08.11.2012 Views

Vtrak 8110/12110/15110 SCSI-SATA RAID Storage Systems

Vtrak 8110/12110/15110 SCSI-SATA RAID Storage Systems

Vtrak 8110/12110/15110 SCSI-SATA RAID Storage Systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

VTrak <strong>15110</strong><br />

15-Drive <strong>SCSI</strong>-<strong>SATA</strong><br />

VTrak <strong>12110</strong><br />

12-Drive <strong>SCSI</strong>-<strong>SATA</strong><br />

VTrak <strong>8110</strong><br />

8-Drive <strong>SCSI</strong>-<strong>SATA</strong><br />

VTrak <strong>8110</strong>/<strong>12110</strong>/<strong>15110</strong><br />

<strong>SCSI</strong>-<strong>SATA</strong> <strong>SCSI</strong> <strong>SATA</strong> <strong>RAID</strong> <strong>Storage</strong> <strong>Systems</strong><br />

High performance, Low-cost Low cost DAS optimized for clustering<br />

Product Highlights<br />

2U/3U rackmount with a cable-less design for higher reliability.<br />

Supports Native Command Queuing (NCQ) and Tagged Command<br />

Queuing (TCQ) for improved performance<br />

Supports multiple LUN carving up to 64 LUNs per subsystem<br />

Optimized for Clustering<br />

- Improved application & data availability (servers and/or storage<br />

are redundant)<br />

- Higher performance (two servers can be load balanced for faster<br />

response times)<br />

Performance<br />

- Up to 20,000 I/Os per second<br />

- Up to 200MB/sec bandwidth<br />

3 Year Warranty (Extensively tested products and high quality ISOapproved<br />

manufacturing)<br />

Key Advantages<br />

Robust Data Protection<br />

- Predictive Data Migration (PDM), Perfect<strong>RAID</strong>, Battery backup, Drive Roaming Metadata (DRM), Media Patrol<br />

Industry Standards Compliance<br />

- Management: WBEM, SNMP and XML<br />

- Host interface: <strong>SCSI</strong><br />

- Architecture: Controller and backplane compliant with <strong>SATA</strong>II cabling and connector standard to ensure off the shelf interoperability<br />

Compatibility<br />

- Promise’s 80%+ market share in ATA <strong>RAID</strong> provides the foundation of extensive drive and OS compatibility<br />

- Extensive qualification of third party <strong>SCSI</strong> HBAs/Controllers, switches and backup software<br />

Modular architecture – The VTrak series of <strong>RAID</strong> storage systems share the same:<br />

- Graphical user interface (GUI) –Same look and feel when configuring and managing the system<br />

Freedom of Choice: Choose the capacity and brand of hard disk drives in your VTrak product<br />

- End Users: Save money with drives that are suitable for your application. Upgradeable as your storage needs increase.<br />

- System Integrators and Value-Added Resellers: Increase your margins by selecting drives purchased at the lowest cost.<br />

Tested by leading HDD vendors for drive compatibility and reliability


Product Information<br />

Feature Set<br />

- HW <strong>RAID</strong> 0,1,10,5,50<br />

- Full remote monitoring and management<br />

of all functions, status and alerts<br />

- Global and Dedicated Hot Spares<br />

- Online Capacity Expansion (OCE)<br />

- <strong>RAID</strong> and Stripe Level Migration (RLM)<br />

- Capacity Coercion<br />

- Robust data and error handling - Write<br />

hole prevention, Read Check Table,<br />

SMART and Multi-dead prevention<br />

- Non-Volatile error logging<br />

- Cluster support with dual IDs per array<br />

- LUN Mapping<br />

- Metadata On Disk (MDD) support drive<br />

roaming within the enclosure or drive<br />

group roaming between subsystems<br />

- Predictive Data Migration (PDM)<br />

preemptively detects possible drive loss<br />

and migrates data ahead of failure<br />

- Bad sector remapping and management<br />

- Read cache, Write cache, write back &<br />

write through modes<br />

- Background Activities – Rebuild,<br />

Initialization, Synchronization,<br />

Redundancy (consistency) Check,<br />

Media Patrol, Bad block management<br />

VTrak <strong>8110</strong>/<strong>12110</strong>/<strong>15110</strong><br />

<strong>SCSI</strong>-<strong>SATA</strong> <strong>SCSI</strong> <strong>SATA</strong> <strong>RAID</strong> <strong>Storage</strong> <strong>Systems</strong><br />

Management Software<br />

– Remotely manage multiple Promise arrays in same<br />

interface from ANY computer on the web<br />

– Full remote monitoring and management of all<br />

functions, status and alerts<br />

– Remote notification and alerts<br />

– Out of Band Management through Management<br />

Ethernet port or RS-232<br />

– SNMP, WBEM/ Standards support<br />

– CLU over RS-232 or Telnet<br />

– HTTP Web based HTML GUI<br />

– SSL security, User Access privilege control and authentication<br />

Controller<br />

– Industry standard <strong>SATA</strong>2 controller and backplane enclosure design<br />

– High performance 600 MHz Intel ® 80321 I/O Processor with PCI-X<br />

internal bus, HW XOR assist and local memory control<br />

– Two intelligent Ultra160 <strong>SCSI</strong> ports<br />

– One 10/100 Ethernet port for out of band LAN based Management<br />

– One RS-232 for configuration CLI<br />

– 256MB DDR DRAM data cache, supports up to 512<br />

– 72 Hour Battery Backup Unit standard<br />

<strong>SCSI</strong> Controller


Product Information (cont’d)<br />

Front View<br />

Drive Carriers<br />

Drive Carrier<br />

Latch Handle<br />

Back View<br />

Controller<br />

VTrak<br />

Chassis<br />

<strong>Storage</strong><br />

Enclosure<br />

Processor<br />

Power<br />

FRU Status<br />

Ethernet<br />

Interface<br />

Logical Drive<br />

Status<br />

<strong>SCSI</strong><br />

Ports<br />

Cooling Units<br />

Power Supplies<br />

<strong>SCSI</strong>-1<br />

Activity<br />

<strong>SCSI</strong>-2<br />

Activity<br />

VTrak <strong>8110</strong>/<strong>12110</strong>/<strong>15110</strong><br />

<strong>SCSI</strong>-<strong>SATA</strong> <strong>SCSI</strong> <strong>SATA</strong> <strong>RAID</strong> <strong>Storage</strong> <strong>Systems</strong><br />

VTrak <strong>15110</strong><br />

Controller<br />

Activity<br />

Serial<br />

Interface<br />

VTrak <strong>15110</strong><br />

Enclosure Hardware<br />

– 2U/3U enclosures<br />

– 8, 12, 15 drive bays<br />

– Hot swappable Field Replaceable Units<br />

(FRUs): power supplies, fans, disk<br />

drives and carriers (2U and 3U<br />

components differ)<br />

– Hot swappable IO Controller<br />

– Completely cable-less design for all<br />

components<br />

– Dual N+1 redundant PSUs<br />

– Dual N+1 redundant cooling units with<br />

dual blowers and one battery<br />

Drive Carrier<br />

– Hot swap drive carriers for 3.5” x 1”<br />

drive form factor<br />

– Direct <strong>SATA</strong> drive connection to the<br />

backplane<br />

– PATA Drive Connectivity requires<br />

optional Promise Adapter<br />

– Drive status and activity LED<br />

– Positive camming action ensures<br />

reliability<br />

Drive Carrier


<strong>SCSI</strong> DAS Applications<br />

<strong>SCSI</strong> DAS<br />

<strong>SCSI</strong> Two server DAS<br />

Server<br />

(e.g. E-mail server)<br />

Connected to<br />

<strong>SCSI</strong> 1 Port<br />

Server<br />

(e.g. E-mail server)<br />

VTrak <strong>15110</strong><br />

VTrak <strong>15110</strong><br />

(Connect second<br />

<strong>SCSI</strong> channel to<br />

increase sustained<br />

throughput)<br />

Server<br />

(e.g. Web server)<br />

Connected to<br />

<strong>SCSI</strong> 2 Port<br />

VTrak <strong>8110</strong>/<strong>12110</strong>/<strong>15110</strong><br />

<strong>SCSI</strong>-<strong>SATA</strong> <strong>SCSI</strong> <strong>SATA</strong> <strong>RAID</strong> <strong>Storage</strong> <strong>Systems</strong><br />

<strong>SCSI</strong> Two server DAS Cluster<br />

Two node clustering configuration<br />

- Brand new market for truly low cost clusters<br />

- Customers can buy two servers and storage vs. only one<br />

- Environments where simplicity and price are critical<br />

- Upgrading internal <strong>RAID</strong> storage for higher capacity, performance and protection<br />

- 1-2 CPU IA servers<br />

Improved application &<br />

data availability<br />

(servers and/or storage are<br />

redundant)<br />

Higher performance<br />

(two servers can be load balanced<br />

for faster response times)<br />

Server<br />

(e.g. File server)<br />

VTrak <strong>15110</strong><br />

Server<br />

(e.g. E-mail server)<br />

Connected to<br />

<strong>SCSI</strong> 1 Port<br />

Multiple VTrak DAS<br />

6 foot maximum total<br />

cable length connecting<br />

all systems<br />

Clustered<br />

VTrak <strong>15110</strong><br />

Server<br />

(e.g. E-mail server)<br />

Connected to<br />

<strong>SCSI</strong> 2 Port<br />

Up to 8<br />

systems<br />

per <strong>SCSI</strong><br />

channel

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!