EASYBus-display and monitoring <strong>de</strong>vice for 20 channels<br />

Front<br />

48 x 96<br />

EB 3000<br />

Specification<br />

E.A.S.Y.Bus<br />

- Modul<br />

Display range: -1999 to +9999 digit<br />

Resolution: automatic <strong>de</strong>tection of resolution and <strong>de</strong>cimal point<br />

of connected sensor modules.<br />

Accuracy: <strong>de</strong>pending on sensor module used. The EB3000 transfers<br />

this value digitally without any additional fault.<br />

Sensor modules: (not inclu<strong>de</strong>d in scope of supply)<br />

all intelligent EASYBus sensor modules as well as EASYLOG can<br />

be connected. 2-wire connection in ring-, tree- or star type. No<br />

polarity.<br />

Sensor supply: via EB 3000<br />

max. bus load: 30 EASYBus standard loads<br />

max. meas. channels: 20<br />

perm. cable length: 500 m (<strong>de</strong>pending on type of cable and wiring)<br />

Switching outputs: 4 relay outputs (make contact), switching to<br />

common terminal.<br />

Outputs can be assigned to any channel<br />

Switching power: 230VAC, 5A, ohm resistive load<br />

Switching function: 2-point controller, 2-point controller inverting<br />

Switching points and <strong>de</strong>lay for each output freely selectable<br />

Alarm output: 1 relay output (change-over contacts)<br />

Switching power: 230VAC, 5A, ohm resistive load<br />

Alarm function: Common alarm for all sensors.<br />

Alarm-settings of the sensors changeable.<br />

Configuration: All standard-functions can be entered and controlled<br />

via keypad.<br />

A confi guration software is available for exten<strong>de</strong>d confi guration<br />

(supported converter is nee<strong>de</strong>d).<br />

Min./Max. value memory: from all connected sensor modules the<br />

max. and min. value are callable via front-si<strong>de</strong> keypad.<br />

Calculation-functions: there are 2 “virtual” channels additionally<br />

to the sensor-channels. A calculated value can be displayed here.<br />

Possible calculation functions: sensor-<strong>de</strong>viation, averaging above<br />

x sensors, etc.<br />

Self diagnosis: permanent self-diagnosis to ensure trouble-free<br />

function. A corresponding fault massages will shown at an error<br />

(e.g. sensor damage, ..)<br />

Display: 4-digit, red, 13mm high LED-display (meas. value),<br />

2-digit, red, 7mm high LED-display (channel display). 11 additional<br />

LEDs to display the unit, switching state or alarm<br />

Interface: EASYBus-interface<br />

with supported converter (e.g. EBW1) GRS232 compatible, for<br />

communication with a PC.<br />

Housing: rack-type housing 48 x 96 x 100mm (H x W x D).<br />

Front: Transparent membrane keyboard IP65. Sealing for housing<br />

for installation according to IP65 will have to be or<strong>de</strong>red separately.<br />

Panel cutout: 43 x 90,5 mm (H x W).<br />

Connection terminals: screw-type/plug-in terminals<br />

Ambient temperature: -25 to 50°C (permissible ambient temperature)<br />

Voltage supply: 230V AC 50/60Hz<br />

Power consumption: approx. 9 VA<br />

• Up to 20 sensor-modules or loggers can be connected<br />

• Sensor module supply and data transfer are carried out<br />

via one single 2-wire line. No additional voltage supply<br />

for sensor modules required.<br />

• 5 relay outputs (4 x controlling, 1 x alarm)<br />

• Controller functions can be assigned to any channel, e.g.:<br />

- 4 x two-point-controllers (of 4 arbitrary sensors)<br />

- 2 x three-point-controllers (of 2 arbitrary sensors)<br />

- 4-way switch (of 1 arbitrary sensor), ....<br />

• 2 calculated channels for displaying:<br />

- average value over more sensors<br />

- difference of 2 sensors<br />

- special functions<br />

• Min-/Max- value memory from all sensors callable<br />

• Alarm monitoring for all connected sensors<br />

• easy confi guration via front-si<strong>de</strong> keypad or via interface<br />

• Via serial interface the connected <strong>de</strong>vices can be read<br />

or additionally be monitored with a PC.<br />

• With EASYBus interface to the PC:<br />

- Up to 1000m cable-length from PC to EB3000 possible<br />

(with interface converter EBW64 or EBW240)<br />

- Additional connection of EASYBus-modules that are<br />

not monitored or connection of a second EB3000 on<br />

the same converter possible.<br />

The EB 3000 <strong>de</strong>vice - cost savings in all areas !<br />

• Short installation time - only one 2-pin line.<br />

• polarity must not be observed by installation<br />

• Minimum material requirement - only one display and<br />

monitoring <strong>de</strong>vice for up to 20 sensor modules<br />

• Minimum time requirement for planning and commissioning<br />

- automatic sensor module <strong>de</strong>tection, expandable for<br />

up to 20 sensor modules of any type.<br />

Accessories<br />

GGD 4896 add. sealing for panel mounting acc. to IP65<br />

Sensor, logger modules p.r.t. page 44, 47 - 50, 60 - 63, 68 -71<br />

for temperature, humidity, norm. signal, frequency, ...<br />

EBW 1 interface converter: EASYBUS to RS232<br />

EBSK 01 connection cable 1m, for EASYLOG, EBN, ...<br />

VSL 2P twisted special cable<br />

per m<br />

for EASYBus-system, cross section 2 x 0,75 mm²<br />

AKL 1P special-branch terminal<br />

or connection to VSL2P, 2 pieces<br />

EASYBus-Configurator<br />

free of charge<br />

software for comfortable editing of all EB3000-parameters.<br />

(downloadable from our homepage: Service --> Download)<br />

Alarm / Protection Temperature probe<br />

Transmitter<br />

Logger / EASYBus Display / Controller Handheld instrument<br />

73