flow of minimum<br />

5 Nm 3 /h per unit.<br />

Water level shall be as quick as possible raised up to minimum 100 cm<br />

above <strong>diffuser</strong>s’ surface.<br />

IMPORTANT: ● Diffusers may not stand still<br />

●<br />

Specific air flow may not exceed 8 Nm 3 /h per unit<br />

The judgement of the visual impression of bubble distribution shall not<br />

take place before the above specified first run of <strong>diffuser</strong>s.<br />

To do the visual check, the <strong>diffuser</strong>s shall operate at maximum capacity<br />

and shall be turned down to the minimum.<br />

•<br />

Test of evenly aeration (visual bubble check) must take place when<br />

the water level is at least 60-100 cm above <strong>diffuser</strong>s surface and a<br />

specific air flow of at least 5 Nm 3 /h per unit.<br />

•<br />

Test of evenly aeration (visual bubble check) at minimum air flow can<br />

only take place if the water temperature is above 10°C.<br />

Before the stated oxygen transfer efficiency figures of OXYFLEX ® -MT<br />

<strong>235</strong> <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s are proved with an the oxygen transfer<br />

efficiency test, the above mentioned steps have to be considered.<br />

The oxygen transfer efficiency test must be done accordingly to<br />

accepted rules (e.g.: ATV-M 209) in clean or waste water.<br />

Guaranty figures have to be controlled exactly. It is necessary to have a<br />

precisely air-flow measurement system.<br />

After successful oxygen transfer efficiency test the start up OXYFLEX ® -<br />

MT <strong>235</strong> <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s may follow immediately. If there is a<br />

postponement of the start up, it has to be taken care, that the water level<br />

stays at least 100 cm above <strong>diffuser</strong>s surface to prevent OXYFLEX ® -MT<br />

<strong>235</strong> <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s from sunlight and / or freezing.<br />

Stand: December 2009<br />

<strong>Supratec</strong> Von-Drais-Straße 7 • D-55469 Simmern • Fon: +49 (6761) 9 65 09-00 • Fax: 9 65 09-01 • info@supratec.cc • www.supratec.cc


M A I N T E N A N C E<br />

OXYFLEX -MT <strong>235</strong><br />

MEMBRANE-DISC-DIFFUSER<br />

FOR FINE BUBBLE AERATION OF LIQUIDS<br />

®<br />

<strong>Supratec</strong><br />

Gesellschaft für Umweltund<br />

Verfahrenstechnik mbH<br />

M A N U A L<br />

Maintenance<br />

Supervision<br />

Warranty<br />

OXYFLEX ® -MT <strong>235</strong> <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s do not need a lot of<br />

maintenance. Usually it is enough to have one run of 10 to 15 minutes<br />

operation at maximum air-flow per day, where each single OXYFLEX ® -<br />

MT <strong>235</strong> <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong> shall operate at a specific air-flow of at<br />

least 5 Nm 3 /h per unit.<br />

To do so, it may help to shut down the system partially, by closing the<br />

corresponding valves.<br />

This also removes layers of sludge after longer time not having<br />

operated the system or longer terms of low specific air flow.<br />

At least once per year OXYFLEX ® -MT <strong>235</strong> <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s<br />

shall be checked visually. Here especially shall be checked whether<br />

there are layers of sludge or similar. If so, those layers shall be removed<br />

carefully.<br />

A separate maintenance-contract can be completed<br />

A Visual bubble check has to be done daily. The pressure loss of the<br />

system has to be controlled and reported monthly.<br />

Showy changes of the bubbles’ distribution and/or of the pressure-loss<br />

are prompt to report at SUPRATEC. Especially at installations with<br />

intermittent operation exists the risk, that activated sludge penetrates<br />

the entire piping, by damaged OXYFLEX ® -MT <strong>235</strong> <strong>membrane</strong> <strong>disc</strong><br />

<strong>diffuser</strong>s. Hereby, all OXYFLEX ® -MT <strong>235</strong> <strong>membrane</strong> <strong>disc</strong> <strong>diffuser</strong>s are<br />

affected in function and lifetime.<br />

The maximum of SUPRATEC GmbH's warranty for Membrane <strong>disc</strong><br />

®<br />

<strong>diffuser</strong> OXYFLEX MT is 24 month.<br />

Longer warranty can be arranged only with conclusion of a maintenance<br />

contract between the operating and SUPRATEC GmbH.<br />

Damages and/or outer influences are specifically excluded from the<br />

warranty promise.<br />

The warranty ends if it known, that sewage is partially mainly full of<br />

industrial origin and/or the sewage has damaging influence on <strong>membrane</strong><br />

<strong>diffuser</strong>s and the SUPRATEC GmbH was not informed accordingly. In such<br />

case, a confirmation of the warranty is to be ordered through the<br />

SUPRATEC GmbH.<br />

The correction of vaults in the warranty is to determine by approval. In<br />

case of warranty starts a 2 year long warranty for the changed <strong>diffuser</strong>s. Is<br />

the first warranty longer running, it apply till it ends.<br />

Stand: December 2009<br />

<strong>Supratec</strong> Von-Drais-Straße 7 • D-55469 Simmern • Fon: +49 (6761) 9 65 09-00 • Fax: 9 65 09-01 • info@supratec.cc • www.supratec.cc


<strong>Supratec</strong><br />

Gesellschaft für Umweltund<br />

Verfahrenstechnik mbH<br />

Here are shown Photos of Membrane-Disc-Diffuser<br />

OXYFLEX MT in operation<br />

<strong>Supratec</strong> Von-Drais-Straße 7 • D-55469 Simmern • Fon: +49 (6761) 9 65 09-00 • Fax: 9 65 09-01 • info@supratec.cc • www.supratec.cc