<strong>Proclear</strong>® <strong>Multifocal</strong><br />
Featuring easy to fit Balanced Progressive Technology<br />
Balanced Progressive Technology <strong>com</strong>bines spherical <strong>and</strong> aspheric optics <strong>and</strong> unique<br />
zone sizes to produce two different lenses – a D lens for the dominant eye <strong>and</strong> an N lens<br />
for the non-dominant eye. These two lenses work together to provide great vision quality.<br />
• Simple to fit with no <strong>com</strong>plicated<br />
spectacle Rx conversion required<br />
• Balanced Progressive Technology<br />
maximises binocular visual acuity<br />
at all distances –<br />
near, intermediate <strong>and</strong> far<br />
• Utilises the unique PC Technology<br />
Fitting procedure<br />
Near<br />
Vision<br />
D Lens: Dominant eye<br />
Spherical Central<br />
Zone: 2.3 mm<br />
Aspheric Annular<br />
Zone: 5.0 mm<br />
Spherical Annular<br />
Zone: 8.5 mm<br />
Lens Edge<br />
Distance<br />
Vision<br />
Distance<br />
Vision<br />
N Lens: Non-dominant eye<br />
Spherical Central<br />
Zone: 1.7 mm<br />
Aspheric Annular<br />
Zone: 5.0 mm<br />
Spherical Annular<br />
Zone: 8.5 mm<br />
Lens Edge<br />
Near<br />
Vision<br />
1. With the full distance prescription in place, view<br />
a distant object. Fog each eye in turn using the patient’s<br />
spectacle Add power. One eye should notice a greater<br />
blur than the other (Blur suppression test).<br />
2. To determine each lens power, take the vertex adjusted<br />
best vision sphere <strong>and</strong> Add power from the spectacle<br />
prescription.<br />
3. Apply the ‘D’ lens to the eye that notices the greatest<br />
blur in step 1 <strong>and</strong> the ‘N’ lens to the opposite eye.<br />
Allow at least 10 minutes to equilibrate.<br />
4. Test visual acuity binocularly without occlusion <strong>and</strong> over<br />
refract each eye independently with h<strong>and</strong> held lenses.<br />
5. Book a one week follow up with wearer to confirm<br />
satisfactory results in the real world.<br />
One Week follow-up<br />
1. If the fit <strong>and</strong> acuity are acceptable, order lens.<br />
2. If unacceptable, re-evaluate using CooperVision<br />
‘Hints <strong>and</strong> Tips’ guide, <strong>and</strong> return to step 5.<br />
Water content: 62% 59%<br />
Manufacturing process: Fully cast moulded FIPS<br />
Base curve:<br />
Diameter:<br />
Spherical powers:<br />
<strong>Proclear</strong> ® <strong>Multifocal</strong> <strong>Proclear</strong> ® <strong>Multifocal</strong> XR<br />
8.7mm<br />
14.4mm<br />
+6.00 to -8.00DS<br />
(0.50 steps after -6.50DS)<br />
+20.00DS to -20.00DS<br />
(0.50 steps after +/- 6.50DS)<br />
Add: +1.00 to 2.50 (0.50 steps) +1.00 to +4.00 (0.50 steps)<br />
Lens types:<br />
Distance (DI & Near (N) lenses<br />
Centre thickness (@-3.00DS): 0.16mm Varies by Rx<br />
Dk (ISO 9913-1 – 1998): 27 25<br />
Dk/t (@-3.00DS): 17 Varies by Rx<br />
Wear indications:<br />
Daily wear<br />
H<strong>and</strong>ling tint:<br />
Light blue<br />
Pack size:<br />
Trial lens:
<strong>Proclear</strong>® <strong>EP</strong><br />
Performs like a multifocal, fits like a sphere<br />
<strong>Proclear</strong> <strong>EP</strong> is designed specifically for the visual needs of the early presbyope.<br />
The lens has a centre spherical distance zone with a progressive aspheric zone that provides<br />
excellent intermediate <strong>and</strong> near vision.<br />
• As simple to fit as a sphere<br />
• <strong>Spec</strong>ifically designed for patients<br />
with up to +1.25 Add<br />
• Perfect way to introduce patients<br />
to multifocal contact lenses, making<br />
the transition into Balanced<br />
Progressive Technology easier<br />
as their condition progresses<br />
Spherical distance<br />
vision<br />
Aspheric intermediate<br />
<strong>and</strong> near vision (8.5mm)<br />
• Utilises the unique PC Technology<br />
Fitting procedure<br />
Lens Edge<br />
• Fit using the spectacle Rx<br />
• Vertex sphere if over +/- 4.00D<br />
• No need to determine eye dominance<br />
• No need to <strong>com</strong>pensate for Add (assuming patient’s Add is not above +1.25D)<br />
• Leave the lights on in the exam room to eliminate pupil dilation<br />
• Use loose trial lenses for the over refraction (+/- 0.25D), do not use a phoropter<br />
<strong>Proclear</strong> ®<br />
<strong>EP</strong><br />
Water content: 60%<br />
Manufacturing process:<br />
Fully cast moulded<br />
Base curve:<br />
8.7mm<br />
Diameter:<br />
14.4mm<br />
Power range:<br />
+6.00 to -8.00DS (0.50 steps after -6.50DS)<br />
Add:<br />
Suitable for upto a +1.25 add<br />
Centre thickness (@-3.00DS):<br />
0.16mm<br />
Dk (ISO 9913-1 – 1998): 25<br />
Dk/t (@-3.00DS): 16<br />
Wear indications:<br />
Daily wear<br />
H<strong>and</strong>ling tint:<br />
Light blue<br />
Pack size:<br />
Trial lens:<br />
For further information contact Customer Services<br />
Tel: 0000 0000 000 Fax: 0000 0000 000 www.coopervision.<strong>com</strong><br />
<strong>EP</strong> E