03.01.2015 Views

Hybrid - Ecotechnics

Hybrid - Ecotechnics

Hybrid - Ecotechnics

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3<br />

All our services<br />

PATENT PENDING PATENT PENDING PATENTED PATENTED<br />

Saniflux <strong>Hybrid</strong> Diag Nitro Hermetic<br />

The first A/C system and<br />

passenger compartment<br />

air purification system fully<br />

integrated in a charging<br />

station. 2 services in a single<br />

station!<br />

<strong>Ecotechnics</strong>’ patented singlestation<br />

solution for charging<br />

standard, hybrid and electric<br />

vehicles, and vehicles with<br />

electric compressors.<br />

Integrated system for<br />

diagnosis of electromechanical<br />

problems on A/C<br />

systems, featuring printout<br />

of diagnosis and problem<br />

solutions.<br />

A/C system leak testing by<br />

charging with nitrogen from an<br />

external bottle (not included)<br />

and monitoring pressure drops,<br />

with leak alarm.<br />

Collapsible, hermetic<br />

cartridges offer full protection<br />

against ambient humidity for<br />

oil and dye, to guarantee full<br />

product efficiency.


4<br />

The first air purification system integrated<br />

in an A/C charging station


5<br />

Saniflux<br />

PATENT PENDING<br />

The Saniflux integrated<br />

system applies ultrasound<br />

technology (the same used<br />

in aerosols) to passenger<br />

compartment air purification<br />

and evaporator sanitising, to<br />

eliminate annoying odours<br />

and infuse a pleasant scent.<br />

With the certified Saniflux<br />

Liquid in the tank, select the<br />

service time from the station<br />

menu according to vehicle<br />

type (small, medium, large)<br />

and start treatment, which may<br />

be carried out simultaneously<br />

with A/C system charging in full<br />

automation.<br />

The passenger compartment<br />

air purification treatment<br />

uses a long hose, with a<br />

terminal drip-catcher, to<br />

permit directing the flow of<br />

nebulised product toward the<br />

evaporator, where bacteria,<br />

moulds, and other irritants<br />

and allergens may hide.<br />

The concentrated, continuous<br />

flow guarantees highlyeffective<br />

and long-lasting<br />

bactericide treatment.


6<br />

Suitable for all hybrid vehicles<br />

<strong>Hybrid</strong><br />

PATENT PENDING<br />

The new A/C systems on<br />

many latest-generation<br />

vehicles, such as hybrid or<br />

electric vehicles, are equipped<br />

with compressors operated<br />

by high-voltage electric<br />

motors containing a specific<br />

high-performance electrical<br />

insulating oil.<br />

Use of other oils may prove<br />

dangerous for the operator<br />

during system testing if high<br />

voltages are present.<br />

Preliminary flushing of the<br />

station and the service hoses<br />

is recommended before<br />

servicing a system of this<br />

type. Flushing eliminates the<br />

risk that residues of different<br />

(non-insulating) oils may be<br />

injected into the A/C system,<br />

jeopardising its safety and<br />

good operation.<br />

The patented <strong>Ecotechnics</strong><br />

system permits running this<br />

flushing cycle automatically,<br />

thanks to the specific lateral<br />

couplings, integrated with the<br />

station, for connecting the<br />

service hoses.


7<br />

Diag<br />

PATENTED<br />

The importance of patented<br />

diagnosis in recycling stations<br />

Diagnosis is an increasingly critical tool for anyone - climatecontrol<br />

specialists and not - wanting to expand their business<br />

to include A/C system repair. <strong>Ecotechnics</strong> offers the following<br />

patented solutions:<br />

1 Static Diagnosis 2<br />

The station uses the<br />

pressure and temperature<br />

values entered by the<br />

operator to perform<br />

automatic diagnosis.<br />

Dynamic Diagnosis<br />

With the pressure and<br />

temperature sensors A/C<br />

connected to the system, the<br />

station conducts analysis<br />

with no further need of<br />

operator intervention. The<br />

station prints a report for<br />

each type of diagnosis.<br />

ALL THE ADVANTAGES<br />

• Easy to use<br />

• Fast, accurate diagnosis<br />

• Printout of diagnosis and list<br />

of remedial actions<br />

• Reliability<br />

• Perfect integration with the<br />

stations


8<br />

Nitrogen leak testing<br />

Nitro<br />

The nitrogen leak testing system is an alternative to traditional<br />

leak detection methods (testing during the vacuum phase or<br />

dye injection). The advantage offered by nitrogen is that leak<br />

testing may be conducted under pressure with an inert gas. It<br />

is useful above all in those cases in which use of a dye is not<br />

permissible (for example, in automobile manufacturing).<br />

This system is fully integrated with the <strong>Ecotechnics</strong> recharging<br />

stations to eliminate the need for operator intervention during<br />

service. The system prints a leak test report at the end of<br />

testing.


9<br />

Hermetic<br />

PATENTED<br />

Hermetic oil and dye cartridges<br />

An A/C station equipped with<br />

hermetic cartridges offers<br />

the advantage of eliminating<br />

contact between the humidity<br />

naturally present in ambient<br />

air and the oil or dye, which<br />

are hygroscopic substances<br />

(that is, substances that easily<br />

absorb humidity).<br />

The collapsible, accordiontype<br />

hermetic cartridges<br />

guarantee the high quality<br />

of the product charged<br />

and protect the internal<br />

components of the station<br />

from possible damage from<br />

oils and/or dyes of uncertain<br />

provenance. Moreover,<br />

many vehicle manufacturers<br />

recommend use of hermetic<br />

cartridges in their authorised<br />

repair shops.


10<br />

Eck 800<br />

Fully automatic station<br />

for recovering, recycling,<br />

and recharging R134a refrigerant.<br />

Eck 890<br />

Type of refrigerant<br />

R134a<br />

Service procedure<br />

Fully automatic or manual<br />

Voltage<br />

50/60 Hz<br />

Scale resolution<br />

10 g<br />

Oil scale resolution 5 g<br />

Working temperature range 11/49°C<br />

Filter system<br />

1 filter for humidity<br />

Vacuum pump<br />

72 litre/min capacity, 0.1 mbar vacuum level<br />

Compressor<br />

Hermetically sealed, 12 cc, high pressure<br />

Recovery speed<br />

300 g/min in liquid phase<br />

Refrigerant bottle<br />

12 litres, refillable<br />

Hoses<br />

3 metres<br />

Overall size<br />

55 x 60 x 105 cm<br />

Weight<br />

80 kg<br />

Thermal printer<br />

Optional<br />

Pressure gauges Class 1<br />

Bottle pressure gauge Class 2.5<br />

Display<br />

Graphic<br />

Bottle temperature sensor Integrated<br />

Bottle heater<br />

Optional


11<br />

High precision<br />

<strong>Ecotechnics</strong> technology<br />

for maximum precision in<br />

recovery and recharging.<br />

Automatic Leak Testing<br />

The station checks for leaks<br />

during the vacuum phase. If<br />

leaks are found, it interrupts<br />

operation and gives an alarm.<br />

Refrigerant Management<br />

Each service is saved in<br />

station memory, offering<br />

the option of creating a<br />

customised archive of all<br />

refrigerant transactions.<br />

Database<br />

Automobile + truck database<br />

with user option to enter new<br />

vehicle models.<br />

Graphic Display<br />

Multi-language, new<br />

generation.<br />

STANDARD FEATURES<br />

OPTIONS<br />

Thermal Printer<br />

For a complete, detailed<br />

report.<br />

Automatic Bottle Heater<br />

For fast recharging at high or<br />

low ambient temperatures.<br />

Automatic Dye Injection<br />

With refillable cartridges and<br />

electronic scale.


12<br />

Eck 1000-up<br />

Fully automatic station for<br />

recovering, recycling, and<br />

recharging R134a refrigerant.<br />

SPECULARE<br />

rispetto alla foto<br />

originale<br />

Eck 1090-up<br />

Type of refrigerant R134a<br />

Service procedure Fully automatic or manual<br />

Voltage<br />

220-240V 50/60 Hz<br />

Scale resolution 10 g<br />

Oil scale resolution 5 g<br />

Working temperature range 11/49°C<br />

Filter system<br />

2 filters for humidity<br />

Vacuum pump<br />

100 litre/min capacity, 0.1 mbar vacuum level<br />

Compressor<br />

Hermetically sealed, 12 cc, high pressure<br />

Recovery speed<br />

300 g/min in liquid phase<br />

Refrigerant bottle 12 litres, refillable<br />

Hoses<br />

3 metres<br />

Overall size<br />

55 x 60 x 105 cm<br />

Weight<br />

80 kg<br />

Thermal printer<br />

Standard equipment<br />

Pressure gauges Class 1<br />

Bottle pressure gauge Class 2,5<br />

Display<br />

Graphic<br />

Bottle temperature sensor Integrated<br />

Bottle heater<br />

Standard equipment


13<br />

Refrigerant Management<br />

Each service is saved in<br />

station memory, offering<br />

the option of creating a<br />

customised archive of all<br />

refrigerant transactions.<br />

Thermal Printer for a<br />

complete, detailed report.<br />

STANDARD FEATURES<br />

OPTIONS<br />

Automatic Dye and Oil<br />

Injection with electronic<br />

scale and hermetic cartridges<br />

to protect the contents<br />

against contact with ambient<br />

humidity. (PATENTED)<br />

HFO UPgradable option<br />

of upgrading the charging<br />

station for use with the new<br />

HFO1234yf refrigerant, using<br />

a specific kit.<br />

Graphic Display<br />

multi-language, new<br />

generation.<br />

Diag<br />

Static diagnosis kit.<br />

Flushing kit<br />

For cleaning A/C systems by<br />

flushing with refrigerant.<br />

PATENTED<br />

PATENTED


14<br />

Eck 2500-up<br />

Fully automatic station for<br />

recovering, recycling, and<br />

recharging R134a refrigerant.<br />

Eck 2900-up<br />

Type of refrigerant R134a<br />

Service procedure Fully automatic or manual<br />

Voltage<br />

220-240V 50/60 Hz<br />

Scale resolution 10 g<br />

Oil scale resolution 5 g<br />

Working temperature range 11/49°C<br />

Filter system<br />

2 filters for humidity<br />

Vacuum pump<br />

100 litre/min capacity, 0.1 mbar vacuum level<br />

Compressor<br />

Hermetically sealed, 12 cc, high pressure<br />

Recovery speed<br />

300 g/min in liquid phase<br />

Refrigerant bottle 22 litres, refillable<br />

Hoses<br />

3 metres<br />

Overall size<br />

55 x 60 x 105 cm<br />

Weight<br />

80 kg<br />

Thermal printer<br />

Standard equipment<br />

Pressure gauges Class 1<br />

Display<br />

Graphic<br />

Bottle temperature sensor Integrated<br />

Bottle heater<br />

Standard equipment


15<br />

High precision<br />

<strong>Ecotechnics</strong> technology<br />

for maximum precision in<br />

recovery and recharging.<br />

Automatic Taps on high and<br />

low pressure lines for simpler,<br />

more practical use.<br />

STANDARD FEATURES<br />

OPTIONS<br />

Automatic Discharge of<br />

non-condensable gases via<br />

solenoid valves, with bottle<br />

temperature and pressure<br />

sensors. (PATENT PENDING)<br />

HFO UPgradable option<br />

of upgrading the charging<br />

station for use with the new<br />

HFO1234yf refrigerant, using<br />

a specific kit.<br />

Automatic Dye and Oil<br />

Injection with electronic<br />

scale and hermetic cartridges<br />

to protect the contents<br />

against contact with ambient<br />

humidity. (PATENTED)<br />

Saniflux<br />

Integrated passenger<br />

compartment air purification<br />

system.<br />

Diag<br />

Static diagnosis module.<br />

Dynamic diagnosis module.<br />

Nitro<br />

Automatic leak testing with<br />

nitrogen.<br />

<strong>Hybrid</strong><br />

Flushing of station and<br />

service hoses for use with<br />

vehicles equipped with electric<br />

compressors.<br />

Flushing kit<br />

For cleaning A/C systems by<br />

flushing with refrigerant.<br />

PATENT PENDING<br />

PATENTED<br />

PATENT PENDING<br />

PATENTED


16<br />

➜ Fast changeover from one<br />

gas to another<br />

➜ Protection against crosscontamination<br />

thanks to<br />

separate circuits for the 2<br />

gases<br />

➜ User savings<br />

➜ Compact design, 2-in-1<br />

station<br />

➜ 4 pressure gauges<br />

➜ 7” colour touch screen<br />

display<br />

➜ Automatic discharge of<br />

non-condensable gases<br />

➜ Automatic service taps<br />

➜ 2 pairs of service hoses<br />

➜ 4 separate lines for oil and<br />

dye<br />

➜ 2 compressors<br />

➜ Simple filter replacement<br />

➜ High-capacity fan / air<br />

exhaust<br />

Eck twin<br />

PATENT PENDING<br />

Fully automatic Dual-Gas station<br />

for recovering, recycling, and<br />

recharging R134a and HFO1234yf<br />

refrigerants.<br />

Type of refrigerant R134a and HFO1234yf<br />

Service procedure Fully automatic or manual<br />

Voltage<br />

220-240V - 50 Hz<br />

Scale resolution 10 g<br />

Oil scale resolution 5 g<br />

Working temperature range 11/49°C<br />

Filter system<br />

2 filters for humidity<br />

Vacuum pump<br />

100 litre/min capacity, 0.1 mbar vacuum level<br />

Compressor<br />

Hermetically sealed, 2x12 cc, high pressure<br />

Recovery speed<br />

300 g/min in liquid phase<br />

Refrigerant bottle 2x12 litres, refillable<br />

Hoses<br />

2 pairs, each 3 metres<br />

Overall size<br />

67 x 62 x 107 cm<br />

Weight<br />

110 kg<br />

Thermal printer<br />

Standard equipment<br />

Pressure gauges Class 1<br />

Display<br />

Colour graphic, touch screen<br />

Bottle temperature sensor Integrated<br />

Bottle heater<br />

Automatic


17<br />

Large 7” Colour Display with<br />

touch-screen icon messaging<br />

for easy use.<br />

Automatic Discharge of<br />

non-condensable gases via<br />

solenoid valves, with bottle<br />

temperature and pressure<br />

sensors. (PATENT PENDING)<br />

Automatic Leak Testing<br />

The station checks for leaks<br />

during the vacuum phase. If<br />

leaks are found, it interrupts<br />

operation and gives an alarm.<br />

Automatic Dye and Oil<br />

Injection with electronic<br />

scale and hermetic cartridges<br />

to protect the contents<br />

against contact with ambient<br />

humidity. (PATENTED)<br />

Automatic Taps on high and<br />

low pressure lines for simpler,<br />

more practical use.<br />

STANDARD FEATURES<br />

OPTIONS<br />

<strong>Hybrid</strong><br />

Flushing of station and<br />

service hoses for use with<br />

vehicles equipped with electric<br />

compressors.<br />

Flushing kit<br />

For cleaning A/C systems by<br />

flushing with refrigerant.<br />

PATENT PENDING<br />

PATENTED


18<br />

Eck 2500-hfo<br />

Fully automatic station for recovering,<br />

recycling, and recharging HFO1234yf<br />

refrigerant.<br />

Eck 2900-hfo<br />

Type of refrigerant HFO1234yf<br />

Service procedure Fully automatic or manual<br />

Voltage<br />

220-240V - 50 Hz<br />

Scale resolution 10 g<br />

Oil scale resolution 5 g<br />

Working temperature range 11/49°C<br />

Filter system<br />

2 filters for humidity<br />

Vacuum pump<br />

100 litre/min capacity, 0.1 mbar vacuum level<br />

Compressor<br />

Hermetically sealed, 12 cc, high pressure<br />

Recovery speed<br />

300 g/min in liquid phase<br />

Refrigerant bottle 12 litres, refillable<br />

Hoses<br />

3 metres<br />

Overall size<br />

55 x 60 x 105 cm<br />

Weight<br />

80 kg<br />

Thermal printer<br />

Standard equipment<br />

Pressure gauges Class 1<br />

Display<br />

Graphic<br />

Bottle temperature sensor Integrated<br />

Bottle heater<br />

Automatic


19<br />

High precision<br />

<strong>Ecotechnics</strong> technology<br />

for maximum precision in<br />

recovery and recharging.<br />

Automatic Taps on high and<br />

low pressure lines for simpler<br />

more practical use.<br />

STANDARD FEATURES<br />

OPTIONS<br />

Automatic Discharge of<br />

non-condensable gases via<br />

solenoid valves, with bottle<br />

temperature and pressure<br />

sensors. (PATENT PENDING)<br />

Automatic Leak Testing<br />

The station checks for leaks<br />

during the vacuum phase. If<br />

leaks are found, it interrupts<br />

operation and gives an alarm.<br />

Automatic Dye and Oil<br />

Injection with electronic<br />

scale and hermetic cartridges<br />

to protect the contents<br />

against contact with ambient<br />

humidity. (PATENT PENDING)<br />

Saniflux<br />

Integrated passenger<br />

compartment air purification<br />

system.<br />

Nitro<br />

Automatic leak testing with<br />

nitrogen.<br />

<strong>Hybrid</strong><br />

Flushing of station and<br />

service hoses for use with<br />

vehicles equipped with electric<br />

compressors.<br />

Flushing kit<br />

For cleaning A/C systems by<br />

flushing with refrigerant.<br />

PATENT PENDING PATENT PENDING PATENTED


20<br />

Fully automatic station for recovering, recycling,<br />

and recharging R134a refrigerant, for use with<br />

buses and industrial vehicles.<br />

STANDARD FEATURES<br />

Automatic Leak Testing<br />

The station checks for leaks<br />

during the vacuum phase. If<br />

leaks are found, it interrupts<br />

operation and gives an alarm.<br />

Automatic Discharge<br />

(PATENT PENDING)<br />

of non-condensable gases via<br />

solenoid valves, with bottle<br />

temperature and pressure<br />

sensors.<br />

Gear Pump<br />

for refrigerant charging.<br />

Eck bus<br />

Features identical to<br />

ECK BUS-PRO but:<br />

➜ without gear pump<br />

➜ with automatic bottle<br />

heater<br />

OPTIONS<br />

Type of refrigerant R134a<br />

Service procedure Fully automatic or manual<br />

Voltage<br />

220-240V - 50/60 Hz<br />

Scale resolution 10 g<br />

Oil scale resolution 5 g<br />

Working temperature range 11/49°C<br />

Filter system<br />

2 filters for humidity<br />

Vacuum pump<br />

170 litre/min capacity, 0.1 mbar vacuum level<br />

Compressor<br />

Hermetically sealed, 21 cc, high pressure<br />

Gear pump<br />

1 kg/min capacity<br />

Refrigerant bottle 40 litres, refillable<br />

Hoses<br />

6 metres<br />

Overall size<br />

80 x 120 x 115 cm<br />

Weight<br />

140 kg<br />

Thermal printer<br />

Standard equipment<br />

Display<br />

LCD<br />

Pressure gauges Class 1<br />

Flushing kit<br />

For cleaning A/C systems by<br />

flushing with refrigerant.<br />

PATENTED<br />

Eck bus-pro


Leak Detection Products & Consumables<br />

21<br />

AEK203 - Cobra kit HD<br />

Leak detector kit for A/C circuits<br />

including: goggles,<br />

UV lamp, hermetic<br />

dye cartridge<br />

(55 ml), injector<br />

AEK126-3-6 - Box of 6 hermetic<br />

cartridges of dye (125 ml) for R134a<br />

PAG46<br />

AEK265-6<br />

Box of 6 hermetic cartridges<br />

of oil (270 ml) for HFO1234yf<br />

AEK203-H - COBRA KIT HD HYBRID<br />

Identical to the AEK203 but with dye<br />

cartridge for hybrid vehicles<br />

AEK270-6 - Box of 6 hermetic cartridges<br />

of dye (125 ml) for HFO1234yf<br />

AEK222-1 - SANIFLUX LIQUID<br />

1000-ml bottle<br />

AEK203-C-5 - Box of 5 hermetic cartridges<br />

of dye (55 ml)<br />

AEK203-H-C-5 - Box of 5 hermetic cartridges<br />

of dye (55 ml) for hybrid vehicles<br />

AEK133-1<br />

Box of 12 – 7.4-ml cartridges<br />

AEK107-3 - Electronic LEAK DETECTOR:<br />

one instrument for identifying all halogen<br />

gases, including CFC, HCFC, HFC.<br />

AEK145-4 - COBRA CARTRIDGE KIT<br />

A/C circuit leak detector kit:<br />

UV lamp, goggles,<br />

6 cartridges (7.4 ml each) of dye,<br />

injector, 120-ml bottle of dye cleaner<br />

AEK204<br />

Oil kit for hybrid vehicles: hybrid-vehicle<br />

oil cartridge (55 ml), injector<br />

AEK107-6 - Electronic leak detector for<br />

combustible gases<br />

(50-1000 ppm) ideal for nitrogen +<br />

hydrogen mix<br />

AEK145<br />

Cobra lamp + goggles<br />

AEK204-H-5<br />

Box of 5 hermetic cartridges of<br />

oil for hybrid vehicles (55 ml)<br />

AEK147-1<br />

Rechargeable UV lamp: 12V, 50W<br />

AEK146 - DYE INJECTOR GUN,<br />

including dye (bottle for 64 applications),<br />

hose and coupling for R134a,<br />

high/low pressure adapter, air discharge<br />

coupling<br />

AEK125-1-6<br />

Box of 6 cartridges of A/C<br />

POE oil (237 ml)<br />

AEK160<br />

Air Fresh Spray deodorant spray<br />

AEK126-4<br />

350-ml bottle of universal dye<br />

PAG46<br />

PAG100<br />

PAG150<br />

AEK250 - 6<br />

AEK255 - 6<br />

AEK260 - 6<br />

Box of 6 hermetic<br />

cartridges of oil (270 ml)<br />

for R134a<br />

AEK161 - DYE CLEANER<br />

Liquid detergent for removing dye<br />

(474 ml)


22<br />

A/C Accessories<br />

XK184.000000 - EASYREC<br />

Refrigerant recovery unit<br />

- For use with all refrigerants<br />

- Compressor type: oilless<br />

- Air cooled<br />

- For use with gas and liquid refrigerant<br />

- Recovery rate (vapour): 17 kg/h<br />

- Recovery rate (liquid): 50 kg/h<br />

- Recovery rate (push-pull): 240 kg/h<br />

XK184.000039<br />

Easyrec plus<br />

Identical to EASYREC with carry case<br />

for R12/R134a hoses and couplings<br />

AEK302 - Electronic scale<br />

- LCD display<br />

- Max capacity: 100 kg<br />

- Resolution: 10 g<br />

- Charging accuracy: ± 10 g<br />

- Working temperature: -10°C / +50°C<br />

AEK515 - AEK525 - AEK535<br />

Set of flexible hoses<br />

90 cm<br />

150 cm<br />

180 cm<br />

CNT4010<br />

40 - litre bottle for R134a, R22, R404a,<br />

R507, R407C<br />

AEK214<br />

Rubber hose cutter<br />

AEK102-N7-R5<br />

Set of bypass adapters for AEK 102-N12<br />

flushing kit<br />

AEK102-N7-R6<br />

Pair of universal bus adapter disks for<br />

AEK 102-N12 flushing kit<br />

AEK102-N7-R3<br />

Set of 5 filters for AEK 102-N12<br />

flushing kit<br />

AEK215<br />

Valve-extractor screwdriver<br />

AEK120-E<br />

Digital thermometer<br />

AEK211<br />

Special quick-connect coupling<br />

AEK303<br />

Digital vacuum meter:<br />

0-12000 micron range<br />

AEK221<br />

Laser thermometer<br />

KITDB003.13<br />

2013 Data Base upgrade<br />

AEK118<br />

Compressor vane comb<br />

AEK220<br />

Digital thermometer with probe<br />

SCH8182<br />

USB-RS232 adapter for downloading<br />

station data to a USB memory key<br />

TUB1149 - Low-pressure service hose,<br />

6 m<br />

AEK116<br />

Reducer fitting for bottle<br />

AEK109A<br />

High-pressure terminal valve<br />

TUB1148 - High-pressure service hose,<br />

6 m<br />

+<br />

AEK116-1<br />

ACME hose reducer fitting for bottle<br />

AEK109B<br />

Low-pressure terminal valve


Functions Table<br />

23<br />

R134a<br />

HFO1234yf<br />

R134a<br />

ECK 890<br />

ECK 800<br />

ECK 1090-UP<br />

ECK 1000-UP<br />

ECK 2900-UP<br />

ECK 2500-UP<br />

ECK TWIN<br />

ECK 2900-HFO<br />

ECK 2500-HFO ECK BUS-PRO ECK BUS<br />

HIGH PRECISION<br />

● – ● ● ● – –<br />

HFO UPGRADABLE<br />

– ● ● – – – –<br />

Automatic<br />

leak check<br />

REFRIGERANT<br />

MANAGEMENT<br />

● – ● ● ● ● ●<br />

● ● ● ● ● ● ●<br />

DATA BASE<br />

● ● ● ● ● ● ●<br />

Graphic display<br />

● ● ● – ● LCD LCD<br />

TOUCH SCREEN<br />

DISPLAY<br />

collapsible<br />

cartridges<br />

REFILLABLE<br />

CONTAINERS<br />

– – – ● – – –<br />

– ● ● ● ● ● ●<br />

● – – – – – –<br />

AUTOMATIC TAPS<br />

AUTOMATIC Discharge of<br />

non-condensable gases<br />

– – ● ● ● – –<br />

– – ● ● ● ● ●<br />

105 cm<br />

gear pump<br />

– – – – – ● –<br />

55 cm<br />

60 cm<br />

Flushing software<br />

– ● ● ● ● ● ●<br />

USB PORT<br />

● ● ● ● ● ● ●<br />

SANIFLUX<br />

– – ❍ – ❍ – –<br />

HYBRID<br />

– – ❍ ❍ ❍ – –<br />

DIAG (STATIC)<br />

– ❍ ❍ – – – –<br />

DIAG (DINAMIC)<br />

– – ❍ – – – –<br />

NITRO<br />

– – ❍ – ❍ – –<br />

Printer<br />

❍ ● ● ● ● ● ●<br />

bottle heather<br />

❍ ● ● ● ● – ●<br />

122 cm<br />

AUTOMATIC DYE<br />

❍ ● ● ● ● ● ●<br />

FLUSHING KIT<br />

– ❍ ❍ ❍ ❍ ❍ ❍<br />

KIT UP<br />

– ❍ ❍ – – – –<br />

69 cm<br />

70 cm<br />

● STANDARD EQUIPMENT – Not Available ❍ Optional<br />

Information regarding dimensions, data, models, and colors is not binding. <strong>Ecotechnics</strong> reserves the right to make<br />

any modifications deemed necessary. The products are not covered by any other express or implicit warranties.<br />

90 Kg


STUDIO Mirannalti<br />

<strong>Ecotechnics</strong> S.p.A<br />

Via L. Longo, 21/23<br />

50019 Sesto F.no (FI)<br />

Tel. +39 055 4207372<br />

Fax +39 055 4217972<br />

www.ecotechnics.com<br />

email: ecotechnics@ecotechnics.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!