6. ELECTRONIC TRANSMITTER (-E)<br />
The buttons access three functions:<br />
- upper button ( ↑ ) : Exit setting mode<br />
- lower button ( → ) : Scroll through menu/selection of parameters<br />
- both buttons ( ↑ + → ) = Enter : Entering parameters/selecting setting mode<br />
If no button is pressed for one minute while the operating menu is active, the indication reverts to the<br />
measuring indication. This does not apply to subfunctions F32, F33, F52, F63.<br />
For indication of volume or mass values at maximum 6 digits in front of the decimal point and 7 decimals are<br />
used. This format allows an indication range for flow rates from 0.0000001 uni/time to 106000 unit/time. Flow<br />
rate values exceeding 106000 are shown as ‘————’ on the display. In this case the next bigger flow rate<br />
unit (next smaller time unit) has to be selected.<br />
For the indication of totaliser values 8 digits are used at maximum of which 7 digits can be assigned for<br />
decimal values. The decimal point setting is determined by selecting the unit. Therefore, possible totaliser<br />
offsets are:<br />
Unit *1<br />
Unit *1/10<br />
Unit *1/100<br />
The totaliser counts up to 99999999 or 9999999.9 or 999999.99 and is reset to zero.<br />
The next page shows the operating menu.<br />
The following describes selection and execution of functions.<br />
IM 01R01B02-00E-E<br />
9th edition, July 2007<br />
6-2