Features<br />

SynchronousdatarecordingwiththeIF2004<br />

With the IF2004 PCI interface card, which is available as an<br />

accessory, the data from up to four sensors can be<br />

synchronously read via aFIFO memory.Readings from an<br />

enco<strong>de</strong>rorlinearmeasurementsystemasthefourthchannel<br />

canbeusedtomapuptothreeLDS85sensors.<br />

Synchronous data recording withtheIF2004<br />

interfacecard<br />

IF2004<br />

enco<strong>de</strong>r<br />

upto 4sensors<br />

Synchronizationoftwosensors<br />

Simultaneousmeasurementusingtwosensorsisnecessary<br />

inor<strong>de</strong>rtoobtainpreciseresults,withthicknessordifferential<br />

measurements,whenthetargetismovingoroscillating.The<br />

LDS85seriessupportsthisfunction,whereonesensoracts<br />

as the master and provi<strong>de</strong>s the clock for the slave.<br />

Consequently, the measurements are always synchronous<br />

andthereforesupplyexactmeasurementresults.<br />

Synchronization oftwo sensors<br />

sensor 1 sensor 1<br />

t d<br />

Highflexcablesratedformovingcabletracks<br />

The type EL-PC 85-xx cables are rated for operation in<br />

movingcabletrackswithaminimumcablebendingradiusof<br />

80mm.<br />

Analoganddigitaloutputs<br />

Withtwoanalogueoutputsignals0...10Vand4...20mAas<br />

well as the serial RS422 interface, the LDS 85 range of<br />

sensorsfulfilsallinterfacerequirements.Thebaudrateofthe<br />

RS422 can be set in standard steps from 9,600 to 115,200<br />

baud. This allows adirect communication to aPLC or any<br />

other host. In addition the dataformat of the serial interface<br />

canbechangedfrombinarytoASCIIcharacteroutput.<br />

Wi<strong>de</strong>inputrange(11...30VDC)<br />

The 11 ... 30 VDC supply also enables operation in 12 V<br />

networks or direct supply from a car's on-board power<br />

supply.<br />

real<br />

thickness<br />

LDS85 with<br />

simultaneoussynchronization<br />

sensor 2 sensor 2<br />

t<br />

error<br />

Commonsensorwith<br />

typicalmeasurement<strong>de</strong>lay<br />

t<br />

Adjustablefilterfunctions<br />

Toachieve the best results for each application,<br />

three different filter functions can be applied to the<br />

measurementresults.<br />

The recursive mean works similar to an analog<br />

low-passfilter.<br />

The moving average enables ahigh dynamic<br />

responseevenwithfiltering.<br />

The median filter is especially suitable for<br />

surfaceswithrandomfalsereadings.<br />

Allfiltersettingsdonotreducetheoutput frequency<br />

(datarate)oftheanaloganddigitaloutputs.<br />

3.5<br />

3<br />

2.5<br />

2<br />

1.5<br />

1<br />

0.5<br />

0<br />

3.5<br />

3<br />

2.5<br />

2<br />

1.5<br />

1<br />

0.,5<br />

oszillation(original)<br />

200<br />

400 600<br />

positionsignal<br />

800<br />

oszillation<br />

moving average (N =128)<br />

1000<br />

8.5<br />

0 200 400 600 800 1000 0 200 400 600 800 1000<br />

positionsignal<br />

positionsignal<br />

11<br />

10.5<br />

10<br />

9.5<br />

9<br />

8.5<br />

0<br />

11<br />

10.5<br />

10<br />

9.5<br />

9<br />

200<br />

profile (original)<br />

400 600<br />

positionsignal<br />

profile<br />

median(N =9)<br />

800<br />

1000<br />

05

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!